版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡介
1、應(yīng)用DHPLC技術(shù)進(jìn)行診斷性分析的質(zhì)量保證體系張澤云美國環(huán)球基因公司中國代表處診斷性分分析的要要求臨床分子子遺傳學(xué)學(xué)分析的的復(fù)雜性性臨床分子子檢測結(jié)結(jié)果的一一致性和和精確性性變性高效效液相色色譜(DHPLC)作為一種種高效和和敏感的的基因突突變檢測測技術(shù)DHPLC技術(shù)質(zhì)量量控制AMERICANCOLLEGE OF MEDICALGENETICSStandardsand Guidelinesfor Clinical Genetics Laboratories2005 EditionG:CLINICALMOLECULARGENETICSTheseStandardsand Guidelinesspe
2、cificallyrefertothe useofmoleculartechniquestoexamine heritableorsomatic changesinthe human genome.G18Denaturing HighPerformanceLiquid Chromatography (dHPLC)(SectionAddedNovember2003)CMGSBest Practice GuidelinesUseoftheWAVESysteminDiagnosticServicePreparedandedited by JohnHarvey,NationalGeneticsRefe
3、renceLaboratory(Wessex),Salisbury,UKandEls Schollen,Centrefor Human Genetics,Leuven, Belgiumlast update:12March2004IntroductionLaboratoryprocessDHPLCsystemDataqualityChecking&reportingguidelinesReferencesDHPLCSOPsInstrument or maintenanceSOPTechniqueGeneral DHPLC SOPWAVE 3500, 3500HTMethodDisease-sp
4、ecific SOPsRett,BRCA,HNPCCMarfan, Applicationcompany +usersgeneral users +companyspecificusersSupplementary Appendix 1STANDARDOPERATINGPROCEDURE WAVE SystemOperationand MaintenanceSOP- O&MWAVESystemOperation andMaintenanceForWAVESystemModels 3500, 3500A and3500HTWAVESystemOperation andMaintenanceAna
5、lysisoftheWAVELow &HighRangeMutationStandardsThemaintenanceprocedureDNASep andDNASep HT cartridgemaintenanceRole of Mutation standards:checkingofcorrect functioning of theWAVESystem, includingoven calibration,cartridgeperformance, buffercompositionandstability,toensurereproducibility andaccuracyofth
6、echromatographic analysis.Mutationstandardsberun when:lTheroutinepre-run,lWeeklyand monthlymaintenanceprocedure,lAfterreplacementofanycomponent,lValidation fora newbatch,lAsanassaycontrol,atthebeginning andendofeveryrun,preferablyalso after every 100injections forlong runs.AnalysisoftheWAVELow &High
7、RangeMutationStandardsNormalrangesofthemutationstandardsThemaintenanceprocedure3.1Filterandflush3.2Pre-runmaintenance3.3Weeklymaintenance3.4Quarterlymaintenance3.5Other maintenance operations3.6Preventativemaintenanceprocedure andsystemvalidationFilterand flushTheprinciple of filtrationinvolvespreve
8、ntingunwantedcontaminantsfromenteringthesystem.Filtration appliestotwo specific areas:solvent filtrationand in-linefiltration.Thesystem flushing is to removemobilephasesaltcomponents thatcan precipitate under strongsolvent conditions.Pre-run maintenance1.Buffercheck2.Injectionsystem washing3.Pressur
9、echeck4.Checktheabsorbanceonthedetector5.PurgethelinesWeeklymaintenanceInlinefilter replacementCheckthesyringeQuarterlymaintenanceCheckUVlampUVlamp replacementCleaningthesystem (Isopropanolcleaning)DNASep andDNASep HT cartridgemaintenance1.Regular maintenance scheduleEvery96-192injections:Extendedho
10、t washEvery1000 injections:Reverse hotwashDNASep wash(if reversehot washfailstoresolvemutationstandards)2.Short-termcartridgestorage3.Long-Term cartridgestorage4.New cartridgeinstallationDailyMaintenanceEquilibratethecartridge50%A 50%Bfor 15 minutesRun1-2 blanksVerifysystem performance (pre-analysis
