VascularProtectionTrainingAdvancedClinicalTraining第1頁(yè)TheProductFeaturesandIntendedBenefits第2頁(yè)3of128FilterWireEZ?
EmbolicProtectionSystemTheFilterWireEZSystemisBSC’ssecondgenerationembolicprotectionfilter.ItincorporatesanumberofdesignchangesfromtheFilterWireEX?System(FirstGenerationSystem)intendedtoimprovetheeffectivenessandeaseofuse.EuropeSeptember2023commercializationforSVG,nativecoronary,peripheralandcarotidinterventionDominantmarketshare(PVandCV)despitemanyotherembolicprotectionfiltercompetitorsUSAugust2023commercializationforSVGinterventionIncreasedmarketshareandmarketpenetrationDecember2023510(k)approvedforcarotidindication第3頁(yè)4of128FilterWireEZ?
SystemComponentsFilterWireEZ5.5mmSystemProtectionWireEZDeliverySheathEZRetrievalSheathAccessories
(peel-awayintroducer,guidewiretorquer,valvedilatortool)FilterWireEZBentTipRetrievalSheath
(availableseparately)第4頁(yè)5of128FilterWireEZ?System
AccessoriesPeel-awayIntroducerSheathUsedtopreventdamagetothespringtipoftheprotectionwireduringsysteminsertionintoarotatingorfixedhemostasisvalve.GuideWireTorquerIntendedtoenhancetheoperator’sgripontheprotectionwireforsteerabilityduringdeliveryandtoprovideleverageduringfilterdeploymentandcapture.ValveDilatorToolUsedwithafixedhemostasisvalvetominimizedamagetothefilterbaguponremovalthroughthevalve.第5頁(yè)6of128FilterWireEZ?SystemPEBAXisaregisteredtrademarkofAtofinaCorporationAtraumatic3cm,platinum,springcoiltipwithfloppyflexibilityRadiopaquetoenhancevisualizationShapeabletoenhancesteerability6.0mmPEBAX?NoseconeFlexibletransitionfromthespringtiptothedeliverysheathforexcellentoveralldeliverabilityProvidesaprofiletransitionthatisdesignedtoreducetheriskofdebrisembolizationduringsystemdelivery第6頁(yè)7of128FilterWireEZ?SystemPolyurethanefiltermembranewith110micronporesDesignedtocapturesdebrisandreducetheriskofembolicrelatedeventsIntendedtopermitcontinuousbloodflowforpatientsafetyandcomfortIntendedtopermitcontinuousbloodflowthatallowscontrastinjectionsforvisualizationduringtheintervention第7頁(yè)8of1285.5mm4.5mm3.5mmFilterWireEZ?SystemConforming,nitinolfilterloopwithplatinumcoilHighlyvisibletoguidefilterplacementandtoensuregoodvesselwallappositionOnedevicethataccommodatesvesselswithlandingzonediametersrangingfrom3.5mmto5.5mmminimizessizingguessworkandinventoryneedsDesignedtoprovidecontinuouswallappositionaroundthecircumferenceofthevessellumentominimizetheopportunityfordebristocollectontheoutsideofthefilterAutomaticallyadjuststochangesinthevesselaperture第8頁(yè)9of128FilterWireEZ?SystemFilterloopsuspensionarmallowsthefilterlooptomoveindependentlyfromthewireforgoodvesselwallappositioninbothstraightandcurvedanatomySimplifiesthelandingzonerequirementsbyallowinguseinbothstraightandcurvedvesselsNoneedtotake2angioviewstoassessfilterapposition第9頁(yè)10of128FilterWireEZ?SystemSpinnertubeunderlyingfilterassemblyAllowsthewiretorotateindependentlyfromthedeliverysheathforexcellentsystemsteerability.032”O(jiān)DCatheterstopProvidesabarrierdesignedtopreventtherapeuticdevicesfromcollapsingthefilterframeLightlyvisibletocontributetovisualizationfordevicepositioning**Note:A0.013”O(jiān)Dpart5mmproximaltothecatheterstopmayalsobevisiblewithsomeequipment.Thispartkeepsthespinnertubeinplace,butletscathetertipspassover.