深圳市有限企業(yè)冷庫工程設(shè)計(jì)方案編制單位:深圳市西谷制冷設(shè)備有限企業(yè)編制時(shí)間:六月二十六日目錄一.基本設(shè)備概況··········································2二.設(shè)計(jì)規(guī)范及冷庫冷負(fù)荷計(jì)算······························2三.冷庫設(shè)計(jì)的尤其規(guī)定技術(shù)規(guī)范···························5四.裝配式冷藏庫技術(shù)規(guī)定·································7五.工程實(shí)行規(guī)定·········································17六.技術(shù)文獻(xiàn)和資料規(guī)定···································28七、動(dòng)工匯報(bào)·············································31八、材料進(jìn)廠清單·········································32九、工具進(jìn)廠清單·········································33十、工程材料、構(gòu)配件、設(shè)備報(bào)審表····························34十一、壓力<嚴(yán)密性>試驗(yàn)記錄·······························35一.基本設(shè)備概況冷庫名稱冷庫規(guī)格制冷設(shè)備概況套臺(tái)二.設(shè)計(jì)規(guī)范及冷庫冷負(fù)荷計(jì)算1設(shè)計(jì)規(guī)范1.1 室外環(huán)境1、夏季通風(fēng)室外計(jì)算干球溫度:TWK=5℃~38℃2、夏季空氣調(diào)整室外計(jì)算日平均干球溫度:33℃3、夏季空氣調(diào)整室外計(jì)算日平均濕球溫度:TWS=28℃4、夏季室外計(jì)算相對(duì)濕度:30%~85%5、年平均氣壓:1012hPa6、極端最高溫度:42℃7、極端最低溫度:5℃。1.2 室內(nèi)環(huán)境1、室內(nèi)溫度:15℃~35℃,相對(duì)濕度:(70%冬季),(85%夏季)2、室內(nèi)最大相對(duì)濕度:日平均不不小于90%(25℃時(shí))3、地震地面加速度:水平加速度不超過0.2G,垂直加速度不超過0.1G4、電力供應(yīng):TN-S制,額定電壓為380V/220V,電壓波動(dòng)率:±7%,額定頻率為50Hz,頻率波動(dòng)率:±2%,接地電阻不不小于1Ω。1.3 氣候條件的適應(yīng)性西谷制冷設(shè)備廠所有設(shè)備能適應(yīng)現(xiàn)場(chǎng)的上述條件,并針對(duì)項(xiàng)目所在地的詳細(xì)狀況,設(shè)有三防措施(防潮,防腐,防銹)并滿足這些條件。冷庫為整年365天,持續(xù)運(yùn)行。1.4 本項(xiàng)目的冷庫制冷系統(tǒng)、庫體工程是交鑰匙工程,所提交的系統(tǒng)是通電即可使用的系統(tǒng)。西谷將對(duì)冷庫總體性,成套性負(fù)責(zé)。1.5 客戶所規(guī)定的系統(tǒng)為冷庫系統(tǒng)套,庫體工程套。西谷所生產(chǎn)的這些系統(tǒng)是優(yōu)質(zhì)、完整、技術(shù)先進(jìn)、操作以便、免維護(hù)的獨(dú)立冷源裝配式冷庫系統(tǒng)。系統(tǒng)須保證符合技術(shù)規(guī)格書的規(guī)定。其中包括招標(biāo)技術(shù)文獻(xiàn)中明確描述或暗示的以及有效完畢系統(tǒng)功能所需的所有系統(tǒng)和設(shè)備的設(shè)計(jì)、制造、裝配、檢查、運(yùn)送、倉儲(chǔ)、安裝、調(diào)試、初驗(yàn)、試運(yùn)行、工程監(jiān)督、勞務(wù)、最終驗(yàn)收和售后服務(wù),以及上述工作所需的設(shè)備、材料、附件、配件、工具、儀器、易耗件和備件的提供等,并按照上述次序向招標(biāo)人移交完整的獨(dú)立冷源裝配式冷庫系統(tǒng)、庫體以及有關(guān)文獻(xiàn)資料,并保證符合技術(shù)文獻(xiàn)的規(guī)定。西谷只有在得到客戶實(shí)業(yè)簽發(fā)的驗(yàn)收合格書面證明后,各項(xiàng)工作和整個(gè)工程才能算完畢。2詳細(xì)工作內(nèi)容(1). 1間冷庫所有的冷庫系統(tǒng)(系統(tǒng)設(shè)備至少包括但不限于2.1、2.2節(jié)中規(guī)定的內(nèi)容),包括系統(tǒng)選型設(shè)計(jì)(含出圖),各項(xiàng)指標(biāo)的優(yōu)化,包括但不限于機(jī)組、庫板、庫門、設(shè)備的選用、集成、供貨、儲(chǔ)存、安裝、調(diào)試、驗(yàn)收等工作;(2). 冷庫系統(tǒng)設(shè)備的安裝、調(diào)試;含冷庫的控制和監(jiān)控:(包括現(xiàn)場(chǎng)監(jiān)控、顯示和預(yù)留遠(yuǎn)程監(jiān)測(cè)線路端子)];(3). 冷庫內(nèi)聚氨酯保溫地面、包括保溫層、防凍、防水層等供貨和施工。保證地面防滑處理。(4). 冷庫系統(tǒng)范圍內(nèi)的供電、照明、排水等工作由投標(biāo)人完畢。(5). 與建筑等各其他系統(tǒng)承包商配合完畢所有接口工作;連接至招標(biāo)圖紙所示接口位置;(6). 系統(tǒng)的配置包括冷凝壓縮機(jī)組、管路、控制系統(tǒng),加注好制冷劑和冷凍油等,所有設(shè)備的安裝、管路連接、電線連接、調(diào)試等服務(wù);(7). 提供所有設(shè)備安裝及連接、調(diào)試所需之連接件、緊固件、防護(hù)材料及其他消耗品,包括在圖紙上、文獻(xiàn)上未提及但為完畢本協(xié)議工作及設(shè)備合理運(yùn)行所需要的附件和材料等。(8). 冷庫系統(tǒng)設(shè)備的調(diào)試、維護(hù)與質(zhì)量保證服務(wù);(9). 人員培訓(xùn);(10). 附件、備件、專用工具供貨;(11). 售后服務(wù)和技術(shù)支持。3系統(tǒng)設(shè)計(jì)壽命系統(tǒng)的設(shè)計(jì)壽命≥,并且可以以每年365天、每天24小時(shí)的工作循環(huán)持續(xù)運(yùn)行。重要設(shè)備和部件的壽命規(guī)定如下;序號(hào)設(shè)備單位壽命備注1庫體年≥152蒸發(fā)器年≥103冷媒管道年≥154冷凝壓縮機(jī)組小時(shí)≥10萬5控制系統(tǒng)年≥154產(chǎn)品原則和規(guī)范1必須滿足的原則(1). 國(guó)家《組合式冷庫用隔熱夾心板技術(shù)條件》原則JB/T6527-92(2). 《工業(yè)企業(yè)設(shè)計(jì)衛(wèi)生原則》[GBZ1-](3). 《建筑設(shè)計(jì)防火規(guī)范》[GBJ16-87-修訂版](4). 《工業(yè)企業(yè)噪聲控制設(shè)計(jì)規(guī)范》[GBJ87-85](5). 《供配電系統(tǒng)設(shè)計(jì)規(guī)范》[GB50052-95](6). 《電氣裝置安裝工程施工及驗(yàn)收規(guī)范》[GBJ232-82](7). 其他所有合用于冷庫的國(guó)家、深圳市頒布的強(qiáng)制性規(guī)范投標(biāo)人所供應(yīng)的設(shè)備、器材、部件、材料及所完畢的安裝詳圖要完全符合上述原則,2 專業(yè)原則投標(biāo)人所提供的產(chǎn)品和施工服務(wù)必須遵守如下的有關(guān)規(guī)范、規(guī)定和原則:必須符合中國(guó)國(guó)標(biāo)或與此相稱的原則。(1). 《冷庫設(shè)計(jì)規(guī)范》(GBJ72-)(2). 《制冷設(shè)備安裝工程施工及驗(yàn)收規(guī)范》(GB50274-98)(3). 《制冷設(shè)備通用技術(shù)規(guī)范》(GBJ237-88)(4). 《現(xiàn)場(chǎng)設(shè)備、工業(yè)管道焊接工程及驗(yàn)收規(guī)范》(GBJ236-82)(5). 《工業(yè)企業(yè)噪聲控制設(shè)計(jì)規(guī)范》[GBJ87-85](6). 《美國(guó)空調(diào)冷凍協(xié)會(huì)原則》(ARI550-92)必須符合中國(guó)尤其是深圳市的有關(guān)規(guī)范、規(guī)定、原則。3 設(shè)備的設(shè)計(jì)、制造、檢查、測(cè)試、驗(yàn)收等原則應(yīng)符合國(guó)際原則化組織及國(guó)際、國(guó)內(nèi)有關(guān)行業(yè)已實(shí)行的原則。