1、.砌體結(jié)構(gòu)課程設(shè)計(jì)指導(dǎo)書(shū)土木教研室2013.9民用房屋墻體及條形基礎(chǔ)設(shè)計(jì)1 本課程設(shè)計(jì)的基本要求(1)根據(jù)房屋的使用性質(zhì)和各種承重方案的特點(diǎn),選擇合理的承重方案,進(jìn)行墻體布置,同時(shí)根據(jù)材料的供應(yīng)情況,選擇砌體的類型。(2) 根據(jù)屋(樓)蓋類別和橫墻間距確定房屋的靜力計(jì)算方案,然后縱、橫墻進(jìn)行高厚比驗(yàn)算。對(duì)于帶壁柱或帶構(gòu)造柱的墻,除了驗(yàn)算整片墻的高厚比外,還應(yīng)驗(yàn)算壁柱間墻或構(gòu)造柱間墻的局部高厚比。(3) 選擇有代表性或受力較不利的開(kāi)間墻、柱作為計(jì)算單元,確定墻、柱計(jì)算簡(jiǎn)圖,選擇最不利截面,計(jì)算控制截面內(nèi)力,然后驗(yàn)算墻、柱受壓承載力。(4) 房屋中設(shè)有屋(樓)面梁時(shí),尚應(yīng)驗(yàn)算梁端下砌體的局部受壓承

2、載力;梁端下因構(gòu)造要求或?yàn)榱颂岣咂鲶w局部受壓承載力設(shè)置墊塊或墊梁時(shí),尚應(yīng)驗(yàn)算墊塊或墊梁下砌體的局部受壓承載力。(5) 為了滿足正常使用極限狀態(tài)的要求,墻體尚應(yīng)滿足相應(yīng)的構(gòu)造要求。(6) 根據(jù)工程地質(zhì)勘察報(bào)告確定基礎(chǔ)埋置深度、地基承載力,然后按地基承載力要求計(jì)算基礎(chǔ)底面尺寸,最后按剛性角要求確定基礎(chǔ)高度,繪制基礎(chǔ)施工圖。2 承重墻體的布置和房屋靜力計(jì)算方案的確定2.1 承重墻體的布置混合結(jié)構(gòu)房屋承重墻的布置不僅影響房屋的平面劃分和房間的大小,而且還影響房屋的空間剛度。承重墻體布置方案有四種,即橫墻承重、縱墻承重、縱橫墻承重及內(nèi)框架承重。其中,橫墻承重結(jié)構(gòu)主要用于房間大小固定、橫墻間距較密的住宅、

3、宿舍、旅館以及辦公樓房屋中,縱墻承重結(jié)構(gòu)主要用于開(kāi)間較大的教學(xué)樓、醫(yī)院、食堂、倉(cāng)庫(kù)等房屋中;縱橫墻承重結(jié)構(gòu)主要用于多層塔式住宅等房屋中;內(nèi)框架承重結(jié)構(gòu)主要用于商場(chǎng)、餐廳以及多層工業(yè)廠房等房屋中。2.2 房屋靜力計(jì)算方案的確定房屋靜力計(jì)算方案,實(shí)際上是通過(guò)對(duì)房屋空間受力性能的分析,根據(jù)房屋空間剛度的大小確定墻、柱設(shè)計(jì)時(shí)的計(jì)算簡(jiǎn)圖,同時(shí)也是墻、柱承載力計(jì)算和構(gòu)造措施的主要依據(jù)。根據(jù)影響房屋空間剛度的兩個(gè)主要因素,即屋蓋或樓蓋的類別和橫墻的間距,砌體結(jié)構(gòu)設(shè)計(jì)規(guī)范(GB 5003-2011)將房屋靜力計(jì)算方案分為三種,即剛性方案、彈性方案以及剛彈性方案,可按表2-1確定。表2-1 房屋靜力計(jì)算方案屋蓋

4、或樓蓋類別剛性方案剛彈性方案彈性方案1整體式、裝配整體和裝配式無(wú)檁體系鋼筋混凝土屋蓋或鋼筋混凝土樓蓋s<3232s72s>722裝配式有檁體系鋼筋混凝土屋蓋、輕鋼屋蓋和有密鋪望板的木屋蓋或木屋蓋s<2020s48s>483瓦材屋面的木屋蓋和輕鋼屋蓋s<1616s36s>36注:1. 表中s為房屋橫墻間距,其長(zhǎng)度單位為m;2. 對(duì)無(wú)山墻或伸縮縫處無(wú)橫墻的房屋,應(yīng)按彈性方案考慮。3 墻、柱高厚比驗(yàn)算墻、柱高厚比驗(yàn)算是確保砌體結(jié)構(gòu)穩(wěn)定、滿足正常使用極限狀態(tài)要求的重要構(gòu)造措施之一。3.1 矩形截面墻、柱高厚比的驗(yàn)算矩形截面墻、柱高厚比應(yīng)按下式驗(yàn)算: (3-1)式中:

5、H0墻柱的計(jì)算高度,按表3-1確定;h墻厚或矩形柱與相對(duì)應(yīng)的邊長(zhǎng);墻、柱的允許高厚比,按表2-3確定。表3-1 受壓構(gòu)件的計(jì)算高度H0房屋類別柱帶壁柱墻或周邊拉接的墻排架方向垂直排架方向s2H2HsHsH有吊車的單層房屋變截面柱上段彈性方案2.5Hu1.25Hu2.5Hu剛性、剛彈性方案2.0Hu1.25Hu2.0Hu變截面柱下段1.0Hu無(wú)吊車的單層和多層房屋單跨彈性方案1.5H1.0H1.5H剛彈性方案1.2H1.0H1.2H多跨彈性方案1.25H1.0H1.25H剛彈性方案1.10H1.0H1.1H剛性方案1.0H1.0H1.0H0.4s+0.2H0.6s注:1. 表中為變截面柱的上段高

