![GB 50689-2011 GB50689-2011通信局(站)防雷與接地工程設(shè)計規(guī)范:英文_第1頁](http://file4.renrendoc.com/view/9be77fe037ffa19942a9eac413b14bb9/9be77fe037ffa19942a9eac413b14bb91.gif)
![GB 50689-2011 GB50689-2011通信局(站)防雷與接地工程設(shè)計規(guī)范:英文_第2頁](http://file4.renrendoc.com/view/9be77fe037ffa19942a9eac413b14bb9/9be77fe037ffa19942a9eac413b14bb92.gif)
![GB 50689-2011 GB50689-2011通信局(站)防雷與接地工程設(shè)計規(guī)范:英文_第3頁](http://file4.renrendoc.com/view/9be77fe037ffa19942a9eac413b14bb9/9be77fe037ffa19942a9eac413b14bb93.gif)
![GB 50689-2011 GB50689-2011通信局(站)防雷與接地工程設(shè)計規(guī)范:英文_第4頁](http://file4.renrendoc.com/view/9be77fe037ffa19942a9eac413b14bb9/9be77fe037ffa19942a9eac413b14bb94.gif)
![GB 50689-2011 GB50689-2011通信局(站)防雷與接地工程設(shè)計規(guī)范:英文_第5頁](http://file4.renrendoc.com/view/9be77fe037ffa19942a9eac413b14bb9/9be77fe037ffa19942a9eac413b14bb95.gif)
版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報或認(rèn)領(lǐng)
文檔簡介
專用
人人文庫
NATIONALSTANDARD
OFTHEPEOPLESREPUBLICOFCHINA
CodeforDesignofLightningProtectionandEarthing
EngineeringforTelecommunicationBureaus(Stations)
GB50689-2011
ChiefDevelopmentDepartment:MinistryofIndustryandInformationTechnology
ofthePeoplesRepublicofChina
ApprovalDepartment:MinistryofHousingandUrbanRuralDevelopment
-
ofthePeoplesRepublicofChina
ImplementationDate:May1,2012專用
人人文庫
ChinaPlanningPress
Beijing2019
ChineseeditionfirstpublishedinthePeoplesRepublicofChinain2011
EnglisheditionfirstpublishedinthePeoplesRepublicofChinain2019
byChinaPlanningPress
rd
,,專用
3FloorCTowerGuohongBuilding
No.A11,Muxidi-Beili,XichengDistrict
Beijing,100038
PrintedinChinabyFactoryattachedtoBeijingInstituteofGraphicCommunication
?2011byMinistryofHousingandUrban-RuralDevelopmentof
thePeoplesRepublicofChina
Allrightsreserved.Nopartofthispublicationmaybereproducedortransmittedinanyformor
byanymeans人人文庫,graphic,electronic,ormechanical,includingphotocopying,recording,
oranyinformationstorageandretrievalsystems,withoutwrittenpermissionofthepublisher.
Thisbookissoldsubjecttotheconditionthatitshallnot,bywayoftradeorotherwise,belent,
resold,hiredoutorotherwisecirculatedwithoutthepublisherspriorconsentinanyformof
blindingorcoverotherthanthatinwhichthisispublishedandwithoutasimilarcondition
includingthisconditionbeingimposedonthesubsequentpurchaser.
ISBN978-7-5182-1097-8
AnnouncementoftheMinistryofHousingandUrban-Rural
DevelopmentofthePeoplesRepublicofChina
No.981
AnnouncementonPublishingtheNationalStandardof
CodeforDesignofLightningProtectionandEarthing
EngineeringforTelecommunicationBureaus(Stations)
CodeforDesignofLightningProtectionandEarthingEngineeringforTelecommunication
Bureaus(Stations)hasbeenapprovedasanationalstandardwithaserialnumberofGB50689-2011
andshallbeimplementedfromMay1,2012.Articles1.0.6、3.1.1、3.1.2、3.6.8、3.9.1、3.10.3、3.11.2、
3.13.6、3.14.1、4.8.1、5.3.1、5.3.4、6.4.3、6.6.4、7.4.6、9.2.9aremandatoryandmustbeenforcedstrictly.
AuthorizedbytheStandardRatingResearchInstituteoftheMinistryofHousingandUrbanRural
專用-
DevelopmentofthePeoplesRepublicofChina,thisstandardispublishedbyChinaPlanningPress.