11、)RunastandardRunSamplesVerifysystem performance (post analysis)WeeklyMaintenanceAnExtendedActiveCleanWashisrecommendedevery100 injections.(Usuallydone after each96wellplate)OvenSet to:80 CPump Set to:100% D15-30minutesWASHOvenSet to:56 CPump Set to:50%A-50%BEQUILIBRATE45-90minutesRunStandards to Ver
12、ifySystemPerformance!1000InjectionMaintenanceA ReverseHot Washisrecommendedevery1000injectionsUV/FLDetectorTurn offthepumpReverse thecartridgedirection.Setthe ovento80C.Setthe pumpto100%D.60-90minutesStoring theCartridgeFlushthecartridge with100%DBuffer.Removethe cartridgefrom theWAVE System.Capthe
13、cartridgewith endplugs.Storethecartridge at roomtemperature.Installing aNew CartridgeStop thepump flowand removetheold cartridge.Removethe plugs fromthe newcartridge.Install thenewcartridge withthe arrow pointing towardtherearoftheoven.UV/FLDetectorMake surethe ovenheatsuptoatleast40C.Setthe pumpto1
14、00%D0.500mL/min.Ensurethe pressure is stableandgradually increase theflow (0.9mL/minor1.5mL/min).Flushthecartridge for15minutes.Setthe pumpto50% BufferA,50%Buffer Band equilibrate for30minutes.Equilibrating aNew Cartridge100%50% 50%VerifyNew CartridgePerformanceLow-RangeMutationStandardDNASizing Con
15、trolStandardSupplementary Appendix 2STANDARDOPERATINGPROCEDURE DHPLCSOP-DHPLCDHPLCmutationdetectiononTransgenomic WAVESystem3500Wavemaker 4.1.44& HSM3.0-2.1 (build2)Navigator 1.5.4 (build19)PCRrequirementsPrimerdesignTemplatepurityand concentrationDNAPolymerasesPCRbuffer mixPCRplatesPCRqualityandPro
16、ductmixingPost-PCR,filmuseControlsPrimerDesignUseaprimer-pickingprogramPrimers shouldideally be no closerthan 30 -50bpfromtheend of thesequencetobeanalyzedformutationsPrimers shouldbe18- 30 bp in lengthTheTmdifference betweenprimersina pairshould ideallybelessthan 2C.Size of PCRfragmentTheoptimalsiz
17、e range fordetectingmutation/SNPsbyDHPLCwith 100%accuracyis150 -500bp.Fragments500bpcanbegenerated butsensitivitydecreasedand timeofelutionincreased.Forfragments 150bp, differenceofmeltingpointbetween fragmentstoonarrow (thefragments meltovertoonarrow atemperaturerange).QuantityofPCRfragmentThePCR p
18、roductshould be sufficientlyconcentratedthat2 l runonanagarose gelproducesa clearlyvisibleband ( 20 ng/l)Dilutesamples(verylowyields)produce poorqualityresults (poor signal:noiseratio).Very highyields canlead to large proportions of misincorporations andhenceincreaseddifficultyincalling mutations.Us
19、ually 3-10l(50-200ng)ofunpurifiedPCRproductwouldbeinjectedonto thecolumn(peronetemperature).A 8lminimumaliquot of PCRproduct shouldbesuppliedinPCRtubesinstrips of 8(peronetemperature).SamplePreparationfor DHPLCDNAmustbeclean,all cellular debrisandorganiccompoundsmustberemoved.Salting outmethodispref
20、erred.DNAextracted withsomecommercial systemsmay be dilutedto10ngtoreduce effectsofimpuritiestoPCR.DNAoflow qualitywillresultinsub-optimalPCR results(hence DHPLC profiles).DNAquality& concentrarionTable1.Recommendedcleaningprocedures forDNAextraction.Isolation MethodRecommended Additional Cleaning:O
21、rganic Extraction(e.g. phenol/chloroform)Chloroform/isoamyl back-extraction followed by ethanol precipitation and washChaotropic Salts(e.g. guanidinium isothiocyanate)Ethanol precipitation and washSpin ColumnEthanol precipitation and washTable2.RecommendedDNAquantitiesused forPCR(50L reaction).Templ
