諾西認證考試題庫_匯總題目_第1頁
諾西認證考試題庫_匯總題目_第2頁
諾西認證考試題庫_匯總題目_第3頁
諾西認證考試題庫_匯總題目_第4頁
諾西認證考試題庫_匯總題目_第5頁
已閱讀5頁,還剩37頁未讀, 繼續(xù)免費閱讀

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認領(lǐng)

文檔簡介

1、 what whole command is useful when conversion database from DBA format to ASC format under Br6.0A dbaem create cmd dbfile.dba -dbinputB dbaem create cmddbfile.dba dbinputC dbaem create cmd -dbinputD dbaem create cmd dbintput D NO 5.1 What file name is can beworking under DBAEM (Br60when DBA conversi

2、on ASC.A db26415.dba.B db25416.dbaC dbfile.ascD dbfile.dbaD NO 5.1What file name is can beworking under DBAEM (Br80when ASC conversion DBA.A cmd27134.ascB cmd28134.ascC cmd27117.ascD cmd28117.ascD NO 5.1Whats kind files will automatic generated in your DBAEM directory when we made conversion command

3、 from ASC format to DBA format wascompletedA snx*.ascB def*.ascC dpm*.ovlD rsp*.asc D NO 5.1 what is DBAEM functionuseful?A modify parameterB build new databaseC database optimizeD database conversionD NO 5.1What command is preferredwhen upgrade database fromBr70 to Br80A converfile -27* -28*B conve

4、rfile 27*.asc28*.ascC converfile -27*.asc 28*.ascD converfile 27* 28*D NO 5.1What command is preferred when upgrade database from Br60 to Br70A converfile -26* -27*B converfile 26*.asc 27*.ascC converfile -26*.asc 27*.ascD converfile 26* 27*D NO 5.1 Whats kind files will automaticgenerated at once i

5、n yourDBAEM directory when wemade conversion commandfrom ASC format to DBA formatwas startingA readme.txtB define.txtC dpm_.ovlD bscinfo.txtD NO 5.1Here I got one message “ERROR > bsc15.asc line 1128- SYNTAX ERROR” pleasegive the reason possible aboutthis alarm.A the parameter set wrongvalueB the

6、 object set wrong nameC the value set out of rangeD the sign set wrong symbolD NO 5.1Here I got one message “UNKNOWN ATTRIBUTE”please give the reason possible about this alarm.A the parameter set wrong valueB the object set wrong nameC the value set out of rangeD the sign set wrong symbol B NO 5.1 H

7、ere I got one message “CREATE LPDLMNAME=BTSM:18/LPDLM:0:RESP="UNSUCCESSFUL_NO_MORE_LAPDPOOL_AVAILABLE" try to give the reasonpossible about this alarm.A parameter errorB symbol errorC naming errorD value out of rangeD NO 5.1Here I got one message “CREATE FHSYNAME=BTSM:12/BTS:0/FHSY: 1:RESP

8、="UNSUCCESSFUL_TR X_FREQ_NOT_FOUND” try to give the reason possible aboutthis alarm.A create btsm have some errorB create bts have some errorC create trx have some errorD create channel have some error C NO 5.1Here I got one message “CREATE BTSNAME=BTSM:15/BTS:0:RESP="INVALID_SVR" try

9、 togive the reason possible aboutthis alarm.A create pcmb have someparameter set errorB create lapdm have someparameter set errorC create btsm have someparameter set errorD create bts have someparameter set errorD NO 5.1HW MSC4 OPC value is set 1001(decimal please give a correct value for match Siem

10、ens database format(hex.A 10-10B 3-233C 1-1D 233-3D YES 4.3YESHW MSC3 SPC value is set3000(decimal please give acorrect value for matchA 8-187B 30-1C 11-184D 184-11D YES 4.3YESwhich parameter need modifyby Siemens side when NT MSCchanges OPC value?A OPCB SPCC OMALD X25B YES 4.3YESwhich parameter nee

11、d modify by Siemens side when HW MSC changes SPC value?A OPCB SPCC OMALD X25A YES 4.3YESwhich parameter need modifyby Siemens side when NT MSCchanges SS7L linkA PCMAB SS7LC SPCD Nothing need modifyB YES 4.3YESTransfer Siemens BSC to HWnew MSC, what parametermust be modified.A LAC and CIB Timer of T3

12、212C Mel IDD OPC and SPCD YES 4.3YESTransfer Siemens BSC to HW NT MSC, can not make MTC, try to give some method of technical for troubleshooting.A reset SS7LB reset SPC and OPCC reset BSC salunameD restart BSC S/W D YES 4.3YESTransfer Siemens BSC toEricsson MSC all SS7L can notworking. Try to give

13、someprobably method of technicalfor troubleshooting.A reset “TSYNC” valueB reset BSC “T3122” valueC reset BSC “MSCV” valueD reset BSC “saluname”valueC YES 4.3YESTransfer Siemens BSC to HWMSC some site can not makeMOC, try to give some methodof technical for solve problem.A reset “IMSIATDT” valueB re

14、set BTSM versionC restart BTS S/WD reset LAC or CI value byMSC sideD YES 4.3YESTransfer Siemens BSC to HW MSC; The RC O-Link can not working normally, try to give some method of technical for solve problem.A restart TRAU S/WB reset MEL IDC reset BSC “NETWTYPE”valueD restart RC server B YES 4.3YEScur

15、rent network configurationas HWMSC1 and HWBSC1、SiemensBSC2 after transfernew SiemensBSC3 toHWMSC1, SiemensBSC3 cannot make handover toHWBSC1 except HWBSC1 toSiemensBSC3, try to givesome advice for solve thisproblem.A SiemensBSC3 OPC andSPC set errorB Never create target cellabout adjacent cell intra

16、HWBSC1C HWMSC1 not createexternal handover data aboutSiemensBSC3D SiemensBSC3 BTScreation data was failC YES 4.3YEStransfer Siemens BSC to NT MSC all MOC and MTC is working now but all incoming handover (inter BSC was reject by unknown reason. What do you think about this case?A NT BSC parameter set

17、 incorrectnessB NT MSC parameter set incorrectnessC Siemens parameter set incorrectnessD Trunk links have problem B YES 4.3YESAfter transfer Siemens BSC toHW MSC the BSC O-Link cannot start. The O-Link route isfirst Siemens BSC PCMA:0-30nuc to HW MSC then from HWMSC nuc to Siemens ownMSC, at last connection to RCserver. please try to give someadvice for solve this problem.A Siemens BSC OMAL or MELID set

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論