MinistryofHousingandUrbanRuralDevelopmentofthePeoplesRepublicofChina
-
April2,2011
人人文庫
Foreword
ThiscodeisformulatedbyChinaInformationTechnologyDesigningandConsultingInstitute
Co.,Ltd.accordingtotherequirementsofDocumentJianBiao〔2008〕No.105issuedbyMinistryof
HousingandUrbanRuralDevelopment"NoticeofPrintingandDistributingtheDevelopmentand
--
RevisionPlan(Secondpitch)ofNationalEngineeringConstructionStandardsin2008".
Duringtheformationofthiscode,theformationteamhasstudiedlotsofthecurrentnationallaws,
regulationsandstandards,maderelevantinvestigations,summarizedyearsofexperienceonthedesign
oflightningprotectionandearthingengineeringforTelecommunicationBureaus(Stations),repeatedly
discussedandmodifiedprovisionsofthiscodeandfinalizedthecodeafterexaminationbasedonsolicit
opinionsfromallsides.
Thiscodecomprises9chaptersand7appendixeswiththemaincontentsasfollows:general
provisions,terms,basicrequirements,thelightningprotectionandearthingofcomprehensive
telecommunicationbuilding,thelightningprotectionandearthingofcabletelecommunicationbureaus
(stations),thelightningprotectionandearthingofmobiletelecommunicationbasestation,the
lightningprotectionandearthingofsmalltelecommunicationstation,thelightningprotectionand
earthingofmicrowaveandsatelliteearstationsandthedesignoflightning專用overvoltageprotectionfor
-
telecommunicationbureaus(stations)andsoon.
Theprovision(s)printedinboldtypeis(are)compulsoryone(ones)andmustbeenforcedstrictly.
MinistryofHousingandUrbanRuralDevelopmentisinchargeoftheadministrationofthiscode
-
andtheexplanationofthecompulsoryprovisions.ChinaInformationTechnologyDesigningand
ConsultingInstituteCo.,Ltd.isresponsiblefortheexplanationofspecifictechnicalcontents.All
relevantorganizationsarekindlyrequestedtosumupandaccumulateyourexperiencesinactual
practicesduringtheprocessofimplementingthiscode.RelevantopinionscanbepostedtoChina
InformationTechnologyDesigningandConsultingInstituteCo.,Ltd.(Address:ZhuYuCommercial
Center,No.5ShouTiNanRD,HaiDianDistrict,Beijing,Postcode:100048)forreferenceofrevision
infuture.
:
ChiefDevelopmentOrganization
ChinaInformationTechnologyDesigningandConsultingInstituteCo.,Ltd
:
ChiefDraftingStaff
人人文庫LiuJikeZhuQingfengChenQiangShiYuhaiWangZhigangQiZheng
NiuNianzeng
:
ChiefExaminationStaff
YangShizhongLinYongshuangGaoJianXuWeijieLiZhi
ZhangDongliangGuoYapingDaiChuanyouGuoWuSunYanling
QiuChuanruiLouJieliangXiaoBoLuZhiJun
Contents
1GeneralProvisions……………(1)
2Terms…………………………(2)
3BasicRequirements……………(6)
3.1GeneralRequirements…………(6)
3.2CompositionofEarthingSystem…………………(6)
3.3EarthElectrode…………………(7)
3.4EarthingConnection……………(8)
3.5MainEarthingConductor………………………(8)
3.6EarthingConductor……………(8)
3.7TheTypesofEquipotentialBonding………………(9)
3.8TheAccessingWaysofVariousCables……………(10)
3.9TheLayoutRequirementsofEarthingConductor……………………(10)
3.10TheProtectionoftheComputerNetworkInterfaceandControlTerminalInterface……(10)
3.11TheEarthingofCentralizedMonitoringSystemandtheInterfaceProtection專用…………(11)
3.12TheLayoutofCablesintheBureau………………(11)
3.13PowerDistributionSystem………………………(11)
3.14TheEarthingofAuxiliaryEquipmentintheEquipmentRoom………(12)
3.15TheLightningProtectionandEarthingofOpticalFiberCable………(12)
4TheLightningProtectionandEarthingofComprehensiveTelecommunicationBuilding……(15)
4.1GeneralRequirements…………(15)
4.2TheTypesofEarthingandBonding………………(16)