第10頁(yè)11of128FilterWireEZ?System0.014”StainlesssteelwirebodywithPTFEcoatingAvailablein190cmand300cmwirelengths190cmwirelengthiscompatiblewithBSC’sAddWire?GuideWireSiliconecoatedondistal15cmofdevice,delivery,andretrievalsheath.Designedtoreducetheamountofforcerequiredtoloadthefilterintothedeliverysheathanddeployinthevessel第11頁(yè)12of128EZ
DeliverySheath150cmPEBAX?Resinsheathwith100cm,peel-awayexchangelengthThedistalsheathchangescolorfrombluetocleartoserveasawarningthatthenonpeel-awaysectionattheendofthesheathisapproaching1.1mm(0.042”or3.2F)LesioncrossingprofileDistalendhasaPTFEinnerlinerInternalstoploadingfeature–alertstheoperatorthatthefilterisfullysheathed第12頁(yè)13of128EZRetrievalSheath150cmPEBAX?Resinsheathwitha20cmlongexchangelengthSoftdistaltipDesignedtofacilitatethecapabilitytocrossdeployedstents1.4mm(0.056”or4.3F)lesioncrossingprofileInternalstopcapturefeatureAlertstheoperatorthatthefilterisfullycaptured第13頁(yè)14of128EZBentTipRetrievalSheath
(soldseparately)150cmPEBAX?Resinsheathwitha20cmexchangelengthBendatdistaltipThebendisdesignedtoaidincrossingstentstrutsthatcancomplicatefilterretrieval1.3mm(0.052”or4.0F)lesioncrossingprofileInternalstopcapturefeatureAlertstheoperatorthatthefilterisfullycaptured第14頁(yè)FilterWireEZ?
EmbolicProtectionSystemStep-by-StepInstructionsProductDemonstrationPleaserefertothe
FilterWireEZ?EmbolicProtectionSystemDFUforcompleteinstructionsforuse.第15頁(yè)FilterWireEZ?EmbolicProtectionSystemDFU
availableat/filterwire
FilterWireEZ?System
DFUCard第16頁(yè)17of128FilterWireEZ?EmbolicProtectionSystem
Pre-ProcedureReviewthepatient’sangiogramanddetermineifthevesselmeetstherequirementsforsafeandeffectiveuseoftheFilterWireEZSystem:Theapexoftheloopcanbedeployedaminimumof3.0cmfromthedistaledgeofthelesion.
Thevesseldiameteratthedesiredlocationofthedeployedfilterloopis3.5mmto5.5mm.(2.25mmto3.5mmforEZSmall)3.5mm–5.5mmvesseldiameter第17頁(yè)18of128FilterWireEZ?EmbolicProtectionSystem
Pre-Procedure(continued)PriortousingtheFilterWireEZSystem,anticoagulatethepatienttoachieveanACTof≥275secondsforcarotidapplicationsand300secondsforSVGapplications(>200secondsifGPIIb/IIIainhibitorsareused).IntheabsenceofACTmeasurement,administeranappropriateweightbasedbolusofheparin(approximately125units/kg).第18頁(yè)19of128FilterWireEZ?EmbolicProtectionSystem
Pre-Procedure(continued)RCAgraft-mostcommonlyusedguideisthemultipurpose.Marginalgraft-HockeystickguideisfirstchoicefollowedbyleftAmplatzLADorDiagonalgraft-mostcommonlyusedguidesaretheleftAmplatzandHockeystick.TakenfromMarcoet.al.“StentingofDegeneratedSaphenousVeinGrafts”May2023EuroPCRBasedonvesseltake-off,physicianshouldconsiderwhichguidecathetershapewillprovidethebestaccessandsupport.第19頁(yè)20of128FilterWireEZ?EmbolicProtectionSystem
PREP:DeliverySystem1.Openthepouchusingsterilehandlingprocedureandplacethepackagingcoilsandaccessorykitintothesterilefield.2.Unclipandremovetheyellowhousingthatprotectsthefilter.
