版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡介
1、博羅縣文化中心幻影燈光工程施工組織設(shè)計(jì)目錄第一章 編制說明···································1一、 編制依據(jù)·········
2、;····························1二、編制目的····················
3、3;·················1第二章 工程概況·······························&
4、#183;·1第三章 施工總體部署及項(xiàng)目管理機(jī)構(gòu)················2第四章 施工準(zhǔn)備工作···························
5、183;··4第五章 施工專項(xiàng)方案······························4一、 燈光工程施工方案·············
6、83;···············5二、 腳手架工程施工技術(shù)方案······················8三、節(jié)能施工方案········
7、83;························13四、現(xiàn)場施工臨時(shí)用電施工方案·····················18五、安全事故應(yīng)急救
8、援預(yù)案·························25第六章 質(zhì)量、進(jìn)度計(jì)劃保證措施···················30一、 管理組織措施·
9、;······························30二、技術(shù)保證措施··················&
10、#183;··············30三、人力、機(jī)械配備措施···························31四、成品保護(hù)措施····
11、183;····························31五、材料質(zhì)量抽檢監(jiān)控···················
12、183;·········31第七章 施工安全保證措施·························32一、安全生產(chǎn)措施···········
13、183;·····················32二、安全用電措施··························
14、3;······32三、安全防火措施···································33第八章 文明施工措施·····
15、························33第九章 環(huán)境保護(hù)措施························
16、·····33第一章 編制說明1 編制依據(jù)1.1 . 惠州遠(yuǎn)順工程設(shè)計(jì)有限公司提供的設(shè)計(jì)圖紙1.2. 建筑電氣照明裝置施工與驗(yàn)收規(guī)范gb 50617-20101.3 .建筑電氣工程施工質(zhì)量驗(yàn)收規(guī)范gb50303-20021.4 . 電氣裝置工程盤、柜及二次回路結(jié)線施工及驗(yàn)收規(guī)范gb50171-921.5 .建筑工程施工質(zhì)量驗(yàn)收統(tǒng)一標(biāo)準(zhǔn)gb 50300-20011.6 . 民用建筑電氣設(shè)計(jì)規(guī)范jgj 1620081.7.建筑照明設(shè)計(jì)標(biāo)準(zhǔn)gb 50034-20081.8.我公司以往類似工程的施工經(jīng)驗(yàn) 1.9 .博羅縣文體旅游局的相關(guān)要求。1.10.
17、 其它相關(guān)現(xiàn)行的法律、法規(guī)及行業(yè)標(biāo)準(zhǔn)2 . 編制目的目的是針對博羅縣文化中心幻影燈光工程,在施工組織、施工管理、勞動力組織、材料設(shè)備供應(yīng)、施工工藝、進(jìn)度計(jì)劃、質(zhì)量安全措施等方面作的總體規(guī)劃,使工程合理、有效、高質(zhì)量地完成 。第二章 工程概況博羅縣文化中心幻影燈光工程的施工地點(diǎn)位于新建的縣文化中心區(qū)域內(nèi),該工程由影劇院、圖書館、文化館三大部分的室外燈光照明工程組成。燈具類型有金鹵筒燈、金鹵埋地?zé)?、led筒燈、led投光燈、led燈具、led條形燈具、節(jié)能壁燈等,合計(jì)共923套(不含led條形燈具)。第三章 施工總體部署及項(xiàng)目管理機(jī)構(gòu)3.1 總體目標(biāo)工程總體目標(biāo)1質(zhì)量目標(biāo)合格,爭創(chuàng)優(yōu)良工程2工期目
18、標(biāo)計(jì)劃總工期在60日歷天內(nèi)竣工3安全生產(chǎn)目標(biāo)安全生產(chǎn)達(dá)標(biāo)4文明施工目標(biāo)創(chuàng)建文明施工工地施工中嚴(yán)格執(zhí)行建筑工程安全管理?xiàng)l例、建筑施工安全檢查標(biāo)準(zhǔn)jgj59-99以及廣東省建設(shè)工程文明施工若干規(guī)定。3.2 施工總體部署根據(jù)設(shè)計(jì)文件的內(nèi)容、建設(shè)單位的工期、質(zhì)量要求、施工環(huán)境和施工條件,分析本工程的特點(diǎn),制定出切實(shí)可行、科學(xué)的施工組織方案,合理安排人力物力,組織施工作業(yè)。3.3 管理模式實(shí)行項(xiàng)目管理法和目標(biāo)管理責(zé)任制,組成精干的項(xiàng)目領(lǐng)導(dǎo)班子。施工中嚴(yán)格執(zhí)行建設(shè)工程項(xiàng)目管理規(guī)范gb/t503262001,按照工程項(xiàng)目的規(guī)律,組織技術(shù)、質(zhì)安、材料、設(shè)備、勞務(wù)等生產(chǎn)部門,對工程施工進(jìn)行全面、全過程管理,確保
19、工程快速、優(yōu)質(zhì)、安全地完工,為建設(shè)單位提供合格的工程產(chǎn)品。工程質(zhì)量、安全體系設(shè)置如下:職務(wù)姓名年齡發(fā)證機(jī)關(guān)證件號聯(lián)系電話項(xiàng)目經(jīng)理劉華茂35國家建設(shè)部省安全生產(chǎn)監(jiān)管局粵244080918767粵建安b(2011)00009715189519技術(shù)負(fù)責(zé)人朱克波39惠州市人事局粵中職證字第0800102492384號5189519施工員柯木欣49惠州市住房和城鄉(xiāng)規(guī)劃建設(shè)局0023365189519質(zhì)量檢查員黎寶凡26惠州市住房和城鄉(xiāng)規(guī)劃建設(shè)局0023385189519安全員黃建文29惠州市建設(shè)局省安全生產(chǎn)監(jiān)管局粵建安c(2008)001228051895193.4 勞動力組織 根據(jù)施工組織設(shè)計(jì)和進(jìn)度計(jì)
20、劃要求,建立專業(yè)工種施工班組,組織施工作業(yè)人員進(jìn)場,并進(jìn)行施工安全技術(shù)和質(zhì)量技術(shù)交底。3.4.1 勞動力組織計(jì)劃表: 序號工種設(shè)定組數(shù)每組人數(shù)合計(jì)人數(shù)計(jì)劃進(jìn)場時(shí)間備注1電工236根據(jù)業(yè)主要求負(fù)責(zé)電氣、照明安裝工程2架子工133根據(jù)業(yè)主要求負(fù)責(zé)腳手架搭設(shè)以上工種班組人員在施工中根據(jù)施工實(shí)際情況合理調(diào)配。所有特種作業(yè)操作工均持證上崗。3.5 施工機(jī)械設(shè)備計(jì)劃表3.5.1、主要機(jī)械設(shè)備配備表序號機(jī)械設(shè)備名稱規(guī)格型號產(chǎn)地單位數(shù)量1氬弧焊電焊機(jī)臺12沖擊鉆臺33皮卡汽車輛14接地電阻測定儀gxt-80杭州臺25鉗形電流表-600a杭州塊26兆歐表500v杭州塊2第四章 施工準(zhǔn)備工作4.1 技術(shù)準(zhǔn)備 4.