4.3TheTypesofInternalEquipotentialBonding………(19)
4.4EarthGrid……………………(19)
4.5TheEarthingoftheCablesEnteringintoBureau……………………(20)
4.6TheEarthingofTelecommunicationEquipment……………………(20)
4.7TheEarthingofPowerSupplySystem……………(23)
4.8TheEarthingofOtherFacilities…………………(23)
4.9TheLightning人人文庫ProtectionDesignofBuilding………(24)
5TheLightningProtectionandEarthingofCableTelecommunicationBureaus(Stations)…(25)
5.1ExchangeBureauandDataBureau………………(25)
5.2AccessNetworkStationandModuleBureau………(26)
5.3BroadbandAccessSites…………(27)
5.4FiberCableRepeaterStation……………………(28)
5.5TheEarthingofDCPowerDistributionSystemforTelecommunicationEquipment……(28)
6TheLightningProtectionandEarthingofMobileTelecommunicationBaseStation…………(29)
6.1GeneralRequirements…………(29)
6.2EarthGrid……………………(29)
·1·
6.3DirectStrokeProtection…………(31)
6.4TheEarthingofAntennaandFeedingCable………(31)
6.5TheLightningProtectionandEarthingofDCRemoteFeedingSystem…………………(32)
6.6TheLightningProtectionofEarthingofGPSAntennasandFeedingCables……………(33)
6.7InternalEquipotentialBonding……………………(33)
6.8TheHandlingofEarthingConnectionandIndoorEarthing……………(34)
6.9TheEarthingofOtherAccessingCables……………(35)
6.10TheEarthingofDCPowerDistributionSystemforTelecommunicationEquipment……(35)
7TheLightningProtectionandEarthingofSmallTelecommunicationStation………………(36)
7.1GeneralRequirements…………(36)
7.2EarthGrid……………………(36)
7.3DirectLightningProtection………………………(37)
7.4Others…………………………(38)
8TheLightningProtectionandEarthingofMicrowaveandSatelliteStations…(39)
8.1TheLightningProtectionandEarthingofMicrowaveStations………(39)
8.2TheLightningProtectionandEarthingofSatelliteStations…………(41)
9TheDesignofLightningOverVoltageProtectionforTelecommunication
-
Bureaus(Stations)……………(42)
9.1GeneralRequirements…………專用(42)
9.2TheApplicationRequirementsofSPD……………(42)
9.3ThePrinciplesofLightningOverVoltageProtectionforthePowerSystemin
-
TelecommunicationBureaus(Stations)……………(43)
9.4TheInstallationRequirementsofPowerSPD………(49)
9.5ThePrinciplesofLightningOverVoltageProtectionDesignforComputerNetworksandSignalCables……(50)
-
AppendixATheStatisticsTablesoftheAverageNumberofThunderstormDaysin
OneYearonMajorCities…………(52)
AppendixBTheNationwideZonedMapoftheAverageNumberofThunderstormDays
inOneYear…………(54)
AppendixCTheRequirementsofSPDProtectionMode………(55)
AppendixDMesh,StarandStarMeshMixedEarthingSystem………………(56)
-
AppendixETheTestofEarthingResistance……………………(57)
AppendixFTheMeasurementofEarthResistivity……………(59)
AppendixGLightning人人文庫ProtectionZones…………(61)
ExplanationofWordinginThisCode……………(63)
ListofQuotedStandards…………(64)
Addition:ExplanationofProvisions………………(65)
·2·
1GeneralProvisions
Thiscodeisformulatedwithaviewtopreventingorreducingthedangeroflightningstrokeat
1.0.1
telecommunicationbureaus(stations),ensuringthesafetyofthepersonnelandalsoensuringthe
telecommunicationequipmentundersafetyandnormalworkconditions.
Thiscodeisapplicabletothedesignoflightningprotectionandearthingengineeringfor
1.0.2
construction,reconstructionandextensionoftelecommunicationbureaus(stations).
Thelightningprotectionandearthingengineeringoftelecommunicationbureaus(stations)shall
1.0.3
beconstructedbasedoncommonearthing,voltagesharingequipotentialandpartitionedprotection,
-
andtheinstallationpositionofSPD(SurgeProtectiveDevice)shallbeplannedreasonablyaccordingto
thetheoryofelectromagneticcompatibilityandtheprincipleoflightningprotectionzones.