Note:Theprotectionwireispre-loadedintothedeliverysheath.
3.Detachthepre-loaded
protectionwirefromtheretainingclip,advancethedeliverysheath,thengraspthe
clearsectionofthesheath
andremove
sheathedwirefromthecoil.FilterWireEZ?SystemProductPackaging第20頁(yè)21of1284.SheaththeprotectionwireandfilterbyretractingthedeviceintotheEZDeliverySheathwhilethefilterisimmersedinheparinizedsaline.
NOTE:HoldtheDeliverysheathabout1cmproximaltothedarksection.NOTE:Keepthefilterunsheatheduntilimmediatelypriortouse.FilterWireEZ?EmbolicProtectionSystem
PREP:DeliverySystem(continued)3.Attachthewiretorquerontotheproximalendoftheprotectionwire.GuideWireTorquer第21頁(yè)22of128FilterWireEZ?EmbolicProtectionSystem
Delivery2.InserttheFilterWireEZSystemandpeel-awayintroducerassemblyintoaguidecatheter/sheath.OncetheFilterWireEZSystemisinsertedintotheguidingcatheterorguidingsheath,removethepeel-awayintroducer.
NOTE:Useofaguidingcatheteroraguidingsheathwitha1.91mm(0.075”)orlargerrotatinghemostasisvalveisrecommendedwhenperformingaprocedurewiththeFilterWireEZSystem.Theuseofasheath/guidecatheterwithafixedhemostasisvalvemaycausethefiltermembranetotearatthehemostasisvalveuponremoval.1.Placethepeel-awayguidewireintroduceroverthetipofthedeliverysystem(thespringtipofthesystemcanbeshapedasneeded).Peel-awayIntroducerSheath第22頁(yè)23of128FilterWireEZ?EmbolicProtectionSystem
Delivery(continued)3.ToadvancetheFilterWireEZSystemthroughtheguidingcatheterorguidingsheath,useaone-handedtechniqueadvancingboththedeliverysheathandprotectionwiretogether;thiswillpreventaccidentaldeploymentofthefilter.4.TosteertheFilterWireEZSystemtothetargetlandingzone,useatwo-handedtechnique,torquingtheprotectionwirewithonehandandadvancingthedeliverysheathwiththeotherhand.NOTE:Forcarotidinterventions,havingthepatientturntheirheadtotheleftorrightwillchangetheorientationofthevesselandmayfacilitatedevicepassage.
NOTE:Considerusingthebuddywiretechniqueifthelesionisdifficulttopass.RetractthebuddywireafterthelesionhasbeencrossedbytheFilterWireEZSystem(Ifothereffortsareunsuccessful,pre-dilatationcanbeused.)第23頁(yè)24of128FilterWireEZ?EmbolicProtectionSystem
Delivery(continued)5. AdvancetheFilterWireEZSystemacrossthelesionuntiltheapexofthefilterloopcanbedeployedaminimumof3.0cmdistaltothelesion.NOTE:Ifaninterventionaldevicewithatip-to-shoulderlengthofgreaterthan10.0mmistobeused,alongervessellengthmayberequiredtoplacetheFilterWireEZSysteminordertoavoidcontactbetweenthefilter’scatheterstopandthetipoftheinterventionaldevice.第24頁(yè)25of128Oncetheprotectionwireisinplacepastthelesion,slidethetorquertipuptothehemostaticvalveandtightenfirmly.Deploythefilterbyholdingtheprotectionwirewiththetorquer,thenretractingandcompletelyremovingthedeliverysheath.Besuretokeepthetorquerinplaceasyoupeel-awaythedeliverysheathinastraightmotionuntilthe3cmover-the-wiresectionisreached(seephotobelow).FilterWireEZ?EmbolicProtectionSystem
FilterDeploymentincorrectCORRECTPhotographtakenbyBostonScientificCorporation第25頁(yè)26of1284. Oncethedeliverysheathiscompletelyremoved,injectcontrastandverifythedeviceisintheproperpositionandthereisadequateflow.