21、1.1 組織施工技術(shù)人員學(xué)習(xí)并熟悉地掌握施工圖紙和有關(guān)的技術(shù)規(guī)范及標(biāo)準(zhǔn)要求;技術(shù)人員將工程情況、施工方案、技術(shù)措施及注意事項(xiàng)等向施工的各工種班組人員作詳細(xì)的技術(shù)交底,嚴(yán)格按設(shè)計(jì)圖紙、施工規(guī)范和施工方案施工。 4.1.2 認(rèn)真審閱施工圖紙,會同設(shè)計(jì)院、建設(shè)單位及監(jiān)理等單位進(jìn)行圖紙會審,做好圖紙會審記錄,作為施工依據(jù)。 4.1.3 加強(qiáng)原材料檢驗(yàn),及時(shí)提供原材料試驗(yàn)報(bào)告和混凝土配合比,做到先檢驗(yàn)合格后才使用。第五章 施工技術(shù)方案因本工程的施工情況特殊,安裝室外燈具的時(shí)候需要在建筑物的外面搭設(shè)腳手架,所以,本節(jié)施工技術(shù)方案的內(nèi)容,除了常規(guī)的闡述電氣部分的施工方案外,還增加了腳手架搭設(shè)的施工技術(shù)方案內(nèi)
22、容一、 室外燈光照明工程施工方案一)、設(shè)備開箱檢查1外包裝及密封良好。2開箱檢查型號、規(guī)格、數(shù)量符合設(shè)計(jì)要求,設(shè)備無損傷附件、備件齊全。3產(chǎn)品技術(shù)文件產(chǎn)品合格證、說明書、出廠試驗(yàn)報(bào)告齊全。4柜(盤)外觀無損傷及變形,油漆完整無損,內(nèi)部電器裝置及元件,絕緣瓷件齊全,無損傷、裂紋等缺陷。二)、光源及燈具的選擇:光源及燈具均應(yīng)具有較好的耐腐蝕性能及良好的電氣絕緣性能。燈具應(yīng)符合燈具通用安全要求及試驗(yàn)(gb7000-86)的有關(guān)要求,燈具的光學(xué)性能應(yīng)滿足設(shè)計(jì)要求。1. led燈具:采用鋁合金材料,進(jìn)行防水處理后安裝在全鋁燈架上,連同變壓器組成一體燈具。2.地埋燈:燈具防護(hù)等級達(dá)到ip67,安裝時(shí)排氣孔
23、要按照生產(chǎn)廠家的說明要求進(jìn)行處理,接線盒應(yīng)安裝防水密封圈,光源應(yīng)盡量放在燈具的底部,燈具表面玻璃溫度應(yīng)控制在65度以下。燈具安裝前應(yīng)按照設(shè)計(jì)要求側(cè)線、定位,安裝好預(yù)埋件。3. led線條燈:燈帶安裝應(yīng)橫平豎直,進(jìn)入燈帶的電源應(yīng)采用軟線保護(hù),燈帶支架應(yīng)分布均勻,支架的顏色與燈帶應(yīng)該統(tǒng),支架應(yīng)與燈帶可靠連接。三)、線管安裝本工程的線管采用pvc-u電工難燃套管及配件,線管的安裝方式主要有三種情況:1).埋地敷設(shè);2)天花吊頂內(nèi)敷設(shè);3)明裝。所有的線管的安裝之前都必須經(jīng)過檢測合格以后,自檢合格并經(jīng)現(xiàn)場監(jiān)理確認(rèn)合格以后才能使用。1.對于埋地敷設(shè)的線管,除了埋設(shè)深度符合施工規(guī)范及設(shè)計(jì)要求之外,還應(yīng)該在
24、線管表面鋪上100mm的細(xì)沙,再鋪上一層紅磚做保護(hù),然后才能回填泥土覆蓋。2.對于在吊頂內(nèi)敷設(shè)的線管,要求嚴(yán)格按照施工規(guī)范及材料供應(yīng)廠家的使用要求進(jìn)行連接,以保證管連接口的施工質(zhì)量,另外,應(yīng)該另外設(shè)置管線的吊裝支點(diǎn),不允許利用天花吊頂頂板作為支承點(diǎn),直接把管放置在吊頂面上。管線的拐彎處,需使用廠家提供的專用彈簧進(jìn)行彎曲,不允許人工在不使用任何輔助機(jī)械的情況下進(jìn)行直接的彎管作業(yè)。3.對于明裝的線管,除了固定間距符合施工規(guī)范要求外,路徑的設(shè)置還應(yīng)該根據(jù)現(xiàn)場具體的情況做到合理,美觀。四)、管內(nèi)穿線1.管內(nèi)的導(dǎo)線嚴(yán)禁有中間接頭,如果不得不出現(xiàn)有接頭,則必須設(shè)置接線盒。2.管內(nèi)穿線的總截面面積不能超過管
25、截面積的40%,另外,管內(nèi)穿線的根數(shù)不能超過施工圖紙電氣設(shè)計(jì)總說明中規(guī)定的根數(shù)。五)、電纜敷設(shè)電纜在安裝前必須測試絕緣電阻達(dá)到良好值時(shí)才能敷設(shè),同時(shí)在敷設(shè)時(shí)必須保證不得有損傷電纜的現(xiàn)象,電纜敷設(shè)后,在有可能受壓的路段采取加保護(hù)管進(jìn)行保護(hù),將保護(hù)管的兩頭加工成喇叭形,防止傷害電纜,電纜需彎曲時(shí)低至全塑型電纜不小于電纜外徑的六倍。電纜安裝應(yīng)橫平豎直安裝牢固、美觀整齊。電纜敷設(shè)在任何場所,嚴(yán)禁重疊、交叉、擠壓等現(xiàn)象。用金屬卡碼固定電纜時(shí),在金屬卡碼處用絕緣膠片墊托加強(qiáng)絕緣,避免傷害電纜,支持卡碼的力度必須受力均勻。六)、配電箱的安裝1.配電箱安裝位置應(yīng)正確,固定牢靠,部件齊全,箱體開孔采用擴(kuò)孔鉆頭開
26、孔,開孔應(yīng)合適,且切口應(yīng)整齊。2.箱內(nèi)外應(yīng)清潔,油漆完整,箱門開關(guān)靈活,回路編號齊全、正確,接線整齊,pe 線安裝明顯、牢固。3.配電箱全部電器及相關(guān)回路安裝完畢后,用500v 搖表對線路進(jìn)行絕緣測試,并做好記錄。4.配電箱的試運(yùn)行(1).配電箱試運(yùn)行前,檢查配電柜內(nèi)有無雜物,安裝是否符合質(zhì)量評定標(biāo)準(zhǔn)。相色、銘牌號是否齊全。(2).送電空載運(yùn)行24 小時(shí),無異常現(xiàn)象,經(jīng)甲方檢查確認(rèn)后,向甲方報(bào)一份存檔。七)、接地保護(hù)、等電位連接、漏電保護(hù)1. 本工程配電系統(tǒng)采用三相五線制,接線時(shí)應(yīng)注意三相平衡。2. 所有電氣設(shè)備及電氣線路在正常情況下不帶電的金屬外殼均應(yīng)按規(guī)程接地。3. 電源引入建筑物進(jìn)線處設(shè)