這些原則應(yīng)包括但不限于:序號(hào)代號(hào)名稱備注1ISO國(guó)際原則化組織原則2IEC國(guó)際電工技術(shù)委員會(huì)原則3ASTM美國(guó)材料與試驗(yàn)協(xié)會(huì)原則4AISI美國(guó)鋼鐵協(xié)會(huì)5DIN德國(guó)國(guó)標(biāo)6DVE德國(guó)電工組織7JIS日本工業(yè)原則8SI國(guó)際單位制9BS英國(guó)國(guó)標(biāo)10EN歐洲原則11UL美國(guó)保險(xiǎn)商安全原則12ASME美國(guó)機(jī)械工程師協(xié)會(huì)原則13ANSI美國(guó)國(guó)標(biāo)協(xié)會(huì)原則14JIC聯(lián)合工業(yè)大會(huì)原則15SAE自動(dòng)工程協(xié)會(huì)原則16AWS鋼鐵構(gòu)造涂層協(xié)會(huì)原則17SSPC美國(guó)焊接協(xié)會(huì)原則18NFPA417美國(guó)國(guó)家防火保護(hù)協(xié)會(huì)原則19AIA美國(guó)保險(xiǎn)協(xié)會(huì)原則20NEMA國(guó)家電器生產(chǎn)協(xié)會(huì)原則21NEC英國(guó)國(guó)家電器法規(guī)5冷庫負(fù)荷計(jì)算1、室外環(huán)境1.1、夏季通風(fēng)計(jì)算室外干球溫度:TWK5℃-38℃.1.2、夏季空氣調(diào)整室外計(jì)算日平均干球溫度:33℃.1.3、夏季空氣調(diào)整室外計(jì)算日平均濕球溫度:TWS28℃.1.4、夏季室外計(jì)算相對(duì)濕度:30%-85%.1.5、年平均氣壓:1012hpa.1.6、極端最高溫度:42℃.1.7、極端最低溫度:5℃.2、室內(nèi)壞境2.1、室內(nèi)溫度:15℃-35℃;相對(duì)濕度:70%(冬季),85%(夏季)2.2、室內(nèi)最大相對(duì)濕度:25℃時(shí),日平均不不小于90%.2.3、電力供應(yīng):TCV-S制,額定電壓為380V/220V,電波動(dòng)率:±7%額定頻率50HZ,頻率波動(dòng)率±2%,基地電阻不不小于1Ω。2.4、地震地面加速度:水平加速度不超過0.2G,垂直加速度不超過0.1G.3冷庫負(fù)荷計(jì)算3.1規(guī)格:15200mm×6800mm×2900mmH庫容積295m3,溫度2至8℃,濕度50%-65%.寄存物品:食品類.庫板厚度:100mm3.2、冷負(fù)荷圍護(hù)構(gòu)造傳熱量Q1=Qq+Qy墻壁樓板及屋頂?shù)膫鳠崃縌q=AK(Tw-Tn)n.其中A=圍護(hù)構(gòu)造面積105㎡K=圍護(hù)構(gòu)造的傳熱系數(shù)為0.0276W/(㎡·k)Tw:圍護(hù)外側(cè)溫度30℃Tn:圍護(hù)內(nèi)側(cè)溫度8℃n:圍護(hù)構(gòu)造內(nèi)外溫度差修正系數(shù)1.5.計(jì)算的Qq=956wQy為太陽輻射引起的耗冷量.Qy=RF△TyR:墻壁的傳熱系數(shù)0.0276w/(㎡·k)F:太陽輻射的圍護(hù)面積8㎡△Ty=受太陽輻射影響的晝夜平均溫差4k由于是地下室,因此由于太陽輻射引起的耗冷量基本為9w3.3、貨品熱量Q2=M(h1-h2)/nz+m(T1-T2)c/nz+m(q1+q2)/2n式中M:貨品儲(chǔ)量,按庫容10%計(jì)算為110m3n:冷加工周轉(zhuǎn)次數(shù)2m:貨品包裝材料為8m3c:貨品包裝材料比熱容1.46h1、h2:貨品入庫前后的熱容值為1.98、1.55KJT1、T2:貨品入庫前后溫度為+30、5℃計(jì)算得Q2=86GTn(G:制冷備生產(chǎn)能力單位噸/天,Tn冷庫庫溫)根據(jù)計(jì)算得出冷負(fù)荷值為w/m3h。(c1工況)冷庫小時(shí)所需要冷量值kw。根據(jù)壓縮機(jī)參數(shù)和以上數(shù)據(jù),選擇套風(fēng)冷機(jī)組。三.冷庫設(shè)計(jì)的尤其規(guī)定技術(shù)規(guī)范(符合GSM原則) 通用技術(shù)規(guī)定1 抗無線電干擾2 西谷通過恰當(dāng)?shù)脑O(shè)計(jì)和/或屏蔽措施保證系統(tǒng)設(shè)備不發(fā)出可干擾本建筑內(nèi)各通信系統(tǒng)和弱電系統(tǒng)的電磁波。不會(huì)產(chǎn)生對(duì)各通訊、弱電、廣播、電視、樓宇等系統(tǒng)的通訊干擾。3 設(shè)計(jì)生產(chǎn)的所有電氣電子設(shè)備(包括計(jì)算機(jī)和有關(guān)網(wǎng)絡(luò)設(shè)備)都可以在建筑內(nèi)其他正常安裝的或使用的設(shè)備發(fā)出的電磁波環(huán)境中正常工作。這些正常電磁波包括但不限于通信頻帶、廣播、電視的功率發(fā)射系統(tǒng)、多種電機(jī)和控制器、電動(dòng)工具、焊接設(shè)備、汽車、供電設(shè)備、空氣處理設(shè)備等。必要時(shí)配置隔離裝置和線路克制裝置。4.電氣、電子設(shè)備,包括聯(lián)結(jié)電線、電纜的設(shè)計(jì),使它們不受使用和安裝的其他設(shè)備產(chǎn)生的電磁波的干擾,而正常工作。5 本系統(tǒng)內(nèi)控制、通信、信息傳送使用了無線傳播和手機(jī)短信故障提醒功能,這些通訊裝置符合國(guó)家和深圳市有關(guān)部門同意的管理頻帶。6防蟲防鼠7、 所有的設(shè)備、裝置均有防潮、防霉菌、防昆蟲和鼠害的措施。8、所有的設(shè)備有效的措施防止鼠類等嚙齒動(dòng)物進(jìn)入,防止導(dǎo)致設(shè)備和系統(tǒng)的損害,設(shè)備和裝置貨能有效的防止其他昆蟲和動(dòng)物的進(jìn)入導(dǎo)致設(shè)備的故障。9 冷庫配置有效的防潮、防霉菌裝置。10、銘牌及各類標(biāo)識(shí)11 設(shè)備銘牌:設(shè)備至少必須設(shè)置如下多種永久性的不易損毀和腐蝕的金屬標(biāo)牌11. 設(shè)備在合適醒目的位置上設(shè)置銘牌,標(biāo)明設(shè)備名稱、型號(hào)、重要規(guī)格、編號(hào)、以及制造廠名稱和制造日期等。12. 操作控制部分,在合適位置放置操作按鈕等的操作使用闡明牌和指示牌。13. 為了安全生產(chǎn),設(shè)置防止發(fā)生危險(xiǎn)的警告指示牌。14. 在合適的位置上,設(shè)置需常常潤(rùn)滑的各部位潤(rùn)滑的闡明牌。15 銘牌文字:設(shè)備銘牌上內(nèi)容用中文或英文書寫并注明設(shè)備型號(hào)、制造廠名稱、出廠年月日、出廠編號(hào)、生產(chǎn)國(guó)等內(nèi)容。多種闡明牌、指示牌、標(biāo)簽和標(biāo)識(shí)均用中文或中英文對(duì)照書寫。16、標(biāo)識(shí)和標(biāo)簽17. 每個(gè)開關(guān)箱、控制柜中的重要部件均有一種標(biāo)明該部件在裝置中用途、目的的標(biāo)簽。18. 所有印刷線路板均有型號(hào)標(biāo)識(shí),電子元件柜標(biāo)明各線路板的品名,以利識(shí)別原理圖中的線路板。19. 所有電氣設(shè)備或部件的接線端都清晰地打上永久標(biāo)識(shí),所有要連接在一起的標(biāo)識(shí)號(hào)相似,標(biāo)識(shí)號(hào)碼印在短套管或類似套管物上。20 電纜及電纜芯的兩端都要有標(biāo)識(shí)。21 材料和輔料22、設(shè)備安裝和所需要的材料和輔料等符合國(guó)家/國(guó)際有關(guān)原則的規(guī)定,滿足食品衛(wèi)生、消防、環(huán)境保護(hù)、生產(chǎn)和勞動(dòng)安全等規(guī)定。其中對(duì)管材的選擇為;序號(hào)項(xiàng)目類型備注1給水管薄壁不銹鋼管、銅管壁厚執(zhí)行國(guó)標(biāo)2排水管銅管、PE管3冷凝水管不銹鋼管或者復(fù)合管壁厚執(zhí)行國(guó)標(biāo)4排風(fēng)管薄壁不銹鋼壁厚執(zhí)行國(guó)標(biāo)5冷媒管銅管壁厚執(zhí)行國(guó)標(biāo)23 安裝所使用的多種涂料、粘合劑等、填料、密封料等有害殘留物和逸出物都必須滿足食品安全的規(guī)定。24 設(shè)備防腐25 所有設(shè)備都采用防腐措施。設(shè)備內(nèi)部或者隱蔽部位必須施行防腐蝕工藝。26表面處理:表面處理是設(shè)備防腐的重要環(huán)節(jié),按照規(guī)定原則進(jìn)行。除不銹鋼外的所有裸露的且有也許發(fā)生銹蝕的金屬表面都采用防腐蝕措施,如油漆涂裝、電鍍、表面鈍化等。27有關(guān)電氣接點(diǎn)、信息線接點(diǎn)、插接接點(diǎn)等、螺紋緊固接點(diǎn)等包括弱電、信息的接點(diǎn)也采用了有效防腐蝕措施,防止在此后的運(yùn)行中發(fā)生銹蝕、接觸不良而導(dǎo)致系統(tǒng)不能穩(wěn)定工作的狀況。28、涂裝規(guī)定:加工組裝完畢的金屬構(gòu)架、鋼制件,除不銹鋼制品外,其他涂漆。29 涂裝工藝:西谷工廠采用噴涂環(huán)氧樹脂漆類工藝(俗稱烤漆),保證涂膜均勻,附著力強(qiáng),無針孔、起泡、起皺、開裂等缺陷。對(duì)構(gòu)件焊接部位和棱角在涂裝前做預(yù)處理。29 涂層厚度:在設(shè)計(jì)設(shè)備防腐層厚度時(shí),根據(jù)設(shè)備所在現(xiàn)場(chǎng)環(huán)境條件按照有關(guān)防腐涂裝標(biāo)精確定。但凡沒有明確規(guī)定的防腐層(油漆)厚度需≥80微米。30 涂裝顏色:設(shè)備和管道外部的顏色考慮整體的統(tǒng)一協(xié)調(diào)、美觀,涂裝的顏色初步選擇淡灰色。31涂裝清單:西谷對(duì)自己所提供的設(shè)備或部件采用的涂裝工藝列出詳細(xì)清單,在提交設(shè)計(jì)方案審查時(shí),連同圖紙一并交給招標(biāo)人審查,以審查確定的清單為驗(yàn)收根據(jù)。32電子設(shè)備加固和防護(hù)33 所有安裝在現(xiàn)場(chǎng)的所有電子設(shè)備和裝置等采用合用于工業(yè)環(huán)境的加固措施,要牢固裝于加固機(jī)箱內(nèi)。必須保證能適應(yīng)現(xiàn)場(chǎng)溫度和濕度條件。34 安裝在現(xiàn)場(chǎng)的所有控制、電氣箱或者裸裝的電子裝置防護(hù)等級(jí)IP≥5X。35供電規(guī)定36西谷設(shè)備廠提供節(jié)能的系統(tǒng)。37 系統(tǒng)設(shè)備供電:設(shè)計(jì)功率為匹機(jī)組臺(tái),設(shè)備使用功率為KW,設(shè)備已經(jīng)設(shè)計(jì)了軟啟動(dòng)。