6、度;為變截面柱的下段高度;2. 對(duì)于上墻為自由端的構(gòu)件,H0=2H;3. 獨(dú)立磚柱,當(dāng)無(wú)柱間支撐時(shí),柱在垂直排架方向的H0應(yīng)按表中數(shù)值乘以1.25后采用;4. s為房屋橫墻間距;5. 自承重墻的計(jì)算高度應(yīng)根據(jù)周邊支承或拉接條件確定。表3-2 墻、柱的允許高厚比值砌體類型砂漿強(qiáng)度等級(jí)墻 柱無(wú)筋砌體M2.5M5.0或Mb5.0、Ms5.0M7.5或Mb7.5、Ms7.5222426151617配筋砌塊砌體3021注:1. 毛石墻、柱允許高厚比應(yīng)按表中數(shù)值降低20; 2. 砌體和鋼筋帶有混凝土或砂漿面層的組合磚砌體構(gòu)件的允許高厚比,可按表中數(shù)值提高20,但不得大于28; 3. 驗(yàn)算施工階段砂漿尚未硬

7、化的新砌砌體構(gòu)件高厚比時(shí),允許高厚比對(duì)墻取14,對(duì)柱取11。 自承重墻(h240 mm)允許高厚比修正系數(shù),按下列規(guī)定采用: 當(dāng)h=240 mm時(shí),=1.2; 當(dāng)h=90 mm時(shí),=1.5; 當(dāng)240 mm h 90 mm時(shí),可按插入法取值。有門窗洞口的墻體允許高厚比的修正系數(shù),應(yīng)按式(3-2)計(jì)算,即 (3-2)式中:在寬度范圍內(nèi)的門窗洞口總寬度; 相鄰窗間墻或壁柱之間的距離。 當(dāng)按式3-2計(jì)算的值小于0.7時(shí),取0.7;當(dāng)洞口高度等于或小于墻高的1/5時(shí),可取=1.0。3.2 帶壁柱墻的高厚比驗(yàn)算對(duì)于帶壁柱的墻體,需分別對(duì)整片墻和壁柱間墻進(jìn)行高厚比驗(yàn)算。3.2.1 整片墻的高厚比驗(yàn)算 對(duì)于

8、帶壁柱墻,由于其截面為T形,因此按式(3-1)驗(yàn)算高厚比時(shí),公式中應(yīng)改為用帶壁柱墻截面的折算厚度,即 (3-3)式中:帶壁柱墻截面的折算厚度,=3.5i; 帶壁柱墻截面的回轉(zhuǎn)半徑,;I、A分別為帶壁柱墻截面的慣性矩和面積。確定帶壁柱墻的計(jì)算高度時(shí),墻長(zhǎng)取相鄰橫墻間的距離。3.2.2 壁柱間墻的高厚比驗(yàn)算驗(yàn)算壁柱間墻的高厚比時(shí),可將壁柱視為壁柱間墻的不動(dòng)鉸支點(diǎn),按矩形截面墻驗(yàn)算。確定墻體計(jì)算高度時(shí),墻長(zhǎng)取相鄰壁柱間的距離。3.3 帶構(gòu)造柱墻高厚比驗(yàn)算 對(duì)于帶構(gòu)造柱的墻體,亦需分別對(duì)整片墻和構(gòu)造柱間墻進(jìn)行高厚比驗(yàn)算。3.3.1 整片墻的高厚比驗(yàn)算當(dāng)構(gòu)造柱截面寬度不小于墻厚h時(shí),可按式(3-4)驗(yàn)算

9、帶構(gòu)造柱墻的高厚比,即 (3-4)式中:設(shè)構(gòu)造柱墻體允許高厚比的修正系數(shù),按下式計(jì)算: (3-5)其中:系數(shù),對(duì)細(xì)料石砌體,;對(duì)混凝土砌塊、混凝土多孔磚、粗料石、毛料石及毛石砌體,;其他砌體,; 構(gòu)造柱沿墻長(zhǎng)方向的寬度; 構(gòu)造柱的間距。當(dāng)時(shí)取;當(dāng)時(shí)取。確定墻體計(jì)算高度時(shí),s取相鄰橫墻間的距離,h取墻厚。3.3.2 構(gòu)造柱間墻的高厚比驗(yàn)算驗(yàn)算構(gòu)造柱間墻的高厚比時(shí),亦可將構(gòu)造柱視為構(gòu)造柱間墻的不動(dòng)鉸支點(diǎn),按矩形截面墻驗(yàn)算。確定墻體計(jì)算高度時(shí),墻長(zhǎng)s取相鄰構(gòu)造柱間的距離。4 承重墻的計(jì)算承重墻的計(jì)算包括下列幾個(gè)步驟:首先選取墻體的計(jì)算單元和計(jì)算截面,然后確定計(jì)算簡(jiǎn)圖并進(jìn)行墻體內(nèi)力分析,最后驗(yàn)算墻體的

