版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
1、1總 則12術(shù)語(yǔ)、符號(hào)22.1術(shù)語(yǔ)22.2符號(hào)33基本規(guī)定44材料75結(jié)構(gòu)分析及極限狀態(tài)計(jì)算96構(gòu)造規(guī)定116混凝土保護(hù)層116.2鋼筋的錨固126.3鋼筋的連接136.4縱向受力鋼筋的最小配筋率147抗震設(shè)計(jì)168施工及質(zhì)量驗(yàn)收238.1施工播施238.2質(zhì)雖驗(yàn)收25附錄A帶肋鋼筋的標(biāo)志27附錄B 600MPa鋼筋的公稱直徑及公稱截面面積28本規(guī)程用詞說(shuō)明29引用標(biāo)準(zhǔn)名錄30附:條文說(shuō)明31Contents1 General Provision12Tcrms and Symbols22.1 Terms22.2 Symbols33 General Requirements44 Material
2、s75 Structural Analysis and Limit StatesDesign96 Detailing Requirements116.1 ConcreteCover116.2 Anchorage of Steel Reinforcement126.3 Splices of Reinforcement136.4 Minimum Ratio of Reinforcement for Flexual and AxialLoading Members147 Seismic Design168 Construction and Quality Acceptance238.1 Constn
3、iction Measures238.2 Quality Acceptance25Appendix A Ribbed Steel Bar Sign27Appendix B Nominal Diameter and Section Area of 600MPaSteel Bars28Explanation of Wording inThis Code29List of Quoted Standards30Addition: Explanation of Provisions311總 貝I1.0.1為貫徹執(zhí)行國(guó)家肖能環(huán)保技術(shù)經(jīng)濟(jì)政策,在混凝上結(jié)構(gòu)中推 廣應(yīng)用熱軋帶肋髙強(qiáng)鋼筋,做到技術(shù)先進(jìn)、安全可靠
4、、經(jīng)濟(jì)合理、 確保質(zhì)量,制定本標(biāo)準(zhǔn)。1.0.2本標(biāo)準(zhǔn)適用于配宜600MPa鋼筋的混凝土結(jié)構(gòu)的房屋和一般 構(gòu)筑物的設(shè)計(jì)、施工和質(zhì)量驗(yàn)收。1.0.3采用熱軋帶肋髙強(qiáng)鋼筋的混凝土結(jié)構(gòu)設(shè)il與施工除應(yīng)符合 本標(biāo)準(zhǔn)的要求外,尚應(yīng)符合國(guó)家現(xiàn)行有關(guān)標(biāo)準(zhǔn)的規(guī)左。2術(shù)語(yǔ)、符號(hào)2術(shù)語(yǔ)2.1.1 熱軋帶肋鋼筋牌號(hào) brand of hot rolled ribbed bars用以標(biāo)志熱軋帶肋鋼筋品牌的符號(hào),由鋼筋品種的英文字母 的字頭及其屈服強(qiáng)度標(biāo)準(zhǔn)值(特征值)組成。2.1.2 600MPa 熱軋帶肋鋼筋 600MPa level hot rolled ribbed high-strength bars強(qiáng)度級(jí)別為6
5、00MPa的普通熱軋帶肋鋼筋。2.1.3 鋼筋混凝上結(jié)構(gòu) reinforced concrete stmcture配置受力的普通鋼筋、鋼筋網(wǎng)或鋼筋竹架的混凝上結(jié)構(gòu)。2.1.4 錨固長(zhǎng)度 anchorage length受力鋼筋端部依靠英表而與混凝上的粘結(jié)作用或端部彎鉤、 錨頭對(duì)混凝上的擠壓作用而達(dá)到設(shè)計(jì)所需應(yīng)力的長(zhǎng)度。2.1.5混凝上保護(hù)層concrete cover結(jié)構(gòu)構(gòu)件中鋼筋外邊緣至構(gòu)件表面范圍用于保護(hù)鋼筋的混凝 土,簡(jiǎn)稱保護(hù)層。2.1.6 鋼筋連接 splice of reinforcement通過(guò)綁扎搭接、機(jī)械連接、焊接等方法實(shí)現(xiàn)鋼筋之間內(nèi)力傳 遞的構(gòu)造形式。2.1.7 配筋率 ra
6、tio of reinforcement混凝上構(gòu)件中配置的鋼筋而積(或體積)與規(guī)左的混凝上截而面 積(或體積)的比值。2.2符號(hào)HRB600強(qiáng)度級(jí)別為600MPa的熱軋帶肋鋼筋:HRB600E強(qiáng)度級(jí)別為600MPa且有較高抗震性能的熱軋 帶肋鋼筋:鋼筋的彈性模量;混凝上軸心抗壓強(qiáng)度設(shè)計(jì)值;混凝上軸心抗拉強(qiáng)度設(shè)訃值;鋼筋屈服強(qiáng)度標(biāo)準(zhǔn)值:鋼筋極限強(qiáng)度標(biāo)準(zhǔn)值:一鋼筋的抗拉強(qiáng)度設(shè)計(jì)值;鋼筋的抗拉、抗壓強(qiáng)度設(shè)計(jì)值:橫向鋼筋的抗拉強(qiáng)度設(shè)計(jì)值;鋼筋在最大力下的總伸長(zhǎng)率,也稱均勻伸長(zhǎng)率。按荷載準(zhǔn)永久組合或標(biāo)準(zhǔn)組合,并考慮長(zhǎng)期作用影響的計(jì) 算最大裂縫寬度:混凝土保護(hù)層厚度:鋼筋的公稱直徑:受拉鋼筋的基本錨固長(zhǎng)度
7、:一受拉鋼筋的錨固長(zhǎng)度:G縱向受拉鋼筋的抗震錨固長(zhǎng)度:縱向受力鋼筋的最小配筋率;間接鋼筋或箍筋的體枳配筋率;最小配箍特征值。錨固鋼筋的外形系數(shù):錨固長(zhǎng)度修正系數(shù)。33基本規(guī)定3.0.1鋼筋混凝上結(jié)構(gòu)構(gòu)件中的縱向受力鋼筋宜采用600MPa熱軋 帶肋鋼筋,抗剪、抗扭、抗沖切構(gòu)件也可采用600MPa熱軋帶肋 鋼筋。3.0.2對(duì)持久設(shè)計(jì)狀況、短暫設(shè)訃狀況和地震設(shè)計(jì)狀況,當(dāng)用內(nèi)力 的形式表達(dá)時(shí),結(jié)構(gòu)構(gòu)件應(yīng)采用下列承載能力極限狀態(tài)設(shè)訃表達(dá) 式:yoSR(3.0.2-1)R = R(&,fs,"k,)/pad (3.0.2-2) 式中:理一結(jié)構(gòu)重要性系數(shù):在持久設(shè)計(jì)狀況和短暫設(shè)汁狀況下,對(duì)
8、安全等級(jí)為一級(jí)的結(jié)構(gòu)構(gòu)件不應(yīng)小于1.1,對(duì)安全等 級(jí)為二級(jí)的結(jié)構(gòu)構(gòu)件不應(yīng)小于1.0,對(duì)安全等級(jí)為三級(jí) 的結(jié)構(gòu)構(gòu)件不應(yīng)小于0.9:對(duì)地震設(shè)計(jì)狀況下應(yīng)取1.0:S承載能力極限狀態(tài)下作用組合的效應(yīng)設(shè)計(jì)值:對(duì)持久設(shè) 計(jì)狀況和短暫設(shè)計(jì)狀況應(yīng)按作用的基本組合計(jì)算;對(duì) 地震設(shè)計(jì)狀況應(yīng)按作用的地震組合計(jì)算;R-結(jié)構(gòu)構(gòu)件的抗力設(shè)計(jì)值;R()結(jié)構(gòu)構(gòu)件的抗力函數(shù):加一結(jié)構(gòu)構(gòu)件的抗力模型不泄性系數(shù):靜力設(shè)計(jì)取1.0,對(duì) 不確立性較大的結(jié)構(gòu)構(gòu)件根據(jù)具體情況取大于1.0的 數(shù)值:抗震設(shè)汁應(yīng)采用承載力抗箴調(diào)整系數(shù)血代替加:&、混凝上、鋼筋的強(qiáng)度設(shè)計(jì)值,應(yīng)分別根據(jù)混凝上 結(jié)構(gòu)設(shè)計(jì)規(guī)范GB 50010第4.1.4條及第