27、置接地裝置,接地電阻不應(yīng)大于1歐姆,如實(shí)際接地電阻不滿足要求,必須增加接地極。4. 保證燈具配管、接線盒、燈具支架的可靠接地。5. 帶有漏電裝置的回路,要求漏電裝置動作時(shí)間小于0.1秒,動作電流小于30ma。八)、電氣照明安裝質(zhì)量控制安裝完畢,絕緣電阻礙搖測合格后,進(jìn)行通電試運(yùn)轉(zhuǎn)。通電后應(yīng)仔細(xì)檢查和巡視,檢查燈飾的控制是否靈活、準(zhǔn)確;開關(guān)與燈飾控制順序相對應(yīng)。發(fā)現(xiàn)問題立即斷電,迅速查找原因進(jìn)行修復(fù)。使用兆歐表測量絕緣最阻時(shí)應(yīng)注意的問題:1測量時(shí)應(yīng)使兆歐表同被測物的接線正確。為防止接線因絕緣不良造成測量誤差,兆歐表接線柱與被測物之間的連接導(dǎo)線,不得用雙股絕緣或絞線。2測量時(shí)手搖發(fā)電機(jī)要保持勻速,
28、不可過快或過慢,使指針搖擺不定。通常最適宜的速度為120轉(zhuǎn)/分鐘。3測量完畢,須待兆歐表停止轉(zhuǎn)動和被測物接地放電后,方能拆除兆歐表與被測物之間的連接導(dǎo)線。4為便于對測量結(jié)果進(jìn)行分析,在測量時(shí)除應(yīng)記錄好被測物的絕緣電阻外,還應(yīng)盡量記錄對測量有影響的其他因素,如當(dāng)時(shí)的環(huán)境溫度、濕度,所使用的兆歐表電壓級量程范圍和被測物的有關(guān)狀況等。九)、照明器具試運(yùn)行1.電氣照明器具應(yīng)以系統(tǒng)進(jìn)行試電運(yùn)行,系統(tǒng)內(nèi)的全部照明燈具均得開啟,同時(shí)投入運(yùn)行,運(yùn)行時(shí)間為24 小時(shí)。2.全部照明燈具通電運(yùn)行開始后,要及時(shí)用鉗流表、萬用表測量系統(tǒng)的電源電壓及負(fù)荷電流,并做好記錄。試運(yùn)行過程中每隔8 小時(shí)還需測量記錄一次,直到24
29、 小時(shí)運(yùn)行完為止。上述各項(xiàng)測量的數(shù)值要填入試運(yùn)行記錄表內(nèi)。二、 腳手架工程施工技術(shù)方案1 腳手架的部置本工程采用48×3.5mm鋼管,雙排落地式腳手架,內(nèi)排架步距取1.8m,外排架步距取0.9m,橫距1.05m,立桿縱距取1.2m。2 .腳手架的施工2.1、搭設(shè)作業(yè)程序底座布置豎底立桿(角邊起)第一步縱向平桿和橫向平桿按此依次向前伸搭設(shè),直至第一架交圈完成。交圈后,全面檢查構(gòu)架質(zhì)量和地基情況,嚴(yán)格確保設(shè)計(jì)要求和構(gòu)架量設(shè)置連墻桿按第一步搭設(shè)要求和作業(yè)程序搭設(shè)第二步,第三步隨搭設(shè)進(jìn)程及時(shí)裝設(shè)連墻桿件,剪刀撐、卸荷結(jié)構(gòu)裝設(shè)作業(yè)層間橫桿、鋪設(shè)腳手板和裝設(shè)作業(yè)欄桿,擋腳板或圍護(hù)、封閉施工。2.
30、2、腳手架的基底腳手架直接支撐在硬地化地面上,腳墊150cm×150cm的模板。 2.3、掃地桿的搭設(shè)掃地桿設(shè)置為橫向雙排水平桿,應(yīng)貼墊板上安裝,離地30cm左右,安裝要及時(shí)、牢固。2.4、連墻桿搭設(shè)連墻桿的搭設(shè)一邊與預(yù)埋件連接,一邊與內(nèi)排立桿搭設(shè)。即:在現(xiàn)澆混凝土的框架梁、柱留預(yù)埋件,然后用鋼管連接。連墻桿布置一般豎向間距為步距的3倍,橫向間柜為4米。2.5、剪刀撐搭設(shè)為了增強(qiáng)腳手架縱向穩(wěn)定性和整體性,在腳手架豎向傳力結(jié)構(gòu)的外側(cè)應(yīng)沿高度由下而上連續(xù)設(shè)置豎向的剪刀撐,桿與地面夾角在450600范圍內(nèi),剪刀撐應(yīng)沿腳手架全長和全高連續(xù)布設(shè),水平最大間距7m,外排立面水平距離不足3m,可設(shè)
31、“之”字形斜撐。做法見剪刀撐布置圖。2.6、縱向結(jié)構(gòu)2.6.1. 縱向布置采用雙排落地式腳手架,內(nèi)排立桿間距1.2米,外排立桿間距1.2米,內(nèi)外排間距1.05米;2.6.2. 立桿垂直控制為防止立桿偏斜而產(chǎn)生過大的偏心力,應(yīng)嚴(yán)格控制立桿的垂直度:2.7、橫向結(jié)構(gòu)橫向承力結(jié)構(gòu)是由立桿和短橫桿組成的橫向結(jié)構(gòu),是腳手架直接承受和傳遞垂直荷載的部分,腳手架的受力主體,在使用過程中的任何情況下不得拆除貼近立桿的短橫桿;短橫桿垂直距離為1.8米(步高h(yuǎn)),在施工中需留門洞口的地方兩邊必須加人字形斜撐桿,斜撐桿與地面夾角600。2.8、作業(yè)層上料作業(yè)層寬為1.8米,腳手架用18mm厚夾板滿鋪,腳手板鋪設(shè)應(yīng)做
32、到嚴(yán)密、牢固,不得留超過50mm以上的間隙,嚴(yán)禁留長度大于150mm的探頭板。腳手板應(yīng)在下列部位給予固定:(1) 腳手板的兩端和拐角處;(2) 沿板長方向間隔15-20m;(3) 坡道和平臺的兩端;(4) 其它可能發(fā)生滑動和翹起的部位。2.9、施工門洞處理腳手架遇道施工必須預(yù)留通行的門洞時(shí),應(yīng)采取構(gòu)造措施:(1) 門洞上的立桿從門洞上的大橫桿件開始綁扎;(2) 門洞上的內(nèi)外大橫桿用根鋼管加強(qiáng);(3) 腳手架內(nèi)外兩側(cè)在門兩邊設(shè)人字形斜撐,斜撐與地面成600夾角,斜撐應(yīng)與門洞上的立桿和大橫桿綁扎牢固;(4) 門洞上兩側(cè)立桿,用雙鋼管加強(qiáng),做法見門洞加強(qiáng)桿立面圖。2.10、桿件和扣件2.10.1.
