Dataformat
Validslavedeviceaddressesareintherangeof0–247decimal.
Theindividualslavedevicesareassignedaddressesintherangeof1–247.0isthebroadcastaddress
Itis16bits(twobytes)unsignedintegerforeachholdingandinputregister;
CommandFormat
Function3Readholdingregister
ResponseError:
110x80|0x03ErrornumCRC (Errornumasabyte)Function4Readinput register
ResponseError:
110x80|0x04ErrornumCRC (Errornumasabyte)
Function6Presetsingleregister
ResponseError:
110x80|0x06ErrornumCRC (Errornumasabyte)
Function16Presetmultipleregister
ResponseError:
110x80|0x10ErrornumCRC (Errornumasabyte)
DeviceMessageTransmissionMode/Framing
RTUMode
WhencontrollersaresetuptocommunicateonaModbusnetworkusingRTU(RemoteTerminalUnit)mode,each8–bitbyteinamessagecontainstwo4–bithexadecimalcharacters.Eachmessagemustbetransmittedinacontinuousstream.
TheformatforeachbyteinRTUmodeis:
CodingSystem:8–bitbinary,hexadecimal0–9,A–FTwohexadecimalcharacterscontainedineach8–bitfieldofthemessage
BitsperByte:
1startbit
8databits,leastsignificantbitsentfirstNoneparity
1stopbit
ErrorCheckField:CyclicalRedundancyCheck(CRC)
Thebaudrateofthetransmissionis:
BaudRate:9600bps
MinimumCMDperiod(RS485Timeout):850ms.
Waitforminimum850mstosendanewCMDafterlastCMD.Suggestionis1s;
MaximumDataLengthDefine:
Maximumreaddatalengthis45wordsinreadcommand;Maximumupdatedatalengthis45wordsinpresetcommand;ReadorupdateregistersNO.shouldintherangeoftimesof45,
eg:1~45or96~123areOK, but40~60isnotOK;
Note:
ExcepttheCEI0-21andVDE-AR-N4105powermanagementregisters,youshouldreferthemanufactory’ssuggestionwhenwritingotherregisters;
Registermap
Itis16bits(twobytes)unsignedintegerforeachholdingandinputregister;
HoldingReg
RegisterNO.
VariableName
Description
C
ustomerW
rit
e
Value
Unit
Initialvalue
Note
00
OnOff
TheInverterOn/Offstateandtheautostartstate,Thelowbyteistheon/off(1/0),thehighbyteistheautostartstateornot(1/0).
W
0x0000;
0x0001;
0x0100;
0x0101;
0x010
1;
AutostartmeanstheautopowerACwhennextpoweron
inverter.
02
PF CMD
memorystate
Setthefollowing3,4,5,99CMDwillbememoryornot(1/0),ifnot,thesesettingsaretheinitialvalue.
W
0or1,
0
Meansthesesettingswill beacting
or notwhennext
poweron
03
ActiveRate
P
ReadInvertermax
outputactivepowerpercent
W
0-100
percent
100
04
ReactiveRate
P
ReadInvertermax
output reactivepowerpercent
W
0-100
percent
05
Powerfactor
Read Inverter
output powerfactor’s10000times
W
0-20000,
0-10000is
underexcitec,otherisoverexcite
d
10000
06
PmaxH
Normal
(high)
power
0.1VA
07
PmaxL
Normal
(low)
power
0.1VA
08
Vnormal
NormalworkPV
voltage
0.1V
09
Fwversion
H
Firmwareversion
(high)
ASCII
10
Fwversion
M
Firmwareversion
(middle)
11
FwversionL
Firmwareversion
(low)
12
Fwversion2
H
ControlFirmware
version(high)
ASCII
13
Fwversion2
M
ControlFirmware
version(middle)
14
Fwversion2
L
ControlFirmware
version(low)
15
LCD
language
LCDlanguage
W
0-4,5
23
SerialNO.5
Serialnumber5
ASCII
24
SerialNo.4
Serialnumber4
25
SerialNo.3
Serialnumber3
26
SerialNo.2
Serialnumber2
27
SerialNo.1
Serialnumber1
28
MoudleH
InverterMoudle
(high)
&*5
29
MoudleL
InverterMoudle
(low)
30
Com
Address
Communicateaddr
ess
W
1
34
AutoTestSta
rt
AutoTestStart
W
0x0001
45
SysYear
Systemtime-year
W
Yearoffset
is0
46
SysMonth
Systemtime-Month
W
47
SysDay
Systemtime-Day
W
48
SysHour
Systemtime-Hour
W
49
SysMin
Systemtime-Min
W
50
SysSec
Systemtime-
Second
W
73
ModbusVer
sion
ModbusVersion
Eg:207is
V2.07
Int(16bi
ts)
81
FreqDerateS
tart
Frequencyderating
startpoint
W
0.01HZ
90
PFLineP1_LP
PFlimitlinepoint1loadpercent
W
0-255
percent
255
means
no thispoint
91
PFLineP1_P
F
PFlimitlinepoint1
powerfactor
W
0-20000
92
PFLineP2_LP
PFlimitlinepoint2loadpercent
W
0-255
percent
255
means
no thispoint
93
PFLineP2_P
F
PFlimitlinepoint
2powerfactor
W
0-20000
94
PFLineP3_LP
PFlimitlinepoint3loadpercent
W
0-255
percent
255
means
no thispoint
95
PFLineP3_P
F
PFlimitlinepoint3
powerfactor
W
0-20000
96
PFLineP4_LP
PFlimitlinepoint4loadpercent
W
0-255
percent
255
means
no thispoint
97
PFLineP4_P
F
PFlimitlinepoint4
powerfactor
W
0-20000
99
PFModel
SetPFfunctionModel
W
0:PF=1
1:PFbyset
2:defaultPFline
3:UserPFline4:
UnderExcited(Inda)ReactivePower
5:OverExcited(Capa)ReactivePower
6:Q(v)model
100
FLrate
Frequency–load
limitrate
W
0-100
10times
InputReg
Register
NO.