9、4.2.3條的規(guī)定和本 標(biāo)準(zhǔn)的規(guī)定取值;心一幾何參數(shù)的標(biāo)準(zhǔn)值,當(dāng)幾何參數(shù)的變異性對(duì)結(jié)構(gòu)性能 有明顯的不利影響時(shí),應(yīng)增減一個(gè)附加值。3.0.3對(duì)于正常使用極限狀態(tài),鋼筋混凝上構(gòu)件、預(yù)應(yīng)力混凝上構(gòu) 件應(yīng)分別按荷載的準(zhǔn)永久組合并考慮長(zhǎng)期作用的影響或標(biāo)準(zhǔn)組合 并考慮長(zhǎng)期作用的影響,采用下列極限狀態(tài)設(shè)計(jì)表達(dá)式進(jìn)行驗(yàn)算:SWC (3.0.3)式中:S正常使用極限狀態(tài)荷載組合的效應(yīng)設(shè)計(jì)值;C結(jié)構(gòu)構(gòu)件達(dá)到正常使用要求所規(guī)泄的變形、應(yīng)力、裂 縫寬度和自振頻率等的限值。3.0.4鋼筋混凝土受彎構(gòu)件的最大撓度應(yīng)按荷載的準(zhǔn)永久組合, 預(yù)應(yīng)力混凝土受彎構(gòu)件的最大撓度應(yīng)按荷載的標(biāo)準(zhǔn)組合,并均應(yīng) 考慮荷載長(zhǎng)期作用的影響進(jìn)行
10、訃算,其汁算值不應(yīng)超過(guò)混凝上 結(jié)構(gòu)設(shè)計(jì)規(guī)范GB 50010第3.4.3條規(guī)泄的撓度限值。3.0.5結(jié)構(gòu)構(gòu)件正截面的受力裂縫控制等級(jí)分為三級(jí),等級(jí)劃分及 要求應(yīng)符合下列規(guī)左:一級(jí)嚴(yán)格要求不出現(xiàn)裂縫的構(gòu)件,按荷載標(biāo)準(zhǔn)組合計(jì)算 時(shí),構(gòu)件受拉邊緣混凝土不應(yīng)產(chǎn)生拉應(yīng)力。二級(jí)一般要求不出現(xiàn)裂縫的構(gòu)件,按荷載標(biāo)準(zhǔn)組合計(jì)算 時(shí),構(gòu)件受拉邊緣混凝土拉應(yīng)力不應(yīng)大于混凝上軸心抗拉強(qiáng)度標(biāo) 準(zhǔn)值。三級(jí)允許出現(xiàn)裂縫的構(gòu)件。對(duì)鋼筋混凝上構(gòu)件,按荷載 準(zhǔn)永久組合并考慮長(zhǎng)期作用影響訃算時(shí),構(gòu)件的最大裂縫寬度不 應(yīng)超過(guò)混凝上結(jié)構(gòu)設(shè)計(jì)規(guī)范GB 50010規(guī)定的最大裂縫寬度限 值。對(duì)預(yù)應(yīng)力混凝土構(gòu)件,按荷載效應(yīng)的標(biāo)準(zhǔn)組合并考慮長(zhǎng)期作
11、 用影響計(jì)算時(shí),構(gòu)件的最大裂縫寬度不應(yīng)超過(guò)混凝上結(jié)構(gòu)設(shè)計(jì) 規(guī)范GB 50010規(guī)左的最大裂縫寬度限值;對(duì)二a類(lèi)環(huán)境的預(yù)應(yīng) 力混凝上構(gòu)件,尚應(yīng)按荷載準(zhǔn)永久組合計(jì)算,且構(gòu)件受拉邊緣混 凝上的拉應(yīng)力不應(yīng)大于混凝上的抗拉強(qiáng)度標(biāo)準(zhǔn)值。3.0.6結(jié)構(gòu)構(gòu)件應(yīng)根據(jù)結(jié)構(gòu)類(lèi)型和混凝上結(jié)構(gòu)設(shè)訃規(guī)范GB50010第3.5.2條規(guī)泄的環(huán)境類(lèi)別,按混凝上結(jié)構(gòu)設(shè)計(jì)規(guī)范GB 50010第3.4.5條的規(guī)左選用不同的裂縫控制等級(jí)及最大裂縫寬度 限值。94材料4.0.1 600MPa熱軋帶肋鋼筋技術(shù)要求應(yīng)符合本標(biāo)準(zhǔn)附錄A的規(guī)左。4.0.2鋼筋的標(biāo)準(zhǔn)強(qiáng)度應(yīng)具有不小于95%的保證率。鋼筋的屈服強(qiáng)度標(biāo)準(zhǔn)值、極限強(qiáng)度標(biāo)準(zhǔn)值,應(yīng)按表4.0
12、.2的規(guī) 定取用。表4.0.2高強(qiáng)鋼筋強(qiáng)度標(biāo)準(zhǔn)值鋼筋牌號(hào)符號(hào)公稱宜徑 d (mm)fyk(N/mm2).Aik(N/mm2)HRB600. HRB600E亞6-506007304.03鋼筋的抗拉強(qiáng)度強(qiáng)ZB上建設(shè)訃室度設(shè)訃值斤、抗壓強(qiáng)度設(shè) 計(jì)值fy應(yīng)按表4.0.3的規(guī)定采v加Shejiyuan8用。表4.0.3 HRB600鋼筋的強(qiáng)度設(shè)計(jì)值(N/nun2)鋼筋牌號(hào)抗拉強(qiáng)度設(shè)計(jì)值A(chǔ)抗斥強(qiáng)度設(shè)計(jì)值/'yHRB600. HRB600E510490對(duì)軸心受壓構(gòu)件,當(dāng)采用HRB600、HRB600E鋼筋時(shí),鋼筋 的抗壓強(qiáng)度設(shè)計(jì)值心應(yīng)取為400N/mm2o橫向鋼筋的抗拉強(qiáng)度設(shè) 計(jì)值.&應(yīng)按表
13、中辦的數(shù)值采用:但用作受剪、受扭、受沖切承載 力計(jì)算時(shí),其數(shù)值大于360N/mm2時(shí)應(yīng)取為360N/mm2o4.0.4鋼筋在最大力下的總伸長(zhǎng)率兔不應(yīng)小于表4.0.4規(guī)左的數(shù)值。表4.0.4高強(qiáng)鋼筋最大力下總伸長(zhǎng)率限值鋼筋牌號(hào)敬人力卜總伸長(zhǎng)率限HRB6007.5HRB600E9.04.0.5熱軋帶肋髙強(qiáng)鋼筋彈性模量5取2.00X 105N/mm2,必要時(shí) 可采用實(shí)測(cè)的彈性模量。4.0.6應(yīng)用熱軋帶肋髙強(qiáng)鋼筋的混凝上結(jié)構(gòu),應(yīng)采用C30及以上強(qiáng) 度等級(jí)的混凝土。4.0.7當(dāng)進(jìn)行鋼筋代換時(shí),除應(yīng)符合設(shè)計(jì)要求的構(gòu)件承載力、最大 力下的總伸長(zhǎng)率、裂縫寬度驗(yàn)算及抗震規(guī)泄外,尚應(yīng)滿足最小配 筋率、鋼筋間距、保
14、護(hù)層厚度、鋼筋錨固長(zhǎng)度、接頭面積百分率 及搭接長(zhǎng)度等構(gòu)造要求。5結(jié)構(gòu)分析及極限狀態(tài)計(jì)算5.0.1配置600MPa鋼筋的混凝上結(jié)構(gòu)作用效應(yīng)分析應(yīng)符合混凝 上結(jié)構(gòu)設(shè)計(jì)規(guī)范GB50010的規(guī)左。5.0.2采用塑性內(nèi)力重分布分析方法進(jìn)行承載能力極限狀態(tài)計(jì)算 時(shí),應(yīng)符合下列要求:I配置600MPa鋼筋的混凝上連續(xù)梁和連續(xù)單向板,可采用 塑性內(nèi)力重分布方法進(jìn)行分析。重力荷載作用下的框架、框架-剪力墻結(jié)構(gòu)中的現(xiàn)澆梁以及雙 向板等,經(jīng)彈性分析求得內(nèi)力后,可對(duì)支座或節(jié)點(diǎn)彎矩進(jìn)行適當(dāng) 調(diào)幅,并確左相應(yīng)的跨中彎矩。2按考慮塑性內(nèi)力重分布分析方法設(shè)計(jì)的結(jié)構(gòu)和構(gòu)件,應(yīng)選 用符合本標(biāo)準(zhǔn)第4.0.4條規(guī)眾的鋼筋,并應(yīng)滿足正
15、常使用極限狀態(tài) 要求且采取有效的構(gòu)造措施。對(duì)于直接承受動(dòng)力荷載的構(gòu)件,以及要求不出現(xiàn)裂縫或處于 三a、三b類(lèi)環(huán)境情況下的結(jié)構(gòu),不應(yīng)采用考慮塑性內(nèi)力重分布 的分析方法。3鋼筋混凝丄梁支座或肖點(diǎn)邊緣截面的負(fù)彎矩調(diào)幅幅度不 宜大于25%;彎矩調(diào)整后的梁端截面相對(duì)受壓區(qū)髙度不應(yīng)超過(guò) 0.35,且不宜小于O.lOo鋼筋混凝土板負(fù)彎矩調(diào)幅幅度不宜大于20%o5.0.3配置600MPa鋼筋的混凝上和預(yù)應(yīng)力混凝上結(jié)構(gòu)構(gòu)件,英靜 力的承載能力極限狀態(tài)訃算和抗役設(shè)防要求的承載力訃算,應(yīng)符 合混凝上結(jié)構(gòu)設(shè)汁規(guī)范GB 50010的相關(guān)規(guī)定。5.0.4在矩形、T形、倒T形和I形截面的鋼筋混凝上受拉、受彎 和偏心受壓構(gòu)件
16、及預(yù)應(yīng)力混凝上軸心受拉和受彎構(gòu)件中,按荷載 標(biāo)準(zhǔn)組合或準(zhǔn)永久組合并考慮長(zhǎng)期作用影響的最大裂縫寬度可按 混凝土結(jié)構(gòu)設(shè)計(jì)規(guī)范GB 50010的相關(guān)規(guī)左進(jìn)行計(jì)算。5.0.5配苣600MPa鋼筋的混凝土受彎構(gòu)件的撓度驗(yàn)算,應(yīng)符合混 凝上結(jié)構(gòu)設(shè)計(jì)規(guī)范GB 50010的相關(guān)規(guī)定。6構(gòu)造規(guī)定6混凝土保護(hù)層6丄1構(gòu)件中鋼筋的混凝上保護(hù)層厚度應(yīng)滿足下列要求。1構(gòu)件中受力鋼筋的保護(hù)層厚度不應(yīng)小于鋼筋的公稱直徑:2設(shè)汁使用年限為50年的混凝丄結(jié)構(gòu),最外層鋼筋的保護(hù)層 厚度應(yīng)符合表6.1.1的規(guī)泄;設(shè)計(jì)使用年限為100年的混凝上結(jié)構(gòu), 最外層鋼筋的保護(hù)層厚度不應(yīng)小于表6丄1中數(shù)值的1.4倍。表6丄1混凝土保護(hù)層最小厚
17、度c (mm)環(huán)境類(lèi)別板、墻、TC梁、柱桿一1520 一 a2025二 b2535:a3040三b4050注:混凝土強(qiáng)度等級(jí)不大于C25時(shí)茨中保護(hù)層厚度數(shù)值應(yīng)增in 5mm:2鋼筋混狀上基礎(chǔ)宜設(shè)賈混凝上墊層基礎(chǔ)中鋼筋的混黴上保護(hù)層皿度應(yīng)從鑽層頂面覽 起且不應(yīng)小P 40mmo6.1.2當(dāng)有充分依據(jù)并采取下列措施時(shí),可適當(dāng)減小混凝上保護(hù)層 的厚度。1構(gòu)件表面有可靠的防護(hù)層:2采用工廠化生產(chǎn)的預(yù)制構(gòu)件;3在混凝上中摻加阻銹劑或采用陰極保護(hù)處理等防銹措施;II4當(dāng)對(duì)地下室墻體釆取可靠的建筑防水做法或防護(hù)措施時(shí)與 上層接觸一側(cè)鋼筋的保護(hù)層厚度可適當(dāng)減少,但不應(yīng)小于25mm。6.2鋼筋的錨固6.2.1當(dāng)計(jì)
18、算中充分利用鋼筋的抗拉強(qiáng)度時(shí),受拉鋼筋的錨固應(yīng)符 合下列要求:1基本錨固長(zhǎng)度應(yīng)按下列公式計(jì)算:普通鋼筋/h J(6.2.1-l)f.式中:匚一受拉鋼筋的基本錨固長(zhǎng)度:厶一鋼筋的抗拉強(qiáng)度設(shè)計(jì)值;久一混凝上軸心抗拉強(qiáng)度設(shè)計(jì)值,按混凝土結(jié)構(gòu)設(shè)計(jì) 規(guī)范GB 50010的有關(guān)規(guī)定采用:當(dāng)混凝上強(qiáng)度等級(jí)高于C60 時(shí),按C60取值:一鋼筋的公稱直徑:a錨固鋼筋的外形系數(shù),取0.14。2受拉鋼筋的錨固長(zhǎng)度應(yīng)根據(jù)錨固條件按下列公式計(jì)算,且 不應(yīng)小于200mm:厶=4(621-2) 式中:/。一受拉鋼筋的錨固長(zhǎng)度。為一錨固長(zhǎng)度修正系數(shù),按混凝上結(jié)構(gòu)設(shè)計(jì)規(guī)范 GB50010第832條的規(guī)龍取用,當(dāng)多于一項(xiàng)時(shí),可按
19、連乘計(jì)算,但不應(yīng)小于0.6。3當(dāng)錨固鋼筋的保護(hù)層厚度不大于5時(shí),錨固長(zhǎng)度范用內(nèi) 應(yīng)配置橫向構(gòu)造鋼筋,苴直徑不應(yīng)小于d/4:對(duì)梁、柱、斜撐等構(gòu) 件間距不應(yīng)大于5d,對(duì)板、墻等平面構(gòu)件間距不應(yīng)大于10d,且 均不應(yīng)大于100mm,此處d為錨固鋼筋的直徑。6.2.2當(dāng)縱向受拉鋼筋末端采用機(jī)械錨固措施時(shí),鋼筋機(jī)械錨固 的錨固長(zhǎng)度(包括彎鉤或錨固端頭在內(nèi)的錨固長(zhǎng)度)可取0.6/初。機(jī) 械錨固的形式及構(gòu)造要求應(yīng)符合混凝上結(jié)構(gòu)設(shè)訃規(guī)范GB 50010的規(guī)左。6.2.3混凝丄結(jié)構(gòu)中的縱向受壓鋼筋,當(dāng)il算中充分利用苴抗壓 強(qiáng)度時(shí),錨固長(zhǎng)度不應(yīng)小于相應(yīng)受拉錨固長(zhǎng)度的70%o受壓鋼筋不應(yīng)采用末端彎鉤和一側(cè)貼焊錨筋
20、的錨固措施。受壓鋼筋錨固長(zhǎng)度范囤內(nèi)的橫向構(gòu)造鋼筋應(yīng)符合本標(biāo)準(zhǔn)第 6.2.1條的有關(guān)規(guī)定。6.3鋼筋的連接6.3.1鋼筋的連接可采用綁扎搭接、機(jī)械連接或焊接。6.3.2軸向受拉及小偏心受拉桿件的縱向受力鋼筋不得采用綁扎 搭接:其他構(gòu)件中的鋼筋采用綁扎搭接時(shí),受拉鋼筋直徑不宜大 于25mm,受壓鋼筋直徑不宜大于28mm。鋼筋的綁扎搭接長(zhǎng)度 應(yīng)符合混凝土結(jié)構(gòu)設(shè)計(jì)規(guī)范GB 50010的規(guī)泄。6.3.3機(jī)械連接宜用于直徑不小于14mm的受力鋼筋的連接,機(jī) 械連接類(lèi)型及質(zhì)量要求應(yīng)符合鋼筋機(jī)械連接技術(shù)規(guī)程JGJ107 的規(guī)定。6.3.4當(dāng)采用焊接連接時(shí),必須進(jìn)行現(xiàn)場(chǎng)條件下的焊接工藝試驗(yàn), 并經(jīng)試驗(yàn)合格后方準(zhǔn)