10、受壓承載力。墻體中設(shè)有樓(屋)面梁時(shí),尚應(yīng)驗(yàn)算梁端支承處砌體的局部受壓承載力;梁端下設(shè)有墊塊或墊梁時(shí),則應(yīng)驗(yàn)算墊塊或墊梁下砌體的局部受壓承載力。4.1 墻體計(jì)算單元和計(jì)算截面對(duì)于承重縱墻,常選取一個(gè)有代表性或較不利的開(kāi)間墻作為墻體計(jì)算單元,其承受荷載范圍的寬度取相鄰兩開(kāi)間的平均值,長(zhǎng)度取進(jìn)深的一半。對(duì)于承重橫墻,常沿墻軸線取寬度為1.0m的墻作為墻體計(jì)算單元,其承受荷載范圍的寬度取1.0m,長(zhǎng)度取相鄰兩開(kāi)間的平均值。確定墻體計(jì)算截面的關(guān)鍵在于正確取用截面翼緣寬度,按下列原則確定:(1)多層房屋中,當(dāng)有門窗洞口時(shí),帶壁柱墻的計(jì)算截面翼緣寬度可取窗間墻寬度;當(dāng)無(wú)門窗洞口時(shí),每側(cè)翼緣寬度可取壁柱高度

11、的1/3;(2)單層房屋中,帶壁柱墻的計(jì)算截面翼緣寬度可取壁柱寬度加2/3墻高,但不大于窗間墻寬度和相鄰壁柱間距離;(3)計(jì)算帶壁柱墻的條形基礎(chǔ)時(shí),計(jì)算截面翼緣寬度可取相鄰壁柱間的距離;(4)當(dāng)轉(zhuǎn)角墻段角部受豎向集中荷載時(shí),計(jì)算截面的長(zhǎng)度可從角點(diǎn)算起,每側(cè)宜取層高的1/3。當(dāng)上述墻體范圍內(nèi)有門窗洞口時(shí),則計(jì)算截面取至洞邊,但不宜大于層高的1/3。4.2 計(jì)算簡(jiǎn)圖和內(nèi)力分析4.2.1 單層剛性方案房屋墻、柱單層剛性方案房屋墻、柱可視為上端不動(dòng)鉸支承于屋(樓)蓋處、下端嵌固于基礎(chǔ)的豎向構(gòu)件。圖4-1a為某單層剛性方案房屋計(jì)算單元內(nèi)墻、柱的計(jì)算簡(jiǎn)圖。作用于墻、柱上的荷載有兩種,即豎向荷載和風(fēng)荷載。其

12、中,豎向荷載包括屋蓋自重、屋面活荷載或雪荷載以及墻、柱自重。屋面荷載通過(guò)屋架或大梁作用于墻體頂部,其作用位置如圖4-1b所示,存在偏心距;墻、柱自重則作用于墻、柱截面的重心。豎向荷載作用下墻、柱的內(nèi)力如圖4-1c所示,分別為 (4-1)圖4-1 單層剛性方案房屋墻、柱內(nèi)力分析 風(fēng)荷載又分為屋面風(fēng)荷載和墻面風(fēng)荷載兩部分。其中,屋面風(fēng)荷載最后以集中力通過(guò)不動(dòng)鉸支點(diǎn)由屋面復(fù)合梁傳給橫墻,不會(huì)對(duì)墻、柱的內(nèi)力造成影響。墻面風(fēng)荷載作用下墻、柱內(nèi)力如圖4-1d所示,分別為 (4-2)計(jì)算時(shí),迎風(fēng)面,背風(fēng)面。4.2.2 多層剛性方案房屋承重縱墻豎向荷載作用下,多層剛性方案房屋承重縱墻在每層高度范圍內(nèi)可近似地視

13、作兩端鉸支的豎向構(gòu)件,其計(jì)算簡(jiǎn)圖如圖4-2c所示;水平荷載作用下,多層剛性方案房屋承重縱墻則視作豎向連續(xù)梁,其計(jì)算簡(jiǎn)圖如圖4-2e所示。承重縱墻的控制截面取每層墻的上、下端II和IIII截面,如圖4-2b所示。圖4-2 多層剛性方案房屋計(jì)算簡(jiǎn)圖每層承重縱墻承受的豎向荷載包括上面樓層傳來(lái)的豎向荷載Nu、本層傳來(lái)的豎向荷載和本層墻體自重NG。 作用位置如圖4-3所示。其中,Nu作用于上一樓層墻體截面的重心 處; 距離墻內(nèi)邊緣的距離取0.4a0(a0為有效支承長(zhǎng)度);NG則作用于本層墻體截面重心處。圖4-3 作用位置作用于每層墻體上端截面II的軸向壓力為和偏心距分別為 (4-3) (4-4) 式中:

14、對(duì)本層墻體重心軸線的偏心距;上、下層墻體重心軸線之間的距離。每層墻體的彎矩圖為三角形,如圖4-2d所示。上下截面I-I的彎矩,軸向壓力;下截面II-II的彎矩圖,軸向壓力。其中,截面I-I的彎矩最大,軸向壓力最?。唤孛鍵I-II的彎矩最小,而軸向壓力最大。水平風(fēng)荷載引起的彎矩(圖4-2e)可近似按下式計(jì)算 (4-5)式中:計(jì)算單元每層高墻體上作用的風(fēng)荷載;層高。4.2.3 多層剛性方案房屋承重橫墻多層剛性方案房屋承重橫墻的計(jì)算原理與承重縱墻相同,不同的是前者常沿軸線取寬度為1.0m的墻體作為計(jì)算單元,如圖4-4a所示。當(dāng)橫墻的砌體材料和墻厚相同時(shí),可只驗(yàn)算底層截面II-II處的承載力(圖4-4

