版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領
文檔簡介
DSO7004BSeriesDigitalStorageOscilloscopeUserManual(Version1.1)ContentsDSO7004BSeriesDigitalStorageOscilloscopeUserManualPAGEii目錄ContentsContents iCopyrightDeclaration iiiChapter1 SafetyTips 11.1 GeneralSafetySummary 11.2 SafetyTermsandSymbols 21.3 TermsonProduct 21.4 SymbolsonProduct 21.5 ProductScrapping 2Chapter2 Overview 32.1 BriefIntroductiontoDSO7004BSeries 3Chapter3 GettingStartedGuide 43.1 Installation 43.1.1 PowerSupply 43.1.2 PowerCord 43.2 FunctionalCheck 43.2.1 Powerontheoscilloscope 43.2.2 Connecttheoscilloscope 43.2.3 Observethewaveform 53.3 ProbeExamination 53.3.1 Safety 53.3.2 UseofProbeCheckWizard 63.4 ManualProbeCompensation 63.5 ProbeAttenuationSetting 73.6 SelfCalibration 7Chapter4 MainFeatureDescription 84.1 OscilloscopeSetup 84.2 Trigger 84.3 DataAcquisition 104.4 WaveformScalingandPositioning 104.5 WaveformMeasurement 11Chapter5 BasicOperation 135.1 DisplayArea 135.1.1 XYFormat 155.2 HorizontalControls 155.2.1 ScanModeDisplay(RollMode) 175.3 VerticalControls 175.3.1 MathFFT 195.4 TriggerControls 255.5 MenuandOptionButtons 315.5.1 MEASURE 315.5.2 ACQUIRE 335.5.3 UTILITY 355.5.4 CURSOR 365.5.5 HELP 365.5.6 SAVE/RECALL 375.5.7 DISPLAY 395.6 FastActionButtons 395.6.1 AUTOSET 405.6.2 Help 415.6.3 DefaultSetup 415.7 Multi-functionalKnobsandButtons 435.8 SignalConnectors 43Chapter6 ApplicationExamples 456.1 Example1:TakingSimpleMeasurements 456.2 Example2:TakingCursorMeasurements 476.3 Example3:AnalyzingInputSignalstoEliminateRandomNoise 506.4 Example4:CapturingSingle-shotSignal 516.5 Example5:UsingX-YMode 526.6 Example6:TriggeringonPulseWidth 536.7 Example7:TriggeringonVideoSignal 546.8 Example8:UsingSlopeTriggertoCaptureParticularSlopeSignal 566.9 Example9:UsingOvertimeTriggertoMeasureLongPulseSignal 576.10 Example10:UsingMathFunctionstoAnalyzeWaveforms 586.11 Example11:MeasuringDataPropagationDelay 59Chapter7 Troubleshooting 617.1 ProblemSettlement 61Chapter8 Specifications 628.1 TechnicalSpecifications 628.2 Accessories 68Chapter9 ServicesandSupport 69Chapter10 GeneralCareandCleaning 7010.1 GeneralCare 7010.2 Cleaning 70AppendixAHarmfulandPoisonousSubstancesorElements 71CopyrightDeclarationCopyrightDeclarationAllrightsreserved;nopartofthisdocumentmaybereproducedortransmittedinanyformorbyanymeans,electronicormechanical,withoutpriorwrittenpermissionfromHantekTechnologiesCo.,Ltd(hereinafterreferredtoas‘Hantek’).Hantekreservesallrightstomodifythisdocumentwithoutpriornotice.PleasecontactHantekforthelatestversionofthisdocumentbeforeplacinganorder.Hantekhasmadeeveryefforttoensuretheaccuracyofthisdocumentbutdoesnotguaranteetheabsenceoferrors.Moreover,Hantekassumesnoresponsibilityinobtainingpermissionandauthorizationofanythirdpartypatent,copyrightorproductinvolvedinrelationtotheuseofthisdocument.SafetyTipsSafetyTipsGeneralSafetySummaryReadthefollowingsafetyprecautionstoavoidinjuryandpreventdamagetothisproductoranyproductsconnectedtoit.Toevadepotentialhazards,usethisproductonlyasspecified.Onlyqualifiedpersonnelshouldperformmaintenance.Avoidfireorpersonalinjury.Usesuitablepowercord.Useonlythepowercordspecifiedforthisproductandcertifiedforthecountryofuse.Connectanddisconnectproperly.Connectaprobewiththeoscilloscopebeforeitisconnectedtomeasuredcircuits;disconnecttheprobefromtheoscilloscopeafteritisdisconnectedfrommeasuredcircuits.Groundtheproduct.Thisproductisgroundedthroughthegroundingconductorofthepowercord.Toavoidelectricshock,thegroundingconductormustbeconnectedtoearthground.Beforemakingconnectionstotheinputoroutputterminalsoftheproduct,ensurethattheproductisproperlygrounded.Connecttheprobeinarightway.Theprobegroundleadisatgroundpotential.Donotconnectthegroundleadtoanelevatedvoltage.Checkallterminalratings.Toavoidfireorshockhazard,checkallratingsandmarkingsontheproduct.Refertotheproductmanualfordetailedinformationaboutratingsbeforemakingconnectionstotheproduct.Donotoperatewithoutcovers.Donotoperatethisproductwithcoversorpanelsremoved.Avoidexposedcircuitry.Donottouchexposedconnectionsandcomponentswhenpowerispresent.Donotoperatewithsuspectedfailures.Ifyoususpectthereisdamagetothisproduct,haveitinspectedbyqualifiedservicepersonnel.Assuregoodventilation.Donotoperateinwet/dampenvironments.Donotoperateinanexplosiveatmosphere.Keepproductsurfacescleananddry.SafetyTermsandSymbolsThefollowingtermsmayappearinthismanual:WARNING.Warningstatementspointoutconditionsorpracticesthatcouldresultininjuryorlossoflife.CAUTION.Cautionstatementsidentifyconditionsorpracticesthatcouldresultindamagetothisproductorotherproperty.TermsonProductThefollowingtermsmayappearontheproduct:DANGERindicatesaninjuryhazardimmediatelyaccessibleasyoureadthemarking.WARNINGindicatesaninjuryhazardnotimmediatelyaccessibleasyoureadthemarking.CAUTIONindicatesapossiblehazardtothisproductorotherproperty.SymbolsonProductThefollowingsymbolsmayappearontheproduct:ProtecProtectiveGround(Earth)TerminalMeasurementGroundTerminalCAUTIONRefertoManualMeasurementInputTerminalMainsDisconnectedMainsDisconnectedOFF(Power)MainsConnectedON(Power)HighVoltageProductScrappingDeviceRecyclingWeneedextractandutilizenaturalresourcestoproducethisdevice.Ifyoudonotreclaimthedeviceinaproperway,somesubstancesitcontainsmaybecomeharmfulorpoisonoustoenvironmentsorhumanbodies.Toavoidthembeingreleasedoutsideandtominimizethewasteofnaturalresources,wesuggestyoureasonablycallbackthisdevicetoensureproperrecoveryandrecyclingofmostmaterialswithinit.OverviewOverviewBriefIntroductiontoDSO7004BSeriesModelChannelsBandwidthSampleRateLCDDSO7084B480MHz2GS/s7inchcolorDSO7104B4100MHz2GS/s7inchcolorDSO7204B4200MHz2GS/s7inchcolorDSO7304B4300MHz2GS/s7inchcolorTableSTYLEREF1\s2SEQTable\*ARABIC\s11ModelListofDSO7004BSeriesDSO7004BSeriesoscilloscopescoverthebandwidthsfrom80MHzto300MHz,andprovidethereal-timeandequivalentsampleratesrespectivelyupto2GSa/sand25GSa/s.Inaddition,theyhave7inchcolorTFTLCDaswellasWINDOWS-styleinterfacesandmenusforeasyoperation.What’smore,theplentymenuinformationandtheeasy-to-operatebuttonsallowyoutogaininformationasmuchaspossibleinmeasurement;themultifunctionalknobsandthepowerfulshortcutkeyshelpyousavealotoftimeinoperation;theAutosetfunctionletsyoudetectsineandsquarewavesautomatically;theProbeCheckWizardguidesyoutoadjusttheprobecompensationandsettheProbeoptionattenuationfactor.Byusingthethreemethodstheoscilloscopeprovides(context-sensitive,hyperlinks,andanindex),youmaymasteralloperationsonthedeviceinquiteashorttimesoastogreatlyimproveyourefficiencyinproductionanddevelopment.GettingStartedGuideGettingStartedGuideInstallationTokeepproperventilationoftheoscilloscopeinoperation,leaveaspaceofmorethan5cmawayfromthetopandthetwosidesoftheproduct.PowerSupplyUseapowersupplythatdelivers90to240VRMS,45to440Hz.PowerCordUseonlypowercordsdesignedforthisproduct.Referto8.2Accessoriesforspecificstandards.FunctionalCheckFollowthestepsbelowtoperformaquickfunctionalchecktoyouroscilloscope.PowerontheoscilloscopePlugintheoscilloscopeandpresstheON/OFFbutton.Thenpushthe“UTILITY->F6->F6->F6->DEFAULT”button.ThedefaultProbeoptionattenuationsettingis10X.ConnecttheoscilloscopeSettheswitchontheprobeto10XandconnecttheprobetoChannel1ontheoscilloscope.First,aligntheslotintheprobeconnectorwiththeprotuberanceontheCH1BNCandpushtoconnect;then,turntorighttolocktheprobeinplace;afterthat,connecttheprobetipandreferenceleadtothePROBECOMPconnectors.Thereisamarkonthepanel:ProbeCOMP~2V@1KHz.CH1:CH1:toconnectwiththeprobePROBECOMPObservethewaveformPresstheAUTOSETbuttonandyoushouldseewithinafewsecondsasquarewaveofabout2Vpeak-to-peakat1kHzinthedisplay.PresstheCH1MENUbuttontwicetoremoveChannel1.PushtheCH2MENUbuttonandrepeatStep2andStep3toobserveChannel2.ProbeExaminationSafetyWhenusingtheprobe,keepyourfingersbehindtheguardontheprobebodytoavoidelectricshock.Donottouchmetallicportionsoftheprobeheadwhileitisconnectedtoavoltagesource.Connecttheprobetotheoscilloscopeandconnectthegroundterminaltogroundbeforeyoustartanymeasurements.UseofProbeCheckWizardEverytimeyouconnectaprobetoaninputchannel,youshouldusetheprobecheckwizardtoverifythatthisprobeisoperatingcorrectly.Therearetwowaystodothis:Usetheverticalmenu(forexample,pushtheCH1MENUbutton)tosettheProbeoptionattenuationfactor.PresstheUTILITY->F6->F6->F6->PROBECHECKbuttontousetheProbeCheckWizardandconfiguretheprobeoptionattenuationfactorproperlyfollowingmenuprompts.ManualProbeCompensationUponthefirstconnectionofaprobeandaninputchannel,youshouldmanuallyperformthisadjustmenttomatchtheprobetotheinputchannel.Uncompensatedormiscompensatedprobesmayleadtoerrorsorfaultsinmeasurement.Toadjusttheprobecompensation,followthestepsbelow.SettheProbeoptionattenuationinthechannelmenuto10X.Settheswitchontheprobeto10XandconnecttheprobetoChannel1ontheoscilloscope.Ifyouusetheprobehook-tip,ensureitisfirmlyinsertedontotheprobe.AttachtheprobetiptothePROBECOMP~2V@1KHzconnectorandthereferenceleadtothePROBECOMPGroundconnector.DisplaythechannelandthenpresstheAUTOSETbutton.Checktheshapeofthedisplayedwaveform.CompensatedCompensatedcorrectlyOvercompensatedUndercompensatedIfnecessary,useanonmetallicscrewdrivertoadjustthevariablecapacityofyourprobeuntiltheshapeofthewaveformturnstobethesameastheabovefigure.Repeatthisstepasnecessary.Seethefigurebelowforthewayofadjustment.ProbeAttenuationSettingProbesareofvariousattenuationfactorswhichaffecttheverticalscaleofthesignal.TheProbeCheckfunctionisusedtoverifyiftheProbeattenuationoptionmatchestheattenuationoftheprobe.AsanalternativemethodtoProbeCheck,youcanpushaverticalmenubutton(suchastheCH1MENUbutton)andselecttheProbeoptionthatmatchestheattenuationfactorofyourprobe.MakesurethattheAttenuationswitchontheprobematchestheProbeoptionintheoscilloscope.Switchsettingsare1Xand10X.WhentheAttenuationswitchissetto1X,theprobelimitsthebandwidthoftheoscilloscopeto6MHz.Tousethefullbandwidthoftheoscilloscope,besuretosettheswitchto10X.SelfCalibrationTheselfcalibrationroutinehelpsoptimizetheoscilloscopesignalpathformaximummeasurementaccuracy.Youcanruntheroutineatanytimebutshouldalwaysrunitiftheambienttemperaturechangesby5℃ormore.Foramoreaccuratecalibration,pleasepowerontheoscilloscopeandwaitfor20minutesTocompensatethesignalpath,disconnectanyprobesorcablesfromthefront-panelinputconnectors.Then,pushtheUTILITYbutton,selecttheSelfCalibrationoptionandfollowthedirectionsonthescreen..MainFeatureDescriptionMainFeatureDescriptionThischapterprovidessomegeneralinformationthatyouneedtolearnbeforeusinganoscilloscope.Itcontains:1.Oscilloscopesetup2.Trigger3.Dataacquisition4.Waveformscalingandpositioning5.WaveformmeasurementOscilloscopeSetupWhileoperatingtheoscilloscope,youmayoftenusethreefeatures:Autoset,savingasetupandrecallingasetup.Hereinaftertheyareintroducedonebyone.Autoset:Thisfunctioncanbeusedtoadjustthehorizontalandverticalscalesoftheoscilloscopeautomaticallyandsetthetriggercoupling,type,position,slope,levelandmode,etc.,toacquireastablewaveformdisplay.SavingaSetup:Bydefault,theoscilloscopewillsavethesetupeachtimebeforebeingclosed,andautomaticallyrecallthesetuponcebeingturnedon.(Note:Ifyoumodifythesetup,pleasewaitformorethan5secondsbeforeturningofftheoscilloscopetoensuretheproperstorageofnewsettings.)Youcansave10settingspermanentlyintheoscilloscopeandresetthemasnecessary.RecallingaSetup:Theoscilloscopecanrecallanyofyoursavedsetupsorthedefaultfactorysetup.DefaultSetup:Theoscilloscopeispresetfornormaloperationswhenitisshippedfromthefactory.Thisisthedefaultsetup.Youmayrecallthissetupatanytimeforyourrequirements.Toviewthedefaultsettings,refertoSection5.6.3.TriggerThetriggerdetermineswhentheoscilloscopebeginstoacquiredataanddisplayawaveform.Onceatriggerisproperlysetup,theoscilloscopecanconvertunstabledisplaysorblankscreenstomeaningfulwaveforms.Hereintroducesomebasicconceptsabouttrigger.TriggerSource:Thetriggercanbegeneratedwithmultiplesources.Themostcommononeistheinputchannel(alternativebetweenCH1,CH2,CH3andCH2).Whethertheinputsignalisdisplayedornot,itcantriggernormaloperations.AlsothetriggersourcecanbeanysignalconnectedtoanexternaltriggerchannelortheACpowerline(onlyforEdgetriggers).ThesourcewiththeACpowerlineshowsthefrequencyrelationshipbetweenthesignalandtheACcommercialpower.TriggerType:Theoscilloscopehassixtypesoftriggers:Edge,Video,PulseWidth,Slope,OvertimeandAlter.EdgeTriggerusestheanalogordigitaltestcircuitsfortriggering.Ithappenswhentheinputtriggersourcecrossesaspecifiedlevelinaspecifieddirection.VideoTriggerperformsafieldorlinetriggerthroughstandardvideosignals.PulseWidthTriggercantriggernormalorabnormalpulsesthatmeettriggerconditions.SlopeTriggerusestheriseandfalltimesontheedgeofsignalfortriggering.OvertimeTriggerhappensaftertheedgeofsignalreachesthesettime.AlterTrigger,asafeatureofanalogoscilloscopes,givesstabledisplaysofsignalsattwodifferentfrequencies.MainlyitusesaspecificfrequencytoswitchbetweentwoanalogchannelsCH1andCH2sothatthechannelswillgenerateAltertriggersignalsthroughthetriggercircuitry.TriggerMode:YoucanselecttheAutoorNormalmodetodefinehowtheoscilloscopeacquiresdatawhenitdoesnotdetectatriggercondition.AutoModeperformstheacquisitionfreelyinabsenceofvalidtrigger.Itallowsthegenerationofuntriggeredwaveformswiththetimebasesetto80ms/divorslower.NormalModeupdatesthedisplayedwaveformsonlywhentheoscilloscopedetectsavalidtriggercondition.Beforethisupdate,theoscilloscopestilldisplaystheoldwaveforms.Thismodeshallbeusedwhenyouwanttoonlyviewtheeffectivelytriggeredwaveforms.Inthismode,theoscilloscopedisplayswaveformsonlyafterthefirsttrigger.Toperformasinglesequenceacquisition,pushtheSINGLESEQbutton.TriggerCoupling:TriggerCouplingdetermineswhichpartofthesignalwillbedeliveredtothetriggercircuit.Thiscanhelptoobtainastabledisplayofthewaveform.Tousetriggercoupling,pushtheTRIGMENUbutton,selectanEdgeorPulsetrigger,andthenselectaCouplingoption.TriggerPosition:Thehorizontalpositioncontrolestablishesthetimebetweenthetriggerpositionandthescreencenter.SlopeandLevel:TheSlopeandLevelcontrolshelptodefinethetrigger.TheSlopeoptiondetermineswhetherthetriggerpointisontherisingorfallingedgeofasignal.Toperformthetriggerslopecontrol,presstheTRIGMENUbutton,selectanEdgetrigger,andusetheSlopebuttontoselectrisingorfalling.TheTRIGGERLEVELknobcontrolsthetriggerpointisonwhichpositionoftheedge.TriggerslopecanberisingorfallingTriggerslopecanberisingorfallingRisingEdgeFallingEdgeTriggerlevelcanbeadjustedverticallyDataAcquisitionWhenyouacquireananalogsignal,theoscilloscopewillconvertitintoadigitalone.Therearetwokindsofacquisition:Real-timeacquisitionandEquivalentacquisition.Thereal-timeacquisitionhasthreemodes:Normal,PeakDetect,andAverage.Theacquisitionrateisaffectedbythesettingoftimebase.Normal:Inthisacquisitionmode,theoscilloscopesamplesthesignalinevenlyspacedintervalstoestablishthewaveform.Thismodeaccuratelyrepresentssignalsinmosttime.However,itdoesnotacquirerapidvariationsintheanalogsignalthatmayoccurbetweentwosamples,whichcanresultinaliasingandmaycausenarrowpulsestobemissed.Insuchcases,youshouldusethePeakDetectmodetoacquiredata.PeakDetect:Inthisacquisitionmode,theoscilloscopegetsthemaximumandminimumvaluesoftheinputsignalovereachsampleintervalandusesthesevaluestodisplaythewaveform.Inthisway,theoscilloscopecanacquireanddisplaythosenarrowpulsesthatmayhaveotherwisebeenmissedinNormalmode.However,noisewillappeartobehigherinthismode.Average:Inthisacquisitionmode,theoscilloscopeacquiresseveralwaveforms,averagesthem,anddisplaystheresultingwaveform.Youcanusethismodetoreducerandomnoise.EquivalentAcquisition:Thiskindofacquisitioncanbeutilizedforperiodicsignals.Incasetheacquisitionrateistoolowwhenusingthereal-timeacquisition,theoscilloscopewilluseafixedratetoacquiredatawithastationarytinydelayaftereachacquisitionofaframeofdata.AfterrepeatingthisacquisitionforNtimes,theoscilloscopewillarrangetheacquiredNframesofdatabytimetomakeupanewframeofdata.Thenthewaveformcanberecovered.ThenumberoftimesNisrelatedtotheequivalentacquisitionrate.TimeBase:Theoscilloscopedigitizeswaveformsbyacquiringthevalueofaninputsignalatdiscretepoints.Thetimebasehelpstocontrolhowoftenthevaluesaredigitized.UsetheSEC/DIVknobtoadjustthetimebasetoahorizontalscalethatsuitsyourpurpose.WaveformScalingandPositioningThedisplayofwaveformsonthescreencanbechangedbyadjustingtheirscaleandposition.Oncethescalechanges,thewaveformdisplaywillincreaseordecreaseinsize.Oncethepositionchanges,thewaveformwillmoveup,down,right,orleft.Thechannelreferenceindicator(locatedontheleftofthegraticule)identifieseachwaveformonthescreen.Itpointstothegroundlevelofthewaveformrecord.VerticalScaleandPosition:Theverticalpositionofawaveformcanbechangedbymovingitupanddownonthescreen.Tocomparedata,youmayalignawaveformoveranother.WhenyoupushtheVOLTS/DIVbuttontochangetheverticalscaleofawaveform,thewaveformdisplaywillcontractorexpandverticallytothegroundlevel.HorizontalScaleandPosition:PretriggerInformationYoucanadjusttheHORIZONTALPOSITIONcontroltoviewwaveformdatabeforethetrigger,afterthetrigger,orsomeofeach.Whenyouchangethehorizontalpositionofawaveform,youareactuallychangingthetimebetweenthetriggerpositionandthescreencenter.Forexample,ifyouwanttofindoutthecauseofaglitchinyourtestcircuit,youshouldtriggerontheglitchandmakethepretriggerperiodlongenoughtocapturedatabeforetheglitch.Thenyoucananalyzethepretriggerdataandperhapsfindthecause.YouareallowedtochangethehorizontalscaleofallthewaveformsbyturningtheSEC/DIVknob.Forexample,youmaywanttoseejustonecycleofawaveformtomeasuretheovershootonitsrisingedge.Theoscilloscopeshowsthehorizontalscaleastimeperdivisioninthescalereadout.Sinceallactivewaveformsusethesametimebase,theoscilloscopeonlydisplaysonevalueforalltheactivechannels.WaveformMeasurementTheoscilloscopedisplaysgraphsofvoltageversustimeandcanhelptomeasurethedisplayedwaveform.Thereareseveralwaystotakemeasurements,usingthegraticule,thecursorsorperforminganautomaticmeasurement.Graticule:Thismethodallowsyoutomakeaquick,visualestimateandtakeasimplemeasurementthroughthegraticuledivisionsandthescalefactor.Forexample,youcantakesimplemeasurementsbycountingthemajorandminorgraticuledivisionsinvolvedandmultiplyingbythescalefactor.Ifyoucounted6majorverticalgraticuledivisionsbetweentheminimumandmaximumvaluesofawaveformandknewyouhadascalefactorof50mV/division,youcouldeasilycalculateyourpeak-to-peakvoltageasfollows:6divisionsx50mV/division=300mV.Cursor:Thismethodallowsyoutotakemeasurementsbymovingthecursors.Cursorsalwaysappearinpairsandthedisplayedreadoutsarejusttheirmeasuredvalues.Therearetwokindsofcursors:AmplitudeCursorandTimeCursor.Theamplitudecursorappearasahorizontalbrokenline,measuringtheverticalparameters.Thetimecursorappearasaverticalbrokenline,measuringthehorizontalparameters.Whenusingcursors,pleasemakesuretosettheSourcetothewaveformthatyouwanttomeasureonthescreen.Tousecursors,pushtheCURSORbutton.CursorCursorCursorAutomaticMeasurement:Theoscilloscopeperformsallthecalculationsautomaticallyinthismode.Asthismeasurementusesthewaveformrecordpoints,itismoreprecisethanthegraticuleandcursormeasurements.AutomaticmeasurementsshowthemeasurementresultsbyreadoutswhichareperiodicallyupdatedwiththenewdataacquiredbytheoscilloscopeBasicOperationBasicOperationThefrontpaneloftheoscilloscopeisdividedintoseveralfunctionalareas.Inthischapterwewillgiveaquickoverviewofallcontrolbuttonsandknobsonthefrontpanelaswellasthedisplayedinformationonthescreenandrelativetestingoperations.ThefigurebelowillustratesthefrontpaneloftheDSO7004Bseriesdigitaloscilloscope.FrontPanelofDSO7004BSeriesDisplayArea1010131211171615141234567891819DisplayFormat:::YT:Vectors:Grayindicatesautopersistence;Greenmeanspersistencedisplayisenabled.Whentheiconissettogreen,thetimeforpersistencedisplaywillbeshownbehindit.:XY:DotsAcquisitionMode:Normal,PeakDetectorAverageTriggerStatus:Theoscilloscopeisacquiringpretriggereddata.Allpretriggereddatahavebeenacquiredandtheoscilloscopeisreadytoacceptatrigger.TTheoscilloscopehasdetectedatriggerandisacquiringtheposttriggerinformation.Theoscilloscopeworksinautomodeandisacquiringwaveformsintheabsenceoftriggers.Theoscilloscopeisacquiringanddisplayingwaveformdatacontinuouslyinscanmode.●Theoscilloscopehasstoppedacquiringwaveformdata.STheoscilloscopehasfinishedasinglesequenceacquisition.ToolIcon::Ifthisiconlightsup,itmeansthekeyboardoftheoscilloscopeislockedbythehostcomputerviaUSBcontrol.:Ifthisiconlightsup,itmeanstheUSBdiskhasbeenconnected.:ThisiconlightsuponlywhentheUSBslaveinterfaceisconnectedwiththecomputer.Readoutshowsmaintimebasesetting.MainTimeBaseWindowDisplayofwindow’spositionindatamemoryanddatalength.WindowTimeBaseOperatingMenushowsdifferentinformationfordifferentfunctionkeys