21、于焊接生產(chǎn)。各類(lèi)焊接方法的具體要求和適 用范國(guó)按鋼筋焊接及驗(yàn)收規(guī)程JGJ18中的相關(guān)規(guī)立執(zhí)行。6.4縱向受力鋼筋的最小配筋率6.4.1非抗喪設(shè)計(jì)時(shí),鋼筋混凝土構(gòu)件中的縱向受力鋼筋的配筋百 分率如濟(jì)不應(yīng)小于表641規(guī)定的數(shù)值。表6.4.1縱向受力鋼筋的最小配筋百分率p”湖(%)受力類(lèi)型最小配筋百分率受圧構(gòu)件全部縱向鋼筋0.50i側(cè)縱向鋼筋0.20受彎構(gòu)件、備心受拉.軸心受拉構(gòu)件一側(cè)的受拉鋼筋0.20和0.45/ fy中的較大值注:1受壓構(gòu)件全部縱向鋼筋駁小配筋百分率.當(dāng)采用C60以上強(qiáng)度等級(jí)的混凝上時(shí).應(yīng)按照表中規(guī)定増加002板類(lèi)受彎構(gòu)件(不包括懸杵板的受拉鋼筋.勻采用強(qiáng)度等級(jí)6()0MPa鋼筋
22、時(shí)其 故小配筋百分率應(yīng)允許采用0.15和0.45fjfr3佩心受拉構(gòu)件中的受壓鋼筋.應(yīng)按受壓構(gòu)件一側(cè)縱向鋼筋考電.4受壓構(gòu)件的全部縱向制筋和一側(cè)縱向鋼筋的配筋率以及軸心受拉構(gòu)件和小偏心受拉 構(gòu)件一側(cè)受拉鋼筋的配筋率均應(yīng)按構(gòu)件的全砂面面積計(jì)第。5受彎構(gòu)件人俯心受拉構(gòu)件一側(cè)受拉鋼筋的配筋率應(yīng)按全截面面積扣除受壓翼緣面 枳(b,-硯 后的栽面面積計(jì)如6當(dāng)鋼筋沿構(gòu)件栽而周邊布置時(shí).“一側(cè)縱向鋼筋”系折沿受力方向兩個(gè)對(duì)邊中的一 邊布置的縱向鋼筋。7臥置于地基上的混離上板板中受拉鋼筋的J8小配筋率町適當(dāng)降低,但不應(yīng)小于0,15%.197抗震設(shè)計(jì)7.0.1梁、柱、支撐以及剪力墻邊緣構(gòu)件中,苴縱向受力鋼筋宜采
23、 用熱軋帶肋鋼筋,當(dāng)采用熱軋帶肋牌號(hào)為HRB600E鋼筋時(shí),其 強(qiáng)度和禪性模量應(yīng)符合本標(biāo)準(zhǔn)第4.0.2條和第4.0.3條相應(yīng)的規(guī)立。 7.0.2對(duì)有抗震設(shè)防要求的結(jié)構(gòu),其縱向受力鋼筋的性能應(yīng)滿足 設(shè)計(jì)要求:當(dāng)設(shè)計(jì)無(wú)具體要求時(shí),對(duì)按一、二、三級(jí)抗震等級(jí)設(shè) 計(jì)的框架和斜撐構(gòu)件(含梯段)中的縱向受力鋼筋應(yīng)采用 HRB600E鋼筋,英強(qiáng)度和最大力下總伸長(zhǎng)率的實(shí)測(cè)值應(yīng)符合下 列規(guī)泄:1鋼筋的抗拉強(qiáng)度實(shí)測(cè)值與屈服強(qiáng)度實(shí)測(cè)值的比值不應(yīng)小于1.25;2鋼筋的屈服強(qiáng)度實(shí)測(cè)值與屈服強(qiáng)度標(biāo)準(zhǔn)值的比值不應(yīng)大于1.30;3鋼筋最大拉力下的總伸長(zhǎng)率實(shí)測(cè)值不應(yīng)小于9%。7.0.3采用熱軋帶肋髙強(qiáng)鋼筋的框架梁,其縱向鋼筋的配
24、置應(yīng)符合 下列要求:1梁端混凝土受壓區(qū)高度應(yīng)符合混凝上結(jié)構(gòu)設(shè)計(jì)規(guī)范GB 50010第11.3.1條的規(guī)定:2縱向受拉鋼筋的配筋率不應(yīng)小于表7.0.3-1規(guī)左的數(shù)值:3框架梁梁端截面的底部和頂部縱向受力鋼筋截面面積的比 值,除按計(jì)算確住外,一級(jí)抗震等級(jí)不應(yīng)小于0.5:二、三級(jí)抗喪 等級(jí)不應(yīng)小于0.3:4梁端箍筋的加密區(qū)長(zhǎng)度、箍筋最大間距和箍筋最小直徑, 應(yīng)按表7.0.3-2采用:當(dāng)梁端縱向受拉鋼筋配筋率大于2詼時(shí),表 中箍筋最小直徑應(yīng)增大2mm。表7.O.3-1框架梁縱向受拉鋼筋的最小配筋百分率(強(qiáng))抗離等級(jí),2行支座跨中一級(jí)0.4080£/人中的較大值0.30和65 f中的較人值二級(jí)
25、0.30和65/人中的較大值0.25和55 “人中的較大值三、四級(jí)0.25和中的較大值0.20和45/中的較大值表7.0.3-2框架梁梁端箍筋加密區(qū)的構(gòu)造要求抗健加密區(qū)長(zhǎng)度薙筋最大御距最小宜徑等級(jí)(mm)(mm)(mm)2 f咅梁高和500中的較人値縱向鋼筋宜徑的6倍.梁高的1/4和100中的聶小值10二級(jí)縱向鋼筋宜徑的1倍.梁島的”4和100中的聶小值8三級(jí)】5倍梁高和500中的較犬值縱向鋼筋宜徑的1倍.梁島的”4和150中的最小值8四級(jí)縱向鋼筋宜徑的8倍.梁高的1/4和150中的最小值6注:箝筋宜徑人干12mm、數(shù)址不少干4肢且肢跖不人干150mm時(shí).一、二級(jí)的竝人何距應(yīng)允許適當(dāng)放寬但不得
26、人于15()mnu7.0.4框架柱和框支柱的鋼筋配巻,應(yīng)符合下列要求:1框架柱和框支柱中全部縱向受力鋼筋的配筋百分率不應(yīng) 小于表7.0.4的規(guī)立,同時(shí),每一側(cè)的配筋百分率不應(yīng)小于0.2: 對(duì)IV類(lèi)場(chǎng)地上較髙的髙層建筑,最小配筋百分率應(yīng)增加0.1:表704柱全部縱向受力鋼筋最小配筋百分率(掘)柱類(lèi)型抗靈等級(jí)一級(jí)二級(jí)三級(jí)四級(jí)中柱、邊柱0.9 <1.0)0.7 (0.8)0.6 (0.7)0.5 (0.6)角柱、框支柱10.90.80.7注:1表中括號(hào)內(nèi)數(shù)值用干框架結(jié)構(gòu)的柱:2當(dāng)混凝土強(qiáng)度等級(jí)為C60以上時(shí),應(yīng)按表中數(shù)值增加0.1采用.2框架柱和框支柱中全部縱向受力鋼筋配筋率不應(yīng)大于5%。 柱
27、的縱向鋼筋宜對(duì)稱配置。截面尺寸大于400mm的柱,縱向鋼筋 的間距不宜大于200mmo當(dāng)按一級(jí)抗喪等級(jí)設(shè)汁,且柱的剪跨比 不大于2時(shí),柱每側(cè)縱向鋼筋的配筋率不宜大于1.2%。7.0.5框架柱和框支柱的箍筋配苣,應(yīng)符合下列要求:1框架柱和框支柱上、下兩端的箍筋應(yīng)加密,加密區(qū)的箍筋 最大間距和箍筋最小直徑應(yīng)符合表7.0.5的規(guī)泄。表7.0.5柱端箍筋加密區(qū)的構(gòu)造要求抗震等級(jí)薙筋最人間距(nun)益筋敬小宜徑(mm)一級(jí)縱向鋼筋宜徑的6倍和100中的牧小值10二級(jí)縱向鋼筋宜徑的8倍和100中的牧小值8三級(jí)縱向鋼筋宜徑的8倍和150 (柱根100)中的牧小值8四級(jí)縱向鋼筋宜徑的8倍和150 (柱根10
28、0)中的牧小值6(柱根8)柱根系描底層柱卜端的薙筋加密區(qū)范用.2框支柱和剪跨比不大于2的框架柱應(yīng)在柱全高范圍內(nèi)加 密箍筋,且箍筋間距應(yīng)符合表7.0.5中一級(jí)抗震等級(jí)的要求。3 一級(jí)抗震等級(jí)框架柱的箍筋直徑大于12mm且箍筋肢距 不大于150mm及二級(jí)抗箴等級(jí)框架柱的直徑不小于10mm且箍 筋肢距不大于200mm時(shí),除底層柱下端外,箍筋間距應(yīng)允許采用 150mm:四級(jí)抗震等級(jí)框架柱剪跨比不大于2時(shí),箍筋直徑不應(yīng) 小于8mm。4框架柱的箍筋加密區(qū)長(zhǎng)度,應(yīng)取柱截而長(zhǎng)邊尺寸(或圓形截 而直徑)、柱凈高的1/6和500mm中的最大值:一、二級(jí)抗震等 級(jí)的角柱應(yīng)沿柱全高加密箍筋。底層柱根箍筋加密區(qū)長(zhǎng)度應(yīng)取