33、本工程桿件為48×3.5鋼管,鋼管長以46m為好,嚴(yán)禁使用有嚴(yán)重銹蝕、彎曲、壓扁和有裂縫的鋼管;2.10.2. 扣件使用要有出廠合格證,有脆裂、變形、滑絲的扣件禁止使用,扣件表面應(yīng)進(jìn)行防銹處理,扣件活動部位能靈活轉(zhuǎn)動。2.11、中心節(jié)點(diǎn)在中心節(jié)點(diǎn)處桿件連接應(yīng)盡量靠在一起,以減少偏心矩,貼合面必須嚴(yán)格整齊,搭設(shè)腳手架的扭力矩4060nm.2.12、構(gòu)造措施(1) 立桿要注意桿件的長短搭配使用,立桿接頭必須采用對接桿和對接扣件連接,立桿的接頭與相鄰大橫桿的距離不應(yīng)小于步高的三分之一,相鄰兩立桿的接頭應(yīng)互相錯(cuò)開,相鄰接頭的高度應(yīng)于大于500mm;(2) 大橫桿的長度不宜小于6m,立桿和大橫
34、桿必須用直角扣件扣緊,不得遺漏;上下相鄰的大橫桿應(yīng)錯(cuò)開布置在立桿的里側(cè)和外側(cè),以減少立桿的偏心受荷情況;同一排大橫桿的水平偏差不大于該面腳手架長度的1/300;同一水平內(nèi)的內(nèi)外木橫桿的接頭和上下相距的兩根據(jù)大橫桿的接頭均應(yīng)相互錯(cuò)開,錯(cuò)開距離大于500mm;(3) 小橫桿應(yīng)搭于大橫桿與立桿交叉上,分別用兩種扣件扣緊,在搭設(shè)和使用過程中不得拆除貼近立桿的小橫桿。2.13、搭設(shè)作業(yè)應(yīng)注意事項(xiàng)(1) 嚴(yán)禁48mm和51mm鋼管及其它相應(yīng)扣件混用;(2) 連墻桿和剪刀撐應(yīng)及時(shí)設(shè)置,不得滯后超過2步架;(3) 桿件端部伸出扣件之外的長度不得小于100mm;(4) 在頂排連墻桿件之上的架高不得多于兩步;(5
35、) 剪刀撐的斜桿與基本構(gòu)架結(jié)構(gòu)桿件之間至少有三道連接,其中斜桿的搭接接頭部位于少有一道連接;(6) 必須有良好的放電、避雷裝置;(7) 加強(qiáng)施工人員及施工管理人員的安全技術(shù)培訓(xùn),實(shí)行持證上崗,以保證質(zhì)量、安全措施的要求得地以切實(shí)實(shí)施;2.14、拆卸作業(yè)腳手架的拆除順序:安全網(wǎng)擋腳板護(hù)身欄腳手板小橫桿大橫桿立桿連墻桿、縱向支撐、剪刀撐。拆除腳手架應(yīng)注意以下幾點(diǎn):(1) 連墻桿應(yīng)待其上部桿件拆除完畢才能拆除,嚴(yán)禁出現(xiàn)拆除了多步連墻干后再拆構(gòu)架桿件的危險(xiǎn)作業(yè);(2) 松開扣件,水平桿件應(yīng)隨即撤下,不得松掛要架上;(3) 拆除長桿件時(shí)應(yīng)兩人同時(shí)作業(yè),以免單人作業(yè)時(shí)地閃失事故;(4) 拆下的桿配件應(yīng)吊遠(yuǎn)
36、至地面,不得向下拋擲:(5) 拆除腳手架時(shí)應(yīng)設(shè)專人警戒監(jiān)護(hù),以防傷人;(6) 必須安排泥工班配合隨拆除過程及時(shí)補(bǔ)做外墻面和洞口工作。3.安全防護(hù)措施安全施工在施工方案中已提及,腳手架要有牢固的骨架,可靠的連接,穩(wěn)妥的基底,并按正確的順序架設(shè)和拆卸;除此而外,尚需重視在使用過程中出現(xiàn)的安全防護(hù)問題:3.1. 避免高處墜落物品砸傷地面活動人群。3.2. 在腳手架邊有可能出現(xiàn)人員墜落的地方,設(shè)能承接墜落人和物地安全網(wǎng);3.3. 根據(jù)氣象預(yù)報(bào),在臺風(fēng)到來前,應(yīng)停止腳手架的作業(yè)并進(jìn)行檢查加固,臺風(fēng)過后要對腳手架全面檢查加固;3.4. 在施工期間應(yīng)派專人定期和不定期檢查腳手架的安全情況,做到無事故隱患,發(fā)
37、現(xiàn)有隱患及時(shí)處理;3.5. 在安裝作業(yè)時(shí)應(yīng)做好安全防護(hù),作業(yè)人員必須戴安全帽,系安全帶和工具袋等;3.6. 在首層各通道入口必須搭設(shè)雙層防護(hù)棚,并掛上安全標(biāo)志;3.7. 安全網(wǎng)要用合格的密目式安全網(wǎng);4、文明施工4.1、施工現(xiàn)場安平面圖堆放材料及半成品,堆放整齊;4.2、施工現(xiàn)場要經(jīng)常保持整潔衛(wèi)生,搭設(shè)后應(yīng)當(dāng)班把余下的材料堆放整齊,雜物清理運(yùn)走;4.3、安全立網(wǎng)掛設(shè)整齊、美觀;三、節(jié)能施工方案1.編制依據(jù)1.1 . 惠州遠(yuǎn)順工程設(shè)計(jì)有限公司提供的設(shè)計(jì)圖紙1.2. 建筑節(jié)能工程施工質(zhì)量驗(yàn)收規(guī)范gb50411-20071.3.建筑電氣照明裝置施工與驗(yàn)收規(guī)范gb 50617-20101.4 .建筑電
38、氣工程施工質(zhì)量驗(yàn)收規(guī)范gb50303-20021.5 . 電氣裝置工程盤、柜及二次回路結(jié)線施工及驗(yàn)收規(guī)范gb50171-921.6 .建筑工程施工質(zhì)量驗(yàn)收統(tǒng)一標(biāo)準(zhǔn)gb 50300-20011.7 . 民用建筑電氣設(shè)計(jì)規(guī)范jgj 1620081.8.建筑照明設(shè)計(jì)標(biāo)準(zhǔn)gb 50034-2008 1.9 .博羅縣文體旅游局的相關(guān)要求。1.10. 其它相關(guān)現(xiàn)行的法律、法規(guī)及行業(yè)標(biāo)準(zhǔn)。2.工程概況博羅縣文化中心幻影燈光工程的施工地點(diǎn)位于新建的縣文化中心區(qū)域內(nèi),該工程由影劇院、圖書館、文化館三大部分的室外燈光照明工程組成。燈具類型有金鹵筒燈、金鹵埋地?zé)簟ed筒燈、led投光燈、led燈具、led條形燈具
39、、節(jié)能壁燈等,合計(jì)共923套(不含led條形燈具)。3.節(jié)能的指導(dǎo)思想與目標(biāo)3.1節(jié)能的指導(dǎo)思想建立健全工程質(zhì)量和節(jié)能施工保證體系,使工程質(zhì)量和節(jié)能目標(biāo)自始至終處于受控制狀態(tài)中。充分發(fā)揮公司管理人員及技術(shù)上的優(yōu)勢,應(yīng)用新技術(shù)、新工藝、新設(shè)備、新材料,科學(xué)管理、精心施工,高速、優(yōu)質(zhì)、低耗地完成本項(xiàng)工程。組建有豐富施工經(jīng)驗(yàn)的項(xiàng)目經(jīng)理部,對該工程實(shí)行科學(xué)管理。3.2質(zhì)量與節(jié)能目標(biāo)質(zhì)量目標(biāo):確保博羅文化館燈光幻影工程質(zhì)量達(dá)到合同要求。節(jié)能目標(biāo):確保達(dá)到節(jié)能指標(biāo)合格的工程。4.工程節(jié)能設(shè)計(jì)4.1 本工程的所有燈具皆采用led光源。4.2 供電電纜電線皆采用符合節(jié)能要求型的。5.工程節(jié)能的技術(shù)措施節(jié)能材料