最大啟動(dòng)電流為A,運(yùn)行電流為A。38節(jié)能技術(shù)的應(yīng)用39、西谷將在冷庫設(shè)備上安裝由我工廠趙立峰國(guó)家發(fā)明專利的“制冷設(shè)備的回氣再運(yùn)用”技術(shù)。此裝置能有效的節(jié)電約5%,并能有效的延長(zhǎng)壓縮機(jī)的使用壽命。40、老式的冷庫化霜是由電加熱管來完畢的,電加熱的優(yōu)勢(shì)就是造價(jià)低廉,缺陷是:效率低、耗電、易損壞、化霜易留殘?jiān)?。屬于不?jié)能產(chǎn)品。目前使用的新工藝是“熱氣融霜”他的耗電率只有電加熱的25%。其工藝原理是把壓縮的熱冷媒通過四通閥流向蒸發(fā)器,來迅速到達(dá)除霜的目的。1千瓦的電加熱理論熱值為860Kcal,1千瓦的壓縮機(jī)的冷媒產(chǎn)熱值為4200KcaL。其長(zhǎng)處為:效率高,只要5-8分鐘所有化完(電加熱要25分鐘)。不留死角,不用更換耗材。四.裝配式冷藏庫技術(shù)規(guī)定第1節(jié) 總體規(guī)定(1). 環(huán)境保護(hù):所有的材料,包括絕熱材料、制冷媒體等符合大氣保護(hù)公約法規(guī)(蒙特利爾公約),不含氯氟碳化合物(CFC或HCFC),對(duì)臭氧層無害。(Chlorinefree)(2). 制冷劑:。(3). 按照客戶的現(xiàn)場(chǎng)條件和需求進(jìn)行冷庫設(shè)計(jì)和布置,提供設(shè)備的配置狀況。繪制冷庫平面及剖面布置方案圖。繪制系統(tǒng)原理圖、管道配置圖等(圖紙?jiān)诟巾撝校?4). 提供投標(biāo)設(shè)備的產(chǎn)品樣本,包括冷凝壓縮機(jī)組、冷庫板、蒸發(fā)器、控制系統(tǒng)、電子膨脹閥、冷媒管和有關(guān)附件等。(5).提供的制冷機(jī)組應(yīng)能滿足或系統(tǒng)制冷整體性能。提供系統(tǒng)冷量平衡需求計(jì)算書,已證明制冷系統(tǒng)的配置合理性。(6). 所有裝配式冷庫的冷凝機(jī)組為室外集中式機(jī)組,按照建筑物的構(gòu)造和承重條件提出對(duì)設(shè)備基礎(chǔ)規(guī)定,提供冷媒管道配置需求,對(duì)建筑預(yù)留管道井的詳細(xì)位置及尺寸需求,對(duì)排水管道和冷庫地面下防水工程的規(guī)定,對(duì)建筑樓頂安裝冷凍壓縮機(jī)組基礎(chǔ)承重載荷的規(guī)定等。(7). 西谷完畢所有冷庫室內(nèi)外壓縮機(jī)組的安裝和管路連接、電路連接、加注制冷劑、檢漏測(cè)試、調(diào)試等直至設(shè)備能正常工作。提供制冷劑、管路絕熱層材料、管路、電纜、和橋架等。完畢設(shè)備安裝和調(diào)試。(8). 完畢冷庫內(nèi)部的隔熱層敷設(shè)和防凍、防水構(gòu)造層處理等工作。完畢隔熱庫板與庫底保溫層等連接,完畢庫內(nèi)聚氨酯地面,冷庫內(nèi)部結(jié)合處的密封等。(9).西谷提供的冷庫系統(tǒng)應(yīng)是節(jié)能的系統(tǒng),系統(tǒng)能耗到達(dá)國(guó)外先進(jìn)水平。第2節(jié) 系統(tǒng)配置和設(shè)備選型2.1 系統(tǒng)配置原則按照招標(biāo)條件規(guī)定配置系統(tǒng),各冷庫由獨(dú)立的制冷系統(tǒng)供冷。2.1.1 考慮本系統(tǒng)對(duì)使用環(huán)境的適應(yīng)性,防止使用和安裝條件的變化導(dǎo)致系統(tǒng)工作不正常,確定系統(tǒng)冷量已經(jīng)留有余地,已經(jīng)考慮夏季最熱氣溫和多冷庫同步入庫較多物料時(shí)保持冷庫內(nèi)的溫度在設(shè)定的范圍內(nèi)。2.1.2 冷媒輸送壓力和流量等已經(jīng)考慮距離和建筑高度的阻力影響,系統(tǒng)沒有設(shè)計(jì)在臨界值附近,設(shè)備尤其是關(guān)鍵設(shè)備沒有在靠近極限狀態(tài)下運(yùn)用,已經(jīng)按照規(guī)定留有合適的裕度。系統(tǒng)設(shè)計(jì)對(duì)異常條件給預(yù)足夠的考慮。2.1.3 系統(tǒng)設(shè)計(jì)為節(jié)能,減少電力的消耗,杜絕系統(tǒng)滲漏狀況。2.1.4 管路系統(tǒng)中在合適的位置安裝截止閥,以便在需要時(shí)可以停止任一冷庫機(jī)組的使用,截止閥使用電控和手動(dòng)型兩種,檢修時(shí)用手動(dòng)型關(guān)閉管路系統(tǒng)。2.1.5 工作模式:為防止庫內(nèi)溫度超標(biāo),冷媒供應(yīng)采用溫度控制的獨(dú)立方式,當(dāng)庫溫變化大,超時(shí)工作時(shí),系統(tǒng)設(shè)置將自動(dòng)使用備用機(jī)組。2.1.6 根據(jù)招標(biāo)文獻(xiàn)提供的各項(xiàng)參數(shù)和技術(shù)規(guī)定完畢系統(tǒng)的平面布置、豎向布置和系統(tǒng)詳細(xì)設(shè)計(jì)和設(shè)備配置。2.2 設(shè)備選型關(guān)鍵設(shè)備于下表所列設(shè)備。序號(hào)設(shè)備名稱配置規(guī)定參照品牌中文名稱1原裝壓縮機(jī)頭、冷凝器、油氣分離器、氣液分離器、高下壓控制、熱氣化霜裝備、缸頭風(fēng)機(jī)、電磁閥、壓力表、干燥過濾器等2蒸發(fā)器高效外轉(zhuǎn)子風(fēng)扇電機(jī)、翅片防腐涂層、雙層接水盤、不銹鋁版。SaycoldHeatcraft西谷美國(guó)西克3調(diào)整閥/控制系統(tǒng)控制系統(tǒng)能根據(jù)負(fù)荷設(shè)定自動(dòng)運(yùn)行,溫度曲線、帶記錄、存取、打印及溫度顯示等功能DANFOSS丹麥丹佛斯CAREL卡樂4冷庫保溫板按保溫庫板詳細(xì)技術(shù)規(guī)定寶冠廣東寶冠注:制冷機(jī)組配置規(guī)定根據(jù):A:節(jié)能角度規(guī)定熱氣化霜;B:蒸發(fā)器必須使用不銹鋁或者不銹鋼外殼。第3節(jié) 重要設(shè)備/部件規(guī)定3.1 制冷劑(1). 采用。3.2 制冷系統(tǒng)和壓縮機(jī)(1). 制冷機(jī)組按照各冷庫分別配置,由于項(xiàng)目為海邊都市,因此規(guī)定采用高防腐盤管機(jī)組,且使用風(fēng)冷式系統(tǒng)。(2). 制冷機(jī)組為室外安裝,提供防雨淋和太陽直射等防護(hù)設(shè)施。該機(jī)組的總重量對(duì)建筑承重基礎(chǔ)符合規(guī)定。3.2.1 提供冷庫制冷的布置圖,闡明面積的使用和機(jī)房室內(nèi)凈高度等。3.2.2 系統(tǒng)規(guī)定(1). 提供制冷系統(tǒng)包括選用的重要設(shè)備和重要原件及互相連接的管路狀況的原理圖,注明規(guī)格、型號(hào),并提供設(shè)備等樣本。(2). 所有制冷壓縮機(jī)均采配有自動(dòng)保護(hù)裝置,電動(dòng)機(jī)斷相保護(hù)裝置及故障報(bào)警裝置。(3). 制冷機(jī)組的提供的冷媒流量和冷量保證在深圳地區(qū)最高溫度天氣和滿庫容的狀況下維持庫溫在設(shè)計(jì)的溫度。(4). 投標(biāo)人要在投標(biāo)書中提供制冷系統(tǒng)的計(jì)算根據(jù)和計(jì)算成果。(5). 在系統(tǒng)實(shí)際總負(fù)荷≥10%的額定負(fù)荷的狀況下系統(tǒng)能正常啟動(dòng)和正常工作運(yùn)行。(6). 每個(gè)冷庫及冷藏間單獨(dú)設(shè)膨脹閥及控制儀表。(7). 除霜系統(tǒng)規(guī)定冷庫(3-7℃、-20℃),熱氣融霜方式。除霜系統(tǒng)及機(jī)組系統(tǒng)的回油為獨(dú)立控制系統(tǒng)。3.3 冷庫保溫板冷庫保溫板基本構(gòu)造為內(nèi)外壁板所有采用雙面彩鋼板,鋼板厚度0.426mm,保溫材料為高壓聚氨脂發(fā)泡材料。詳細(xì)如下;3.3.1 絕熱保溫板規(guī)格(1). 厚度:序號(hào)項(xiàng)目庫板厚度備注1庫溫≥0℃~5℃≥100mm包括內(nèi)外壁板厚度2庫溫≤-18~-21℃≥150mm包括內(nèi)外壁板厚度 (2). 所采用的厚度與對(duì)應(yīng)保溫材料的導(dǎo)熱系數(shù)和冷量計(jì)算值相吻合。(3). 絕熱保溫板的尺寸、形狀和制造容許差值序號(hào)冷庫編號(hào)數(shù)據(jù)備注1長(zhǎng)度尺寸偏差值<-2mm2寬度尺寸偏差值<-1mm3厚度尺寸偏差值<1%4對(duì)角線尺寸偏差值<-2mm5平面度(任意方向)<2/10003.3.2 絕熱保溫板內(nèi)外壁板(1). .絕熱壁板采用金屬壁板,壁板的表面亞光,無毒、無異味,符合國(guó)際食品衛(wèi)生原則,能在現(xiàn)場(chǎng)環(huán)境下保持長(zhǎng)期的抗腐蝕的能力。冷庫內(nèi)壁設(shè)計(jì)時(shí)已經(jīng)按照GSN原則,內(nèi)壁的所有轉(zhuǎn)交為光滑的圓弧角。3.3.3 絕熱保溫材料(1). 保溫板的絕熱材料要使用高壓聚氨脂發(fā)泡材料,阻燃型,無氯氟碳化合物。生產(chǎn)時(shí)為了改善性能加入一定比例的增強(qiáng)材料并交合成硬質(zhì)聚氨脂泡沫塑料。但不因此減低隔熱能力,材料內(nèi)添加有阻燃劑。(2). 硬質(zhì)聚氨酯泡沫塑料其物理及機(jī)械性能的實(shí)際指標(biāo):序號(hào)項(xiàng)目指標(biāo)備注1導(dǎo)熱系數(shù)墻板、頂板λ≤0.020~0.022W/m·K地板λ≤0.022~0.024W/m·K2密度(墻、頂)≥0.035~0.037kg/cm3(地面)≥0.040~0.045kg/cm33抗壓強(qiáng)度形變10%墻板、頂板≥1.5Kg/cm2地板≥2.5Kg/cm24吸水率≤4%(≤0.2Kg/m2)5自熄性≤3S(必須加入阻燃劑)≥B26閉孔率≥95%7尺寸穩(wěn)定性≤±1%8斷裂延伸率≥10%3.3.4 隔熱板整體性能(1). 