PSSRChecklistExampleA-1PSSR清單示例A-1DescriptionofSystem/AreaUnderReview所審查系統(tǒng)/區(qū)域的描述Date日期Time時(shí)間ListofParticipants參與者名單Circulation:thosepresentplus…傳閱:參加人員加上Comments討論ItemNo.序號(hào)Recommendation(TypeActionBelowor‘notapplicable’)建議(請(qǐng)?zhí)顚懴铝行袆?dòng)項(xiàng)或注明“不適用”)Department/ResponsiblePerson部門/責(zé)任人CompletedDate完成日期ReviewHAZOPlistforapplicableactions查看HAZOP列表看相關(guān)行動(dòng)項(xiàng)是否解決ReviewCHAZOPlistforapplicableactions查看CHAZOP列表看相關(guān)行動(dòng)項(xiàng)是否解決Reviewpunchlistforapplicableactions.查看剩余工作清單看相關(guān)行動(dòng)項(xiàng)是否解決Noiselevelmonitoring(document)噪音等級(jí)監(jiān)測(cè)(文件)Exposuremonitoring(document)操作人員暴露風(fēng)險(xiǎn)監(jiān)測(cè)(文件)Emissionspermits排放許可Otheroperatingpermits其他允許的行動(dòng)SystemCheckoutItems系統(tǒng)檢查項(xiàng)目系統(tǒng)檢查條目Complete/documentqualityassuranceprogram:完成質(zhì)量保證體系并建立了文檔Receivedequipment=purchased收到的設(shè)備=購(gòu)買的設(shè)備Adherencetodesigndrawings/specifications采用的設(shè)計(jì)規(guī)范Materialsofconstruction施工材料Workmanship工藝技術(shù).Equipmentcomponentscheckout/commissioning(document)設(shè)備部件檢查/調(diào)試(文件)Loopandinterlock/permissive/alarm:setpointadjustmentandtesting(documentresults)回路和聯(lián)鎖/許可/報(bào)警:設(shè)置點(diǎn)調(diào)整和測(cè)試(文檔記錄)Instrumentcalibrationsdoneanddocumented儀表校訂完成并記錄Validationprotocoldeveloped,approvedandexecuted制定、批準(zhǔn)和執(zhí)行的驗(yàn)證協(xié)議Pressuretestingdoneanddocumented壓力測(cè)試完成并記錄Systemcleanedandflushed系統(tǒng)已完成清掃、沖洗Fireprotectionssystemsinspected,acceptance-testeddocumentationprovided消防系統(tǒng)已檢查,并有測(cè)試、驗(yàn)收記錄Ventilationsystemsbalanced通風(fēng)系統(tǒng)已平衡Performancecheckoutoflocalexhaustsystems局部排氣系統(tǒng)的性能檢測(cè)Vibrationmeasurements/documentation振動(dòng)測(cè)量記錄Fieldradiographydoneanddocumentedasrequired現(xiàn)場(chǎng)放射性物質(zhì)檢測(cè)已完成并記錄Baselinedata,suchasthicknessreadingsforpressurevessels/piping基礎(chǔ)數(shù)據(jù),如壓力容器/管線的壁厚Otherbaselinedata其他基礎(chǔ)數(shù)據(jù)NDTreports無(wú)損檢測(cè)報(bào)告Waterbatching(document)配水(記錄)EngineeringDesignDocumentation工程設(shè)計(jì)資料Narrativeofcontrolphilosophy/Sequenceofoperationsdocumentation操作控制原理/操作順序的說(shuō)明資料Instrumentindex儀表索引Instrumentloopdiagrams儀表回路圖Interlock(safety&non-safety)descriptions聯(lián)鎖(安全和非安全)描述As-builtdrawings:P&IDs,electrical,piping,mechanical竣工圖:P&ID圖,電氣圖,配管圖,機(jī)械圖Tabulationofprocessalarms,interlocks/permissivedescriptionsandtripswithsettings(P&ID)工藝報(bào)警表、聯(lián)鎖/許可說(shuō)明表和帶設(shè)定值(P&ID)的跳轉(zhuǎn)表Reviewandapprovaloffireprotectionssystemsdesign消防系統(tǒng)設(shè)計(jì)的審查和許可Pipingspecifications(P&I/mechanicaldrawings)配管圖(P&I圖/機(jī)械圖)Pressurereliefdevicesizingcalculations安全閥規(guī)格的選定計(jì)算ASMEcodepressurevesselsU-1datasheets(toMaintenance)壓力容器ASME代碼U-1數(shù)據(jù)表(用于維修)Referencecodes/standardsforfacilitydesign裝置設(shè)計(jì)的參考規(guī)范/標(biāo)準(zhǔn)Referencecodes/standardsforfacilityinstallation設(shè)備安裝的參考規(guī)范/標(biāo)準(zhǔn)Designcodesforspecificequipment特殊設(shè)備的設(shè)計(jì)規(guī)范Weldercertification焊工資格證書NDTcertification無(wú)損檢測(cè)證書Electricalclassificationdrawings電器分類圖Electriciancertificationforclassifiedareas特定施工區(qū)域的電工資格證書MaintenanceItems維修項(xiàng)目SparepartslistsdevelopedListequipment:備品備件清單并附設(shè)備清單Stockrequiredspareparts備品備件所需儲(chǔ)存設(shè)施Equipmentmanuals/specificationstoMaintenanceandOperatingDepartment維修和操作部門的設(shè)備手冊(cè)/說(shuō)明Vendorprints供應(yīng)商提供的印刷資料Submitpreventivemaintenancerequests(PM’s)提交的預(yù)防性維修要求Servicecontractsinplace服務(wù)合同已簽訂Trainmaintenancepersonnelanddocument培訓(xùn)維修人員和相關(guān)培訓(xùn)資料OperationalItems生產(chǎn)項(xiàng)目DevelopSOPandspecialprocedures–incorporatesafetyandoperationalissues:編寫標(biāo)準(zhǔn)操作規(guī)程(SOP)及特殊操作規(guī)程——考慮了操作風(fēng)險(xiǎn)和可操作性問題Completechangecontrolauthorizations完成變更控制授權(quán)Develop/issueoperatingprocedures:制定/頒布下列操作規(guī)程Initialstart-up初次開車Normalstart-up正常開車Normaloperation正常操作Normalshutdown正常停車Emergencyoperationsincludingemergencyshutdown包括緊急停車的應(yīng)急操作Start-upfollowingemergencyshutdown緊急停車后開車Start-upfollowingturnaround大修后開車Non-routineprocedures(equipmentclean-out,equipmentpreparationformaintenance)非常規(guī)程序(設(shè)備清理、設(shè)備維修準(zhǔn)備)Auxiliaryequipmentoperation輔助設(shè)備的操作Trainoperatingpersonnelanddocument培訓(xùn)操作人員和相關(guān)培訓(xùn)資料Providetechnicalcoverage技術(shù)服務(wù)范圍Whatistheprobabilityofcontainmentfailure?Whatarethesubsequentconsequences?Reviewspillcontainment,rainwaterrunoff,andfirewatercontainment.防泄漏設(shè)施的失效概率是多少?失效的后果是什么?審查防泄漏設(shè)施、雨水流量和消防水容量ElectricalIssues電氣問題Panelaccess,clearancearoundpanel,keys,etc.配電盤的通道、配電盤周圍的間隙、鑰匙等Cableentrysection–glanding,housekeepingandotherissues電纜接入部分—密封、保潔及其他問題Panelpowersourceidentified?Multiplefeeds?配電盤電源的標(biāo)識(shí)?多源供電?Spaceheatersrequired?需要空間加熱器嗎?Lightinginpanels配電盤里的照明Canopiesetc.foroutdoorpanels用于室外配電盤的雨棚等Protectionsettingsavailable?有保護(hù)設(shè)置嗎?Panelboardschedules配電盤面板清單Sparecapacityavailable?有備用容量嗎?PPEavailable?HVmats,gloves有個(gè)人防護(hù)用品嗎?有高壓絕緣墊嗎?有高壓絕緣手套嗎?Emergency/Standbypowerrequired?有應(yīng)急/備用電源嗎?VSDsettingsavailable–factory/commissioning變頻器設(shè)置—工廠/調(diào)試Roomaccess,permitting,maintainability,ingress/egressofequipment房間通道、許可證、可維修性、設(shè)備的進(jìn)出通道Pocketsfordrawingsinpanels?配電盤的圖紙集Voltagewarninglabels?電壓警告標(biāo)簽Ventilationsufficient?通風(fēng)充足嗎?Suitabilityforarea-IPrating,GMPsuitability,hazardousareaclassification.區(qū)域適宜性——國(guó)際防護(hù)等級(jí)、GMP適宜性、危險(xiǎn)區(qū)域分類ReliefDevices泄放設(shè)備AretherestandardmarkingsontheP&ID?在P&ID圖上有標(biāo)準(zhǔn)代號(hào)嗎?Dorelieflinesventtoasafelocation?放空線排放到一個(gè)安全地點(diǎn)嗎?Arerelieflinesandreliefdevicessecuredandadequatelysized?放空線和泄放設(shè)備安全嗎?尺寸足夠大嗎?Arethereanyisolationvalveswhichwillinhibitoperationofreliefvalvesifclosed?IfYES,nominateOperationstomonitor.IfNO,recordno.有處于關(guān)閉狀態(tài)會(huì)抑制放空閥操作的隔離閥嗎?如果有,請(qǐng)指定操作人員對(duì)其進(jìn)行監(jiān)視。如果沒有,記錄無(wú)Isthereastandardoperatingprocedureforreliefdevicesinplace?現(xiàn)場(chǎng)有泄放設(shè)備的標(biāo)準(zhǔn)操作規(guī)程嗎?ForFieldVerification現(xiàn)場(chǎng)確認(rèn)Islightingsufficient?照明充足嗎?Isemergencylightingsufficient?應(yīng)急照明充足嗎?Aresteampipes,valves,ortrapssituatedwithinproximityofpeopleinsulated?位于人接近范圍內(nèi)的蒸汽管線、閥門或疏水器被隔離了嗎?Isallinstrumentationidentifiedandtagged?所有的儀表都有標(biāo)識(shí)和掛牌了嗎?Isthereanyrustedordamagedequipment?有任何生銹或損壞的設(shè)備嗎?Areswinggatesinstalledontopofladdersoronaccessplatforms?在梯子頂部或平臺(tái)通道上安裝了止回門嗎?Reviewedgeprotectiononplatformsandheights.Willitprotectpersonnelandequipment?Isaccessadequate?檢查平臺(tái)和高處的邊緣保護(hù)。它能保護(hù)人員和設(shè)備嗎?通道足夠嗎?Dosafetyshowersprovideahazardtopeople(slips),product(contaminationofsystems),oringresstoelectricalswitchgearorequipment?