NOTE:Ifrepositioningisrequired,theEZRetrievalSheathshouldbeused.Retracttheprotectionwireandfilterloopintothesheath,repositionthefilterandredeploy.5. Usetheprotectionwirelikeatraditionalguidewiretotrackcathetersandstentdeliverysystemstothetargettreatmentarea.FilterWireEZ?EmbolicProtectionSystem
FilterDeployment(continued)第26頁(yè)27of1281.Injectcontrastfrequentlyandalwaysafteranyinterventionorexchange,tovisuallyverifythatbloodflowisnotobstructedandthatfilterloop/vesselappositiontothevesselwallismaintained.
CAUTION:Ifafilterbecomesoccludedduringtheprocedure,removeitanddeployasecondfilteriffurtherinterventionisrequired.2.Completetheproceduremakingsuretheprotectionwireremainsintheproperpositiondistaltothelesion(monitorfluoroscopy).
Note:Failuretostabilizetheprotectionwirecouldleadtoinadvertentmovementofthefilter,resultinginprotectionwireentanglementand/ordelayintheprocedure.FilterWireEZ?EmbolicProtectionSystem
DuringtheProcedure第27頁(yè)28of128FilterWireEZ?EmbolicProtectionSystem
FilterCaptureandRetrieval1.RemovetheEZRetrievalSheathfromitspackagingcoilandflushwithheparinizedsaline.2.Advancetheretrievalsheathovertheprotectionwirepastanydeployedstentsuptotheproximalendofthefilterloop.Note:IftheEZRetrievalSheathisnotabletopassthedeployedstent,besurethestentiswellapposedandconsiderpost-dilitation.IftheRetrievalSheathisstillunabletocross,trytheEZBentTipRetrievalSheath(availableseparately).EZBentTipRetrievalSheathPackaging第28頁(yè)29of128FilterWireEZ?EmbolicProtectionSystem
FilterCaptureandRetrieval(continued)3.Gentlyandslowlyretracttheprotectionwireandfilterloopbackintotheretrievalsheathuntilresistanceisfelt.4.Observetheretrievalprocedureunderfluoroscopicimaging.Note:Thedistaledgeofthecollapsedfilterloopshouldalignwith(seefigureB),orbeproximalto(figureA),theretrievalsheathmarkerband.
RetrievalSheathMarkerBandAB第29頁(yè)30of128FilterWireEZ?EmbolicProtectionSystem
FilterCaptureandRetrieval(continued)
NOTE:Ifresistanceisfeltbeforethedistaledgeofthecollapsedfilterloopisalignedwiththemarkerband,itispossiblethatthereisalargeamountofembolicdebrisinthefilter.CarefullyretracttheprotectionwireandEZRetrievalSheathasasystem.Thedistalpartofthefilterbagwillbeoutsideofthesheathduringretrievalinthiscase;however,thefilterloopmustbepulledfullyintothesheath.FullyRetractedFilterLargeDebrisLoadinFilter第30頁(yè)31of128FilterWireEZ?EmbolicProtectionSystem
FilterCaptureandRetrieval(continued)5.IfanyresistanceismetduringretractionofthesheathedFilterWireEZSystem,slightlyadvancethesheathedFilterWireEZSystemandrotatethesheathbeforecontinuingtoretract.6.Slowlyandcarefullyretracttheentiresystemuntilthetipoftheretrievalsheathisadjacenttothetipoftheguidingcatheterorguidingsheath.7. Ifthereisanyresistance,retracttheguidingcatheterandFilterWireEZSystemtogether.Thisisdoneincasethereisalargeamountofembolicmaterialcapturedinthefilterthatmaynotfitinsidetheguidingcatheter.第31頁(yè)32of128FilterWireEZ?EmbolicProtectionSystem
FilterCaptureandRetrieval(continued)8.RemovetheFilterWireEZSystemfromthepatient. NOTE:Whenusinga
rotatinghemostasisvalve,ensurethatthehemostasisvalveisfullyopenedpriortoFilterWireEZSystemremoval.