29、不 小于該層柱凈高的1/3:當(dāng)有剛性地面時(shí),除柱端箍筋加密區(qū)外尚 應(yīng)在剛性地而上、下各500mm的高度范困內(nèi)加密箍筋。7.0.6箍筋加密區(qū)箍筋的體積配筋率應(yīng)符合下列規(guī)左。1柱箍筋加密區(qū)箍筋的體積配筋率,應(yīng)符合下列規(guī)宦:A>A(7°6)式中:px一一柱箍筋加密區(qū)的體積配筋率,計(jì)算中應(yīng)扣除重疊部 分的箍筋體積:A-箍筋的抗拉強(qiáng)度設(shè)計(jì)值:fc混凝上軸心抗壓強(qiáng)度設(shè)計(jì)值:當(dāng)強(qiáng)度等級(jí)低于C35 時(shí).按C35取值:最小配箍特征值,按表7.0.6采用。 表7.0.6柱箍筋加密區(qū)的箍筋最小配箍特征值人抗罷等級(jí)箍筋形式軸壓比<0.30.4050.60.70.80.91.01.05級(jí)普軸箍、災(zāi)
30、合箍().11030.150.200.23螺皈箍、復(fù)合或連續(xù)復(fù)合矩形0.080.09010305080.21普通箍、復(fù)合掘0.080.0901030.1507090.220.24螺皈箍、復(fù)合或連續(xù)復(fù)合矩形螺旋箍0.060.070.090.11030.15070.200.22級(jí)普通箍、復(fù)合掘0.060.070.090.11030.15070.200.22螺皈箍、災(zāi)合或 連續(xù)復(fù)合矩形0.050.060.070.090.110305080.20注:1普通箍播單個(gè)矩形撿筋或單個(gè)關(guān)形薙筋:嫌?xùn)V箍折單個(gè)螺族撿筋:復(fù)合掘播由矩形.等邊形.州形益筋或拉筋組成的箍筋:繪介螺族薙描由螺旋箍峙矩形.多邊形、闕形箍筋
31、或拉筋組成的箍筋:連續(xù)復(fù)合矩形螺就撿描全部螺旋箍為同一根鋼筋加工成ffJM:2在il以復(fù)合螺旋箍的體枳配筋率時(shí)其中非煤族掘筋的體枳應(yīng)乘以系«(0.8:3混凝上強(qiáng)度等級(jí)髙干。60時(shí)潑筋宜采用雄臺(tái)養(yǎng)、奴合螺旋掘或連續(xù)級(jí)合矩形螺旋 瓶 當(dāng)軸壓比不人于0.6時(shí).其加密區(qū)的彊小配養(yǎng)持征值宜按農(nóng)中數(shù)值增加()02:當(dāng)軸壓比 人于0.6時(shí).宜按表中數(shù)伍增加0.0九2對(duì)一、二、三、四級(jí)抗震等級(jí)的柱,其箍筋加密區(qū)的箍筋 體積配筋率分別不應(yīng)小于0.8%、0.6%. 0.4%和0.4%:3框支柱宜采用復(fù)合螺旋箍或井字復(fù)合箍,英最小配箍特征 值應(yīng)按表7.0.6中的數(shù)值增加0.02取用,且體積配筋率不應(yīng)小于
32、1.5%:4當(dāng)剪跨比入不大于2時(shí),一、二、三級(jí)抗震等級(jí)的柱宜采 用復(fù)合螺旋箍或井字復(fù)合箍,英箍筋體積配筋率不應(yīng)小于1.2%; 設(shè)防烈度為9度時(shí),不應(yīng)小于1.5%。7.0.7對(duì)于框架中間層中間節(jié)點(diǎn)、中間層端節(jié)點(diǎn)、頂層中間節(jié)點(diǎn)以 及頂層端節(jié)點(diǎn),梁、柱縱向鋼筋在節(jié)點(diǎn)部位的錨固或搭接,除應(yīng) 20符合本標(biāo)準(zhǔn)第6.2節(jié)和第6.3節(jié)的有關(guān)規(guī)左外,尚應(yīng)符合下列要求: 1縱向受拉鋼筋的抗震錨固長(zhǎng)度/嬉及抗震搭接長(zhǎng)度“按 照混凝丄結(jié)構(gòu)設(shè)計(jì)規(guī)范GB 50010第11丄7條規(guī)左取值。2縱向受力鋼筋的連接可采用綁扎搭接、機(jī)械連接或焊接。3 縱向受力鋼筋連接的位程宜避開(kāi)梁端、柱端箍筋加密區(qū);如必須在此連接時(shí),應(yīng)采用機(jī)械連
33、接或焊接。4混凝上構(gòu)件位于同一連接區(qū)段內(nèi)的縱向受力鋼筋接頭而積 百分率不宜超過(guò)50%7.0.8 一、二、三、四級(jí)抗震等級(jí)的各類(lèi)結(jié)構(gòu)的框架柱、框支柱, 其軸壓比不宜大于表7.0.8規(guī)沱的限值。對(duì)IV類(lèi)場(chǎng)地上較髙的高 層建筑,柱軸壓比限值應(yīng)適當(dāng)減小。表7.0.8柱軸壓比限值結(jié)構(gòu)體系一級(jí)二級(jí)三級(jí)四級(jí)框架結(jié)構(gòu)0.650.750.850.90框架朗力墻結(jié)構(gòu)、簡(jiǎn)體結(jié)構(gòu)0.750.850.900.95部分框支剪力墻結(jié)構(gòu)0.600.70注:1軸壓比播柱地羅作用組合的軸向壓力設(shè)il值與柱的全截面面枳和混畝上軸心抗壓賤度設(shè)計(jì)值乘枳之比值:2當(dāng)混凝上強(qiáng)度等級(jí)為C65、C70時(shí).軸壓比限值宜按表中數(shù)值減小0.05:混
34、凝上儀 度等級(jí)為C75、。80時(shí)軸壓比限值宜按茨中數(shù)值減小0.1():3衣內(nèi)限值適用于剪跨比人于2且混凝上儀度等級(jí)不奇于C60的柱:明跨比不人于2的柱軸壓比限值應(yīng)降低0.05:明跨比小干1.5的柱.軸壓比限值應(yīng):門(mén)研憲并采取特殊構(gòu)適描施:4沿柱全島采用井字奴合狷且掘筋間距不人于lOOnun、肢距不大于2(X)mnK宜徑不 小于12mm或沿柱全烏采用奴介螺旋掘.11螺距不人于100mm、肢距不人干2()()mm宜 徑不小干12mm.或沿柱全高采用連續(xù)復(fù)合矩形螺旋薇且螺施凈距不80mm.肢距不 人于200mm、直徑不小干10mm時(shí).軸壓比限值均町按茨中數(shù)值增加0.10:5當(dāng)柱戴面中部設(shè)置山附加縱向
35、鋼筋形成的芯柱.且附加縱向鋼筋的總截面面枳不少 于柱截面面稅的0.8皤時(shí).軸壓比限值町按表中數(shù)值增加0.05:此項(xiàng)措施與注4的措施同時(shí) 采用時(shí).軸壓比限值對(duì)按表中數(shù)血增加0.15.但薙筋的配薙特征值仍應(yīng)按軸樂(lè)比增加0.10 的要求確定:6調(diào)療后的柱軸壓比限值不應(yīng)大于1.05.418施工及質(zhì)量驗(yàn)收8.1施工措施&1.1采用熱軋帶肋高強(qiáng)鋼筋的混凝上結(jié)構(gòu)工程施工除符合本標(biāo) 準(zhǔn)要求外,尚應(yīng)符合現(xiàn)行國(guó)家標(biāo)準(zhǔn)混凝上結(jié)構(gòu)工程施工規(guī)范 GB 50666的相關(guān)規(guī)建。8.1.2鋼筋的牌號(hào)、強(qiáng)度級(jí)別或規(guī)格應(yīng)按設(shè)計(jì)文件的規(guī)左采用。 當(dāng)需用熱軋帶肋高強(qiáng)鋼筋代換其他強(qiáng)度等級(jí)的鋼筋時(shí),應(yīng)經(jīng)設(shè)訃 單位同意,并應(yīng)辦理設(shè)
36、計(jì)變更文件。鋼筋代換除應(yīng)遵守構(gòu)件承載力相等的代換原則以外,尚應(yīng)復(fù) 核:最小配筋率、保護(hù)層厚度、裂縫寬度、剛度、錨固長(zhǎng)度、搭 接長(zhǎng)度、焊接接頭及機(jī)械連接接頭的型式檢驗(yàn)等。&1.3鋼筋宜采用不具有延伸功能的機(jī)械設(shè)備進(jìn)行調(diào)直。當(dāng)采用冷 拉方法調(diào)直時(shí),熱軋帶肋鋼筋的冷拉率不宜大于1%。鋼筋調(diào)直過(guò) 程中不應(yīng)損傷帶肋鋼筋的橫肋。調(diào)直后的鋼筋應(yīng)平直,不應(yīng)有局 部彎折。鋼筋不得采用冷拉方法提高強(qiáng)度。&1.4鋼筋的彎折應(yīng)符合下列規(guī)定:1當(dāng)直徑為28mm以下時(shí),彎弧內(nèi)直徑不應(yīng)小于鋼筋直徑的6 倍。2當(dāng)直徑為28mm及以上時(shí),彎弧內(nèi)直徑不應(yīng)小于鋼筋直徑的 7倍。3箍筋彎折處彎弧內(nèi)直徑尚不應(yīng)小于縱向受