安全噴淋對(duì)人(滑跤的危險(xiǎn))、產(chǎn)品(系統(tǒng)的污染)或內(nèi)部的電氣開關(guān)柜或設(shè)備產(chǎn)生危險(xiǎn)了嗎?Aresafetyshowerssuppliedfromtemperedwater?安全淋浴供應(yīng)熱水嗎?Ischemicaldosingwithinasafeproximityofpeopleandproduct?化學(xué)品操作是在人和產(chǎn)品安全接近范圍內(nèi)嗎?Labelallpipelines標(biāo)識(shí)所有的管線Labelallelectricswitches,disconnects,MCCs,controlpanels,cables,etc.標(biāo)記所有的電氣開關(guān)、中斷器、電動(dòng)機(jī)控制器、控制盤和電纜Labelvessels(material,hazardwarnings)List:標(biāo)記容器(材料、危險(xiǎn)警告)的清單Sealwallpenetrations密封墻壁的滲透Pourconduitseals灌注導(dǎo)管的密封InstallfireextinguishersEvacuationroutespostedInstallappropriateareasignsIsallscaffoldingandequipmentremoved;isgeneralhousekeepingacceptable?Ifthereispotentialforentrapmentorexposure,hasanE-Stopbeenprovided?Iffullguardingisinplace,hasalockableisolationdevicebeenprovided?Pestcontrolrequiredinroom/building?MSDSsheetsrequired?Sprinklersinrooms?Singlepointoffailurecondition?Hasitbeenidentified?–Record.
PSSRChecklistExampleA-2Pre-startupSafetyReviewChecklistInspectionDate:Department/Area:ProjectNumber:Title/Equipment:Signaturesbelowindicateacceptancethattheequipmentorprojectissafeandsatisfactorytostart-upwiththeexceptionsnoted.Engineering/MaintenanceDateEHSGroupDateQAGroupDateManufacturing/OperationsDateProjectEngineerDateProcessEngineeringDate
ChecklistItemNo.Details(referencecategory/itemno.)ResponsibilityCompleteSign&DateCategoryAActionItems-ItemstobecompletedBEFOREauthorizationandstart-upCategoryBActionItems-ItemstobecompletedAFTERstart-upSignbelowonlywhenallpunchlist“beforestart-up”itemsarecompletedAuthorized:Facility/EquipmentOwnerSignature:Date
PSSRITEMNO.CATEGORY/ITEMTOASSESSNotApplicable1.1GENERALSAFETY1.1.1HaveALLappropriatepersonnel(Operations,Maintenance,Technical,andSupervision)receivedadequateandappropriatetrainingontheequipmentandoperatingprocedures?1.1.2HasadequateandappropriatePPE(PersonalProtectiveEquipment)beenspecifiedintheWorkProceduresand/orStandardOperatingProcedures.HasthePPEbeenprovided?HavethePPEusersbeentrainedintheuseofthePPE?Isthetrainingdocumented?1.1.3Havemeasuresbeentakentoadequatelyguardalldangerouspartsofthisequipment?1.1.4Hassufficientprovisionbeenmadefortheelectricaland/ormechanicalisolationoftheequipment?1.1.5Arepointsofisolationclearlymarked/labeledandreadilyaccessible?1.1.6Havebump/triphazardsbeenproperlyidentifiedandadequatelymarked?Haveallsharpedgesbeenremoved?1.1.7Hasproperguarding,handrails/barriers,beenprovidedtopreventfalls?1.1.8Haveallhot/coldsurfacesbeenadequatelyguardedtopreventburns?Areallcoldsurfacesadequatelyinsulatedtopreventcondensationdrips(sliphazards)?1.1.9AreSafetyShowersandEyeAretheSafetyShowersandEyeDotheSafetyShowersandEyeAretheSafetyShowersandEye1.1.10Hassufficientlightingbeenprovidedsothatoperation,servicing,maintenance,andrepairofthefacilitiescanbecarriedoutsafely?1.1.11Arenotices,dials,screens,etc.forprovidingoperationalinstructions,safetywarnings,andemergencyinformationprovided,ifrequired,andpositionedsothattheyareclearlyvisibleandeasilyread?1.1.12Havealloverheadfixtures,forexample,pipe-hangers,pipesleeves,pipesleevecovers,valvehandles,flooropeningcovers,etc.,whichcouldfallorbedislodged,beenproperlysecured?1.1.13ArealloftheapplicableWorkPermitProcedures(ConfinedSpaceEntry,LockOut/TagOut,HotWork,HighWork,etc.)inplace?HavetheOperating,Maintenance,andSupervisorypersonnelbeenproperlytrainedontheWorkPermitProcedures?1.1.14Hasthefireprotectionsystemsbeeninspectedbytheinsurancecompany?Hasacceptancetestingbeencompletedanddocumented?Isthereanagreedontestandinspectionprogramforthefireprotectionsystems(includingalarmsystems)?1.2MACHINERY/EQUIPMENTSAFETY1.2.1Hasthemachinery/equipmentbeeninstalledsothatitwillbestableandsecureduringoperation?1.2.2Hasallaccesstodangerousmovingparts,ordangerzonescreatedbytheequipment,beenpreventedbytheprovisionofthecorrectguards,interlocks(bothsafety&non-safety)and/orbarriers?1.2.3Havethecorrectsafetymeasuresbeentakentopreventanyriskfromhot/coldsurfaces,ejectionofmaterial,failureofpartsandtheirejection,overheating/fire?1.2.4Hassafeaccessbeenprovidedtotheequipmentthatrequiresoperatorandcalibrationandmaintenancepersonnelaccessfornormaloperations,adjustments,service,calibration,maintenance,orrepair?Haveslip,trip,trap,crush,entanglement,fall,bump,andcuthazardsbeenminimized?1.2.5IstheequipmentprovidedwiththeproperlyidentifiedSTART/STOPandEMERGENCYcontrolsthatarepositionedforsafeoperationwithouthesitation,orlossoftime,andwithoutambiguity?1.2.6IstheequipmentprovidedwithaclearlyidentifiedmeanstosecurelyisolateitfromALLenergysources?1.3ERGONOMICS1.3.1Havetheworkstations,workplace,orequipmentbeenconstructedsothatneedforstooping,bendingstretching,over-reachingandworkingover-headduringoperationhasbeeneliminatedorminimized?1.3.2Hastheneedtolift,carry,pushorpullheavyloads,orparts,beeneliminatedtotheextentpossible?1.3.3Arealldisplayscreens,dialsandSTART/STOP/EMERGENCYbuttonspositionedsothattheyarereadilyvisibleandaccessiblebytheoperatingpersonnel?1.3.4HaveVisualDisplayScreensbeenpositionedsothatinterferencefromglareisreducedtotheminimum?1.3.5Haveworkstationsbeendesignedandequippedsothattheoperatorcanadoptacomfortableposition?(Thatis,abletostand,orchangepositionandsitupright,angleatelbowsandknees90,feetonfloor.)1.3.6DoestheoperationofthisequipmentincreasetheriskofUpperLimbDisorder;forexample,repetitivetasks,handlingoperations,machinepacedworkandprolongedoperation?1.4OCCUPATIONALHEALTH1.4.1Haveallhealthrisksarisingfromthegases,liquids,dusts,mists,biologicalhazardsorvaporsusedby,containedinoremittedbythisequipmentbeenassessed?Havethehealthrisksbeeneliminatedorareadequateengineeringcontrolsutilizedtominimizetherisks?1.4.2HasadequateRPE(RespiratoryProtectiveEquipment)beenspecifiedintheOperatingProcedures?1.4.3HastheneedforanOccupationalHealthMonitoringProgrammebeenassessed?HasaMonitoringProgrammebeenscheduled?1.4.4HavetheOperatingProceduresbeenreviewedtotakeintoaccountanyadditional“healthhazards”whichmayarisefromoperationormaintenanceofthisequipment?1.4.5HasadequateLEV(LocalExhaustVentilation)beeninstalled,tested,balanced,andenteredonanInspectionSchedule?1.4.6Haveadequateinspection/cleaningportsbeenprovidedonductwork?1.4.7Arerelieffacilitiesdirectedtoasafeplaceawayfromtheworkplace?1.4.8HasaNoiseSurveybeenconsideredandaNoiseCompliancePlanprepared,ifrequired?1.4.9Hasallinsulationbeenidentified?1.4.10Hasallpipework,tanks,andequipmentcontaininghazardousmaterialsbeenadequatelylabeled?2.0PROCESSSAFETY2.1PROCESSTECHNOLOGY2.1.1Areup-to-dateMaterialSafetyDataSheetsavailable