VariableName
Description
Value
Unit
Note
00
InverterStatus
Inverterrunstate
0:waiting,1:normal,
3:fault
01
PpvH
Inputpower(high)
0.1W
02
PpvL
Inputpower(low)
0.1W
03
Vpv1
PV1voltage
0.1V
04
PV1Curr
PV1inputcurrent
0.1A
05
PV1WattH
PV1inputwatt(high)
0.1W
06
PV1WattL
PV1inputwatt(low)
0.1W
07
Vpv2
PV2voltage
0.1V
08
PV2Curr
PV2inputcurrent
0.1A
09
PV2WattH
PV2inputwatt(high)
0.1W
10
PV2WattL
PV2inputwatt(low)
0.1W
11
PacH
Outputpower(high)
0.1W
12
PacL
Outputpower(low)
0.1W
13
Fac
Gridfrequency
0.01Hz
14
Vac1
Three/single phase grid
voltage
0.1V
15
Iac1
Three/single phase grid
outputcurrent
0.1A
16
Pac1H
Three/single phase grid
outputwatt(high)
0.1VA
17
Pac1L
Three/single phase grid
outputwatt(low)
0.1VA
18
Vac2
Threephasegridvoltage
0.1V
19
Iac2
Threephasegridoutput
current
0.1A
20
Pac2H
Threephasegridoutput
power(high)
0.1VA
21
Pac2L
Threephasegridoutput
power(low)
0.1VA
22
Vac3
Threephasegridvoltage
0.1V
23
Iac3
Threephasegridoutput
current
0.1A
24
Pac3H
Threephasegridoutput
power(high)
0.1VA
25
Pac3L
Threephasegridoutput
0.1VA
power(low)
26
EnergytodayH
Today generate energy
(high)
0.1KWH
27
EnergytodayL
Today generate energy
today(low)
0.1KWH
28
EnergytotalH
Total generate energy
(high)
0.1KWH
29
EnergytotalL
Totalgenerateenergy(low)
0.1KWH
30
TimetotalH
Worktimetotal(high)
0.5S
31
TimetotalL
Worktimetotal(low)
0.5S
32
Temperature
Invertertemperature
0.1C
40
Faultcode
Inverterfaultbit
&*1
41
IPM
Temperature
TheinsideIPMininverter
Temperature
0.1C
64
WarningCode
WarningCode
90
Grid Fault
record1-code
GridFaultrecord1-code
91
Grid Faultrecord1-year|
month
GridFaultrecord1-year|month
Yearoffsetis2000
92
Grid Faultrecord1-day|
hour
GridFaultrecord1-day|hour
93
Grid Faultrecord1-min|
sec
GridFaultrecord1-min|sec
94
Grid Fault
record1-value
GridFaultrecord1-value
&*2
95
Grid Fault
record2-code
GridFaultrecord2-code
96
Grid Faultrecord2-year|
month
GridFaultrecord2-year|month
Yearoffsetis2000
97
Grid Faultrecord2-day|
hour
GridFaultrecord2-day|hour
98
Grid Fault
record2-min|sec
GridFaultrecord2-min|sec
99
Grid Fault
record2-value
GridFaultrecord2-value
100
Grid Fault
record3-code
GridFaultrecord3-code
101
Grid Fault
record3-year|month
GridFaultrecord3-year|month
Yearoffsetis2000
102
Grid Faultrecord3-day|
hour
GridFaultrecord3-day|hour
103
Grid Faultrecord3-min|
sec
GridFaultrecord3-min|sec
104
Grid Fault
record3-value
GridFaultrecord3-value
105
Grid Fault
record4-code
GridFaultrecord4-code
106
Grid Fault
record4-year|month
GridFaultrecord4-year|month