隔熱板的面板與隔熱材料的粘結(jié)強(qiáng)度≥1.0kg/cm2。(0.1MPa)(2). 隔熱板的安裝結(jié)合面不容許有外露的硬質(zhì)聚氨酯泡沫塑料,結(jié)合面上不得有凸凹不小于1.5mm尺寸的缺陷并且其面積不不小于1cm2。(3). 隔熱板的板面要保持平整光滑,不能有翹曲、劃傷、磕碰、凹凸不平的缺陷。(4). 每塊隔熱板材料、鋼板及隔熱材料自身必須是持續(xù)的整體材料,構(gòu)成庫體的隔熱板沿其高度方向隔熱板必須是整體的,不得在水平方向有中間接縫。金屬內(nèi)外壁板,尤其是面向庫內(nèi)的不銹鋼內(nèi)壁板在高度方向上不能有接縫。面向走廊和廚房作為墻板的外壁板,沿高度方向上的庫頂接縫不能暴露在可視范圍內(nèi)。(5). 隔熱板的平面在50Kg/m2的均布荷載作用下,其撓度≤1/250。(6). 容許在隔熱板的內(nèi)部采用增強(qiáng)性措施來提高機(jī)械強(qiáng)度,但不容許減少隔熱效果。(7). 隔熱板的周圍(封邊)材料必須采用與隔熱材料導(dǎo)熱系數(shù)相近的高密度硬質(zhì)材料,不容許使用木質(zhì)材料或其他導(dǎo)熱系數(shù)較大的材料。(8). 隔熱板墻板與頂板,墻板與地面,墻板垂直相交處做成圓角/弧形過渡,以保持內(nèi)部衛(wèi)生和便于清潔。(9). 隔熱板之間的板縫處,熱流量不能不小于隔熱板熱流量的2倍。隔熱墻板與地面相接處,要有防止冷橋的措施。(10). 隔熱板之間的聯(lián)接構(gòu)造形式為卡勾,保證接縫之間的壓力,保證接縫處連接牢固。(11). 冷庫頂板的強(qiáng)度;冷庫跨度或面積較大時(shí),考慮冷庫頂板自身的自重和安裝蒸發(fā)器風(fēng)機(jī)的載荷,庫板的強(qiáng)度和變形,采用必須的安全措施,如鋼梁吊裝等,保證使用的安全性。3.3.5 隔熱板安裝隔熱板之間的接縫構(gòu)造采用可靠的密封構(gòu)造。應(yīng)對(duì)下述多種接縫的斷面構(gòu)造進(jìn)行闡明:a. 墻板之間水平接縫b. 墻板與中間隔墻板的接縫c. 墻板與頂棚板的接縫d. 冷庫內(nèi)的四個(gè)墻角的構(gòu)造e. 墻板與地面基礎(chǔ)的隔熱層結(jié)合處的構(gòu)造f. 相鄰冷藏間的中間隔墻板的接縫。3.3.6 庫體隔熱板的接縫的密封可靠性(1). 對(duì)所有接縫進(jìn)行檢漏和記錄。(2). 墻板與地面結(jié)合處,采用插入地面的構(gòu)造措施,使墻板的隔熱材料與地坪中的隔熱材料親密相接,有可靠的密封防潮處理。(3). 有關(guān)隔熱板的接縫,采用現(xiàn)場(chǎng)灌注發(fā)泡方式密封結(jié)合,包括所有隔熱板與板之間接縫。首先保證使兩塊隔熱板的隔熱材料可以緊密相貼,使用密封膠貼勻結(jié)合面,消除空隙,保證隔熱材料粘結(jié)。(4). 隔熱板的前后錯(cuò)位不能不小于1.0mm。(5). 有關(guān)隔熱板的測(cè)量、安裝。以實(shí)際完畢建筑構(gòu)造尺寸為準(zhǔn),安裝前提供隔熱板的安裝圖,確定板與板之間安裝接縫尺寸偏差和容許偏差值,既要保證安裝密封的可靠性,又要使安裝實(shí)際尺寸與設(shè)計(jì)的公稱尺寸、施工預(yù)留的溝槽尺寸相一致。保證接縫可靠和庫體的幾何尺寸和形狀對(duì)的。(6). 冷庫之間、冷庫與地坪之間的管井、縫隙;做隔熱和防水等封堵處理。(7). 冷庫地坪隔熱層的敷設(shè),冷庫地坪隔熱層的厚度≥100mm。地坪使用帶保溫的復(fù)合材料,詳細(xì)做法是先在地面做兩層防水,在防水上側(cè)鋪設(shè)保溫地板,在地板上側(cè)做C30的混凝土,鋼筋為Φ12mm規(guī)格600X600。隔熱地坪的做法見設(shè)計(jì)圖。(8). 庫體頂棚的吊裝點(diǎn)與砼構(gòu)造連接的吊點(diǎn)的構(gòu)造采用措施減低“冷橋”效應(yīng)。。(9). 與庫板相連的吊點(diǎn)材料采用導(dǎo)熱系數(shù)較小的材料如尼龍等,同步在庫內(nèi)表面也應(yīng)采用尼龍材料的罩帽將吊點(diǎn)予以遮蓋。(10). 吊點(diǎn)的孔洞處采用聚氨酯現(xiàn)場(chǎng)發(fā)泡材料灌注予以密封處理。3.3.7 冷庫門 冷庫門規(guī)定(1). 冷庫門壁板為拉絲或花紋不銹鋼板,鋼板厚度≥0.8mm,,壁板的厚度等見(3.3.3.2絕熱保溫板內(nèi)外壁板)一節(jié)的規(guī)定。(2). 冷庫門絕熱性能和厚度等技術(shù)指標(biāo)同庫板。(3). 門框?yàn)椤?mm預(yù)制抗扭剛性鋁合金板壓型門框,門框與庫板的縫隙用發(fā)泡聚氨酯填充,表面覆保護(hù)膜,門框與冷庫門之間有密封裝置,其構(gòu)造不應(yīng)有“冷橋”。(4). 所有冷庫門框內(nèi)埋設(shè)有恒溫電加熱裝置,防止門的密封條被凍結(jié),采用電熱時(shí)有電熱保護(hù)和安全措施等裝置。(5). 所有庫門都開閉靈活,輕便,門框及門的自身的密封接觸平面光滑、平整,不會(huì)有翹曲現(xiàn)象,更會(huì)有毛剌或螺絲端頭歪斜、外露不平產(chǎn)生刮、擦現(xiàn)象,保證使密封膠條可以貼實(shí)門框周圍。(6). 冷庫地面與門外地面應(yīng)有斜坡,斜坡長(zhǎng)度為2800mm,不阻礙車輛通行。(7). 冷庫門橡膠密封件需防油、耐老化,不需特殊工具即可以便裝配和更換。(9).冷庫門為電動(dòng)自動(dòng)門,已經(jīng)安裝了門禁管理系統(tǒng)。(10)、庫門已經(jīng)安裝了磁力開關(guān),當(dāng)門關(guān)閉不嚴(yán)時(shí)可報(bào)警。(11)、當(dāng)碰到停電時(shí),庫門內(nèi)側(cè)可以通過逃生裝置輕易打開。(12)庫門上側(cè)安裝了風(fēng)幕。3.3.8 庫體附件(1). 庫內(nèi)裝設(shè)防潮、防爆燈具的高壓鈉照明燈,能在-25℃條件下正常啟動(dòng)工作。燈罩應(yīng)防腐、防酸、防堿,罩面為鋼化玻璃等。(2). 庫內(nèi)燈光照明度滿足貨品進(jìn)出和取存的規(guī)定,地面照度0.5高度>300lx。(3). 冷庫內(nèi)所有裝置、設(shè)備均做防腐、防銹處理,但必須無毒、不污染食物、無異味,便于清潔,并不易于滋生細(xì)菌。(4). 凡有管線穿過庫體隔熱板所有孔洞均須做防潮密封和隔熱保溫處理,并使表面光整。(5). 冷庫均設(shè)壓力平衡裝置,以防由于溫度變化時(shí),庫內(nèi)溫差過大導(dǎo)致壓力差過大引起庫體變形。(6). 庫外合適的高度設(shè)置溫度顯示和溫度調(diào)整器等。溫度顯示為L(zhǎng)ED數(shù)字式,顯示精度小數(shù)點(diǎn)后1位。(7). 冷庫合適位置應(yīng)有標(biāo)志,注明冷庫的重要技術(shù)規(guī)格和制造安裝日期。(8). 投標(biāo)人提供的設(shè)備、配件、專用備件及工具必須是全新的,質(zhì)量高,互換性好,有專門包裝及中文或中英文闡明。(9)、庫門口安裝聲光報(bào)警器,以便管理人員使用。3.3.9 蒸發(fā)器(1). 冷庫內(nèi)設(shè)置吊頂式蒸發(fā)器,蒸發(fā)器的容量和形式能有效地冷卻冷庫。蒸發(fā)器的數(shù)量和風(fēng)機(jī)的位置應(yīng)保證庫內(nèi)溫度變化均勻。(2). 冷凍庫和冷藏庫的蒸發(fā)器為熱氣融霜,蒸發(fā)器盤管能承受對(duì)應(yīng)的排氣壓力。每個(gè)冷間需一臺(tái)或以上蒸發(fā)器且不應(yīng)同步除霜。(3). 西谷提供的蒸發(fā)器/風(fēng)機(jī)為耐腐蝕長(zhǎng)壽命設(shè)計(jì),質(zhì)量到達(dá)EUROVENT原則規(guī)定。所配置的散熱面積和風(fēng)機(jī)應(yīng)當(dāng)與工作冷庫所規(guī)定的制冷量相匹配。(4). 風(fēng)機(jī)的凝結(jié)水應(yīng)當(dāng)采用管道引出到庫外,排至預(yù)留的排水口。(5). 系統(tǒng)蒸發(fā)器采用冷風(fēng)機(jī),必須為吊頂型。風(fēng)扇電機(jī)為施樂百,質(zhì)量到達(dá)EUROVENT原則規(guī)定(6). 冷庫吊頂式冷風(fēng)機(jī)的技術(shù)規(guī)格數(shù)據(jù);序號(hào)項(xiàng)目參數(shù)備注1型號(hào)BMT259H構(gòu)造和用料2型式商用中溫冷風(fēng)機(jī)3制造廠名稱美國(guó)西克4重要規(guī)格熱氣融霜熱氣融霜5原則工況時(shí)蒸發(fā)量C225.8Kw6蒸發(fā)面積(M2)及片距259㎡5mm銅鋁漲壓7風(fēng)機(jī)出口射程25M施樂百8風(fēng)機(jī)出口風(fēng)壓180PA9送風(fēng)量11800m310風(fēng)機(jī)扇頁外徑尺寸550MM11風(fēng)機(jī)的電功率370KW12冷風(fēng)機(jī)的工作噪音(dB)68Db13外形尺寸mm2890X3200*54514參照重量200Kg3.3.10 冷媒管路系統(tǒng)3.3.10.1 管道系統(tǒng)基本設(shè)計(jì)壽命≥,管道除考慮承受壓力和溫度變化外,已經(jīng)需考慮腐蝕、磨損、震動(dòng)等原因的影響。3.3.10.2 材料:主干管路、支路采用無縫銅管,制冷管液管、吸入管、排出管為銅管,管線為釬焊。所有管路的壁厚必須滿足最大工作壓力且按照承壓原則提供,留有足夠的安全系數(shù)。3.3.10.3 材料序號(hào)項(xiàng)目規(guī)格備注1冷媒管1.1材料銅管1.2直徑按需配置1.3壁厚>1.0mm2絕熱層閉孔泡沫管型2.1厚度≥20mm按照實(shí)際需要加厚2.2耐火等級(jí)≥B12.3保溫材料導(dǎo)熱系數(shù)≤0.037W/m?k3.3.10.4 根據(jù)自己的技術(shù)和經(jīng)驗(yàn)對(duì)不一樣管段選擇合適的管道直徑,在保證制冷、輸送、防止堵塞的前提下,減少噪音和提高管道的壽命。