Theriskassessmentonlightningstrokeforthedesignoflightningprotectionandearthing
1.0.4
engineeringfortelecommunicationbureaus(stations)shallbebasedonfieldinvestigationdata,
geographicalenvironment,annualthunderstormdaysandtypesofthetelecommunicationbureaus
(stations).
SPDsselectedforlightningovervoltageprotectionprojects專用shallcomplywithtechnical
1.0.5-
requirementsontelecommunicationlightningprotectionproductsoftheMinistryofIndustryand
InformationTechnology.
1.0.6OnlythosequalifiedSPDstestedbyathirdpartytestingdepartmentaccreditedbythestate
mustbeselectedforlightningover-voltageprotectionprojectsoftelecommunicationbureaus
()
stations.
Theannualthunderstormdaysshallbedeterminedaccordingtodataprovidedbythelocal
1.0.7
meteorologicaldepartmentsoftelecommunicationbureaus(stations)ortheprovisionsofAnnexAand
Binthiscode.
Forthedesignoflightningprotectionandearthingengineeringoftelecommunicationbureaus
1.0.8
(stations),notonlytherequirementsstipulatedinthiscodebutalsothoseinthecurrentrelevant
standardsofthenationshallbecompliedwith.
人人文庫
·1·
2Terms
Lightningprotectionzones(LPZ)
2.0.1
Azoneeasilytobeaffectedbylightningstrokeisclassifiedtobetheprotectedzonesinaccordance
withthedifferencesoftheinsideandtheoutsideofbuildings,environmentsoftelecommunication
roomsandprotectedequipmentoftelecommunicationbureaus(stations).Suchprotectedzonesare
calledthelightningprotectionzones.
Thunderstormday
2.0.2
Athunderstormdaymeansonedaywhenmorethanonethundermaybeheard.
Lowkerauniczones
2.0.3
Lowkerauniczonesarethoseareaswheretheaveragenumberofthunderstormdaysinoneyearis
nomorethan25.
Middlekerauniczones
2.0.4
Middlekerauniczonesarethoseareaswheretheaveragenumberofthunderstormdaysinoneyear
iswithinarangeof26-40.
Highkerauniczones專用
2.0.5
Highkerauniczonesarethoseareaswheretheaveragenumberofthunderstormdaysinoneyearis
withinarangeof41-90.
Strongkerauniczones
2.0.6
Strongkerauniczonesarethoseareaswheretheaveragenumberofthunderstormdaysinoneyear
ismorethan90.
Kerauniczones
2.0.7
Thekerauniczonesareclassifiedintolowkerauniczones,middlekerauniczones,highkeraunic
zonesandstrongkerauniczonesaccordingtoaveragenumbersofannualthunderstormdays.
Evaluationoflightningstrikerisk
2.0.8
Itisamethodtohavecomprehensiveevaluationonextentofdamageofthebureaus(stations)due
tolightningstroketotheearthandthendeterminelevelsandclassesofprotection,inaccordancewith
variousfactorsoflightningstroke.
Directlightningflash
2.0.9
Itisaflashdirectly人人文庫attackingbuildingsorlightningprotectionsystems.
Directstrokeprotection
2.0.10
Itisameasuretoprotectbuildings,structures,electricnetworksorelectricalinstallationsfrom
beingattackedbydirectlightningflash.
Airterminalsystem
2.0.11-
Itincludeslightningrods,lightningstrips(conductors)andlightningprotectionnetsthatreceive
lightningstrokedirectly.
Rollingspheremethod
2.0.12
Itisasimplifiedanalysismethodbyapplyingtheelectricgeometrictheorytolightningprotection
analysisofbuildings.
·2·
Downconductorsystem
2.0.13-
Itisametalconductorconnectedtotheairterminalsystemandtheearthterminationsystem.
--
Lightningelectromagneticpulse(LEMP)
2.0.14
Itisanelectromagneticradiationhavingrelationshipwithlightningdischarge.Theelectricfieldand
themagneticfieldgeneratedtherebywillbecoupledtotheelectricorelectronicsystem,thus
destructivesurgecurrentorsurgevoltagewillbeproduced.
Externallightningprotectionsystem
2.0.15
Comprisedofanairterminalsystem,adownconductorsystemandanearthterminationsystem,
---
itismainlyusedasaprotectiondevicetopreventdirectlightningflash.