22、ateRecommended QuantityHuman genomic DNA50-200 ng Phage DNA 1-10 pg Plasmid DNA 0.1-1.0 pgTheImportanceofPolymerase Fidelity forMutationDetectionImportance of highfidelityindHPLC500bpWild TypeFragmentRedTrace Optimase PolymeraseGreenTrace 9:1MixAmplitaqGoldandPfu TurboHeteroduplexdue to misincorpora
23、tionPolymerase Fidelity ComparisonMaximum recommended concentrationsofacceptable PCRadditivesAcceptable additives (maximum final concentration)Additives where final concentrationmust be 2mVatA260.Peaksofintensity30%ofthe averagepeakintensity.Weak peaks aremore likelytolead to false-negative/positive
24、 results.Minimum peakintensityIdentificationofsequencevariantsThepresenceofheteroduplexesisoftendetectedasachangeinthe numberofpeaks(may be 2, 3or4peak pattern).Twopeakpatternsaccount forthemajorityofmutations.Completeresolution of the2 heteroduplexes is notalwaysnecessary.Mutationsmay appearonly as
25、 aslight broadeningofthe singlepeak,orasa subtlechangetoashoulderonthepeak.Allsamplesidentified as heteroduplexes by DHPLC analysis mustbesequenced in bothdirectionstoconfirm anddeterminethe natureofthesequencechange.Thehomoduplexwild-typepatternistypically1peak,butmay be 2peaks, dependingupon theme
26、lting profile.Elution profiles thatdiffer fromthe wild-typeindicatethepresenceofDNA sequence changes. Butthemutationtypecannotbepredicted fromthe heteroduplexpattern.Each mutation in agivenPCR fragment is predictedtohave aunique heteroduplexpattern (highlyspecificelutionprofile).Thisisusefulfor quic
27、k genotypingofunknownsamples by comparisonwithpositivecontrol samples.However,traceprofilesarenot alwaysuniquefor aspecificmutation, i.e.different DNAvariantscangiveidenticalprofiles.Changes in retentiontime do notaccurately predictthe presence of asequencechange.TracespecificityData checking,report
28、ingand storageData checkingPositiveresultsFalsepositiveresultsNegativeresultsFalsenegativeresultsSensitivityDetectionofmosaicsArchivingSupplementary Appendix 3STANDARDOPERATINGPROCEDUREMECP2SOP-MECP2DHPLCscreeningofMECP2InthecontextofRett SyndromeRett syndromeChildhoodneurodevelopmentdisorderwith ap
29、revalenceof1/10.000to1/15.000infemalebirthsMutationsintheMECP2gene,codingfor MethylCpGBindingProtein 2, aretheprimarycauseofRTTEightmutationsare recurrently found in differentpopulations.Thefirstpartofthemolecular diagnosisofRTTisthe DHPLC-screeningofexons2,3 and4 ofMECP2. Thisallows theidentificati
30、onofmore than90% of alldescribedmutations.MaterialsWorksheet:-LotNo. of allproducts-Equipmentidentifiers-Patient-identifier-Performing technician(s)-Date of experimentsMaterialsPCR-StandardPCRequipment(Locationxxx)-OptimaseDNA polymerase(2.5U/l)(Locationxxx)-OptimasePCR bufferwith Mg2+(Locationxxx)-
31、Primers (Eurogentec)(stock)as250 pmol/l. (appendixA)(Locationxxx)-Primerworksolutionscontain2.5pmol/lofeach primer(Locationxxx)-Pure dNTPs (without dUTP) (2mM)(Locationxxx)-PCRsystemMaterialsDHPLCsystem-StandardDHPLCmaterial(for partnumbersseeappendixCinSOP-O&M)-WAVESystem3500HT,WAVEMAKER4.1.44& HSM