3.3.10.5 管道連接:管道連接方式采用焊接方式,在合適的位置設(shè)置可檢修的接頭,其中管道與閥門、調(diào)整裝置等處連接采用可拆卸式連接,以便此后維護(hù)時(shí)可以檢修拆卸和更換閥門,管道的連接裝置必須保證系統(tǒng)的密閉性,且通過檢漏。焊接時(shí)管道內(nèi)部通上0.1MPA的氮?dú)夥乐寡趸?.3.10.6 泄漏控制:管道系統(tǒng)設(shè)計(jì)、安裝以及運(yùn)行中都具有很好的密閉性,杜絕泄漏。整體管道采用高壓氮?dú)獗?8小時(shí),壓力為2.5MPA。3.3.10.7 管道全長(zhǎng)使用絕熱材料保護(hù),保溫層外部用不燃材料包復(fù)保護(hù),外部保護(hù)層具有一定的強(qiáng)度防止保溫材料被損壞。3.3.10.8 柔性接頭選用不銹鋼蛇形管防護(hù),接頭安裝后應(yīng)進(jìn)行密封測(cè)試。3.310.9 所有的冷媒管道使用橋架承托,包括管井中和垂直架設(shè)的管道??紤]管道的固定和減震措施,管道在不一樣工作狀態(tài)熱脹冷縮等變化的賠償,管道安裝滿足冷庫、制冷等國(guó)家、行業(yè)原則有關(guān)條款的規(guī)定。管道外部使用合適的顏色標(biāo)示,表達(dá)冷媒管液體/氣體流動(dòng)方向和管道的類型。3.3.10.10 控制和供電電纜不會(huì)與冷媒管共橋架敷設(shè)。當(dāng)電纜需要穿管敷設(shè)時(shí),導(dǎo)線填充率≤50%,導(dǎo)線管需采用防腐蝕的金屬線管。外部清晰的標(biāo)示出控制或者供電電纜(可用文字或符號(hào))。3.3.11 制冷系統(tǒng)的安裝3.3.11.1 制冷系統(tǒng)的設(shè)備安裝、調(diào)試嚴(yán)格遵守中國(guó)國(guó)標(biāo)《制冷設(shè)備安裝工程施工及驗(yàn)收規(guī)范》(GB50274-98)或與此原則相稱的原則。3.3.11.2 選用的制冷設(shè)備、壓力容器及重要元件等均應(yīng)有產(chǎn)品質(zhì)量檢查合格證,如:制冷壓縮機(jī)組、中間冷卻器、冷風(fēng)機(jī)及電子膨脹閥、溫度、壓力表等均應(yīng)有制造廠的出廠的質(zhì)量檢查合格證或認(rèn)證許可。3.3.11.3 制冷系統(tǒng)、輔助系統(tǒng)等各管路、壓力表、閥門等均應(yīng)完好無損,安裝排列整潔、牢固、密封可靠無泄漏。有保溫規(guī)定的部位,均有隔熱保溫措施,其保溫層厚度保證表面無結(jié)露現(xiàn)象。并考慮安裝檢修所需空間尺寸。33.11.4 制冷系統(tǒng)的管路安裝符合原則、規(guī)范規(guī)定,認(rèn)真清理排污、壓力試驗(yàn),抽真空、干燥處理及事后更換干燥劑均嚴(yán)格遵守規(guī)范。3.3.11.5 每套冷風(fēng)機(jī)的各管路、配件、閥門等的安裝均完好無損、牢固并排列整潔;連接處應(yīng)密封、無泄漏。各類閥門均保證即無外漏也無內(nèi)漏、運(yùn)行可靠。第4節(jié) 冷庫地面4.1 工作范圍冷庫地坪隔熱層的敷設(shè),冷庫地坪隔熱層的厚度100mm。地坪使用帶保溫的復(fù)合材料,詳細(xì)做法是先在地面切割出填裝發(fā)熱絲的細(xì)槽,填充發(fā)熱絲后,再做兩層防水,在防水上側(cè)鋪設(shè)保溫地板,在地板上側(cè)鋪2.5mm壓花鋼板。隔熱地坪的做法見設(shè)計(jì)圖。在干燥的水泥地坪上側(cè)做環(huán)氧金剛砂地面,保證清潔和耐磨。滿足衛(wèi)生、耐磨、防水、抗壓等規(guī)定。4.2 地面承載規(guī)定4.2.1 冷庫在施工時(shí)留有伸縮縫,考慮熱脹冷縮的影響,防止降溫后地面收縮導(dǎo)致縫隙和漏水,防止冷庫停用后地面膨脹產(chǎn)生變形凹凸不平、翹曲、空鼓等。4.2.2 冷庫下的保溫層采用防水措施,防止保溫材料進(jìn)水后保溫性能的下降。此外,保溫材料可以承受冷庫內(nèi)裝載貨品的載荷,防止壓縮后減少保溫性能。下方保溫體已經(jīng)安裝了帶保溫性能的塑性支架。4.3 冷庫工作溫度分組4.3.1 溫度分組序號(hào)冷庫溫度分組數(shù)據(jù)備注1中溫組0℃~5℃冷藏、保鮮庫、2低溫組-18℃~-21℃冷凍庫4.4 冷庫地面建筑預(yù)留和層次4.4.1 產(chǎn)品認(rèn)證(1). 產(chǎn)品必須符合中國(guó)衛(wèi)生規(guī)定,其殘留物、揮發(fā)物等滿足貨品安全規(guī)定。(2). 產(chǎn)品必須有中國(guó)或美國(guó)或歐洲有關(guān)行業(yè)的認(rèn)或者同等認(rèn)證。4.4.2 功能規(guī)定(1). 無污點(diǎn),無粉塵,無接縫,易維護(hù)保養(yǎng),微生物不易生存,高防腐,耐沖擊。(2). 可以使用清潔劑或殺菌劑清洗(3). 不一樣庫溫的聚氨酯混凝土面層可以采用不一樣的厚度和配比,中溫組最低工作溫度-5℃,低溫組最低溫度-20℃或如下。(4). 規(guī)定完畢后的冷庫地面與建筑平面有坡度,冷庫地面誤差≤±3mm(平均值)。(5). 不采用不透汽材料作為底涂產(chǎn)品,防止地面水汽無法滲透出現(xiàn)空鼓。(6). 踢腳線高度50mm以上,轉(zhuǎn)角是圓角,且半徑≥10mm,同步平面與圓角平滑過渡,圓角與庫板,圓角與地面的過渡不能有裂縫、凹凸不平或不持續(xù)的連接。(7). 考慮冷庫地面的熱脹冷縮,不管是常溫或者低溫,地面滿載或者無負(fù)荷,地面與庫板的結(jié)合處都不容許出現(xiàn)縫隙或者漏水狀況發(fā)生。(8). 有關(guān)增強(qiáng)層的伸縮縫形式和寬度等,西谷根據(jù)自己的技術(shù)和經(jīng)驗(yàn)決定。4.4.3 施工:冷庫地面各層的施工由本項(xiàng)目承包商西谷總負(fù)責(zé)。第5節(jié) 電氣系統(tǒng)5.1 基本規(guī)定5.1.1 電氣系統(tǒng)設(shè)計(jì)選用的設(shè)備、元件等都要滿足中國(guó)的供電原則。5.1.2 電氣線路有完善的保護(hù)裝置。同樣,照明用電及低壓安全電壓的電加熱裝置用電都要分別設(shè)置電氣保護(hù)裝置,保證用電設(shè)備及人身安全,。5.1.3 制冷壓縮機(jī)組裝有高壓、低壓、壓差、斷水、過載電流、欠電壓、過電壓、斷相等完善的自動(dòng)保護(hù)裝置。三相交流電機(jī)均設(shè)斷相保護(hù)器和斷相報(bào)警器。5.1.4 設(shè)備選用的電氣設(shè)備及電氣裝置或電氣元件構(gòu)造完善,性能可靠、安全,使用以便。5.1.5 采用的電氣元件均具有防潮、抗腐能力。安裝在室外的電氣開關(guān)等要帶防水、防撞的保護(hù)裝置。冷風(fēng)機(jī)要設(shè)故障報(bào)警器。冷庫門均設(shè)防撬、漏關(guān)報(bào)警裝置。5.1.6提供電氣系統(tǒng)接線圖及電氣控制系統(tǒng)圖,并標(biāo)注選用的電氣設(shè)備、元件的型號(hào)和規(guī)格見附圖。5.1.7 冷庫的照明燈采用220V電壓耐低溫高壓鈉燈。在使用溫度條件下,壽命>小時(shí)。照明隨冷庫配套提供。(燈光布局見附圖)5.1.8 庫內(nèi)設(shè)置的電氣開關(guān),裝設(shè)于使用以便、安全的位置,并有防護(hù)罩。5.2 接地5.2.1 所有電氣設(shè)備都要按照中國(guó)國(guó)標(biāo)規(guī)定安裝設(shè)備接地導(dǎo)線接地。西谷負(fù)責(zé)對(duì)所有本項(xiàng)目的設(shè)備防靜電,防干擾的接地、設(shè)備的安全接地、信號(hào)接地線工作,接線點(diǎn)與總承包商和設(shè)計(jì)單位就接合處的問題協(xié)調(diào)處理。5.3 供電接電位置5.3.1 冷庫蒸發(fā)器、風(fēng)扇等、照明等供電接點(diǎn)就近接入預(yù)留的配電箱。5.3.2 樓頂制冷機(jī)組和室外冷凝器機(jī)組供電接入機(jī)房預(yù)留的供電柜下樁,機(jī)組、室外冷凝器等系統(tǒng)內(nèi)部所需的分路供電開關(guān)柜等由西谷提供。5.4 電纜和連接5.4.1 工作范圍:由預(yù)留的供電點(diǎn)至設(shè)備控制箱/柜、直到設(shè)備用電裝置的所有接線。有關(guān)這些接線所需材料接線、電纜、接線槽、導(dǎo)管、橋架和安裝等列入西谷的工作范圍,有關(guān)的材料、安裝費(fèi)用已經(jīng)包括在總價(jià)中。5.4.2 電氣線路設(shè)計(jì)按照GBJ72-《冷庫設(shè)計(jì)規(guī)范》、GB50054-95《低壓配電設(shè)計(jì)規(guī)范》及GB50254—96《電氣裝置安裝工程低壓電器施工及驗(yàn)收規(guī)范》執(zhí)行。5.4.3 電纜材料:電纜和電線類型由投按照需求和中國(guó)國(guó)標(biāo)規(guī)定選擇并確定所需的電纜種類,所有的電纜和導(dǎo)線采用阻燃、低煙、無毒型。其選材、安裝符合中國(guó)國(guó)標(biāo)或等效原則的規(guī)定。5.4.4 所有的供電電纜、導(dǎo)線、控制線、通訊電纜(光纖除外)使用銅芯導(dǎo)線作為載體。5.4.5 導(dǎo)體的截面積和載流量以保證制冷機(jī)組的主電機(jī)負(fù)載電壓降不超過1%,且單位載流量要該滿足中國(guó)國(guó)標(biāo)的規(guī)定。5.4.6 所有電力、控制和通訊線纜,包括低壓電纜,都密封在硬金屬管道、金屬軟管或電纜橋架之中。電纜等走線需使用電纜架、匯流線槽、導(dǎo)線管等支撐,不許隨意在設(shè)備或建筑空間亂繞或拖地散亂接線等,所有離散的接線必須妥善綁扎并加以固定。接至設(shè)備移動(dòng)部件或震動(dòng)設(shè)備的接線需使撓性軟管。