15、b)。當(dāng)橫墻的砌體材料或墻厚改變時(shí),尚應(yīng)對(duì)改變處進(jìn)行承載力驗(yàn)算。當(dāng)左、右兩開(kāi)間不等或樓面荷載相差較大時(shí),尚應(yīng)對(duì)上端截面I-I按偏心受壓進(jìn)行承載力驗(yàn)算。當(dāng)樓面梁支承于橫墻上時(shí),還應(yīng)驗(yàn)算梁端下砌體的局部受壓承載力。 圖4-4 橫墻計(jì)算簡(jiǎn)圖 4.2.4 單層彈性方案房屋承重墻單層彈性方案房屋承重墻的計(jì)算簡(jiǎn)圖如圖4-5a所示,其內(nèi)力按屋架或屋面大梁與墻為鉸接且不考慮空間工作的平面排架確定,其方法與鋼筋混凝土單層工業(yè)廠房排架相同,如圖4-5b、c所示。單層彈性方案房屋承重墻的控制截面有兩個(gè),即墻頂和墻底截面,均按偏心受壓驗(yàn)算墻體的承載力。對(duì)于變截面柱,還應(yīng)驗(yàn)算變截面處截面的受壓承載力。 圖4-5 彈性方

16、案房屋墻、柱內(nèi)分析4.2.5 單層剛彈性方案房屋承重墻單層剛彈性方案房屋承重墻的計(jì)算簡(jiǎn)圖如圖4-6a所示。與單層彈性方案房屋承重墻計(jì)算簡(jiǎn)圖的主要區(qū)別在于柱頂附加了一個(gè)彈性支座,其內(nèi)力分析如同一平面排架,只是引入以反映結(jié)構(gòu)的空間作用,為房屋的空間性能影響系數(shù),查表4-1確定。表4-1 房屋各層的空間性能影響系數(shù)屋蓋或樓蓋類別橫 墻 間 距 s/m16202428323640444852566064687210.330.390.450.500.550.600.640.680.710.740.7720.350.450.540.610.680.730.780.8230.370.490.600.680.

17、750.81注:i取1n,n為房屋的層數(shù)。水平風(fēng)荷載作用下,剛彈性方案房屋承重墻、柱的內(nèi)力可按下列步驟計(jì)算:(1)在排架柱頂端附加一個(gè)不動(dòng)鉸支承,按無(wú)側(cè)移排架求出荷載作用下的支座反力和柱頂剪力(圖4-6b、d),即 (4-6) (4-7)圖4-6 單層剛彈性方案房屋墻、柱內(nèi)分析(2)將反方向施加在排架柱頂(圖4-6c),然后按剪力分配法計(jì)算墻、柱內(nèi)力。此時(shí),柱頂剪力(4-6e)為 (4-8)(3)將上述兩種情況的內(nèi)力疊加,即可得到單層剛彈性方案房屋墻、柱的最后內(nèi)力(圖4-6f)。柱頂剪力、柱底彎矩分別為 (4-9) (4-10)豎向?qū)ΨQ荷載作用下,無(wú)論是彈性方案還是剛彈性方案房屋,其墻、柱的內(nèi)

18、力計(jì)算方法均與剛性方案房屋相同。4.2.6 多層剛彈性方案房屋承重墻豎向荷載作用下,由于各樓層側(cè)移較小,為簡(jiǎn)化計(jì)算,多層剛彈性方案房屋承重墻的內(nèi)力可按剛性方案房屋的方法進(jìn)行分析。水平荷載作用下,多層剛彈性方案承重墻的計(jì)算簡(jiǎn)圖如圖4-7所示,其內(nèi)力分析方法與單層剛彈性方案房屋的方法相似。圖4-7 多層剛彈性方案房屋的計(jì)算簡(jiǎn)圖4.3 承重墻受壓承載力驗(yàn)算 承重墻受壓承載力按下式驗(yàn)算 (4-11) 式中:軸向壓力設(shè)計(jì)值; 高厚比和軸向壓力偏心距e對(duì)受壓構(gòu)件承載力的影響系數(shù),查表4-2表 4-4確定; 砌體抗壓強(qiáng)度設(shè)計(jì)值,查表4-5表4-11確定; 截面面積,對(duì)各類砌體均應(yīng)按毛截面計(jì)算。表4-2 影響

19、系數(shù) (砂漿強(qiáng)度等級(jí)M5)或00.0250.050.0750.10.1250.1534681010.980.950.910.870.990.950.910.860.820.970.900.860.810.760.940.850.810.760.710.890.800.750.700.650.840.740.690.640.600.790.690.640.590.5512141618200.820.770.720.670.620.770.720.670.620.570.710.660.610.570.530.660.610.560.520.480.600.560.520.480.440.550.