Soilresistivity
2.0.16
Itisaparameterrepresentingtheconductivityofsoilofwhichthevalueisequaltotheresistance
measuredattwooppositefacesofunitcubeofsoil.TheunitthereofisΩ·m.
Powerfrequencygroundresistance
2.0.17
Itistheresistancebetweentheearthelectrodeandtheremoteearth,whenthepowerfrequency
currentpassesanearthterminationsystem.Itsvalueisequaltothespecificvaluebetweenthevoltageof
-
theearthterminationsystemtotheremoteearthandthecurrentflowingtotheearthviatheearth
-
electrode.
Commonearthing
2.0.18
Itisanearthingmethodwheredifferentearthingmethods專用forvarioustelecommunication
equipmentsattelecommunicationbureaus(stations),includingworkingearthingoftelecommunication
equipment,protectiveearthing,shieldearthing,staticelectricityprotectionearthing,logicgroundof
informationequipment,andetc.arecombinedwiththeprotectiveearthingofmetalcomponentsof
buildingsandlightningprotectionsystemsandSPD,whichshares,togetherwiththelightning
protectionandearthingsystemofthebuildings,thebasicearthelectrodesandexternalearthingsystems.
Earthelectrode
2.0.19
Itisapieceoragroupofconductor(s)closelycontactingwiththesoil(theearth)toprovidethe
electricalconnectionwiththesoil(theearth),forthepurposeofconnectingtotheearth.
Earthingconnection
2.0.20
Earthingconnectionmeanstheconnectinglinebetweentheearthelectrodeandthemainearthing
bar.
Earthingsystem
2.0.21
Itisacomplexsystemcoveringallelectricconnectionsanddevicesforearthingofsystems,
appliancesandequipment人人文庫,whichincludeearthelectrodesintheearth,earthingconductors,andcable
shieldinglayersconnectedtoearthelectrodes,andequipmentshellsconnectedtoearthelectrodesor
exposedmetalcomponents,rebarsorframesofbuildingsandsoon.
Earthgrid
2.0.22
Itisagroupofearthelectrodescomprisedofbareconductorswhichareinterconnectedintheearth,
forthepurposeofprovidingcommonearthforelectricalequipmentsormetalstructures.
Earthterminationsystem
2.0.23-
Itisanaggregationofearthingconductorsandearthelectrodes.
Equipotentialbonding
2.0.24
Connecttheseparateddevicesandvariousconductiveobjectsusingequipotentialbonding
·3·
conductorsorSPDs,soastoreducethepotentialdifferenceamongthemcausedbylightningcurrent.
Equipotentialbondingnetwork
2.0.25
Itisanetworkcomprisedofequipotentialbondingconductorsbywhichvariousexposed
conductivepartsofonesystemareconnected.
Earthingreferencepoint(ERP)
2.0.26
Itistheonlyoneconnectionpointbetweenthecommonearthingsystemandtheequipotential
bondingnetworkofsystem.
Mainearthingconductor
2.0.27
Itmeansthestripcopperbarorthesteelflatusedastheearthingconductor,whichisusuallyused
asthetrunklineoftheearthingsysteminsidethetelecommunicationbureaus(stations),andby
methodsoflaying,itcanbeclassifiedintothehorizontalmainearthingconductor,theverticalmain
earthingconductor,theringmainearthingconductororthebartypemainearthingconductor.
-
Earthingterminal
2.0.28
Itistheconnectionterminalofearthingconductorortheearthingbar.
Earthingbar
2.0.29
Itisconnectedwiththeearthingbus,andusedastherectangularcopperbarforconnection
terminalofvariousearthingconductors.
MainEarthingTerminal(MET)
2.0.30
Itistheearthingbartoconnectvariousearthingconductorswiththe專用earthterminationsystem,and
-
itisalsothefirststageearthingbarofthesystem.
Floorearthingbar(FEB)
2.0.31
Earthingbarsmountedateachfloorinbuildingsareusedforthepurposeofequipotentialbonding
bylocalearthingbars.
Localearthingbar(LEB)
2.0.32
Itistheearthingbarbeingusedinsidetheequipmentroomoftelecommunicationsystemforthe
purposeoflocalequipotentialbonding.
Cableentranceearthingbar(CEEB)
2.0.33
Itisanearthingbartoconnectoutdoorcablesofcableentrancefacilitywithmainearthing
terminalsorringearthelectrodes.