5.4.7 連接所需要的材料和多種連接設(shè)施、配線箱、架、柜、管、線材、電纜、橋架、導(dǎo)管、配電箱(盒)、插座等等由西谷負(fù)責(zé)。其中有關(guān)安全接地線、信號(hào)接地線等與本建筑內(nèi)通訊、監(jiān)視、等其他系統(tǒng)有連接關(guān)系的布線由承包商向承擔(dān)本建筑電氣設(shè)計(jì)和電氣安裝的承包商互相協(xié)調(diào)。5.4.8 對(duì)于必須屏蔽的信號(hào)線或電磁輻射波也許干擾附近其他系統(tǒng)電子設(shè)備工作的線路由西谷采用措施并負(fù)責(zé)屏蔽。遙測(cè)庫溫的傳感導(dǎo)線,選用屏蔽導(dǎo)線,防止外界干擾。所有電纜線路設(shè)計(jì)和安裝要符合原則(GB、ISO、IEC)原則,且滿足中華人民共和國(guó)國(guó)標(biāo)有關(guān)電氣設(shè)備安裝和安全等規(guī)定。所有電纜線路等考慮防潮、防鼠害等。5.4.9 所有連接點(diǎn)、配線點(diǎn)等需要與安裝圖紙一致的標(biāo)識(shí)便于調(diào)試維修。多種設(shè)備及設(shè)備間的供配電接線、通訊接線、控制接線、網(wǎng)絡(luò)接線等走線有清晰的標(biāo)識(shí)如;信號(hào)線、數(shù)據(jù)傳播線、動(dòng)力線等。在配線接點(diǎn)處加貼標(biāo)簽或護(hù)套標(biāo)識(shí),并與圖紙所采用的標(biāo)識(shí)5.5 電纜護(hù)套管和線槽橋架5.5.1 控制電纜管要按照國(guó)家有關(guān)原則選擇和安裝,控制電纜護(hù)套管采用鍍鋅金屬管,電纜橋架采用鍍鋅金屬線槽,電線填充率≤50%5.5.2 控制電纜管和電纜線槽柱距較大,考慮合適的吊裝點(diǎn),防止橋架自重引起的下垂。當(dāng)穿越防火墻或者樓板時(shí),按照消防規(guī)范進(jìn)行封堵。5.6 控制箱柜5.6.1 控制箱和操作面板等安裝位置邀便于維護(hù)維修。開關(guān)、按鈕、指示燈和燈泡等控制元器件易于更換,合理保護(hù)以免受到物理損壞。按鈕和指示燈安裝在便于操作和查看的位置。5.6.2 操作面板、控制按鈕,開關(guān)等采用中文、中英文對(duì)照或圖形符號(hào)闡明,明確標(biāo)識(shí)各操作開關(guān)、按鈕、指示燈等功用。供有重要操作指令和電氣控制電路原理圖和接線圖的標(biāo)牌。5.6.3 控制箱內(nèi)設(shè)置供檢修使用的電氣、通訊等接口插槽或插座。接口明顯的標(biāo)識(shí)其電壓等級(jí)或類型。控制柜內(nèi)設(shè)置檢修日光燈并附開關(guān)。5.6.4 控制箱及內(nèi)部控制裝置(接觸器、空氣斷路器、熔斷器、繼電器、開關(guān)、按鈕等和接線方式、電氣接地、信號(hào)接地、安全接地等)符合工業(yè)原則。5.6.5 對(duì)處在設(shè)備運(yùn)轉(zhuǎn)區(qū)而無獨(dú)立機(jī)箱或機(jī)柜的裸露電氣元件、控制、通訊等電路單元,搜集于控制箱內(nèi)。5.6.6 設(shè)備自配由電源引入制冷系統(tǒng)的的抗干擾、隔離裝置。5.6.7 現(xiàn)場(chǎng)溫度的監(jiān)測(cè)和監(jiān)控(1). 各冷庫內(nèi)設(shè)置溫度監(jiān)測(cè)裝置(2點(diǎn)或以上),冷庫內(nèi)測(cè)溫點(diǎn)要安頓在具有代表性位置,并將溫度以數(shù)字信號(hào)的格式反饋給控制系統(tǒng)。探頭為活動(dòng)型,有5米的延長(zhǎng)線可以自由活動(dòng)。(2). 庫溫測(cè)量?jī)x表:帶微處理器庫溫控制器,溫度傳感器,并與制冷集中控制系統(tǒng)接口。(3). 庫房外部(門口附近)設(shè)置數(shù)字式庫溫調(diào)整器和顯示裝置,便于使用人員隨時(shí)理解溫度的狀況,調(diào)整溫度設(shè)定。(4). 溫度顯示為數(shù)字直讀方式,顯示位數(shù)3位或以上,小數(shù)點(diǎn)后顯示1~2位。顯示屏件應(yīng)使用LED(藍(lán)色、綠色,紅色),應(yīng)能在3米外清晰的讀數(shù)。對(duì)于不一樣的控制和狀態(tài)應(yīng)采用不一樣顯示顏色加以區(qū)別。如溫度超限采用紅色,并提供聲音報(bào)警信號(hào)。(5). 溫度調(diào)整單位為度,最小設(shè)定增量為0.1度。5.6.8 控制和集中監(jiān)控:(1). 冷庫系統(tǒng)配置獨(dú)立控制系統(tǒng),具有自動(dòng)調(diào)整各庫房溫度和顯示溫度的功能。自動(dòng)監(jiān)視、調(diào)整、控制壓縮機(jī)組運(yùn)行狀態(tài)的功能。(2). 監(jiān)控系統(tǒng)可以隨時(shí)觀測(cè)各庫房的溫度狀況,理解、紀(jì)錄目前溫度與設(shè)定溫度的偏差。具有溫度上限、下限報(bào)警功能。自動(dòng)啟動(dòng)或停止冷庫風(fēng)機(jī)的運(yùn)行。自動(dòng)調(diào)整各庫房冷媒的供應(yīng)。(3). 冷庫蒸發(fā)器是由電控膨脹閥、蒸發(fā)器回風(fēng)探頭、蒸發(fā)器出風(fēng)探頭,化霜探頭等控制?;仫L(fēng)探頭和出風(fēng)探頭取庫房平均溫度并通過控制系統(tǒng)調(diào)整電子膨脹閥的啟動(dòng)度?;筋^控制冷庫的化霜時(shí)間和化霜的溫度。(4).操作人員可在控制顯示裝置上隨時(shí)理解系統(tǒng)的多種運(yùn)行參數(shù),隨時(shí)人工干預(yù)系統(tǒng)的運(yùn)行、調(diào)整設(shè)備的運(yùn)行參數(shù)各(5).系統(tǒng)要能提供完善的報(bào)警功能(聲光指示),具有拒絕錯(cuò)誤操作的功能。報(bào)警系統(tǒng)能與值班手機(jī)聯(lián)動(dòng)短信報(bào)警。 (6). 系統(tǒng)具有設(shè)置數(shù)據(jù)存儲(chǔ)的能力,至少能存儲(chǔ)7天以上的運(yùn)行數(shù)據(jù)備查。其中48小時(shí)以內(nèi)各庫房的溫度必須能以5分鐘的間隔存儲(chǔ)3天以上.數(shù)據(jù)存儲(chǔ)使用USB與電腦連接,可自動(dòng)存儲(chǔ)設(shè)備運(yùn)轉(zhuǎn)記錄一年以上.(7). 系統(tǒng)配置UPS備用電源供應(yīng)。五.工程實(shí)行規(guī)定第1節(jié) 設(shè)計(jì)及技術(shù)聯(lián)絡(luò)1.1 系統(tǒng)深化設(shè)計(jì)1.1.1 西谷預(yù)留足夠的時(shí)間在雇主指定的地點(diǎn)(現(xiàn)場(chǎng)或雇主指定的地點(diǎn))召開系統(tǒng)的設(shè)備深化設(shè)計(jì)審查會(huì)議,以評(píng)審設(shè)備系統(tǒng)深化設(shè)計(jì)的最終止果與否符合客戶的規(guī)定。1.1.2 客戶也可按自己的判斷決定在西谷召開會(huì)議。西谷負(fù)責(zé)在召開會(huì)議之前兩周提供會(huì)議中的評(píng)審材料和議程。系統(tǒng)設(shè)計(jì)審定會(huì)議的與會(huì)各方包括:西谷代表、客戶和/或有關(guān)的項(xiàng)目代表,并報(bào)經(jīng)客戶同意。1.1.3 西谷在文獻(xiàn)中提交在工程現(xiàn)場(chǎng)以及進(jìn)行設(shè)計(jì)審定及技術(shù)聯(lián)絡(luò)會(huì)的詳細(xì)計(jì)劃(包括與設(shè)計(jì)、安裝單位的技術(shù)聯(lián)絡(luò)工作),供客戶同意,客戶有權(quán)變更承包商所提交的計(jì)劃。1.2 技術(shù)聯(lián)絡(luò)和施工協(xié)調(diào)1.2.1 西谷指定授權(quán)代表參與與本項(xiàng)目有關(guān)的設(shè)計(jì)聯(lián)絡(luò)會(huì)議和施工協(xié)調(diào)會(huì)議。所有的技術(shù)聯(lián)絡(luò)必須事先準(zhǔn)備好技術(shù)聯(lián)絡(luò)文獻(xiàn),技術(shù)聯(lián)絡(luò)形成的意見必須通過雙方匯簽,并經(jīng)客戶同意。1.2.2 有關(guān)技術(shù)接口聯(lián)絡(luò),除計(jì)劃規(guī)定的時(shí)間外,在互相配合的雙方碰到爭(zhēng)議的技術(shù)問題時(shí),需要及時(shí)的向客戶發(fā)出申請(qǐng),以便客戶安排各方的協(xié)調(diào)會(huì)議。1.2.3 西谷應(yīng)在協(xié)議生效后10天內(nèi)向建筑設(shè)計(jì)方提出冷庫系統(tǒng)的通風(fēng),地面,墻壁,采光、供電(用電總量、功率因數(shù)、負(fù)荷系數(shù))等規(guī)定。提出需要各方面配合的規(guī)定。以便供客戶安排設(shè)計(jì)聯(lián)絡(luò)計(jì)劃。此外還需提出;基礎(chǔ)預(yù)埋件圖紙、開槽、開孔、通道規(guī)定及有關(guān)闡明,并提供特殊零件部件,供土建施工單位預(yù)埋。任何需要在建筑承重構(gòu)造和節(jié)點(diǎn)內(nèi)的挖掘、開槽、開孔,在墻壁、梁、地板或其他構(gòu)造的所有溝槽和通道必須在施工圖上標(biāo)出,并交客戶同意。1.2.4 西谷要及時(shí)向客戶確認(rèn)與各冷庫系統(tǒng)配合的技術(shù)數(shù)據(jù),向設(shè)計(jì)方確認(rèn)各專業(yè)配合的技術(shù)規(guī)定,假如由于西谷的疏忽導(dǎo)致遺漏或沒有提出需求或者提出規(guī)定超過規(guī)定的時(shí)限,則由承西谷自行負(fù)責(zé)工、料并完畢接入,由此產(chǎn)生的費(fèi)用由西谷承擔(dān)。