20、510.470.440.400.510.470.440.400.3722242628300.580.540.500.460.420.530.490.460.420.390.490.450.420.390.360.450.410.380.360.330.410.380.350.330.310.380.350.330.300.280.350.320.300.280.260.1750.20.2250.250.2750.33468100.730.640.590.540.500.680.580.540.500.460.620.530.490.460.420.570.490.450.420.390.520

21、.450.420.390.360.480.410.380.360.3312141618200.470.430.400.370.340.430.400.370.340.320.390.360.340.310.290.360.340.310.290.270.330.310.290.270.250.310.290.270.250.2322242628300.320.300.280.260.240.300.280.260.240.220.270.260.240.220.210.250.240.220.210.200.240.220.210.190.180.220.210.190.180.17表4-3

22、影響系數(shù) (砂漿強(qiáng)度等級(jí)M2.5) 00.0250.050.0750.10.1250.1534681010.970.930.890.830.990.940.890.840.780.970.890.840.780.720.940.840.780.720.670.890.780.730.670.610.840.730.670.620.560.790.670.620570.5212141618200.780.720.660.610.560.720.660.610.560.510.670.610.560.510.470.610.560.510.470.430.560.510.470.430.390.5

23、20.470.430.400.360.470.430.400.360.3322242628300.510.460.420.390.360.470.430.390.360.330.430390.360.330.300.390.360.330.300.280.360.330.310.280.260.330.310.280.260.240.310.280.260.240.22 0.1750.20.2250.250.2750.33468100.730.620.570.520.470.680.570.520.480.430.620520.480.440.400.570.480.440.400.370.5

24、20.440.400.370.340.480.400.370.340.3112141618200.430.400.360.330.310.400.360.340.310.280.370.340.310.290.260.340.310.290.260.240.310.290.260.240.230.290.270.250.230.2122242628300.280.260.240.220.210.260.240.220.210.200.240.230.210.200.180.230.210.200.180.170.210.200.180.170.160.200.180.170.160.15表4-

25、4 影響系數(shù)(砂漿強(qiáng)度0) 00.0250.050.0750.10.1250.1534681010.870.760.630.530.990.820.700.580.480.970.770.650.540.440.940.710.590.490.410.890.660.540.450.370.840.600.500.410.340.790.550.460.380.3212141618200.440.360.300.260.220.400.330.280.240.200.370.310.260.220.190.340.280.240.210.180.310.260.220.190.170.290.

26、240.210.180.160.270.230.190.170.1522242628300.190.160.140.120.110.180.150.130.120.100.160.140.130.110.100.150.130.120.110.090.140.130.110.100.090.140.120.110.100.090.130.110.100.090.08 0.1750.20.2250.250.2750.33468100.730.510.420.350.290.680.460.390.320.270.620.430.360.300.250.570.390.330.280.230.52

27、0.360.300.250.220.480.330.280.240.2012141618200.250.210.180.160.140.230.200.170.150.130.210.180.160.140.120.200.170.150.130.120.190.160.140.120.110.170.150.130.120.1022242628300.120.110.100.090.080.120.100.090.080.070.110.100.090.080.070.100.090.080.080.070.100.090.080.070.070.090.080.070.070.06表4-5

28、 燒結(jié)普通磚和燒結(jié)多孔磚砌體的抗壓強(qiáng)度設(shè)計(jì)值/Mpa毛料石強(qiáng)度等級(jí)砂漿強(qiáng)度等級(jí)砂漿強(qiáng)度M15M10M7.5M5M2.50MU303.943.272.932.592.261.15MU253.602.982.682.372.061.05MU203.222.672.392.121.840.94MU152.792.312.071.831.600.82MU101.891.691.501.300.67表4-6 混凝土普通磚和混凝土多孔磚砌體的抗壓強(qiáng)度設(shè)計(jì)值/Mpa磚強(qiáng)度等級(jí)砂漿強(qiáng)度等級(jí)砂漿強(qiáng)度Mb20Mb15Mb10Mb7.5Mb50MU304.613.943.272.932.591.15MU254.21

29、3.602.982.682.371.05MU203.773.222.672.392.120.94MU152.792.312.071.830.82表4-7 蒸壓灰砂普通磚和蒸壓粉煤灰普通磚砌體的抗壓強(qiáng)度設(shè)計(jì)值/Mpa磚強(qiáng)度等級(jí)砂漿強(qiáng)度等級(jí)砂漿強(qiáng)度M15M10M7.5M50MU253.602.982.682.371.05MU203.222.672.392.120.94MU152.792.312.071.830.82表4-8 單排孔混凝土砌塊和輕集料混凝土砌塊對(duì)孔砌筑砌體的抗壓強(qiáng)度設(shè)計(jì)值/Mpa砌塊強(qiáng)度等級(jí)砂漿強(qiáng)度等級(jí)砂漿強(qiáng)度Mb20Mb15Mb10Mb7.5Mb50MU206.305.684.95

30、4.443.942.33MU154.614.023.613.201.89MU102.792.502.221.31MU7.51.931.711.01MU51.190.70表4-9 雙排孔或多排孔輕集料混凝土砌塊砌體的抗壓強(qiáng)度設(shè)計(jì)值/Mpa砌塊強(qiáng)度等級(jí)砂漿強(qiáng)度等級(jí)砂漿強(qiáng)度Mb10Mb7.5Mb50MU103.082.762.451.44MU7.52.131.881.12MU51.310.78MU3.50.950.56表4-10 毛料石砌體的抗壓強(qiáng)度設(shè)計(jì)值/Mpa毛料石強(qiáng)度等級(jí)砂漿強(qiáng)度等級(jí)砂漿強(qiáng)度M7.5M5M2.50MU1005.424.804.182.13MU804.854.293.731.91