40、須有本市材料準(zhǔn)用證、檢驗(yàn)報(bào)告及出廠合格證,主要材料必須有材料交易證。材料使用前必須經(jīng)復(fù)試合格后方能使用。工程材料的邊角料,余料要盡可能利用。安全防護(hù)材料應(yīng)選用可重復(fù)利用的材料。工地廢料要分類收集。6 電纜材質(zhì)要求:電纜材料在燃燒時(shí)所產(chǎn)生的氣體毒性,應(yīng)符合ga306.122001以及ga1321996材料產(chǎn)煙毒性分級的規(guī)定要求,煙氣毒性(濃度)12.4mg/l。電纜燃燒時(shí)逸出氣體的ph 值和導(dǎo)電率測試按gb/t17650.2-98規(guī)定,ph 值不小于4.3,導(dǎo)電率不大于10s/mm。電纜燃燒時(shí)的阻燃性能應(yīng)能滿足gb/t 18380-2001 規(guī)定的a 類成束電纜垂直燃燒試驗(yàn)。6.我方對施工機(jī)具的
41、節(jié)能要求選擇低能耗的施工機(jī)具。能使用手動機(jī)具的就不用電動工具。電動機(jī)具要及時(shí)維護(hù)保養(yǎng),保證正常使用狀態(tài),避免機(jī)具非正常耗能。禁止機(jī)具非正??蛰d運(yùn)行。禁止使用碘鎢燈做照明。7.低壓動力照明配電系統(tǒng)施工節(jié)能7.1 電氣節(jié)能的措施采用綠色光源、高效節(jié)能型燈具合理選擇電纜截面,減少材料使用,節(jié)約能源。加強(qiáng)對母線壓接頭的質(zhì)量控制,避免由于壓接頭的加工質(zhì)量問題而產(chǎn)生局部接觸電阻增加而造成的發(fā)熱,以減少損耗。低壓配電系統(tǒng)選擇的電纜、電線截面不得低于設(shè)計(jì)值,進(jìn)場時(shí)對其截面和每芯導(dǎo)體電阻值進(jìn)行見證取樣送檢。每芯導(dǎo)體電阻值應(yīng)符合下表的規(guī)定。標(biāo)稱截面(mm2)20時(shí)導(dǎo)體最大電阻(/km)圓筒導(dǎo)體(不鍍金屬)1.51
42、2.12.57.4144.6163.08101.83161.15250.727350.524500.387700.268不同標(biāo)稱截面的電纜、電線每芯導(dǎo)體最大電阻值電纜穿管敷設(shè):管內(nèi)徑不小于電纜外徑的1.5倍。管的彎曲半徑為管外徑的10倍,且不應(yīng)小于所穿電纜的最小彎曲半徑。電纜穿管時(shí),若無彎頭,長度不宜超過50m;有一個(gè)彎頭時(shí)不宜超過20m;有兩個(gè)彎頭時(shí),應(yīng)設(shè)電纜井,電纜中間接線盒應(yīng)放在電纜井內(nèi),接線盒周圍應(yīng)有火災(zāi)延燃設(shè)施。電纜在室內(nèi)埋地、穿墻或穿樓板時(shí),應(yīng)有穿管保護(hù)。水平明敷時(shí)距地應(yīng)不小于2.5m。垂直明敷時(shí),高度1.8m以下部分應(yīng)有防止機(jī)械損傷的措施。7.2 照明配電干線各相負(fù)荷分配規(guī)定三相
43、照明配電干線的各相負(fù)荷宜分配平衡,其最大相負(fù)荷不宜超過三相負(fù)荷平均值的115%,最小負(fù)荷不宜小于三相負(fù)荷平均值的85%。單相負(fù)荷應(yīng)均勻分配到三相上。當(dāng)單相負(fù)荷的總?cè)萘啃∮谟?jì)算范圍內(nèi)三相對稱負(fù)荷總?cè)萘康?5%時(shí),全部按三相對稱負(fù)荷計(jì)算;當(dāng)超過15%時(shí),應(yīng)將單相負(fù)荷換算為等效三相負(fù)荷,再與三相負(fù)荷相加。供電電壓允許偏差:三相供電電壓允許偏差為標(biāo)稱系統(tǒng)電壓的±7%;單相220v為+7%、-10%。公共電網(wǎng)諧波電壓限值:380v的電網(wǎng)標(biāo)稱電壓,電壓總諧波畸變率(thdu)為5%,奇次(125次)諧波含有率為4%,偶次(224次)諧波含有率為2%。諧波電流不應(yīng)超過下表中規(guī)定的允許值。標(biāo)準(zhǔn)電壓(
44、kv)基準(zhǔn)短路容量(mva)諧波次數(shù)及諧波電流允許值(a)23456789101112137862396226441921162813240.3810諧波次數(shù)及諧波電流允許值(a)14151617181920212223242511129.7188.6167.88.97.1146.512諧波電流允許值表三相電壓不平衡度允許值為2%,短時(shí)不得超過4%。四、現(xiàn)場施工臨時(shí)用電施工方案 一、編制依據(jù)1.低壓配電設(shè)計(jì)規(guī)范gb50054-952.建筑工程施工現(xiàn)場供電安全規(guī)范gb50194-933.通用用電設(shè)備配電設(shè)計(jì)規(guī)范gb50055-934.供配電系統(tǒng)設(shè)計(jì)規(guī)范gb50052-955施工現(xiàn)場臨時(shí)用電安全技
45、術(shù)規(guī)范jgj46-2005 二、施工條件1、工程概況博羅縣文化中心幻影燈光工程的施工地點(diǎn)位于新建的縣文化中心區(qū)域內(nèi),該工程由影劇院、圖書館、文化館三大部分的室外燈光照明工程組成。燈具類型有金鹵筒燈、金鹵埋地?zé)簟ed筒燈、led投光燈、led燈具、led條形燈具、節(jié)能壁燈等,合計(jì)共923套(不含led條形燈具) 2、施工現(xiàn)場用電量統(tǒng)計(jì)表:序號機(jī)具名稱型號安裝功率(kw)數(shù)量1氬弧焊電焊機(jī) gw402122沖擊鉆日立0.7510.75三、設(shè)計(jì)內(nèi)容和步驟1、現(xiàn)場勘探及初步設(shè)計(jì):(1)現(xiàn)場采用380v低壓供電,設(shè)一配電總箱,內(nèi)有計(jì)量設(shè)備,采用tn-s系統(tǒng)供電。(2)根據(jù)施工現(xiàn)場用電設(shè)備布置情況,采用
46、導(dǎo)線穿鋼管埋地敷設(shè),布置位置及線路走向參見臨時(shí)配電系統(tǒng)圖及現(xiàn)場平面圖,采用三級配電,兩級防護(hù)。(3)按照jgj46-2005規(guī)定制定施工組織設(shè)計(jì),接地電阻r4。2、確定用電負(fù)荷: (1)、氬弧焊電焊機(jī) kx = 0.30 cos = 0.70 tg = 1.02 pjs = 0.30×2.00 = 0.60 kw (2)、沖擊鉆 kx = 0.30 cos = 0.70 tg = 1.02 pjs = 0.30×2.25 = 0.675kw (3)總的計(jì)算負(fù)荷計(jì)算,總箱同期系數(shù)取 kx = 0.90 總的有功功率 pjs = kx×pjs = 0.90×
47、(0.6+0.675) =1.1475kw 總的無功功率(取值為有功功率的1.05倍) qjs = 1.05×pjs x = 1.2049kva 總的視在功率 sjs = (pjs2+qjs2)1/2 = (1.14752+1.20482)1/2 =1.6638kva 總的計(jì)算電流計(jì)算 ijs = sjs/(1.732×ue) = 1.6638/(1.732×0.38) = 2.531a,3、選擇變壓器: 根據(jù)本工程的實(shí)際情況及計(jì)算結(jié)果,不用選擇變壓器,直接利用業(yè)主指定的配電箱作為一級配電箱,二級、三級配電箱由施工單位負(fù)責(zé)配備。4、選擇總箱的進(jìn)線截面及進(jìn)線開關(guān):(