CAUTION:Ifaguidesheathwithafixedhemostasisvalveisused,thevalvedilatortoolisrequiredforFilterWireEZSystemremoval.RemovingtheFilterWireEZSystemthroughafixedhemostasisvalvewithouttheuseofavalvedilatormaycausethefiltermembranetotear.9.Ifafixedhemostasisvalveisused,placethevalvedilator(ifprovidedintheaccessorykit)ontheshaftoftheretrievalsheathandslidethetoolintothevalve.ThenremovetheFilterWireEZSystemfromthepatientthroughthevalvedilatortoolandremovethedilator.第32頁(yè)33of128StentEntanglementPotentialforadistalembolicprotectionfiltertoentanglewithastentisinherenttointerventionalproceduresusingthesedevices.SAFEPRACTICEFORDISTALPROTECTIONFILTERS:AchievegoodguidecatheterorguidesheathsupportEnsuresufficientlandingzoneKeepthefilterinplaceduringdeploymentMinimizewiremovementduringtheprocedureAchievefullstentapposition第33頁(yè)34of128FilterWireEZ?EmbolicProtectionSystem
TipsforUseKeySuccessFactorsforUsingtheFilterWireEZSystemKeepACTlevels275secondsforcarotidproceduresand300secondsforSVGprocedures.Ifthereisdifficultycrossingthelesion,tryabuddywireand/or,forcarotidprocedures,havethepatientturntheirheadtotheleftorright.Forcarotidprocedures,placethefilterasdistalaspossiblewhileremainingwithintheextracranialportionoftheICA.Duringdeploymentandexchanges,stabilizethewireandwipeitfrequentlytodecreasefriction.Keepyoureyeonthefilter!Knowwhereitisandknowwhereitissupposedtobe.Verifyflowoften.Slowflow?Finishtheprocedureandremove.Noflow?Removeandreplace.TheFilterWireEZSystemneedsflowtofunction.Donottreatthelesionor“touchup”withoutaFilterWireEZSysteminplace.第34頁(yè)CompetitionRXACCUNET?(Abbott)Angioguard(Cordis)Emboshield?System(Abbott)Spider(ev3)第35頁(yè)36of128Competition
FixedWireFilters‘SheathedFixedWire’Devices:FilterWireEZ?System,RXAccunet?,Characteristics
Filterattachedtoa proprietarywireDeliverysheathrequiredPhotobyBostonScientific第36頁(yè)37of128Competition
WireofChoiceFilters‘WireofChoice’Device:SpiderFX?Device, EmboshieldCharacteristics:Useany.014”wiretogainaccessDeliversheathedfilterandproprietaryguidewireoverthe‘wireofchoice’,thenremove‘wireofchoice’Wirecanmoveslightly(~8mmoflongitudinal“play”)withoutmovingfilterCANNOTremove/replacedeployedfilterwhilemaintainingaccessSpideRX?第37頁(yè)38of128Competition
OcclusiveDevicesDistalOcclusionDevice:MedtronicGuardWire?SystemCharacteristics:ProprietarywirewithballoonattachedLowcrossingprofileBallooninflateddistaltolesionShortlandingzoneAspiratetoremoveemboliProximalOcclusionDevices:St.JudeProxis?System
CharacteristicsOcclusiveprotectionpriortocrossinglesionProxisstopsflowandthenaspiratestoremoveemboliProxis?GuardWire?第38頁(yè)ImagebyBostonScientificCorp.AbbottVascularDevicesRXACCUNET?EmbolicProtectionSystem第39頁(yè)40of128Competition
RXACCUNET?SystemDeliveryRetrievalFilterBagDeliverymethod:SheathedwireImagesbyBostonScientificCorp.第40頁(yè)Competition
RXACCUNET?SystemFilterSizeFullyExpandedReferenceVesselDiameter(MintoMaxRange)MinimumSheathSizeMINIMUMGUIDINGCATHETERSIZE4.5mm3.25mm–4.0mm6F8F5.5mm4.0mm–5.0mm6F8F6.5mm5.0mm–6.0mm6F8F7.5mm6.0mm–7.0mm6F8FTechnicalspecsexcerptedfromRXACCUNETSystemDirectionsforUseandotherliteraturepublishedbyAbbottVascularatasofMarch10,2023第41頁(yè)42of128Competition