?2.1.2Havethehazardouseffectsofinadvertentmixingofdifferentmaterialsbeenconsidered(thatis,hasachemicalinteractionmatrixbeenprepared/updated)?2.1.3Hastheprocessdesignbasisbeendocumentedorupdated?Hasthecontrolphilosophyandsequenceofoperationsbeendocumented?2.1.4Hastheequipmentdesignbasis(forexample,BPF’s/P&IDs)beendocumented/updated?2.1.5Havetherecommendationsfromsafetyreviews,ProcessHazardsAnalysis(PHA),HazardsandOperabilityReviews(HAZOP),CHAZOP,orothers,beenimplemented?Recordanyincompleteitems.2.1.6AreallreliefdevicesshownontheP&IDs?Arestandardmarkingsusedonthereliefdevices?Aretherelief/rupturepressuresincludedontheP&IDs?2.1.7Havethepressurereliefdevicecalculationsbeenprovided?WasDIERStechnologyutilizedtosizethepressurereliefdevicesforallpressurevessels?Doesthesizingofpressurereliefdevicesagreedwiththecalculatedsizes?Dothecalculationstakeintothedownstreampiping?2.1.8Dothereliefdevicesventtosafelocations?Iscontainmentprovidedforliquidsandsolidsreleasedfrompressurereliefdevices?2.1.9Arethereisolationvalvesthat,ifclosed,willinhibittheoperationofpressurereliefdevices?Ifyes,Operationsmustestablishcontrolplanstoinsurethattheisolationvalvescannotinhibittheoperationofthepressurereliefdevices.2.1.10AreallpressurereliefdevicesincludedinthePreventiveMaintenanceProgram?Aretheinspectionandtestingofreliefdevicesinaccordancewithlocalregulations?2.2MANAGEMENTOFCHANGE–TECHNOLOGY/MANAGEMENTOFSUBTLECHANGE2.2.1Hasamanagementofchange–technology/subtlechangedocument(forexample,ChangeofDesign-COD)beenapproved?2.2.2Hasatestauthorizationbeenapproved?2.2.3Areallactionitems,arisingfromtheCOD,thatweredeemednecessaryforstart-up,complete?2.2.4Haveallchangesmadeduringconstructionbeenrecordedandauthorized?Havehazardsevaluations(PHAs,HAZOP,orCHAZOP)beendoneonallthechangesmadeduringconstruction?2.3PROCESSHAZARDSANALYSIS2.3.1HaveprojectPHAsbeenapprovedandafinalprojectsafetyreportbeenprepared?2.3.2Areallactionitems,deemednecessarybythePHAteamforstart-up,complete?2.3.3Hastheprojectbeenapprovedas“Safetoproceedwith”bythePHAteam?2.4QUALITYASSURANCE2.4.1Havechecksandinspectionsbeenmadetoensurethatcriticalequipmentisinstalledproperlyandisconsistentwithdesignspecificationsandvendor’srecommendations(forexample,alarmandinterlock(safety&non-safety)tests;equipmentalignmentandservicetoprocessinter-connections)?2.4.2Havequalityassuranceinspectionreports,coveringfabrication,assembly,andinstallation,beencompletedinaccordancewiththeproject’squalityassuranceplanandreportsfiledwiththeequipmentanddesignbasisdocumentation?2.4.3ListspecificitemsfieldcheckedaspartofthisPre-Start-upSafetyReviewtoensurethat:Theconstructionmeetsthedesignspecifications.Theconstructionmatchesthedrawings.2.4.4Havethefollowingdocumentedbeenprovidedandapproved:Instrumentindexesandinstrumentloopdiagrams?Atabulation,includingsettings,ofinterlocks(bothsafety&non-safety)andtrips(hardwireandsoftware),processalarmsandpermissivedescriptions?As-builtdrawingscoveringP&IDs,electrical,piping,andmechanical?DatasheetsforpressureequipmentbuilttoASMEorequivalentcodes?Weldercertification?Non-destructivetest(NDT)certifications?Electricalcertificationforclassifiedareas?2.5MECHANICALINTEGRITY2.5.1Havemaintenanceproceduresbeenapproved?2.5.2Havemaintenancepersonnelbeentrained