48、1)選擇導(dǎo)線截面:上面已經(jīng)計(jì)算出總計(jì)算電流ijs = 2.531a,結(jié)合查表,最后選擇的電纜規(guī)格為yjl-3×2.5+2×1.5,其安全載流量為28a,能夠滿足使用要求。(2)選擇二級配電箱開關(guān):dz20-20/3 ,其脫扣器整定電流值為ir = 20a。 (3)選擇三級箱中漏電保護(hù)器:dz20l-15/2 ,漏電動作電流不大于30ma,漏電動作時(shí)間小于0.1s。四、安全用電技術(shù)措施 安全用電技術(shù)措施包括兩個(gè)方向的內(nèi)容:一是安全用電在技術(shù)上所采取的措施;二是為了保證安全用電和供電的可靠性在組織上所采取的各種措施,它包括各種制度的建立、組織管理等一系列內(nèi)容。安全用電措施應(yīng)包括
49、下列內(nèi)容: 1、安全用電技術(shù)措施 (1)、保護(hù)接地 按規(guī)定保護(hù)接地電阻不大于4。 (2)、保護(hù)接零 本工程采用tn-s系統(tǒng)。 tn-s供電系統(tǒng)。它是把工作零線n和專用保護(hù)線pe在供電電源處嚴(yán)格分開的供電系統(tǒng),也稱三相五線制。它的優(yōu)點(diǎn)是專用保護(hù)線上無電流,此線專門承接故障電流,確保其保護(hù)裝置動作。應(yīng)該特別指出,pe線不許斷線。在供電末端應(yīng)將pe線做重復(fù)接地。 施工時(shí)應(yīng)注意:除了總箱處外,其它各處均不得把n線和pe線連接,pe線上不得安裝開關(guān)和熔斷器,也不得把大地兼做pe線且pe線不得通過工作電流。pe線也不得進(jìn)入漏電保護(hù)器且必須由電源進(jìn)線零線重復(fù)接地處或總漏電保護(hù)器電源側(cè)零線處引出,因?yàn)榫€路末端
50、的漏電保護(hù)器動作,會使前級漏電保護(hù)器動作。 (3)、設(shè)置漏電保護(hù)器 施工現(xiàn)場的總配電箱至開關(guān)箱應(yīng)至少設(shè)置兩級漏電保護(hù)器,而且兩級漏電保護(hù)器的額定漏電動作電流和額定漏電動作時(shí)間應(yīng)作合理配合,使之具有分級保護(hù)的功能。 (4)、安全電壓 安全電壓指不戴任何防護(hù)設(shè)備,接觸時(shí)對人體各部位不造成任何損害的電壓。我國國家標(biāo)準(zhǔn)gb3805-83安全電壓中規(guī)定,安全電壓值的等級有42、36、24、12、6v五種。同時(shí)還規(guī)定:當(dāng)電氣設(shè)備采用了超過24v時(shí),必須采取防直接接觸帶電體的保護(hù)措施。 對下列特殊場所應(yīng)使用安全電壓照明器。 1)隧道、人防工程、有高溫、導(dǎo)電灰塵或燈具離地面高度低于2.5m等場所的照明,電源電
51、壓應(yīng)不大于36v。 2)在潮濕和易觸及帶電體場所的照明電源電壓不得大于24v。 (5)、電氣設(shè)備的設(shè)置應(yīng)符合下列要求 1)配電系統(tǒng)應(yīng)設(shè)置配電柜或總配電箱、分配電箱、開關(guān)箱,實(shí)行三級配電。配電系統(tǒng)應(yīng)采用三相負(fù)荷平衡。220v或380v單相用電設(shè)備接入220/380v三相四線系統(tǒng);當(dāng)單相照明線路電流大于30a時(shí),應(yīng)采用220/380v三相四線制供電。 2)動力配電箱與照明配電箱宜分別設(shè)置,如合置在同一配電箱內(nèi),動力和照明線路應(yīng)分路設(shè)置,照明線路接線宜接在動力開關(guān)的上側(cè)。 3)總配電箱應(yīng)設(shè)置在靠近電源區(qū)域,分配電箱應(yīng)設(shè)置在用電設(shè)備或負(fù)荷相對集中的區(qū)域,分配電箱與開關(guān)箱的距離不得超過30m,開關(guān)箱與其
52、控制的固定式用電設(shè)備的水平距離不應(yīng)超過3m。 4)每臺用電設(shè)備必須有各自專用的開關(guān)箱,禁止用同一個(gè)開關(guān)箱直接控制二臺及二臺以上用電設(shè)備(含插座)。 (6)、電工及用電人員必須符合以下要求: 1)電工必須經(jīng)過按國家現(xiàn)行標(biāo)準(zhǔn)考核合格后,持證上崗工作;其他用電人員必須通過相關(guān)安全教育培訓(xùn)和技術(shù)交底,考核合格后方可上崗工作。 暫時(shí)停用設(shè)備的開關(guān)箱必須分?jǐn)嚯娫锤綦x開關(guān),并應(yīng)關(guān)門上鎖;移動電氣設(shè)備時(shí),必須經(jīng)電工切斷電源并做妥善處理后進(jìn)行。(7)、電氣設(shè)備的使用與維護(hù) 1)配電箱、開關(guān)箱應(yīng)有名稱、用途、分路標(biāo)記及系統(tǒng)接線圖。 2)配電箱、開關(guān)箱箱門應(yīng)配鎖,并應(yīng)由專業(yè)負(fù)責(zé)。 3)配電箱、開關(guān)箱應(yīng)每月進(jìn)行一次檢
53、查和維修。檢查、維修人員必須是專業(yè)電工。檢查、維修時(shí)必須按規(guī)定穿、戴絕緣鞋、手套,必須使用電工絕緣工具,并應(yīng)做檢查、維修工作記錄。 (8)、施工現(xiàn)場的電纜線路 1)電纜中必須包含全部工作芯線和作用保護(hù)零線或保護(hù)線的芯線。需要三相四線制配電的電纜線路必須采用五芯電纜。五芯電纜必須包括含淡藍(lán)、綠/黃二種顏色絕緣芯線。淡藍(lán)色芯線必須用作n線;綠/黃雙色芯線必須用作pe線,嚴(yán)禁混用。 2)電纜線路應(yīng)采用埋地或架空敷設(shè),嚴(yán)禁沿地面明設(shè),并應(yīng)避免機(jī)械損傷和介質(zhì)腐蝕。埋地電纜路徑應(yīng)設(shè)方位標(biāo)志。 3)電纜類型應(yīng)更具敷設(shè)方式、環(huán)境條件等選擇。埋地敷設(shè)應(yīng)采用鎧裝電纜;當(dāng)選用無鎧裝電纜時(shí),應(yīng)能放水、防腐。架空敷設(shè)應(yīng)
54、采用無鎧裝電纜。 2、安全用電組織措施 建立臨時(shí)用電施工組織設(shè)計(jì)和安全用電技術(shù)措施的編制、審批制度,并建立相應(yīng)的技術(shù)檔案。 五、安全用電防火措施 1、施工現(xiàn)場發(fā)生火災(zāi)的主要原因 (1)、電氣線路過負(fù)荷引起火災(zāi); (2)、線路短路引起火災(zāi);(3)、接觸電阻過大引起火災(zāi);(4)、電熱設(shè)備、照燈具使用不當(dāng)引起火災(zāi) (5)、電弧、電火花引起火災(zāi)。 2、預(yù)防電氣火災(zāi)的措施 針對電氣火災(zāi)發(fā)生的原因,施工組織設(shè)計(jì)中要制定出有效的預(yù)防措施。 (1)、施工組織設(shè)計(jì)時(shí)要根據(jù)電氣設(shè)備的用電量正確選擇導(dǎo)線截面,從理論上杜絕線路過負(fù)荷使用,保護(hù)裝置要認(rèn)真選擇,當(dāng)線路上出現(xiàn)長期過負(fù)荷時(shí),能在規(guī)定時(shí)間內(nèi)動作保護(hù)線路。 (2