32、3.0-2.1build2.Patient material-Patient DNA-Positivecontrols-Negativecontrols-NormalcontrolsUses of PlasmidControlsasReference Reagents no ethical problems renewable resourceCan use same reference reagent as control for PCR, heteroduplex and mutation detection analysis Universal reagents which can be
33、 incorporated in QC procedures and SOPsAdvantages: Validation of new protocols Exon specific wild type and mutated controls for existing assays Validation of transfer of protocols between machines/labsUses:MethodPre-PCRPCRCompositionPCRConditionsPost PCRHeteroduplexformationAgarose gelelectrophoresi
34、sDHPLCInterpretationoftheresultsThemutationstandards at thebeginningand endoftherun areevaluatedAllpositivecontrolsshould be visibleattheirspecifictemperatureIfoneofthe controls doesnot fulfillthe criteria,negativeresults arenotvalidand havetoberepeated. Positive resultscan be processedasusual.Theel
35、utionprofilesofa specific fragment fromthe differentpatientsarecomparedwitheach other andscoredaccording to thegeneral DHPLC criteria.Theminimumpeak heightmust be 2mV.Any particularobservationshould be noted on worksheetsortechnical reports.Ampliconswithanaberrantelution patternare re-analysed by di
36、rectsequencing on an independent ampliconInterpretationoftheresultsAllpremature truncationmutations areimmediatelyreportable.Thepathogenicityofthemissensemutations willdepend on thepositionandthe type. Interpretation is thensubjecttogood practice andliterature review.Mutations in thetwohighly conser
37、vedMeCP2domains,themethyl bindingdomain andthetranscriptionrepression domain,are likelytobecausative.Ifa mutation is of unknownsignificance,samples shouldbeobtainedfrom thepatientsparents.Ifthe mutation is found to bedenovo, it is likelytobecausative. If themutationispresent in themother, X-inactiva
38、tion studiesneedtobecarried outonthemother of thepatient If boththe motherandthe daughter haverandom X-inactivation themutationisunlikelytobecausative.ReportingproceduresNEGATIVERESULTINAFEMALENEGATIVERESULTINAMALENORMALPARENTPOSITIVERESULTINAFEMALENEGATIVERESULTINAFEMALERett syndrome is causedbymut
39、ationsintheMECP2gene.Molecularanalysisofthisgene hasbeen carriedout on patient*,however no causativemutationhasbeenfound.DHPLCanalysiswasusedtoscreenfor mutationsintheMECP2gene.This techniquehasasensitivityof95% forthedetection of point mutations,microdeletionsand microinsertionsbutwillnotdetect gross deletionsofentireexons. Only80%ofRett syndrome patients haveadetectable mutation withintheMECP2gene.NEGATIVERESULTINAMALEMolecularanalysisoftheMECP2gene hasbeen carriedout
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年度茶樓與茶葉種植基地合作租賃協(xié)議4篇
- 2025年度拆除工程噪聲及揚(yáng)塵控制合同4篇
- 2025年度智能倉儲(chǔ)廠房購買及自動(dòng)化解決方案合同4篇
- 專屬2024版月餅銷售代理協(xié)議版B版
- 二零二五年度綠色能源項(xiàng)目商鋪?zhàn)赓U合同樣本2篇
- 2024物流企業(yè)融資租賃合同
- 2025年度廠房墻地磚節(jié)能減排改造項(xiàng)目合同3篇
- 2024版螺旋鋼管買賣合同書
- 2025年廠區(qū)光伏發(fā)電與配電一體化工程承包合同4篇
- 2024照明工程分包合同
- 長鏈氯化石蠟
- 小學(xué)六年級數(shù)學(xué)解方程計(jì)算題
- 春節(jié)英語介紹SpringFestival(課件)新思維小學(xué)英語5A
- 進(jìn)度控制流程圖
- 2023年江蘇省南京市中考化學(xué)真題
- 【閱讀提升】部編版語文五年級下冊第四單元閱讀要素解析 類文閱讀課外閱讀過關(guān)(含答案)
- 供電副所長述職報(bào)告
- 現(xiàn)在完成時(shí)練習(xí)(短暫性動(dòng)詞與延續(xù)性動(dòng)詞的轉(zhuǎn)換)
- 產(chǎn)品質(zhì)量監(jiān)控方案
- 物業(yè)總經(jīng)理述職報(bào)告
- 新起點(diǎn),新發(fā)展心得體會(huì)
評論
0/150
提交評論