RXACCUNET?SystemFilterWireEZSystemRXACCUNETSystemDeliveryMethodSheathedwireSheathedwireCrossingProfile3.2F3.5&3.7FDistalTip3.0cm3.0cmVesselDiameterCoverage3.5mm–5.5mm3.25mm–7.0mm(4sizes–4.5,5.5,6.5,7.5)PoreSize110micronRangesupto150micronDeviceWireCharacteristicsModeratesupportExtrasupportLandingZone>3.0cm>4.0cmAppositionCheck1view2viewsRetrievalSheathProfile4.3F5.5FWireLengths190cm,300cm190cm,300cmGuideCatheterReq.6F(minID0.066”)8F(minID0.085”)IndicationsCarotid,SVGCarotidInformationexcerptedfromFilterWireEZSystemandRXACCUNETSystemDirectionsforUseandotherliteraturepublishedbyAbbottVascularatasofMarch10,2023第42頁(yè)43of128ExcellentDeliverabilityGuidewireanddeliverysheathentervesselasoneunitHighlyflexibletonavigatetortuousanatomyLowprofileandsmoothtransitionfromtiptofilterbasket.014”wireistorquedindependentfromfilterbasketAccurateDeploymentRapidexchangeunsheathingforstabilityandsimplicityPeelawaydeliverysheathallowsforcontrolleddeploymentCaptureandControlforOptimalProtectionHighlyflexiblefilterbasketdesignedtoconformtotortuosityDesignedtocapturehighvolumewhileallowingadequatebloodflowConcentricdesignwithguidewirecenteredinfilterFourplatinumradiopaquemarkerssurroundfilterforvisualizationofwallappositionSecureFilterRetrievalChoiceoftworapidexchangerecoverycathetersdesignedspecificallyforthechallengesoffilterrecovery.RXACCUNETRecoveryCatheterShapeabledistaltipsteerscatheterfromstentstrutsduringadvancementFilterbasketsecuredwithallcagestrutopeningsenclosedduringwithdrawalRXACCUNET2RecoveryCatheterLow-profile,flexibletiptoallowfordeflectionawayfromstentstrutsduringadvancementFlexiblecatheter/shaftoptimizedforchallengingguidecatheter/sheathaccessCathetershaftmarkersat95and105cmforreducedflourotimeCompetition
RXACCUNET?SystemInformationononRXACCUNETSystemexcerptedfromliteraturepublishedbyAbbottVascularat.第43頁(yè)44of128ACCUrateCaptureandControlTheRXACCUNETSystemisdesignedtoprovideexcellentcapturecapabilitiesandeasyfiltercontrolwhenperformingcarotidstentinginterventions.TheRXACCUNETSystemisa.014”guidewirebasedfiltersystemthatutilizesrapidexchangetechnologysothatthephysiciancaneasilycontrolthefilterduringcathetermanipulations.Itisavailableinboth190cmand300cmlengthswiththeproximalendofthe190cmdevicecoinedtoallowforattachmenttoa“DOC”wireextension.Thesystemis6Fsheath/8Fguidecathetercompatibleandhasfiltersavailablein4.5,5.5,6.5,and7.5mmbasketdiametersthatarerecommendedforuseinarteriesrangingfrom3.25mmto7.0mm.TheRXACCUNETSystem’sflexiblecagedesignassistsinmaintainingexcellentwallappositioninpulsedflowenvironmentsandchallenginganatomies.TheRXACCUNETSystem’speelawaydeliverysheathallowsforsimpledeploymentwithrapidexchangeunsheathingforstabilityandeaseofuse.Additionally,the.014”wirecanbetorquedindependentlyfromthefilterbasketinordertohelpmanagethenavigationoftortuousanatomy.RecoveryisperformedwithachoiceoftwodedicatedRXrecoverycatheters.