55、)、導(dǎo)線架空敷設(shè)時(shí)其安全間距必須滿足規(guī)范要求,當(dāng)配電線路采用熔斷器作短路保護(hù)時(shí),熔體額定電流一定要小于電纜或穿管絕緣導(dǎo)線允許載流量的2.5倍,或明敷絕緣導(dǎo)線允許載流量的1.5倍。經(jīng)常教育用電人員正確執(zhí)行安全操作規(guī)程,避免作業(yè)不當(dāng)造成火災(zāi)。 (3)、電氣操作人員要認(rèn)真執(zhí)行規(guī)范,正確連接導(dǎo)線,接線柱要壓牢、壓實(shí)。各種開關(guān)觸頭要壓接牢固。銅鋁連接時(shí)要有過渡端子,多股導(dǎo)線要用端子或涮錫后再與設(shè)備安裝,以防加大電阻引起火災(zāi)。 (4)、使用焊機(jī)時(shí)要執(zhí)行用火證制度,并有人監(jiān)護(hù),施焊周圍不能存在易燃物體,并備齊防火設(shè)備。電焊機(jī)要放在通風(fēng)良好的地方。 (5)、施工現(xiàn)場的高大設(shè)備和有可能產(chǎn)生靜電的電氣設(shè)備要做好防
56、雷接地和防靜電接地,以免雷電及靜電火花引起火災(zāi)。 (6)、配電箱、開關(guān)箱內(nèi)嚴(yán)禁存放雜物及易燃物體,并派專人負(fù)責(zé)定期清掃。 (7)、施工現(xiàn)場應(yīng)建立防火檢查制度,強(qiáng)化電氣防火領(lǐng)導(dǎo)體制,建立電氣防火隊(duì)伍。 (8)、施工現(xiàn)場一旦發(fā)生電氣火災(zāi)時(shí),撲滅電氣火災(zāi)應(yīng)注意以下事項(xiàng): 迅速切斷電源,以免事態(tài)擴(kuò)大。切斷電源時(shí)應(yīng)戴絕緣手套,使用有絕緣柄的工具。當(dāng)火場離開關(guān)較遠(yuǎn)需剪斷電線時(shí),火線和零線應(yīng)分開錯(cuò)位剪斷,以免在鉗口處造成短路,并防止電源線掉在地上造成短路使人員觸電。 (9)、當(dāng)電源線因其它原因不能及時(shí)切斷時(shí),一方面派人去供電端拉閘,另一方面滅火時(shí),人體的各部位與帶電體應(yīng)保持一定充分距離,必須穿戴絕緣用品。
57、(10)、撲滅電氣火災(zāi)時(shí)要用絕緣性能好的滅火劑如干粉滅火機(jī),二氧化碳滅火器,1211滅火器或干燥砂子。嚴(yán)禁使用導(dǎo)電滅火劑進(jìn)行撲救。五、施工現(xiàn)場安全事故應(yīng)急預(yù)案一)、物體打擊事故應(yīng)急預(yù)案1、應(yīng)急準(zhǔn)備1.1、組織機(jī)構(gòu)及職責(zé): a、項(xiàng)目部物體打擊事故應(yīng)急領(lǐng)導(dǎo)小組 組長:項(xiàng)目經(jīng)理 組員:施工員、安全員、各班組長、技術(shù)員、質(zhì)檢員、值勤人員 b、物體打擊事故應(yīng)急處置領(lǐng)導(dǎo)小組負(fù)責(zé)對項(xiàng)目突發(fā)物體打擊事故的應(yīng)急處理。1.2、培訓(xùn)和演練 &
58、#160; a、項(xiàng)目部安全員負(fù)責(zé)主持、組織全機(jī)關(guān)每年進(jìn)行一次按物體打擊事故“應(yīng)急響應(yīng)”的要求進(jìn)行模擬演練。各組員按其職責(zé)分工,協(xié)調(diào)配合完成演練。演練結(jié)束后由組長組織對“應(yīng)急響應(yīng)”的有效性進(jìn)行評價(jià),必要時(shí)對“應(yīng)急響應(yīng)”的要求進(jìn)行調(diào)整或更新。演練、評價(jià)和更新的記錄應(yīng)予以保持。 b、施工管理部負(fù)責(zé)對相關(guān)人員每年進(jìn)行一次培訓(xùn)。1.3、應(yīng)急物資的準(zhǔn)備、維護(hù)、保養(yǎng) a、應(yīng)急物資的準(zhǔn)備:簡易單架、跌打損傷藥品、包扎紗布。 b、各種應(yīng)急物資要配備齊全并加強(qiáng)日常管理。2、應(yīng)急響應(yīng) 2.1、防物體打擊事故發(fā)生,項(xiàng)目部成立義務(wù)小組,由項(xiàng)目經(jīng)理擔(dān)任組長,施工員及安全員,各班組長為組員,主要負(fù)責(zé)緊急事故發(fā)生
59、時(shí)有條不紊的進(jìn)行搶救或處理,其他人員協(xié)助施工員做相關(guān)輔助工作。 2.2、發(fā)生物體打擊事故后,由項(xiàng)目經(jīng)理負(fù)責(zé)現(xiàn)場總指揮,發(fā)現(xiàn)事故發(fā)生人員首先高聲呼喊,通知現(xiàn)場安全員,由安全員打事故搶救,電話“120”,向上級有關(guān)部門或醫(yī)院打電話搶救,同時(shí)通知生產(chǎn)負(fù)責(zé)人組織緊急應(yīng)變小組進(jìn)行可行的應(yīng)急搶救,如現(xiàn)場包扎、止血等措施。防止受傷人員流血過多造成死亡事故發(fā)生。預(yù)先成立的應(yīng)急小組人員分工,各負(fù)其責(zé),重傷人員由水、電工協(xié)助送外搶救工作,值勤門衛(wèi)在大門口迎接來救護(hù)的車輛,有程序的處理事故、事件,最大限度的減少人員和財(cái)產(chǎn)損失。如事故嚴(yán)重,應(yīng)立即報(bào)告公司工程總
60、部,并請求啟動公司級應(yīng)急救援預(yù)案。 二)、機(jī)械傷害事故應(yīng)急預(yù)案1、應(yīng)急準(zhǔn)備1.1、組織機(jī)構(gòu)及職責(zé) a、項(xiàng)目部機(jī)械傷害事故應(yīng)急領(lǐng)導(dǎo)小組 組長:項(xiàng)目經(jīng)理 組員:施工員、安全員、各班組長、技術(shù)員、質(zhì)檢員、值勤人員 b、機(jī)械傷害事故應(yīng)急處置領(lǐng)導(dǎo)小組負(fù)責(zé)對項(xiàng)目突發(fā)機(jī)械傷害事故的應(yīng)急處理。1.2、培訓(xùn)和演練 a、項(xiàng)目部安全員負(fù)責(zé)主持、組織全機(jī)關(guān)每年進(jìn)行一次按機(jī)械傷害事故“應(yīng)急響應(yīng)”的要求進(jìn)行模擬演練。各組員按其職責(zé)分工,協(xié)調(diào)配合完成演練,演練結(jié)束后由組長組織對“應(yīng)急響應(yīng)
61、”的有效性進(jìn)行評價(jià),必要時(shí)對“應(yīng)急響應(yīng)”的要求進(jìn)行調(diào)整或更新。演練、評價(jià)和更新的記錄應(yīng)予以保持 b、項(xiàng)目管理部負(fù)責(zé)對相關(guān)人員每年進(jìn)行一次培訓(xùn)。1.3、應(yīng)急物資的準(zhǔn)備、維護(hù)、保養(yǎng) a、應(yīng)急物資的準(zhǔn)備:簡易單架、跌打損傷藥品、包扎紗布。 b、各種應(yīng)急物資要配備齊全并加強(qiáng)日常管理。2、應(yīng)急響應(yīng) 2.1、防機(jī)械傷害事故發(fā)生,項(xiàng)目部成立義務(wù)小組,由項(xiàng)目經(jīng)理擔(dān)任組長,施工員及安全員,各班組長為組員,主要負(fù)責(zé)緊急事故發(fā)生時(shí)有條有理的進(jìn)行搶救或處理,其他人員做協(xié)助工作。 2.2、發(fā)生機(jī)械傷害事故后,由項(xiàng)目經(jīng)理負(fù)責(zé)現(xiàn)場總