Yearoffsetis2000
107
Grid Fault
record4-day|hour
GridFaultrecord4-day|hour
108
Grid Fault
record4-min|sec
GridFaultrecord4-min|sec
109
Grid Fault
record4-value
GridFaultrecord4-value
110
Grid Fault
record5-code
GridFaultrecord5-code
111
Grid Fault
record5-year|month
GridFaultrecord5-year|month
Yearoffsetis2000
112
Grid Faultrecord5-day|
hour
GridFaultrecord5-day|hour
113
Grid Fault
record5-min|sec
GridFaultrecord5-min|sec
114
Grid Fault
record5-value
GridFaultrecord5-value
115
116
…
…
…
133
134
135
bTestProcess<<
8 |
bAutoTestStep
Autotestprocessorautoteststep
&*3
136
wAutoTestResu
lt
Autotestresult
&*4
137
cTestStepStop
Autoteststopstep
&*4
138
0
0
0
139
ValueLimit
Safetyvoltage/frequency
limitvalue
0.1V
140
TimeLimit
Safetytimelimitvalue
1ms
141
Realvalue
Realvoltage/frequency
value
0.1V
142
Testvalue
Autotesting
voltage/frequency value
0.1V
143
Testtreatvalue
Autotest
voltage/frequency treatvalue
0.1V
144
Testtreattime
Autotesttreattime
1ms
145
146
…
…
….
178
179
&*1: Inverterfaultcode:
Faulttypevalue
Means(Themessageshowedontheinverterwhentheinverter
hasfault)
1~23
" Error:99+x",
24
"AutoTestFailed",
25
"NoACConnection",
26
"PVIsolationLow",
27
"ResidualIHigh",
28
"OutputHighDCI",
29
"PVVoltageHigh",
30
"ACVOutrange
",
31
"ACFOutrange
",
32
" ModuleHot
"
&*2: Thevalueis0.1Vwhenthefaultisthevoltage,is0.01Hzwhenthefaultisthefrequency;&*3:
Highbyte
value
Means
lowbyte
value
Means
0
Autoteststop
0
Notest
1
Autoteststarting
1
Testinggridvolthighpro
2
Autotesting
2
Testinggridvoltlowpro
3
Testinggridfrequencyhigh
pro
4
Testinggridfrequencylowpro
&*4:Thevariable“wAutoTestResult”and“cTestStepStop”:wAutoTestResultisthesteptesttimecounter,whenitreachcTestStepStop,thissteptestwillstopandfail.
&*5:InverterModel:A,couldbeshow:“T0Q0PFU1M5S1”or“00F151”Tx=(A&0XF00000)>>20
Qx=(A&0X0F0000)>>16Px=(A&0x00F000)>>12Ux=(A&0x000F
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 二零二五版科幻喜劇片制作合同3篇
- 基于2025年度財務(wù)報告的合同成本分析與管理3篇
- 了解我們的招生計劃
- 鎮(zhèn)江2025年江蘇鎮(zhèn)江市第三人民醫(yī)院第一批編外用工招聘8人筆試歷年參考題庫附帶答案詳解
- 小型微細(xì)粉碎系統(tǒng)行業(yè)深度研究報告
- 二零二五年度汽車租賃及增值服務(wù)合同樣本2篇
- Unit 4 My home Part B Lets learn(說課稿)-2024-2025學(xué)年人教PEP版英語四年級上冊
- 2025年液氨市場分析報告
- 2025年通信電力鐵塔項目可行性研究報告
- 方向盤溫度調(diào)節(jié)器行業(yè)深度研究報告
- 農(nóng)民工考勤表(模板)
- 承臺混凝土施工技術(shù)交底
- 臥床患者更換床單-軸線翻身
- 加強保育員隊伍專業(yè)化建設(shè)提升幼兒園保教質(zhì)量
- 計量基礎(chǔ)知識培訓(xùn)教材201309
- 中考英語 短文填詞、選詞填空練習(xí)
- 一汽集團及各合資公司組織架構(gòu)
- 阿特拉斯基本擰緊技術(shù)ppt課件
- 初一至初三數(shù)學(xué)全部知識點
- 新課程理念下的班主任工作藝術(shù)
- (完整版)企業(yè)破產(chǎn)流程圖(四張)
評論
0/150
提交評論