TheoriginalRXACCUNETRecoveryCatheterhasashapeabledistaltipdesignedtooffersteeringcontrolduringadvancement.TheRXACCUNET2RecoveryCatheterislowerprofileandmoreflexibleandwasdesignedtoaccessmoretortuousanatomieswithoutcatchingonstentstruts.Competition
RXACCUNET?System
-PositioningInformationonRXACCUNETSystemexcerptedfromliteraturepublishedbyAbbottVascularandmadeavailableatasofMarch10,2023第44頁(yè)ImagebyBostonScientificCorp.AbbottVascularDevicesEmboshield?BareWire?RapidExchangeEmbolicProtectionSystem第45頁(yè)46of128Competition
Emboshield?SystemDeliverymethod:BareWire?Device/wirefirstCrosslesionwithprovided
BareWireDevice,thenadvanceFilterDeliveryCatheteroverBareWireDevicetodeploymentsite(note:thefiltercanonlybepositionedproximaltothe0.019”stepontheBareWireDevice)DeliveryRetrievalFilterBagImagesbyBostonScientificCorp.InformationexcerptedfromEmboshieldSystemDFU.第46頁(yè)Competition
Emboshield?SystemFilterDiameterVesselSizeRangeCrossingProfile3.0mm2.8-<3.5mm3.7F4.0mm3.5-<4.2mm3.7F5.0mm4.2-<5.2mm3.9F6.0mm5.2–6.2mm3.9FSupportLevelLength(cm)Soft190,315Medium190,315Extra190,315Super190,315Maximum190,315Emboshield?SystemBareWireTechnicalspecsexcerptedfromEmboshieldSystemDirectionsforUseandotherliteraturepublishedbyAbbottVascularandmadeavailableatasofMarch10,2023第47頁(yè)48of128Competition
Emboshield?SystemFilterWireEZSystemEmboshieldSystemDeliveryMethodSheathedfilterwireBareWire?Device/wirefirstCrossingProfile3.2F3.7&3.9FDistalTip3.0cm3.0cmVesselDiameterCoverage3.5mm–5.5mm2.8–6.2mm(4sizes–3,4,5,6)PoreSize110micron140micronDeviceWireCharacteristicsModeratesupport5supportlevels(soft,medium,extra,super,maximum)LandingZone>3.0cm>3.6–4.3cmAppositionCheck1view2viewsRetrievalSheathProfile4.3F5.4FWireLengths190cm,300cm190cm,315cmGuideCatheterReq.6F(minID0.066”)7FIndicationsCarotid,SVGCarotidInformationexcerptedfromFilterWireEZSystemandEmboshieldSystemDirectionsforUseandotherliteraturepublishedbyAbbottVascularandavailableatAsofMarch10,2023.第48頁(yè)49of128Competition
Emboshield?SystemPerceivedStrengthsPerceivedWeaknessesAbilitytocrosstightlesionsusingarelativelysimplesystem(providedguidewirewith0.019”stop)Lowcaptureefficiencyonabend1Abilitytoretrievethefilterwhileleavingthewireinplace.Significantforceisrequiredtodeliverthedevice2Multiplesizeswithvesselcoverageof2.8to6.2mmdiameterLimitedradiopacityRequirescrossingthelesiontwicepriortoprotection–firstwithBareWireandthenw/deliverycatheterIncreasedproceduraltimeLargelandingzonerequiredImagesbyBostonScientificCorp.第49頁(yè)50of128InformationonEmboshieldSystemexcerptedfromliteraturepublishedbyAbbottVascularandmadeavailableatasofMarch10,2023Competition
Emboshield?System-PositioningDesignedforChoice,Safety,ConfidenceWiththeBareWire?Device,thewirecrossesthelesionfirst,independentofthefilteranddeliverycatheter.Allotheractions,includingfilterplacementandretrieval,balloondilatations,andstentplacementthenoccuroverthewire.