31、MU604.203.713.231.65MU503.833.392.951.51MU403.433.042.641.35MU302.972.632.291.17MU202.422.151.870.95 表4-11 毛石砌體的抗壓強(qiáng)度設(shè)計(jì)值/Mpa毛料石強(qiáng)度等級(jí)砂漿強(qiáng)度等級(jí)砂漿強(qiáng)度M7.5M5M2.50MU1001.271.120.980.34MU801.131.000.870.30MU600.980.870.760.26MU500.900.800.690.23MU400.800.710.620.21MU300.690.610.530.18MU200.560.510.440.15查表4-2 表4

32、-4確定值時(shí),構(gòu)件高厚比應(yīng)按下式確定:對(duì)矩形截面 (4-12)對(duì)T形截面 (4-13)式中:受壓構(gòu)件的計(jì)算高度,查表3-1確定。 矩形截面軸向力偏心方向邊長(zhǎng),當(dāng)軸心受壓時(shí)為截面最小邊長(zhǎng)。 T形截面折算高度。不同砌體材料的高厚比修正系數(shù),查表4-12確定。為了確保結(jié)構(gòu)工程質(zhì)量,在按式(4-11)進(jìn)行承載力計(jì)算式軸向力的偏心距應(yīng)符合下列限值要求,即 (4-14)式中:截面重心到軸向力所在偏心方向截面邊緣的距離,如圖4-8所示。圖4-8 截面的取值表4-12 高厚比修正系數(shù)砌體材料類別燒結(jié)普通磚、燒結(jié)多孔磚1.0混凝土普通磚、混凝土多孔磚、混凝土及輕集料混凝土砌塊1.1蒸壓灰砂普通磚、蒸壓粉煤灰普通

33、磚、細(xì)料石1.2粗料石、毛石1.5注:對(duì)灌孔混凝土砌塊砌體,=1.0。4.4梁端支承處砌體的局部受壓承載力驗(yàn)算當(dāng)屋(樓)面梁擱置在墻體上時(shí),梁端支承處砌體處于局部受壓狀態(tài),此時(shí)應(yīng)對(duì)梁端支承處砌體按下列公式進(jìn)行局部受壓承載力驗(yàn)算: (4-15) (4-16) (4-17) (4-18) (4-19) (4-20)式中:上部荷載的折減系數(shù),當(dāng)時(shí),應(yīng)??;局部受壓面積內(nèi)上部軸向力設(shè)計(jì)值,N;梁端荷載設(shè)計(jì)值產(chǎn)生的支承壓力,N;上部平均壓應(yīng)力設(shè)計(jì)值;局部受壓面積;梁端有效支承長(zhǎng)度,mm,當(dāng)(實(shí)際支承長(zhǎng)度)時(shí),應(yīng)??;梁的截面高度,mm;砌體抗壓強(qiáng)度設(shè)計(jì)值,Mpa; 梁端底面應(yīng)力圖形的完整系數(shù),應(yīng)取0.7;砌

34、體局部抗壓強(qiáng)度提高系數(shù),按(4-20)計(jì)算;A0影響砌體局部抗壓強(qiáng)度的計(jì)算面積,按圖4-9確定。圖4-9 影響局部抗壓強(qiáng)度的面積A0按式(4-20)計(jì)算的值,尚應(yīng)符合下列規(guī)定,以免產(chǎn)生劈裂破壞:(1)在圖4-9a情況下,2.5;(2)在圖4-9b情況下,2.0;(3)在圖4-9c情況下,1.5;(4)在圖4-9d情況下,1.25;對(duì)多孔磚砌體和按構(gòu)造要求灌孔的砌塊砌體,在圖4-9a、b情況下,尚應(yīng)符合1.5。對(duì)于未灌孔混凝土砌塊砌體,=1.0。4.5 梁端下設(shè)有墊塊或墊梁時(shí)支撐處砌體局部受壓承載力驗(yàn)算梁端支撐處砌體局部受壓承載力不滿足式(4-15)的要求時(shí),設(shè)置剛性墊塊或墊梁是彌補(bǔ)砌體局部受壓

35、承載力不足的有效措施,此時(shí)應(yīng)驗(yàn)算墊塊或墊梁下砌體的局部受壓承載力。4.5 1設(shè)置剛性墊塊設(shè)置預(yù)制或現(xiàn)澆剛性墊塊后(圖4-10)墊塊下砌體的局部受壓承載力應(yīng)按下式計(jì)算: (4-21) (4-22) (4-23)式中:N0墊塊面積Ab內(nèi)上部軸力設(shè)計(jì)值,;墊塊上N0和合力的影響線數(shù),應(yīng)采用表4-2表4-4中當(dāng)3時(shí)的值;1墊塊以外砌體面積的有利影響系數(shù),應(yīng)取 ,但不小于1.0;砌體局部抗壓強(qiáng)度提高系數(shù),按式(2-25)以Ab代替Al計(jì)算得出;墊塊面積;墊塊伸入墻內(nèi)的長(zhǎng)度;墊塊的寬度。圖4-10 梁端下的剛性墊塊剛性墊塊應(yīng)符合下列構(gòu)造規(guī)定:(1) 剛性墊塊的高度不宜小于180mm,自梁邊算起的墊塊挑出長(zhǎng)