?2.5.3Havesparepartslistedbeendevelopedandenteredintothepartsorderingsoftwareprogram?Arethereadequateinventoriesofspareparts,operatingsuppliesandmaintenancematerials?2.5.3Havequalitycontrolproceduresbeenapprovedformaintenancematerialsandspareparts?2.5.4Haveinspectionsandtests,includingregulatoryrequirements)forthefollowingequipmentbeenincludedinamaintenanceschedule?Pressurevesselsandstoragetanks?Pressurereliefsystems,ventsystems,anddevices?Criticalcontrols,interlocks(bothsafety&non-safety),alarmsandinstruments?Emergencydevices(includingshutdownsystemsandisolationsystems)?Fireprotectionequipment?Pipingsystems(incl.Components,forexample,valves,excessflowvalves,expansionbellows)incriticalservice?Keyprocess-to-servicetie-ins?Electricalearthening,grounding,bonding?MCCstarters?Emergencyalarmandcommunicationsystem?Monitoringdevicesandsensors?Pumps?Liftingequipment?2.5.5Hasareliabilityengineeringanalysisbeenconsidered/completedforPSMcriticalequipment?2.5.6Istheequipmentinspectedbyanyoutsidebodyandcertificatesonfile(forexample,CEmarking,liftingequipmenttestcertificates,pressuresystemsregulations,andotheritems)?2.5.7Haveallcommissioningtestsorinspectionsbeenidentified(forexample,pressure,orleaktests,passivatingprocedures)?2.6OPERATINGPROCEDURESANDSAFEWORKPRACTICES2.6.1Havestandardoperatingproceduresbeenprepared/updatedandapproved?Dotheoperatingprocedurescover:Initialstart-up?Normalstart-up?Normaloperations?Normalshutdowns?Emergencyoperationsincludingemergencyshutdowns?Start-upafteremergencyshutdowns?Start-upfollowingturnarounds/prolongedshutdowns?Non-routineproceduresuchasequipmentclean-outsandpreparationofequipmentformaintenance?Auxiliaryequipmentoperationsincludingasexamples;LEVandVentilationSystems,Heat/CoolSkids,Water(Soft,RO,WFI,Tower,etc.)Systems,InstrumentandProcessAirSystems,WasteTreatmentSystems,Cooling(GlycolRefrigeration)Systems,SteamGeneration,andothers?Safetyandoperationalissues?Changecontrolprocedures?2.7TRAININGANDPERFORMANCE2.7.1Hasspecificprocess(orjobtask)trainingbeengiventopersonnel?2.7.2.Havetrainingrecordsbeenupdated?2.8CONTRACTORSAFETY2.8.1.Haveallcontractpersonnelbeenadequatelytrainedinappropriate:chemicalawareness,maintenance,andoperatingactivitiesandevacuationprocedures?2.9INTERLOCKSANDALARMS2.9.1Hasthealarm/interlock(safety&non-safety)beenclassifiedanddesignedbytheProjectTeam?DidtheProjectTeamincludemembersofthePHAteam?2.9.2Didthelooptestingconfirmthatthealarm/interlock(safety&non-safety)actionproved,underallconceivablefailureconditions,tobefail-safe?2.9.3.PriortothisPSSR,hasaninterlock/criticalalarmStandardOperatingProcedurefortesting,throughtothefinalelement,beenpreparedandreviewed/authorizedbyacompetentpersonforeachneworupgradedcontrolsystem?2.9.4.Foralarms/interlocks(bothsafety&non-safety)withmorethanonesoftwareorhardwarecircuit,haveallpossibleinterlockroutesbeentested?2.9.5Hasallappropriateprocesstechnologybeenupdated(forexample,interlocklists,P&IDs,logicdrawings,etc.)?2.9.6DoesyourControlSystemdocumentationadequatelyspecify:Allmajorcomponentsandtheirmodelandserialnumbers?Allcommunicationcableslayoutandconfiguration?Anyconfigurableorcustomsettingsandset-up?2.9.7Hasconsiderationbeengiventosuitablefiredetectionandpreventionsystemsfortheequipment?2.9.8Doyouhaveanappropriateproceduretoensurethatyoursoftwareisprotected(forexample,routinelyarchived,key/passwordprotected,etc.)?2.9.9Hasthesoftwarebeenproperlydocumentedandfiled(forexample,logicdrawings,schematics,sequence/batchdescriptions)?2.9.10Hasallsoftwarebeenproperlyvalidatedandtested?2.9.11Isthereverificationthattheequipmentdoesnotre-start,eitheronthere-settingofaprotectivedevicesuchasaninterlock(safety&non-safety),orthere-establishmentofpowerafteranoutage?3.0ENVIRONMENTAL3.1Areallsecondarycontainment/bondingfacilitiesadequate?3.2Areallmaterialstoragefacilitiesadequateandappropriatelylabeled?3.3Haveadequatearrangementsbeenmade,priortostart-up,fortheidentification,classification,andsafedisposalofallwastematerials?3.4Haveallmaterials,usedinthesystem,beenenteredontheAreaChemicalsInventoryList(orequivalent)?3.5AreupdatedAreaSpillProceduresavailable?3.6ArematerialUnloadingFacilitiesadequateandconstructedinaccordancewithCorporateSafety,Health,andEnvironmentalStandards?Isthereadequatecontainment(110%oftruckvolume)intheunloadingareasforbulkliquidchemicals?3.7HavetheCorporateEnvironmentalGuidelinesbeenfollowedduringthedesignstageofthisproject?3.8Haveallwastestreamsbeenidentified,quantified,analyzedandminimized?3.9ArealloftheapplicableConstruction,EnvironmentalandOperatingPermitsupto-dateandapproved?4.0CAER4.1Haveallnecessaryprecautionsbeentakentoensurethattheequipmentisnotasourceofignitiontoanyflammablematerials,irrespectiveoftheirsource?4.2Arefireprotectionfacilitiesadequateforexample,fireextinguishers,firewalls,sprinklersystems,AlarmBoxes,etc.)?4.3AreEmergencyEscapeRoutes,includingladders,adequateandproperlysignposted?4.4Isemergencylightingadequate?4.5IssufficientRespiratoryProtectiveEquipment,suchasEscapeSetsorSelf-ContainedBreathingApparatus(SCBA)available?4.6HaveEmergencyProceduresbeenpreparedandrelevantpersonneltrained?4.7IstheCommunityPaneladvisedofproposednewmajorprojects?5.1HasanElectricalSafetyChecklist(AcceptanceofElectricalInstallations)beencompletedbyacompetentpersonnel?5.2HastheequipmentbeenproperlyinstalledandconstructedtoCorporateguidelinesandlocallegislation,anddoesitmeetanyspecialinstallationrequirementsnotedonthemanufacturer’scertificate?5.3Hasequipmentbeendesignedandpurchasedfortheconditionsunderwhichitwilloperate(forexample,hazardousareas)?5.4Arealllivepartsadequatelyenclosedtopreventaccess?5.5Doesgroundingandbondingcomplywithcorporateandlocalstandards/legislation?5.6Havefusesorcircuitbreakersbeenprovidedwhichwillautomaticallydisconnectthesupply?5.7AreFirstAidStations,singlelinedrawingsandPPErequirementsavailableinMotorControlCenters(MCC),ElectricalControlRooms(ECR)/Sub-stations,asappropriate?5.8Haveallrelevantdocumentationanddrawings(forexample,P&IDs,SLDs,Schematics,equipmentarrangement,I/O,logic,electricalclassificationandPanelScheduledrawings)beenupdatedtoreflectthecurrentinstallation?5.9HaveallnewSub-stationBreakers,MCCisolators,startersorotherappropriateequipmentbeenregisteredontotheSiteInspectionSchedule?5.10Haveanyelectricalcircuits,maderedundantbythisinstallation,beenproperlyD&R’d?6.0FIELDVERIFICATION6.1Isthenormallightingadequatefornormalandmaintenanceoperations?6.2Isemergencylightingsufficient?6.3Areallhotandcoldsurfaces,whichmaycauseburns,intheproximityofpersonnelinsulated?6.4Areallinstruments,equipmentandpipingadequatelylabeled?6.5Isthereanyrustedand/ordamagedequipment?6.6Areswinggatesorchainsinstalledatthetopofladdersand/oronaccessplatforms?6.7Arethereanygapsbetweenplatformsandequipmentthatcouldcreateafoothazard?6.8Isequipmentandplatformaccessadequate?6.9Dosafetyshowers/eyewashstationscreateahazardtopersonnel(slips),potentialforcontaminationofproduct(entrytoequipment)oringresstoelectricalequipment?6.10Aresafetyshowersandeyewashstationsadequatelymarkedandreadilyvisible?Istheaccesstothesafetyshowersandeyewashstationsuninhibited?6.11Areallpipelineslabeled?6.12Areallelectricalswitches,disconnects,MCCs,controlpanels,cables,etclabeled?6.13Isalltheequipmentclearlylabeled?Whererequiredarethematerialsandhazardsincludedonthelabeling?6.14Arewallpenetrationsadequatelysealed?6.15Areelectricalconduitssealedinaccordancewithcoderequirements?6.16Areevacuationroutesclearlymarked?6.17Arefireextinguishersinstalledproperly?6.18Hastherequiredsignagebeenposted?6.19Areemergencystopsprovidedwherethereisapotentialforentrapmentorexposure?6.20Hasallscaffoldingandconstructionequipmentbeenremoved?Ishousekeepingacceptable?6.21Isallrequiredequipmentguardinginstalled6.22DoesalltheapplicableequipmenthavetherequiredCEmarkingdisplayed?DoesalltheapplicableequipmenthavetherequiredULlisting/labeling?6.23Havenoise-monitoringevaluationsbeencompleted?Havesignsbeenpostedwherenoiselevelsexcess85dB?Areear-plugsavailablenearareasexceeding85dB?
PSSRChecklistExampleA-3ATTACHMENTA-PROCESSPRE-STARTUPSAFETYREVIEWCHECKLISTAREAORPLANTUNDERREVIEW:DATE:LISTOFPSSRTEAMMEMBERS:Instructionsforusingthisform:1.ReviewtheentirechecklistandmarkacheckincolumnAtoindicateanitemorareatobeincludedinthereview.2.Ifthereareissuestoberesolvedaftertheinitialreview,completeAttachmentB-PSSRPotentialIssue–FindingForm3.ForeachitemorareawithacheckincolumnA,placeacheckincolumnBwhentheitemorareahasbeensatisfactorilyreviewedorapotentialproblemhasbeenresolved.ColumnAIncludeColumnBCompletedCategory/PSSRItemtoEvaluateLocationandlayoutSiteConditionsDrainageFloodcontrol/protectionPrevailingwindAirorwaterpollutionexposuresOthersiteconditionsrequiringattentionSoilprotectioninstorage,materialshandling&processareasNearbyoperationsHazardsfromHazardstoTrafficVehicular/railroad/pedestrianClearances,hazardsAdequacyoftrafficsignsSecuritySpecialrequirementsimposedbynewfacilityStorageandhandlingofche
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 關(guān)于夫妻雙方離婚協(xié)議書
- 土地租賃合同雙方協(xié)議書七篇
- 2025無(wú)財(cái)產(chǎn)離婚協(xié)議書
- 面神經(jīng)炎病因介紹
- 錯(cuò)構(gòu)瘤病因介紹
- 蕁麻疹病因介紹
- 11化學(xué)中考真題匯編《氧氣的性質(zhì)》及答案
- (2024)乳制品加工項(xiàng)目可行性研究報(bào)告寫作范本(一)
- 2024-2025學(xué)年人教版八年級(jí)英語(yǔ)上學(xué)期期末真題 專題01 單項(xiàng)選擇(安徽專用)
- 2023年耐磨劑項(xiàng)目融資計(jì)劃書
- 民辦學(xué)校教職工入職背景審查制度
- 2024年新人教版四年級(jí)數(shù)學(xué)上冊(cè)《教材練習(xí)21練習(xí)二十一(附答案)》教學(xué)課件
- 大國(guó)三農(nóng)II-農(nóng)業(yè)科技版智慧樹知到期末考試答案章節(jié)答案2024年中國(guó)農(nóng)業(yè)大學(xué)
- 二級(jí)公立醫(yī)院績(jī)效考核三級(jí)手術(shù)目錄(2020版)
- 6人小品《沒有學(xué)習(xí)的人不傷心》臺(tái)詞完整版
- 人教版六年級(jí)數(shù)學(xué)上冊(cè)總復(fù)習(xí)教案
- 勞動(dòng)合同法測(cè)試題含答案
- 自閉癥兒童行為檢核表學(xué)前版
- 五年級(jí)上冊(cè)數(shù)學(xué)專項(xiàng)練習(xí)高的畫法 全國(guó)通用
- 民警個(gè)人季度小結(jié)范文(3篇)
- 商場(chǎng)商戶裝修入駐工作流程
評(píng)論
0/150
提交評(píng)論