62、指揮,發(fā)現(xiàn)事故發(fā)生人員首先高聲呼喊,通知現(xiàn)場安全員,由安全員打事故搶救電話“120”,向上級有關(guān)部門或醫(yī)院打電話搶救,同時(shí)通知生產(chǎn)負(fù)責(zé)人組織緊急應(yīng)變小組進(jìn)行可行的應(yīng)急搶救,如現(xiàn)場包扎、止血等措施。防止受傷人員流血過多造成死亡事故發(fā)生。預(yù)先成立的應(yīng)急小組人員分工,各負(fù)其責(zé),重傷人員由水、電工協(xié)助送外搶救工作,值勤門衛(wèi)在大門口迎接來救護(hù)的車輛,有程序的處理事故、事件最大限度的減少人員和財(cái)產(chǎn)損失。如事故嚴(yán)重,應(yīng)立即報(bào)告公司工程總部,并請求啟動公司級應(yīng)急救援預(yù)案。 三)、觸電事故應(yīng)急預(yù)案1、應(yīng)急準(zhǔn)備1.1、組織機(jī)構(gòu)及職責(zé) a、項(xiàng)目部觸電事故應(yīng)急領(lǐng)導(dǎo)小組 &
63、#160;組長:項(xiàng)目經(jīng)理 組員:施工員、安全員、各專業(yè)工長、技術(shù)員、質(zhì)檢員、值勤人員 b、觸電事故應(yīng)急處置領(lǐng)導(dǎo)小組負(fù)責(zé)對項(xiàng)目突發(fā)觸電事故的應(yīng)急處理。1.2、培訓(xùn)和演練 a、項(xiàng)目部安全員負(fù)責(zé)主持、組織全機(jī)關(guān)每年進(jìn)行一次按觸電事故“應(yīng)急響應(yīng)”的要求進(jìn)行模擬演練。各組員按其職責(zé)分工,協(xié)調(diào)配合完成演練。演練結(jié)束后由組長組織對“應(yīng)急響應(yīng)”的有效性進(jìn)行評價(jià),必要時(shí)對“應(yīng)急響應(yīng)”的要求進(jìn)行調(diào)整或更新。演練、評價(jià)和更新的記錄應(yīng)予以保持。 b、項(xiàng)目管理部負(fù)責(zé)對相關(guān)人員每年進(jìn)
64、行一次培訓(xùn)。1.3、應(yīng)急物資的準(zhǔn)備、維護(hù)、保養(yǎng) a、應(yīng)急物資的準(zhǔn)備:簡易單架。 b、應(yīng)急物資要配備齊全并加強(qiáng)日常管理。2、應(yīng)急響應(yīng) 2.1、脫離電源對癥搶救 當(dāng)發(fā)生人身觸電事故時(shí),首先使觸電者脫離電源。迅速急救,關(guān)鍵是“快” 2.2、對于低壓觸電事故,可采用下列方法使觸電者脫離電源 a、如果觸電地點(diǎn)附近有電源開關(guān)或插銷,可立即拉開電源開關(guān)或拔下電源插頭,以切斷電源。 b、可用有絕
65、緣手柄的電工鉗、干燥木柄的斧頭、干燥木把的鐵鍬等切斷電源線。也可采用干燥木板等絕緣物插入觸電者身下,以隔離電源。 c、當(dāng)電線搭在觸電者身上或被壓在身下時(shí),也可用干燥的衣服、手套、繩索、木板、木棒等絕緣物為工具,拉開提高或挑開電線,使觸電者脫離電源。切不可直接去拉觸電者。2.3、對于高壓觸電事故,可采用下列方法使觸電者脫離電源 a、立即通知有關(guān)部門停電。 b、帶上絕緣手套,穿上絕緣鞋,用相應(yīng)電壓等級的絕緣工具按順序拉開開關(guān)。 c、用高壓絕緣桿挑開觸電者身上的電線。 &
66、#160;2.4、觸電者如果在高空作業(yè)時(shí)觸電,斷開電源時(shí),要防止觸電者摔下來造成二次傷害 a、如果觸電者傷勢不重,神志清醒,但有些心慌,四肢麻木,全身無力或者觸電者曾一度昏迷,但已清醒過來,應(yīng)使觸電者安靜休息,不要走動,并對其嚴(yán)密觀察。 b、如故觸電者傷勢較重,已失去知覺,但心臟跳動和呼吸還存在,應(yīng)將觸電者抬至空氣暢通處,解開衣服,讓觸電者平直仰臥,并用軟衣服墊在身下,使其頭部比肩稍低,以免妨礙呼吸,如天氣寒冷要注意保溫,并迅速送往醫(yī)院。如果發(fā)現(xiàn)觸電者呼吸困難,發(fā)生痙攣,應(yīng)立即準(zhǔn)備對心臟停止跳動或者呼吸停止后的搶救。 c、如果觸電者傷勢較重,呼吸停止或心臟跳動停止或二者都已停止,應(yīng)立即進(jìn)行口對口人工呼吸法及胸外心臟擠壓法進(jìn)行搶救,并送往醫(yī)院。在送往醫(yī)院的途中,不應(yīng)停止搶救,許多觸電者就是在送往醫(yī)院途中死亡的。 d、人觸電后會出現(xiàn)神經(jīng)麻痹、呼吸中斷、心臟停止跳動、呈現(xiàn)昏迷不醒狀態(tài),通常都是假死,萬萬不可當(dāng)作“死人”草率從事。 e、對于觸電者,特別高空墜落的觸電者,要特別注意搬運(yùn)問題,很多觸電者,除電傷外還有摔傷,搬運(yùn)不當(dāng),如折斷的肋骨扎入心臟等,可造成死亡。 四)、高空墜落事故應(yīng)急預(yù)案1、應(yīng)急準(zhǔn)備1.1、組織機(jī)構(gòu)及職責(zé) a、項(xiàng)目部高處墜落事故應(yīng)急領(lǐng)導(dǎo)小組
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 北京市教育合同糾紛仲裁收費(fèi)標(biāo)準(zhǔn)
- 金鷹頒獎禮儀培訓(xùn)方案
- 滅火與應(yīng)急疏散培訓(xùn)
- 重慶市第九十四初級中學(xué)校2024-2025學(xué)年高二上學(xué)期期中考試政治試題(含解析)
- 19 C光的干涉 提升版2025新課改-高中物理-選修第1冊(21講)
- 海洋水文氣象自動觀測系統(tǒng)相關(guān)項(xiàng)目投資計(jì)劃書范本
- 肝功能評定及肝功能儲備課件
- 規(guī)劃設(shè)計(jì)類答辯
- 碘缺乏病診治指南
- 跨境物流行業(yè)發(fā)展趨勢報(bào)告
- 2023年全國社會保障基金理事會招聘筆試真題
- 2024年城市公共綠地養(yǎng)護(hù)及保潔合同
- 2024年光纜敷設(shè)及維護(hù)合同
- 2024-2025學(xué)年高中地理第四章自然環(huán)境對人類活動的影響2全球氣候變化對人類活動的影響達(dá)標(biāo)訓(xùn)練含解析中圖版必修1
- 化工廠設(shè)備安裝施工方案
- 疫情期間學(xué)生德育工作總結(jié)
- (新課標(biāo)新教材)2024秋新人教版數(shù)學(xué)小學(xué)一年級上冊數(shù)學(xué)第 四單元第1課時(shí)《10的再認(rèn)識》說課稿
- 中級養(yǎng)老護(hù)理練習(xí)題庫(含參考答案)
- GB/T 19964-2024光伏發(fā)電站接入電力系統(tǒng)技術(shù)規(guī)定
- 巴金《家》簡介課件
- 3.1《讓小車運(yùn)動起來》優(yōu)質(zhì)課件
評論
0/150
提交評論