36、度不宜大于墊塊高度 。(2) 在帶壁柱墻的壁柱內(nèi)設(shè)剛性墊塊時(shí),其計(jì)算面積應(yīng)取壁柱范圍內(nèi)的面積,而不應(yīng)計(jì)算翼緣部分,同時(shí)壁柱上墊塊伸入翼墻內(nèi)的長(zhǎng)度不應(yīng)小于120mm。(3) 當(dāng)現(xiàn)澆墊塊與梁端整體澆筑時(shí),墊塊可在梁高范圍內(nèi)設(shè)置。為了計(jì)算,必須先確定的作用點(diǎn)。離墻內(nèi)邊緣的距離為0.4(圖4-10),其中為剛性墊塊上表面處梁端的有效支承長(zhǎng)度,按下式確定 (4-24)式中:剛性墊塊的影響系數(shù),可按表4-13采用。表4-13 系數(shù)值表00.20.40.60.85.45.76.06.97.8注:表中其間的數(shù)值可采用插入法求得。4.5.2 設(shè)置墊梁當(dāng)梁或屋架端部支承處的砌體墻上設(shè)有連續(xù)的鋼筋混凝土梁(如圈梁)

37、時(shí),此時(shí)支承梁還起墊梁的作用。墊梁下砌體的局部受壓承載力應(yīng)按下式計(jì)算: (4-25) (4-26) (4-27)式中:墊梁上部軸向力設(shè)計(jì)值; 墊梁在墻厚方向的寬度,mm; 墊梁底面壓應(yīng)力分布系數(shù),當(dāng)荷載沿墻厚方向均勻分布時(shí),;不均勻時(shí),; 上部平均壓力設(shè)計(jì)值; 墊梁折算高度; 分別為墊梁的混凝土彈性模量和截面慣性矩; 砌體的彈性模量; 墻厚(mm)。5 墻、柱的一般構(gòu)造要求5.1 砌體材料的最低強(qiáng)度等級(jí)為了增大砌體結(jié)構(gòu)的可靠性,選用砌體材料時(shí),應(yīng)保證它們有足夠的強(qiáng)度和良好的耐久性。砌體結(jié)構(gòu)所用材料的最低強(qiáng)度等級(jí)應(yīng)符合下列要求。(1)五層及五層以上房屋的墻,以及受振動(dòng)或?qū)痈叽笥?m的墻、柱所用材

38、料的最低強(qiáng)度等級(jí):磚采用MU10。砌塊采用MU7.5。石材采用MU30。砂漿采用M5。對(duì)安全等級(jí)為一級(jí)或設(shè)計(jì)使用年限大于50年的房屋,墻、柱所用材料的最低強(qiáng)度等級(jí)應(yīng)比上述規(guī)定至少提高一級(jí)。(2)地面以下或防潮層以下的砌體、潮濕房間的墻,所用材料的最低強(qiáng)度等級(jí)應(yīng)符合表5-1的要求。表5-1 地面以下或防潮層以下的砌體、潮濕房間墻所用材料的最低強(qiáng)度等級(jí)潮濕程度燒結(jié)普通磚混凝土普通磚、蒸壓灰砂磚混凝土砌塊石 材水泥砂漿稍潮濕的很潮濕的含水飽和的MU15MU20MU20MU20MU20MU25MU7.5MU10MU15MU30MU30MU40M5M7.5M10注:1.在凍脹地區(qū),地面以下或防潮層以下的

39、砌體,不宜采用多孔磚,如采用時(shí),其孔洞應(yīng)用不低于M10的水泥砂漿預(yù)先灌實(shí)。當(dāng)采用混凝土空心砌塊時(shí),其孔洞應(yīng)采用強(qiáng)度等級(jí)不低于Cb20的混凝土預(yù)先灌實(shí);2.對(duì)安全等級(jí)為一級(jí)或設(shè)計(jì)年限大于50a的房屋,表中材料強(qiáng)度等級(jí)應(yīng)至少提高一級(jí)。5.2 墻、柱局部構(gòu)造5.2.1 墻、柱截面尺寸承重的獨(dú)立磚柱截面尺寸不應(yīng)小于240mm×370mm。毛石墻的厚度不宜小于350mm,毛料石柱較小邊長(zhǎng)不宜小于400mm。當(dāng)有振動(dòng)荷載時(shí),墻、柱不宜采用毛石砌體。 5.2.2 墊塊設(shè)置 跨度大于6m的屋架和跨度大于下列數(shù)值的梁,應(yīng)在支承處砌體上設(shè)置混凝土或鋼筋混凝土墊塊;當(dāng)墻中設(shè)有圈梁時(shí),墊塊與圈梁宜澆成整體。

40、 (1)對(duì)磚砌體為4.8m;(2)對(duì)砌塊和料石砌體為4.2m;(3)對(duì)毛石砌體為3.9m。5.2.3 壁柱設(shè)置當(dāng)梁跨度大于或等于下列數(shù)值時(shí),其支承處宜加設(shè)壁柱或其他加強(qiáng)措施:(1) 對(duì)240mm厚的磚墻為6m;對(duì)180mm厚的磚墻為4.8m;(2) 對(duì)砌塊、料石墻為4.8m。5.2.4 板與墻體的連接預(yù)制鋼筋混凝土板的支撐長(zhǎng)度,在墻上不宜小于100mm;在鋼筋混凝土圈梁上不宜小于80mm,當(dāng)利用板端伸出鋼筋拉結(jié)和混凝土灌封時(shí),其支撐長(zhǎng)度可為40mm,但板端縫寬不小于80mm,灌封混凝土不宜低于C20。5.3混凝土砌塊墻體的構(gòu)造要求為了增強(qiáng)混凝土砌塊房屋的整體剛度、提高其抗裂能力,混凝土砌塊墻體