Cableentrancefacility(CEF)
2.0.34
Itisafacilitytoconnectthebuiltinearthingofcablewiththemetalskinforthepurposeof
-
earthing,anditshallbeasclosetotheentranceofoutdoorcableaspossibleaccordingtothepractical
situation.人人文庫
CommonDCreturn(DCC)
2.0.35-
ItisaDCpowersystemwhichallowstheDCreturnconductortohavemultipointconnectionwith
surroundingbondingnetworks.
IsolatedDCreturn(DCI)
2.0.36-
ItisaDCpowersystemwhichallowstheDCreturnconductortohavesinglepointconnectionto
-
BN.
Commonbondingnetwork(CBN)
2.0.37
Itisthemainmethodforconnectionandearthingattelecommunicationbureaus(stations),a
groupofmetalpartswhichareinterconnectedwithspecialintentionorbyaccidentandusedformain
·4·
bondingnetworkofbuildings.
Verticalriser(VR)
2.0.38
Itisagroupofverticalconductorsprovidingalowresistanceengineeringpathbetweenthe
-
telecommunicationequipmentandmainearthingterminals,whichrunthroughverticallytheearthing
trunklinesateachflooroftelecommunicationbureaus(stations).
Lightningovervoltage
2.0.39-
Itisthetransientovervoltageoccurringatsystemports,whichiscausedbylightningdischarge.
Surgeprotectivedevices(SPD)
2.0.40
SPDsaredevicesusedtoprotectvarioustelecommunicationsystemsattelecommunication
bureaus(stations)incaseoflightningovervoltageoroperationovervoltage.
--
VoltagelimitingtypeSPD
2.0.41
Ingeneral,thevoltagelimitingtypeSPDiscomprisedofmetaloxidevaristorsorsemiconductor
protectiondevices,whichmustbeusedintelecommunicationbureaus(stations).
Maximumcontinuousoperatingvoltage
2.0.42
Itistheallowablemaximumalternatingvoltage(rms)ordirectvoltagepermanentlyappliedto
SPD.Thevaluethereofisequaltotheratedvoltage.
Residualvoltage
2.0.43
ItisthevoltagepeakbetweenterminalswhenthedischargecurrentflowsthroughSPD.
ResidualvoltageofSPD專用
2.0.44
ItisthemaximumvoltagepeakmeasuredbetweenSPDterminals,whenthesurgevoltagewith
specificwaveformandamplitudeisapplied.
Nominalstartupvoltage
2.0.45-
Itisthestartingvoltageofmetaloxidevaristor,whenaconstant1mAdirectcurrentisapplied.
Nominaldischargecurrent(In)
2.0.46
ItindicatestheindexofSPDdischargecapability,correspondingtothesurgecurrentof8/20μs
simulatedlightningwave.
Maximumdischargecurrent(Imax)
2.0.47
SPDwillnotbesubstantiallydamaged,andeachline(singlemodule)canpassthroughthe
maximumcurrentpeakwithspe
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 淺灘海域施工方案
- 辦公室裝修終止合同聲明
- 汽車制造液氮配送合同
- 親子游泳館裝修合同管理費(fèi)
- 倉儲物流中心改造拆除協(xié)議
- 北城小學(xué)1年級數(shù)學(xué)試卷
- 銀行柜臺施工方案
- 安師大附中初三數(shù)學(xué)試卷
- 鋁掛片吊頂施工方案
- 司機(jī)不定時工作制合同范例
- 2024年秋季新人教版八年級上冊物理課件 3.5跨學(xué)科實踐:探索廚房中的物態(tài)變化問題
- 山東省威海乳山市(五四制)2023-2024學(xué)年八年級下學(xué)期期末考試化學(xué)試題(解析版)
- 中壓電力線載波通信技術(shù)規(guī)范
- YB∕T 4146-2016 高碳鉻軸承鋼無縫鋼管
- 多圖中華民族共同體概論課件第十三講先鋒隊與中華民族獨立解放(1919-1949)根據(jù)高等教育出版社教材制作
- 第三單元《交流平臺與初試身手》課件語文六年級下冊
- (2024年)TPM培訓(xùn)講義課件
- 高考英語單詞3500(亂序版)
- 《社區(qū)康復(fù)》課件-第五章 脊髓損傷患者的社區(qū)康復(fù)實踐
- 北方、南方戲劇圈的雜劇文檔
- 康復(fù)科st科出科小結(jié)
評論
0/150
提交評論