假如由于西谷提出資料錯(cuò)誤并導(dǎo)致對(duì)方或者多方(建筑、供電、其他系統(tǒng))產(chǎn)生施工修改,西谷不僅規(guī)定承擔(dān)自己修改的費(fèi)用,并且還要承擔(dān)其他方產(chǎn)生的修改費(fèi)用。1.2.5 西谷協(xié)調(diào)與其他各方的工作之間的進(jìn)度和結(jié)合面。協(xié)調(diào)獲取與有關(guān)的承包商的計(jì)劃和工作進(jìn)度表并將其納入自己的工作進(jìn)度表中。假如由于西谷直接/間接的行為或疏忽而破壞了其他承包商的工作,則要西谷修復(fù)這種破損并予以賠償。1.3 生產(chǎn)廠商、供應(yīng)商1.3.1 西谷向雇主提供包括所有生產(chǎn)廠商或供應(yīng)商在內(nèi)的清單供審批。在任何狀況下都必須通過雇主的同意才能指定和變更生產(chǎn)廠商或供應(yīng)商。生產(chǎn)廠商或供應(yīng)商清單還必須包括指定生產(chǎn)廠商。1.3.2 西谷將對(duì)其所有生產(chǎn)廠商或供應(yīng)商負(fù)所有責(zé)任,所有生產(chǎn)廠商或供應(yīng)商都要服從本協(xié)議和本技術(shù)規(guī)范。1.3.3 當(dāng)客戶召開的會(huì)議波及分包供應(yīng)商執(zhí)行的工作時(shí),客戶可以通過西谷規(guī)定供應(yīng)商的關(guān)鍵人員代表出席這個(gè)會(huì)議。然而,在任何狀況下,西谷均必須指派其正式代表出席。第2節(jié) 關(guān)鍵設(shè)備工廠檢查2.1 西谷有權(quán)在貨品發(fā)運(yùn)前的任何合適的時(shí)間訪問制造商,監(jiān)督對(duì)協(xié)議規(guī)定提供的所有設(shè)備性能進(jìn)行的檢測(cè)。檢測(cè)工作假如超過了西谷的能力,西谷安排到有檢測(cè)條件的其他場(chǎng)所或委托有對(duì)應(yīng)資質(zhì)的第四方(指除雇主、承包商、制造商以外的另一方)進(jìn)行,檢測(cè)工作的任何變化都要得到客戶的書面確認(rèn),假如某些設(shè)備是在其他場(chǎng)所制造和檢測(cè)時(shí),承包商應(yīng)替客戶代表辦理進(jìn)入現(xiàn)場(chǎng)的手續(xù)并親自陪伴。2.2 客戶在制造廠的檢查并不由此而解除和減輕承執(zhí)西谷協(xié)議所承擔(dān)的任何責(zé)任,也不作為客戶的驗(yàn)收。2.3 當(dāng)設(shè)備在中國(guó)關(guān)鍵設(shè)備工廠檢查時(shí),西谷應(yīng)提前二周書面告知客戶;當(dāng)設(shè)備在國(guó)外關(guān)鍵設(shè)備工廠檢查時(shí),西谷應(yīng)提前2個(gè)月書面告知雇主,并協(xié)助辦理有關(guān)簽證手續(xù)。假如在規(guī)定的時(shí)間內(nèi)客戶代表不到場(chǎng),工作仍可按客戶代表在場(chǎng)的狀況進(jìn)行,并應(yīng)及時(shí)把測(cè)試成果匯報(bào)客戶。費(fèi)用雙方各自承擔(dān)。2.4 如客戶代表有規(guī)定,西谷要解釋關(guān)鍵設(shè)備工廠檢查的一切事項(xiàng),直到雇客戶代表滿意,如不符合本協(xié)議規(guī)定規(guī)定,西谷要按規(guī)定客戶作免費(fèi)改善。由此引起的延誤,不得作為工程延期和增長(zhǎng)費(fèi)用的理由。2.5 西谷根據(jù)ISO等合適的原則或有關(guān)行業(yè)規(guī)定的原則和進(jìn)行測(cè)試,并應(yīng)進(jìn)行客戶認(rèn)為有必要的性能測(cè)試和其他測(cè)試。西谷必須在設(shè)備制造完畢后的兩周內(nèi)將所有分項(xiàng)檢測(cè)和整機(jī)檢查證書和匯報(bào)提交客戶。第3節(jié) 運(yùn)送包裝、到貨開箱及倉儲(chǔ)3.1 基本規(guī)定3.1.1 所有送到現(xiàn)場(chǎng)的設(shè)備、部件均是全新的。它們都應(yīng)根據(jù)有關(guān)原則合適包裝,并予以保護(hù)以防由于多次搬運(yùn)、不會(huì)由于天氣及其他原因而導(dǎo)致?lián)p壞。3.1.2 西谷應(yīng)自行辦理部分派套部件的進(jìn)出口許可證、存儲(chǔ)、保險(xiǎn)、清關(guān)等事宜及與系統(tǒng)、材料、施工設(shè)備、人員到指定場(chǎng)地的運(yùn)送有關(guān)的所有事宜。在設(shè)備移交最終顧客之前,西谷對(duì)所有貨品的延誤、破壞及損失負(fù)責(zé)。3.1.3 承包商要遵守同進(jìn)口貨品有關(guān)的所有法律(包括中國(guó)海關(guān)法),并且應(yīng)當(dāng)履行遵守有關(guān)法律規(guī)定的職責(zé)并承擔(dān)法律和協(xié)議規(guī)定的責(zé)任和費(fèi)用。3.1.4 所有貨品必須放在經(jīng)雇主確認(rèn)的倉儲(chǔ)區(qū)域,承包商負(fù)責(zé)對(duì)應(yīng)的倉儲(chǔ)、運(yùn)送、保險(xiǎn)等。3.1.5 西谷提供的控制設(shè)備及儀器儀表嚴(yán)禁裸裝,必須有防水/防震等結(jié)實(shí)的外包裝,必須按設(shè)備的編號(hào)進(jìn)行裝箱。嚴(yán)禁將需要單獨(dú)裝箱的設(shè)備部件混裝于一種包裝箱中。所有的包裝箱及零部件上必須標(biāo)有與裝箱單一致的中英文或/中文/英文標(biāo)簽編號(hào)(裝箱單為中英文)3.1.6 備件和檢測(cè)設(shè)備、維修工具與設(shè)備分開包裝。這些包裝要適合于儲(chǔ)存。儲(chǔ)存年限應(yīng)在包裝上予以闡明。所有備件應(yīng)加以標(biāo)簽。3.1.7 所有設(shè)備應(yīng)根據(jù)設(shè)備清單按不一樣工程項(xiàng)目分箱包裝,并在外包裝上有明顯的標(biāo)志或指示加以辨別,同步在裝箱清單上也應(yīng)有清晰的標(biāo)識(shí)。3.1.8 西谷提供的設(shè)備所有銘牌、使用指示、警告指示必需有中文或中英文表達(dá)。3.1.9 每項(xiàng)設(shè)備均有制造商家的銘牌,銘牌應(yīng)標(biāo)明品牌、規(guī)格、型號(hào)、產(chǎn)地等,并裝在明顯的地方。3.1.10 設(shè)備抵達(dá)客戶指定現(xiàn)場(chǎng)后,西谷應(yīng)根據(jù)客戶的規(guī)定,派員參與到貨簽收,并作好簽收記錄。設(shè)備和器材符合下列規(guī)定: 包裝及密封良好。 開箱檢查設(shè)備及部件的型號(hào)、規(guī)格等符合協(xié)議及設(shè)計(jì)規(guī)定,設(shè)備無損傷,附件、備件齊全。 產(chǎn)品的到貨資料齊全。 按本章規(guī)定外觀檢查合格。3.1.11 客戶將拒收運(yùn)抵現(xiàn)場(chǎng)的被損壞或有缺陷的或不符合本技術(shù)規(guī)格規(guī)定的任何設(shè)備。在此狀況下,客戶規(guī)定盡快改善設(shè)備質(zhì)量或調(diào)換設(shè)備以保證設(shè)備符合協(xié)議規(guī)定,由此引起的一切經(jīng)濟(jì)損失由西谷負(fù)責(zé)。3.1.12 在冷庫系統(tǒng)移交最終顧客之前,西谷負(fù)責(zé)材料和設(shè)備的保管和保護(hù)工作。第4節(jié) 系統(tǒng)安裝、調(diào)試4.1 假如西谷認(rèn)為客戶已經(jīng)選擇的建筑總承包商或者設(shè)備安裝商可以勝任本系統(tǒng)設(shè)備的安裝工作,或者某些安裝工作可以由其承擔(dān),則闡明有關(guān)的安裝工作量和分工。但安裝所需的材料等仍由西谷負(fù)責(zé)提供,且西谷仍然須承擔(dān)技術(shù)指導(dǎo)和對(duì)系統(tǒng)的安裝負(fù)所有的責(zé)任,客戶有權(quán)對(duì)該部分進(jìn)行選擇。4.2 安裝規(guī)定4.2.1 西谷負(fù)責(zé)由于系統(tǒng)設(shè)備的所有安裝工作,管線連接和安裝、電氣接線工作、所需的開槽、挖洞等土木工作和表面的恢復(fù)工作。負(fù)責(zé)整個(gè)系統(tǒng)設(shè)備的安裝并負(fù)責(zé)系統(tǒng)的調(diào)試及試運(yùn)行,負(fù)責(zé)向質(zhì)量監(jiān)督部門辦理報(bào)監(jiān),安裝、調(diào)試。西谷按照總承包單位制定的時(shí)間表安排安裝計(jì)劃。4.2.2 在設(shè)備安裝之前,西谷應(yīng)當(dāng)對(duì)設(shè)備安裝部位的土建預(yù)留孔、洞、預(yù)埋件、基礎(chǔ)等尺寸、數(shù)量等與設(shè)備安裝有關(guān)的邊界條件進(jìn)行檢查和確認(rèn),并標(biāo)識(shí)在自己的圖紙上,檢查成果應(yīng)書面告知客戶。在此確認(rèn)后發(fā)現(xiàn)的上述邊界條件問題和由于西谷自行變動(dòng)安裝條件引起的成果應(yīng)由西谷承擔(dān)責(zé)任。4.2.3 西谷應(yīng)在安裝后對(duì)設(shè)備進(jìn)行調(diào)試、現(xiàn)場(chǎng)測(cè)試,以檢查其設(shè)計(jì)制作、操作性能和功能等方面的狀況,西谷提供所有調(diào)試和試運(yùn)行所需的工具、材料、儀器及勞務(wù)。配合安裝、調(diào)試,試運(yùn)行所需的工具、材料、儀器及勞務(wù)均由西谷負(fù)責(zé)準(zhǔn)備。4.2.4 工程所需要的臨時(shí)設(shè)施及所需的設(shè)備的產(chǎn)品保護(hù)、工作設(shè)施、工作照明、防護(hù)、安裝腳手、圍欄、警告標(biāo)志和守護(hù)人員等由西谷負(fù)責(zé)。