37、力鋼筋的直徑。&1.5當(dāng)箍筋采用在拐角處搭接的方式時(shí),其末端應(yīng)作彎鉤。對(duì)有 抗震和受扭承載力要求構(gòu)件中的箍筋,應(yīng)作135。彎鉤,彎后平直 段長(zhǎng)度不應(yīng)小于10厶&1.6縱向受力鋼筋的連接方式應(yīng)符合設(shè)計(jì)要求。縱向受力鋼筋的連接接頭宜設(shè)程在受力較小處:接頭末端至 鋼筋彎起點(diǎn)的距離不應(yīng)小于10(為鋼筋的公稱直徑)。同一跨度或同一節(jié)間內(nèi)的縱向受力鋼筋不宜設(shè)豊兩個(gè)或兩 個(gè)以上接頭。有抗震要求的框架柱、梁,不宜在端部的箍筋加密區(qū)內(nèi)設(shè)垃 縱向鋼筋接頭。&1.7鋼筋機(jī)械連接接頭等級(jí)的選用應(yīng)符合下列規(guī)左:1混凝丄結(jié)構(gòu)中要求充分發(fā)揮鋼筋強(qiáng)度或?qū)ρ有砸筝^髙的 部位應(yīng)選用II級(jí)或【級(jí)接頭:當(dāng)在
38、同一連接區(qū)段內(nèi)必須實(shí)施100% 鋼筋接頭的連接時(shí),應(yīng)采用【級(jí)接頭。2混凝上結(jié)構(gòu)中鋼筋應(yīng)力較髙但對(duì)延性要求不髙的部位可采 用III級(jí)接頭。&1.8鋼筋機(jī)械連接應(yīng)符合下列規(guī)左:I鋼筋絲頭現(xiàn)場(chǎng)加工與接頭安裝應(yīng)按接頭技術(shù)提供單位的加 工、安裝技術(shù)要求進(jìn)行,操作工人應(yīng)經(jīng)專業(yè)培訓(xùn)合格后上崗。2鋼筋絲頭加工與接頭安裝應(yīng)經(jīng)工藝檢驗(yàn)合格后方可進(jìn)行。3直螺紋鋼筋絲頭長(zhǎng)度應(yīng)滿足產(chǎn)品設(shè)計(jì)要求,極限偏差應(yīng)為 02.0/兒4直螺紋接頭的鋼筋絲頭宜滿足甘級(jí)精度要求,應(yīng)用專用直 螺紋雖:規(guī)檢驗(yàn),通規(guī)能順利旋入并達(dá)到要求的擰入長(zhǎng)度,止規(guī)旋 入不得超過(guò)3“。5錐螺紋鋼筋線頭長(zhǎng)度應(yīng)滿足產(chǎn)品設(shè)計(jì)要求,擰緊后的鋼筋絲 頭不得相
39、互接觸,絲頭加工長(zhǎng)度極限偏差應(yīng)為-O.5p-l.5p.6鋼筋絲頭的錐度和螺距應(yīng)采用專用錐螺紋量規(guī)檢驗(yàn)。注:P為螺距:6f級(jí)精度要求可參考現(xiàn)行國(guó)家標(biāo)準(zhǔn)普通螺紋公差GB/T 197 中的相關(guān)現(xiàn)定。&1.9鋼筋焊接施工應(yīng)符合下列規(guī)定:1從事鋼筋焊接施工的焊工應(yīng)持有鋼筋焊工考試合格證,并 應(yīng)按照合格證規(guī)定的范圍上崗操作??v向受力鋼筋的焊接連接應(yīng)按行業(yè)標(biāo)準(zhǔn)鋼筋焊接及驗(yàn)收規(guī) 程JGJ 18的規(guī)泄進(jìn)行鋼筋焊接施工。2在鋼筋工程焊接施工前,參與該項(xiàng)工程施焊的焊工應(yīng)進(jìn)行 現(xiàn)場(chǎng)條件下的焊接工藝試驗(yàn),經(jīng)試驗(yàn)合格后,方可進(jìn)行焊接。3電渣壓力焊只應(yīng)使用于柱、墻等現(xiàn)澆混凝上構(gòu)件中豎向受 力鋼筋的連接。8.2質(zhì)呈驗(yàn)
40、收8.2.1采用熱軋帶肋髙強(qiáng)鋼筋的混凝土結(jié)構(gòu)工程的質(zhì)量驗(yàn)收,應(yīng)符 合現(xiàn)行國(guó)家標(biāo)準(zhǔn)混凝土結(jié)構(gòu)工程施工質(zhì)量驗(yàn)收規(guī)范GB 50204 的規(guī)疋。8.2.2在澆筑混凝上之前,應(yīng)進(jìn)行鋼筋隱蔽工程驗(yàn)收,其內(nèi)容包括:1縱向受力鋼筋的牌號(hào)、規(guī)格、數(shù)量、位置等;2鋼筋的連接方式、接頭位置、接頭質(zhì)量、接頭而積百分率、 搭接長(zhǎng)度、錨固方式及錨固長(zhǎng)度;3箍筋、橫向鋼筋的牌號(hào)、規(guī)格、數(shù)量、間距,箍筋彎鉤的 彎折角度及平直段長(zhǎng)度:4預(yù)埋件的規(guī)格、數(shù)量、位置等。8.2.3鋼筋應(yīng)有岀廠質(zhì)量證明書(shū)或試驗(yàn)報(bào)告單,鋼筋表面或每捆 (盤(pán))鋼筋均應(yīng)有標(biāo)志,并應(yīng)確認(rèn)符合鋼筋訂貨的牌號(hào)。8.2.4鋼筋應(yīng)按爐罐(批)號(hào)及直徑分批進(jìn)場(chǎng),并應(yīng)按國(guó)
41、家標(biāo)準(zhǔn)鋼 筋混凝上用鋼:第2部分熱軋帶肋鋼筋GB 1499.2規(guī)立的力學(xué)性 能和重量偏差指標(biāo)進(jìn)行進(jìn)場(chǎng)檢驗(yàn)。8.2.5鋼筋在加工過(guò)程中,當(dāng)發(fā)現(xiàn)鋼筋脆斷、焊接性能不良或力 學(xué)性能顯著不正常等現(xiàn)象,應(yīng)對(duì)該批鋼筋進(jìn)行化學(xué)成分檢驗(yàn)或其 他專項(xiàng)檢驗(yàn)。8.2.6成型鋼筋進(jìn)場(chǎng)時(shí),應(yīng)抽取試件作屈服強(qiáng)度、抗拉強(qiáng)度、伸 長(zhǎng)率和重量偏差檢驗(yàn),檢驗(yàn)結(jié)果應(yīng)符合國(guó)家現(xiàn)行相關(guān)標(biāo)準(zhǔn)的規(guī)左。當(dāng)有施工單位或監(jiān)理單位的代表駐廠監(jiān)督生產(chǎn)過(guò)程并提供原 材鋼筋力學(xué)性能第三方檢驗(yàn)報(bào)告時(shí),可僅進(jìn)行重量偏差檢驗(yàn)。 8.2.7鋼筋焊接施工前應(yīng)按行業(yè)標(biāo)準(zhǔn)鋼筋焊接及驗(yàn)收規(guī)程JGJ 18 的要求進(jìn)行檢驗(yàn),確認(rèn)合格后方可正式施工。對(duì)于采用焊接方式連接的細(xì)
42、晶粒熱軋帶肋鋼筋和直徑大于 25mm的600MPa鋼筋,應(yīng)進(jìn)行專門(mén)檢驗(yàn)。8.2.8鋼筋機(jī)械連接及鋼筋錨固板施工前,應(yīng)提供型式檢驗(yàn)報(bào)告, 并按鋼筋機(jī)械連接通用技術(shù)規(guī)程JGJ 107、鋼筋錨固板應(yīng)用 技術(shù)規(guī)程JGJ256的要求進(jìn)行施工現(xiàn)場(chǎng)抽樣檢驗(yàn),合格后方可用 于工程。附錄A帶肋鋼筋的標(biāo)志A.1.1鋼筋混凝丄用鋼筋有光圓及帶肋(月牙肋)兩種外形,在鋼筋 表而用下列刻字標(biāo)志表示:1帶肋鋼筋表面上軋制的第一個(gè)字母表示鋼種:無(wú)字母表示 普通熱軋鋼筋;“C”表示細(xì)晶粒熱軋鋼筋;“K”表示余熱處理 鋼筋:數(shù)字后字母“E”表示抗震鋼筋;2帶肋鋼筋表面上軋制的最后一組數(shù)字為公稱直徑,以毫米 (mm)為單位的阿拉
43、伯?dāng)?shù)字表示。例如16、25表示鋼筋的公稱直 徑為16mm、25mm;直徑12mm以下的細(xì)鋼筋不標(biāo)志直徑;3光圓鋼筋表而無(wú)標(biāo)志,強(qiáng)度只有一種,直徑可直接量測(cè):A.1.2普通熱軋鋼筋(HRB)在其表面刻有3、4、5、6分別表示牌 號(hào)為 HRB335、HRB400、HRB500. HRB600 的普通熱軋鋼筋; 刻有3E、4E、5E、6E分別表示牌號(hào)為HRB335E、HRB400E. HRB500E. HRB600E 的抗震鋼筋。A.1.3細(xì)晶粒熱軋鋼筋(HRBF)在其表面用C3、C4、C5、C6分別 表示牌號(hào)為 HRBF335、HRBF400. HRBF500. HRBF600 的細(xì)晶 粒熱軋鋼筋