41、應(yīng)符合下列要求:(1) 砌塊砌體應(yīng)分皮錯(cuò)縫搭砌,上下皮搭砌長(zhǎng)度不得小于90mm。當(dāng)搭砌長(zhǎng)度不滿足上述要求時(shí),應(yīng)在水平灰縫內(nèi)設(shè)置不少于24的焊接鋼筋網(wǎng)片(橫向鋼筋的間距不宜大于200mm),網(wǎng)片每端均應(yīng)超過(guò)該垂直縫,其長(zhǎng)度不得小于300mm。(2) 砌塊墻與后砌隔墻交接處,應(yīng)沿墻高每400mm在水平灰縫內(nèi)設(shè)置不少于24、橫筋間距不大于200mm的焊接鋼筋網(wǎng)片。(3) 混凝土砌塊房屋,宜將縱橫墻交接處、距墻中心線每邊不小于300mm范圍內(nèi)的孔洞。采用不低于Cb20的灌孔混凝土灌實(shí),灌實(shí)高度應(yīng)為墻身全高。(4) 混凝土砌塊墻體的下列部位,如未設(shè)圈梁或混凝土墊塊,應(yīng)采用不低于Cb20的灌孔混凝土將孔洞

42、灌實(shí):格柵、檁條和鋼筋混凝土樓板的支撐面下,高度不應(yīng)小于200mm的砌體。屋架、梁等構(gòu)件的支承面下,高度不應(yīng)小于600mm,長(zhǎng)度不應(yīng)小于600mm的砌體。挑梁支承面下,距墻中心線每邊不應(yīng)小于300mm,高度不應(yīng)小于600mm的砌體。5.4 砌體中留槽洞及埋設(shè)管道時(shí)的構(gòu)造要求在砌體中預(yù)留糟及埋設(shè)管道對(duì)砌體的承載力影響較大,尤其是對(duì)截面尺寸較小的承重墻體、獨(dú)立柱更加不利。因此,不應(yīng)在截面長(zhǎng)邊小于500mm的承重墻體、獨(dú)立柱內(nèi)埋設(shè)管線;不宜在墻體中穿行暗線或預(yù)留、開(kāi)鑿溝槽,無(wú)法避免時(shí)應(yīng)采取必要措施或按削弱后的截面驗(yàn)算墻體的承載力。然而,對(duì)受力較小或未灌孔的砌塊砌體,允許在墻體的豎向空洞中設(shè)置管線。6

43、 墻下條形基礎(chǔ)設(shè)計(jì)六層及六層以下混合結(jié)構(gòu)房屋墻下基礎(chǔ)常采用無(wú)筋擴(kuò)展基礎(chǔ),亦即習(xí)慣上所稱的剛性條形基礎(chǔ)。其設(shè)計(jì)內(nèi)容包括:選擇基礎(chǔ)的類型;確定基礎(chǔ)埋置深度;按承載力要求計(jì)算基礎(chǔ)底面面積和基礎(chǔ)高度;最后繪出基礎(chǔ)施工圖。6.1 剛性基礎(chǔ)類型根據(jù)所用材料的不同,剛性基礎(chǔ)有磚基礎(chǔ)、毛石基礎(chǔ)、混凝土基礎(chǔ)以及毛石混凝土基礎(chǔ)。其中,磚基礎(chǔ)在工程中應(yīng)用最廣泛;毛石基礎(chǔ)在產(chǎn)石地區(qū)應(yīng)用較多;混凝土基礎(chǔ)適用于地下水位較高的情況,當(dāng)混凝土基礎(chǔ)體積較大時(shí)多采用毛石基礎(chǔ)。6.2 基礎(chǔ)的埋置深度影響基礎(chǔ)埋置深度的因素較多,設(shè)計(jì)時(shí)應(yīng)根據(jù)工程地質(zhì)條件和建筑地基設(shè)計(jì)規(guī)范(GB 50072002)的要求確定適用的埋置深度。在滿足地基穩(wěn)

44、定和變形要求的前提下,基礎(chǔ)應(yīng)盡量淺埋。除巖石地基外,基礎(chǔ)埋置的最小深度不易小于0.5m,基礎(chǔ)頂面距室外設(shè)計(jì)地面至少0.150.2m。對(duì)于凍脹性地基,基礎(chǔ)底面應(yīng)處于凍脹線以下0.10.2m。此外,新建建筑與原有建筑相鄰時(shí),新建建筑的基礎(chǔ)埋深不宜大于原有建筑物的基礎(chǔ)埋深,否則兩基礎(chǔ)間應(yīng)保持一定凈距,凈距一般取相鄰地基面高差的12倍。6.3 墻下條形基礎(chǔ)的計(jì)算墻下條形基礎(chǔ)的計(jì)算包括確定基礎(chǔ)底面面積和基礎(chǔ)的高度。對(duì)于五層及五層以下的混合結(jié)構(gòu)房屋,可根據(jù)地基承載力的要求直接確定墻下條形基礎(chǔ)的地面面積(或底面尺寸),一般不必驗(yàn)算地基的變形;基礎(chǔ)高度則由下式確定: (6-1)式中:-基礎(chǔ)高度。-基礎(chǔ)底面寬度。-基礎(chǔ)頂面的砌體寬度。-基礎(chǔ)臺(tái)階寬高比的允許值,查表6-1確定?;A(chǔ)材料質(zhì)量要求臺(tái)階高寬比的允許值100100<200200<300混凝土基礎(chǔ)C15混凝土1:1.001:1.001:1.25毛石混凝土基礎(chǔ)C15混凝土1:1.

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論