.Readoutshowsfrequencycount.ReadoutpointsouthorizontalwaveformpositionTriggerType::Edgetriggerontherisingedge.:Edgetriggeronthefallingedge.:Videotriggerwithlinesynchronization.:Videotriggerwithfieldsynchronization.:PulseWidthtrigger,positivepolarity.:PulseWidthtrigger,negativepolarity.Pop-upPromptReadouttellstriggerlevel.Iconindicateswhetherthewaveformisinvertedornot.20MBandwidthLimit.Ifthisiconlightsup,itmeansthebandwidthlimitisenabled,otherwisedisabled.Iconindicateschannelcoupling.ChannelMarkerWindowdisplayswaveform.XYFormatTheXYformatisusedtoanalyzephasedifferences,suchasthoserepresentedbyLissajouspatterns.TheformatplotsthevoltageonCH1againstthevoltageonCH2,whereCH1isthehorizontalaxisandCH2istheverticalaxis.TheoscilloscopeusestheuntriggeredNormalacquisitionmodeanddisplaysdataasdots.Thesamplingrateisfixedat1MS/s.TheoscilloscopecanacquirewaveformsinYTformatatanysamplingrate.YoumayviewthesamewaveforminXYformat.Toperformthisoperation,stoptheacquisitionandchangethedisplayformattoXY.ThetablebelowshowshowtooperatesomecontrolsinXYformat.ControlsUsableornotinXYformatCH1VOLTS/DIVandVERTICALPOSITIONcontrolsSetthehorizontalscaleandpositionCH2VOLTS/DIVandVERTICALPOSITIONcontrolsContinuouslysettheverticalscaleandpositionReferenceorMathUnusableCursorsUnusableAutoset(displayformatresettoYT)UnusableTimebasecontrolsUnusableTriggercontrolsUnusableHorizontalControlsUsethehorizontalcontrolstochangethehorizontalscaleandpositionofwaveforms.Thehorizontalpositionreadoutshowsthetimerepresentedbythecenterofthescreen,usingthetriggertimeaszero.Whenyouchangethehorizontalscale,thewaveformwillexpandorcontracttothescreencenter.Thereadoutneartheupperrightofthescreenshowsthecurrenthorizontalpositioninsecond.Mrepresents‘MainTimeBase’,andWindicates‘WindowTimeBase’.Theoscilloscopealsohasanarrowiconatthetopofthegraticuletoindicatethehorizontalposition.1.HORIZONTALPOSITIONKnob:Usedtocontrolthetriggerpositionagainstthescreencenter.Pushthisbuttontoresetthetriggerpointbacktothescreencenter.AN:Usedtosetthehorizontalpositionaszero.Single-windowModeDual-windowMode(FullScreen)MajorWindowMajorWindowMinorWindow(ExpandedWindow)LocationofexpandedwindowdatainmemoryMulti-functionalMulti-functionalKnob3.SEC/DIVKnob:Usedtochangethehorizontaltimescalesoastomagnifyorcompressthewaveformhorizontally.Ifthewaveformacquisitionisstopped(byusingtheRUN/STOPorSINGLESEQbutton),theSE
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 二零二五年度倉儲物流租賃管理協(xié)議范本2篇
- 個人場地租賃合同(2024版)6篇
- 專線接入服務個性化協(xié)議范例2024版A版
- 2024用戶服務合同模板
- 二零二五年度特色火鍋店租賃合同范本3篇
- 2025年度柴油產品質量保證合同模板4篇
- 2024年規(guī)范珠寶玉石市場買賣協(xié)議樣本版B版
- 2025年度智能公寓租賃管理服務合同標準2篇
- 2025年度餐飲娛樂場地租賃合同范本12篇
- 2025年茶葉深加工項目合作協(xié)議4篇
- 三年級數(shù)學(上)計算題專項練習附答案
- GB/T 12723-2024單位產品能源消耗限額編制通則
- 2024年廣東省深圳市中考英語試題含解析
- GB/T 16288-2024塑料制品的標志
- 麻風病防治知識課件
- 建筑工程施工圖設計文件審查辦法
- 干部職級晉升積分制管理辦法
- 培訓機構應急預案6篇
- 北師大版數(shù)學五年級上冊口算專項練習
- 應急物資智能調配系統(tǒng)解決方案
- 2025年公務員考試時政專項測驗100題及答案
評論
0/150
提交評論