44、;用C3E、C4E、C5E、C6E分別表示牌號(hào)為HRBF335E、 HRBF400E. HRBF500E. HRBF600E 的抗震鋼筋。附錄B 600MPa鋼筋的公稱直徑及公稱截面面積公稱宜徑(mm)不同根數(shù)鋼筋的公旳戡面面枳(sm:)123456789850.31011512012523023524024531078.515723631439347155()62870712113.5226339452565678791904101714153.930846161576992310771230138716201X)5120614071608180918254.550
45、976310171272152617802036229020314.262894112561570188422002513282722380.1760114015201900228126613(M1342125490.9982147319642454294534363927441828615.81232184724633079369543104926554232804.316092418321740214826563064347238361017.9203630544072508961077125814391614012562513377050276283754087961005311310目
46、次1總 則343基本規(guī)定354材料375結(jié)構(gòu)分析及極限狀態(tài)計(jì)算396構(gòu)造規(guī)泄406混凝土保護(hù)層406.2鋼筋的錨固416.3鋼筋的連接426.4縱向受力鋼筋的最小配筋率437抗震設(shè)計(jì)448施工及質(zhì)疑驗(yàn)收48施工措施488.2質(zhì)疑驗(yàn)收481.0.1編制標(biāo)準(zhǔn)是為落實(shí)國(guó)家的技術(shù)經(jīng)濟(jì)政策,推廣應(yīng)用高強(qiáng)鋼筋, 以達(dá)到省材、節(jié)能、降耗、環(huán)保的目的。同時(shí)在混凝丄結(jié)構(gòu)中應(yīng) 用髙強(qiáng)鋼筋還可以減輕結(jié)構(gòu)自重:解決鋼筋密集問(wèn)題:方便澆筑 施工:保證工程質(zhì)量。1.0.2本標(biāo)準(zhǔn)的應(yīng)用范圍為采用600MPa鋼筋作受力鋼筋的混凝上 結(jié)構(gòu),包括設(shè)計(jì)、施工及驗(yàn)收等方而的技術(shù)要求。1.0.3在應(yīng)用髙強(qiáng)鋼筋時(shí),除應(yīng)滿足本標(biāo)準(zhǔn)的要求外
47、,其余技術(shù)要 求尚應(yīng)符合現(xiàn)行國(guó)家標(biāo)準(zhǔn)建筑結(jié)構(gòu)荷載規(guī)范GB 50009、混 凝上結(jié)構(gòu)設(shè)計(jì)規(guī)范GB 50010、建筑抗震設(shè)訃規(guī)范GB 50011、混凝土結(jié)構(gòu)工程施工質(zhì)量驗(yàn)收規(guī)范GB 50204、鋼筋混凝上 用鋼第2部分:熱軋帶肋鋼筋GB 1499.2等標(biāo)準(zhǔn)的相關(guān)規(guī)左。3基本規(guī)定3.0.1熱軋帶肋髙強(qiáng)鋼筋的適用范用與一般鋼筋相同,且可與其 他類(lèi)型的鋼筋搭配使用。推薦優(yōu)先用于混凝上梁、板中的縱向受 拉鋼筋。對(duì)僅做承載能力極限狀態(tài)訃算的鋼筋混凝上結(jié)構(gòu)構(gòu)件中 的受力鋼筋和預(yù)應(yīng)力混凝上結(jié)構(gòu)構(gòu)件中的非預(yù)應(yīng)力受力鋼筋,宜 采用600MPa鋼筋。對(duì)于由承載能力極限狀態(tài)控制配筋的抗爆設(shè) 計(jì)人防結(jié)構(gòu)和抗倒塌設(shè)訃結(jié)構(gòu),
48、以及預(yù)應(yīng)力混凝上結(jié)構(gòu)構(gòu)件中的 非預(yù)應(yīng)力受力鋼筋,推薦優(yōu)先采用600MPa鋼筋,以達(dá)到節(jié)省鋼 材用量的目的。3.0.2承載能力極限狀態(tài)設(shè)汁的基本表達(dá)式,與混凝上結(jié)構(gòu)設(shè) 計(jì)規(guī)范GB 50010的規(guī)能完全一致。3.0.3正常使用極限狀態(tài)設(shè)計(jì)的基本表達(dá)式,與混凝上結(jié)構(gòu)設(shè) 計(jì)規(guī)范GB 50010的規(guī)定完全一致。3.0.4懸臂構(gòu)件是工程實(shí)踐中容易發(fā)生事故的構(gòu)件,混凝上結(jié)構(gòu) 設(shè)計(jì)規(guī)范GB 50010表3.4.3注1中規(guī)定設(shè)計(jì)時(shí)對(duì)英撓度的控制 要求:表注4中參照歐洲標(biāo)準(zhǔn)EN 1992的規(guī)立,提出了起拱、反 拱的限制,目的是為防止起拱、反拱過(guò)大引起的不良影響。當(dāng)構(gòu) 件的撓度滿足混凝土結(jié)構(gòu)設(shè)計(jì)規(guī)范GB 50010
49、表3.4.3的要求, 但相對(duì)使用要求仍然過(guò)大時(shí),設(shè)計(jì)時(shí)可根據(jù)實(shí)際情況提岀比表括 號(hào)中的限制更加嚴(yán)格的要求。3.0.5工程實(shí)踐以及與國(guó)外標(biāo)準(zhǔn)規(guī)立的對(duì)比都表明,我國(guó)現(xiàn)行規(guī) 范中對(duì)于受力裂縫寬度的控制偏嚴(yán),可作適當(dāng)放松。對(duì)結(jié)構(gòu)構(gòu)件 正截而的裂縫控制等級(jí),仍按混凝上結(jié)構(gòu)設(shè)計(jì)規(guī)范GB 50010 劃分為三個(gè)等級(jí)。裂縫控制等級(jí)劃分為三級(jí),等級(jí)是對(duì)裂縫控制 嚴(yán)格程度而言的,設(shè)計(jì)人員根據(jù)具體情況選用不同的等級(jí)。關(guān)于 構(gòu)件裂縫控制等級(jí)的劃分,國(guó)際上一般都根拯結(jié)構(gòu)的功能要求、 環(huán)境條件對(duì)鋼筋的腐蝕影響、鋼筋種類(lèi)對(duì)腐蝕的敏感性和荷載作 用時(shí)間等因素來(lái)考慮。3.0.6結(jié)構(gòu)構(gòu)件的裂縫控制等級(jí)及最大裂縫寬度的限值,與混
50、凝上結(jié)構(gòu)設(shè)計(jì)規(guī)范GB 50010的規(guī)泄完全一致。4材料4.0.1本規(guī)程采用的熱軋帶肋鋼筋是指600MPa鋼筋。鋼筋的各 項(xiàng)性能應(yīng)符合規(guī)上,具體技術(shù)要求見(jiàn)本規(guī)程附錄A。4.0.2根據(jù)混凝土結(jié)構(gòu)設(shè)汁規(guī)范GB 50010規(guī)定,要求鋼筋標(biāo) 準(zhǔn)強(qiáng)度的保證率不應(yīng)小于95%0鋼筋混凝上用鋼第2部分:熱軋帶肋鋼筋GB 1499給出 了 HRB600鋼筋的屈服強(qiáng)度標(biāo)準(zhǔn)值(特征值)、抗拉強(qiáng)度標(biāo)準(zhǔn)值(特 征值)。4.0.3 600MPa鋼筋材料分項(xiàng)系數(shù)取1.15時(shí),強(qiáng)度設(shè)計(jì)值為 520N/mm2,分項(xiàng)系數(shù)取1.2時(shí),強(qiáng)度設(shè)計(jì)值為5OON/mm2,根據(jù) 試驗(yàn)結(jié)果,取值鋼筋強(qiáng)度設(shè)汁值為510N/mm2,裂縫寬度能夠滿