CHOICEFiveDifferentWireSupportLevelsEachavailableintwolengthsofferlesion-specificaccessandsupportTheSupersupportBareWireDeviceispackagedwiththe EmboshieldSystemSAFETYOptimizedFitofRetrievalCathetertoWireSnugfitofcathetertiptowireenhancestrackabilityand reducesthelikelihoodofcatchingonthestent.CompleteFilterEncapsulationforthesecureremovalofdebrisEmboshield
SystemenablescompleteretrievalforthesecureremovalofdebrisCONFIDENCESupportLevelSoftMediumExtraSuperMaximum第50頁(yè)SpiderFXDevicepictureexcerptedfromliteraturepublishedbyeV3andmadeavailableatasofMarch10,2023ev3SpiderFX?
EmbolicProtectionDevice第51頁(yè)52of128FilterBag:
Notethenitinolfiltermeshporesizevariesdistaltoproximal.Guidewire:
Notethedeliverysheathdoesnothavea“nosecone”thustheleadingedgeisbluntvs.tapered.Delivery:
Notethefiltersitsjustbehindtherapidexchangeportduringdeliveryoverthepreviouslyplacedguidewire.Thatwireisremovedoncethefiltersystemisdeliveredpastthelesion.BluntedgeofdeliverysheathFilterCompetition
SpideRX?DeviceDeliverymethod:Physicianpreferred.014”or.018”guidewireSystemisprovidedinasinglepackaginghoop,withCaptureWire/Filterpre-loadedintheDeliveryEndoftheSpideRXCatheterRetrievalImagesbyBostonScientificCorp.第52頁(yè)Competition
SpiderFX?DeviceFilterSize(mm)VesselSizeRange(mm)WireLength(cm)CrossingProfile(Fr)GuideCatheter(minID)3.03.0190/3203.26F(0.066”)4.03.1-4.0190/3203.26F(0.066”)
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 豬場(chǎng)購(gòu)銷合同(2篇)
- 生產(chǎn)承包合同(2篇)
- 二年級(jí)少先隊(duì)工作計(jì)劃
- 蘇教版二年級(jí)數(shù)學(xué)上冊(cè)期末復(fù)習(xí)口算練習(xí)題一
- 建委房屋出租合同范本
- 校園大樹修剪合同范本
- 八年級(jí)道德與法治下冊(cè)第三單元人民當(dāng)家作主第五課我國(guó)基本制度第3框基本政治制度(第2課時(shí)民族區(qū)域自治制度、基層群眾自治制度)聽課評(píng)課記錄(新人教版)
- 美容院會(huì)員合同范本
- 2025年度單位食堂承包及員工心理咨詢服務(wù)協(xié)議
- 二零二五年度設(shè)備搬運(yùn)與施工安全防護(hù)合同模板
- 運(yùn)動(dòng)技能學(xué)習(xí)與控制課件第一章運(yùn)動(dòng)技能學(xué)習(xí)與控制概述
- 固體廢棄物檢查記錄
- 工程設(shè)計(jì)費(fèi)取費(fèi)標(biāo)準(zhǔn)
- GB/T 5465.1-2009電氣設(shè)備用圖形符號(hào)第1部分:概述與分類
- 2023年遼寧鐵道職業(yè)技術(shù)學(xué)院高職單招(數(shù)學(xué))試題庫(kù)含答案解析
- CAPP教學(xué)講解課件
- 自然環(huán)境的服務(wù)功能課件 高中地理人教版(2019)選擇性必修3
- 小耳畸形課件
- 新人教版初中初三中考數(shù)學(xué)總復(fù)習(xí)課件
- 機(jī)械制造有限公司組織架構(gòu)圖模板
- 8.3 摩擦力 同步練習(xí)-2021-2022學(xué)年人教版物理八年級(jí)下冊(cè)(Word版含答案)
評(píng)論
0/150
提交評(píng)論