51、足限值要求。計(jì)算受剪、受扭、受沖切承載力取為360N/nim2; 根據(jù)髙強(qiáng)箍筋混凝上結(jié)構(gòu)設(shè)計(jì)規(guī)程CECS356:2013的規(guī)立,用 作國(guó)箍約束混凝土的間接鋼筋時(shí),苴強(qiáng)度設(shè)計(jì)值不受此限。河北工業(yè)大學(xué)2018年完成的12根偏心受壓柱的承載力試驗(yàn) 表明,600MPa鋼筋抗壓強(qiáng)度設(shè)計(jì)值廣y可取與抗拉強(qiáng)度不相同。 在偏心受壓狀態(tài)下,混凝上所能達(dá)到的壓應(yīng)變可以保證600MPa 鋼筋的抗壓強(qiáng)度達(dá)到與抗拉強(qiáng)度相同的值,但在大偏心受壓、受 彎承載力訃算時(shí),應(yīng)注意混凝上受壓區(qū)髙度過(guò)小時(shí)受壓鋼筋達(dá)不 到屈服強(qiáng)度;河北工業(yè)大學(xué)2018年完成的19根軸心受壓柱的承 載力試驗(yàn)表明,由于混凝上壓應(yīng)力達(dá)到&時(shí)混凝土壓
52、應(yīng)變?yōu)?.002, 當(dāng)采用600MPa鋼筋時(shí),其鋼筋的抗壓強(qiáng)度設(shè)計(jì)值取為400N/mm2。 4.0.4鋼筋混凝土用鋼第2部分:熱軋帶肋鋼筋GB 1499給 岀了 600MPa鋼筋的鋼筋延性(斷后伸長(zhǎng)率或最大力下總伸長(zhǎng)率) 特征值。4.0.5鋼筋混凝上用鋼第2部分:熱軋帶肋鋼筋GB 1499給出 了 600MPa鋼筋的彈性模量等設(shè)計(jì)參數(shù)。4.0.6為適應(yīng)高強(qiáng)鋼筋的要求,對(duì)混凝上強(qiáng)度等級(jí)作了適當(dāng)?shù)奶狍{。4.0.7鋼筋代換除應(yīng)滿足等強(qiáng)代換的原則外,尚應(yīng)綜合考慮不同鋼 筋牌號(hào)的性能差異對(duì)裂縫寬度驗(yàn)算、最小配筋率、抗震構(gòu)造要求 等的影響,并應(yīng)滿足鋼筋間距、保護(hù)層厚度、錨固長(zhǎng)度、搭接接 頭而積百分率及搭接
53、長(zhǎng)度等的要求。5結(jié)構(gòu)分析及極限狀態(tài)計(jì)算5.0.1與混凝上結(jié)構(gòu)設(shè)計(jì)規(guī)范GB 50010保持一致。5.0.2超靜左混凝丄結(jié)構(gòu)在出現(xiàn)塑性鐵的情況下,會(huì)發(fā)生內(nèi)力重分 布??衫眠@一特點(diǎn)進(jìn)行構(gòu)件截而之間的內(nèi)力調(diào)幅,以達(dá)到簡(jiǎn)化 構(gòu)造、節(jié)約配筋的目的。本條規(guī)泄給岀了可以采用塑性調(diào)幅設(shè)計(jì) 的構(gòu)件或結(jié)構(gòu)類(lèi)型。本條提出了考慮塑性內(nèi)力重分布分析方法設(shè)計(jì)的條件。按考慮塑 性內(nèi)力重分布的計(jì)算方法進(jìn)行構(gòu)件或結(jié)構(gòu)設(shè)計(jì)時(shí),由于塑性較的 出現(xiàn),構(gòu)件的變形和抗彎能力調(diào)小部位的裂縫寬度均較大。故進(jìn) 一步明確允許考慮塑性內(nèi)力重分布構(gòu)件的使用環(huán)境,并強(qiáng)調(diào)應(yīng)進(jìn) 行構(gòu)件變形和裂縫寬度驗(yàn)算,以滿足正常使用極限狀態(tài)的要求。 采用基于彈性分析的
54、塑性內(nèi)力重分布方法進(jìn)行彎矩凋幅時(shí),彎矩 調(diào)整的幅度及受壓區(qū)的髙度均應(yīng)滿足本條的規(guī)左,以保證構(gòu)件出 現(xiàn)塑性狡的位置有足夠的轉(zhuǎn)動(dòng)能力并限制裂縫寬度。由于本規(guī)程所指600MPa鋼筋的屈服強(qiáng)度較髙,相應(yīng)的相對(duì)界限 受壓區(qū)髙度較小,因此在設(shè)訃時(shí)應(yīng)注意英帶來(lái)的影響。5.0.3、5.0.4、5.0.5與混凝土結(jié)構(gòu)設(shè)計(jì)規(guī)范GB 50010保持一 致。6構(gòu)造規(guī)定6混凝土保護(hù)層6.1.1根據(jù)我國(guó)對(duì)混凝土結(jié)構(gòu)耐久性的調(diào)研及分析,并參考混 凝上結(jié)構(gòu)耐久性設(shè)計(jì)規(guī)范GB/T50476以及國(guó)外相應(yīng)規(guī)范、標(biāo)準(zhǔn) 的有關(guān)規(guī)左,對(duì)混凝土保護(hù)層的厚度進(jìn)行了以下調(diào)整:1混凝上保護(hù)層厚度不小于受力鋼筋直徑(單筋的公稱直徑 或并筋的等效直徑)的要求,是為了保證握裹層混凝上對(duì)受力鋼 筋的錨固。2從混凝上碳化、脫鈍和鋼筋銹蝕的耐久性角度考慮,不再 以縱向受力鋼筋的外緣,而以最外層鋼筋(包括箍筋、構(gòu)造筋、 分布筋等)的外緣計(jì)算混凝土保護(hù)層厚度。3簡(jiǎn)化表6.1.1的表達(dá):根據(jù)混凝土碳化反應(yīng)的差異和構(gòu)件 的重要性,按平而構(gòu)件(板、墻、殼)及桿狀構(gòu)件(梁、柱、桿) 分兩類(lèi)確左保護(hù)層厚度;表中不再列入強(qiáng)度等級(jí)的影響,C30及 以上統(tǒng)一取值,C25及以下均增加5mim4考慮碳化速度的影響,使用年限100年的結(jié)構(gòu),保護(hù)層 厚度取1.4倍。5為保證基礎(chǔ)鋼筋的耐久性
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025民間的借款合同范本2
- 2025搬家貨運(yùn)合同模板
- 2025年度年度水利工程設(shè)施維修管理協(xié)議3篇
- 二零二五年度2025年農(nóng)業(yè)合作社合伙人合同協(xié)議3篇
- 2025年度農(nóng)村房屋買(mǎi)賣(mài)合同(含房屋附屬設(shè)施及土地開(kāi)發(fā))
- 二零二五年度農(nóng)村住房建設(shè)智能化系統(tǒng)安裝合同
- 2025年度大學(xué)畢業(yè)生就業(yè)意向與培養(yǎng)協(xié)議3篇
- 2025年度出差環(huán)境保護(hù)與可持續(xù)發(fā)展協(xié)議3篇
- 二零二五年度新型農(nóng)村機(jī)井承包管理協(xié)議
- 2025年度體育用品商鋪?zhàn)赓U合同范本(含賽事贊助合作)3篇
- 新人教版七年級(jí)上冊(cè)初中數(shù)學(xué)全冊(cè)教材習(xí)題課件
- 2024年(全國(guó)教材培訓(xùn)專題系列)素養(yǎng)導(dǎo)向初中地理大單元教學(xué)課件
- 摔箱測(cè)試報(bào)告
- 四川省遂寧市城區(qū)遂寧市市城區(qū)初中2024年第一學(xué)期期末教學(xué)水平監(jiān)測(cè)七年級(jí)歷史試題(無(wú)答案)
- 建筑垃圾清運(yùn)投標(biāo)方案(技術(shù)方案)
- JTG F40-2004 公路瀝青路面施工技術(shù)規(guī)范
- JTG D50-2017公路瀝青路面設(shè)計(jì)規(guī)范
- 鄉(xiāng)鎮(zhèn)衛(wèi)生院管理制度及細(xì)則
- 天津市河北區(qū)2022-2023學(xué)年七年級(jí)上學(xué)期期末生物試題【帶答案】
- 2024年輔警招聘考試試題庫(kù)附完整答案(必刷)
- 伴瘤內(nèi)分泌綜合征課件
評(píng)論
0/150
提交評(píng)論