西谷與各有關(guān)系統(tǒng)的承包商配合完畢系統(tǒng)的調(diào)試以及技術(shù)規(guī)格文獻(xiàn)規(guī)定的功能。在配合過程中如出現(xiàn)分歧和矛盾,必須服從客戶的協(xié)調(diào),并不得以此為借口遲延工期、增長(zhǎng)費(fèi)用。4.2.5 客戶保留對(duì)承包商駐現(xiàn)場(chǎng)主管和工作人員人選的審查權(quán),若客戶認(rèn)為任何承包商工作人員不能勝任工作、行為不良、違反現(xiàn)場(chǎng)工作制度或野蠻操作、不聽指示、存在安全隱患以及雇主認(rèn)為應(yīng)予調(diào)離的其他原因,客戶有權(quán)祈求更換,西谷應(yīng)立即更換人員,并不得借此規(guī)定賠償和遲延工期。4.2.6 西谷必須在接到告知客戶后7天內(nèi)派員抵達(dá)現(xiàn)場(chǎng),在沒有得到客戶容許前,西谷不能更換或撤走工作人員。4.2.7 西谷商須派遣足夠人數(shù)的、合格的工程師、技術(shù)人員和技術(shù)工人進(jìn)行本項(xiàng)目工程的施工,其重要人員必須有5年以上工作經(jīng)驗(yàn)和類似工程經(jīng)驗(yàn),以保證工程按期、按質(zhì)完畢。4.2.8 西谷須按客戶、總承包(或安裝承包)代表的規(guī)定定期參與現(xiàn)場(chǎng)會(huì)議和有關(guān)專題會(huì)議,積極配合客戶工作,圓滿處理安裝、調(diào)試、試運(yùn)行中的所有問題。4.2.9 西谷會(huì)積極服從和配合項(xiàng)目總承包單位或安裝主承包單位以及監(jiān)理單位的工程進(jìn)度管理及現(xiàn)場(chǎng)文明施工管理,隨時(shí)對(duì)本項(xiàng)目的工作做合適的安排和調(diào)整,在設(shè)備安裝前,根據(jù)總承包單位的工程進(jìn)度規(guī)定,西谷制定設(shè)備安裝計(jì)劃表,經(jīng)客戶同意,以保證整個(gè)工程建設(shè)按期完畢。4.2.10 西谷在進(jìn)駐現(xiàn)場(chǎng)前2周,應(yīng)與總承包商簽訂安全施工責(zé)任保證書,并提交施工組織方案、進(jìn)場(chǎng)施工申請(qǐng)匯報(bào)等資料,并在工程實(shí)行中,必須無條件地接受項(xiàng)目總承包或安裝主承包單位、監(jiān)理單位的管理與檢查,并執(zhí)行監(jiān)理單位的指令,保證工程質(zhì)量和安裝進(jìn)度能滿足總的質(zhì)量規(guī)定和進(jìn)度規(guī)定。4.2.11 工程施工和設(shè)備安裝所有進(jìn)駐現(xiàn)場(chǎng)的施工人員必須是具有有關(guān)資格的正式員工。假如在工程施工和設(shè)備安裝過程中,西谷需要增長(zhǎng)其他施工隊(duì)伍或人員,必須征得客戶同意。假如西谷私自派遣資格能力不符合雇重規(guī)定的施工隊(duì)伍或施工人員進(jìn)駐現(xiàn)場(chǎng)施工,由此引起的一切后果均由西谷承擔(dān)責(zé)任。4.2.12 西谷在設(shè)備安裝、調(diào)試、試運(yùn)行期間,必須確定現(xiàn)場(chǎng)技術(shù)人員,負(fù)責(zé)與客戶聯(lián)絡(luò)有關(guān)工作,溝通語言為中文。合格的技術(shù)指導(dǎo)人員必須至少有安裝和調(diào)試同類設(shè)備3年以上的工作經(jīng)驗(yàn),西谷要向客戶提供派駐現(xiàn)場(chǎng)技術(shù)指導(dǎo)人員的資質(zhì)和工作簡(jiǎn)歷資料?,F(xiàn)場(chǎng)技術(shù)人員在沒有得到雇主容許前,承包商不能更換或撤走任何一種技術(shù)指導(dǎo)人員。若客戶認(rèn)為不合格,西谷必須按照雇重規(guī)定更換。4.2.13 在工程施工和設(shè)備安裝過程中,西谷要做好設(shè)備的產(chǎn)品保護(hù)以及對(duì)應(yīng)措施。西谷不得損壞土建構(gòu)造和已裝修完畢的墻面、地面、吊頂和其他已安裝的設(shè)備和系統(tǒng),不得損壞其他西谷負(fù)責(zé)的設(shè)備和系統(tǒng),否則,由此引起的替代或修補(bǔ)由西谷承擔(dān)。4.2.14 有關(guān)現(xiàn)場(chǎng)工作設(shè)施的敷設(shè)須經(jīng)總承包單位或安裝主承包單位的同意后,在指定的地點(diǎn)和范圍內(nèi)敷設(shè)。所需的臨電、臨水須按總承包單位或安裝主承包單位的管理規(guī)定執(zhí)行。4.3 系統(tǒng)調(diào)試4.3.1 西谷在現(xiàn)場(chǎng)對(duì)設(shè)備系統(tǒng)進(jìn)行調(diào)試、現(xiàn)場(chǎng)測(cè)試,以檢查其設(shè)計(jì)制作、操作性能和功能等方面的狀況,西谷要提供所有調(diào)試和試運(yùn)行所需的工具、材料、儀器及勞務(wù),所有有關(guān)費(fèi)用計(jì)入投標(biāo)總價(jià)。4.4.3.2 西谷應(yīng)在安裝完畢1周之前,向客戶提交調(diào)試、現(xiàn)場(chǎng)測(cè)試的計(jì)劃、程序及登記表格,供客戶同意。并寫明計(jì)劃實(shí)行的每一環(huán)節(jié),該項(xiàng)目中所有系統(tǒng)和設(shè)備的性能均應(yīng)得到證明和顯示。4.3.3 調(diào)試應(yīng)在系統(tǒng)安裝中或安裝完后進(jìn)行。調(diào)試前,有關(guān)部門的提議和規(guī)定均應(yīng)作為調(diào)試及驗(yàn)收規(guī)定的補(bǔ)充。4.3.4 試驗(yàn)及檢查匯報(bào)樣本應(yīng)在調(diào)試開始2周之前報(bào)客戶審批。第5節(jié) 系統(tǒng)驗(yàn)收系統(tǒng)驗(yàn)收按照三階段劃分;第一階段為:“初步驗(yàn)收”、或“有條件驗(yàn)收”第二階段為:“最終驗(yàn)收”---(進(jìn)入質(zhì)量保證期)客戶申明可認(rèn)為部分或整個(gè)系統(tǒng)簽發(fā)驗(yàn)收合格證明。然而,不管是部分系統(tǒng)驗(yàn)收還是有條件驗(yàn)收,客戶有權(quán)按期使用系統(tǒng)的這些部分進(jìn)行運(yùn)行??蛻粼谡麄€(gè)驗(yàn)收過程當(dāng)中有權(quán)在任何時(shí)間對(duì)系統(tǒng)的缺陷進(jìn)行識(shí)別。5.1 測(cè)試和驗(yàn)收原則5.1.1 客戶規(guī)定西谷提供系統(tǒng)的測(cè)試和檢查原則或者企業(yè)原則,并保留采納該原則所有或部分作為測(cè)試和驗(yàn)收條件的權(quán)利。假如該原則中有與中國(guó)現(xiàn)行原則或者招標(biāo)技術(shù)規(guī)定明顯相?;驔_突的地方,則原則中沖突的條款項(xiàng)將不能合用。假如投標(biāo)人不能提供行業(yè)原則或者企業(yè)原則,則招標(biāo)人可以認(rèn)為投標(biāo)人沒有原則根據(jù),而采用國(guó)際上(包括中國(guó))各原則中招標(biāo)人認(rèn)為合用于本項(xiàng)目的條款和較為嚴(yán)格的測(cè)試條件對(duì)系統(tǒng)進(jìn)行全面的測(cè)試和檢查。系統(tǒng)和部件測(cè)試原則的優(yōu)先次序是國(guó)際原則,中國(guó)原則,企業(yè)原則。5.1.2 系統(tǒng)驗(yàn)收以功能考核和重要指標(biāo)測(cè)試為主,前提是西谷已經(jīng)完畢所有自檢并滿足協(xié)議技術(shù)條件的規(guī)定??蛻艨梢赃x擇所有或者部分項(xiàng)目進(jìn)行校核性檢查,假如客戶認(rèn)為系統(tǒng)功能沒有滿足規(guī)定,可以規(guī)定對(duì)所有項(xiàng)目和重要指標(biāo)等進(jìn)行檢測(cè)。所有復(fù)檢測(cè)試和檢查所需的費(fèi)用西谷承擔(dān)。5.2 冷庫的驗(yàn)收(1). 分項(xiàng)檢查的項(xiàng)目:庫體及其多種裝置制冷系統(tǒng)、制冷輔助系統(tǒng)電氣系統(tǒng)控制系統(tǒng)冷庫空庫降溫試驗(yàn)額定庫容降溫試驗(yàn)(2). 冷庫各系統(tǒng)的檢查和運(yùn)行考核冷庫須分項(xiàng)檢查后,再經(jīng)72小時(shí)的持續(xù)穩(wěn)定運(yùn)行后移交客戶驗(yàn)收。(3). 資料和文獻(xiàn)檢查竣工下水系統(tǒng)圖竣工設(shè)計(jì)方案表冷凝機(jī)組安裝竣工圖系統(tǒng)操作手則維修人員培訓(xùn)時(shí)間表及課程安排維修保養(yǎng)范圍竣工設(shè)備清單5.3 初步驗(yàn)收5.3.1 西谷按協(xié)議規(guī)定完畢安裝和調(diào)試后,由西谷向最終顧客提出初驗(yàn)申請(qǐng)。此前,西谷負(fù)責(zé)對(duì)已完畢項(xiàng)目進(jìn)行自驗(yàn),自驗(yàn)結(jié)束后向最終顧客提出初驗(yàn)申請(qǐng),由最終顧客會(huì)同有關(guān)部門進(jìn)行初驗(yàn)。5.3.2 驗(yàn)收條件:只有具有下列條件,最終顧客才進(jìn)行驗(yàn)收工作。(1). 驗(yàn)收前準(zhǔn)備所有準(zhǔn)備工作已經(jīng)完畢,有關(guān)資料已經(jīng)提交(2). 系統(tǒng)設(shè)備準(zhǔn)備就緒。(3). 已經(jīng)準(zhǔn)備好足夠數(shù)量的檢查用物品。(4). 西谷已經(jīng)完畢自檢,按實(shí)際作業(yè)程序持續(xù)運(yùn)行72小時(shí)。5.3.3 驗(yàn)收測(cè)試重要以功能測(cè)試為主,詳細(xì)測(cè)試為輔;西谷要準(zhǔn)備測(cè)試大綱和規(guī)范/記錄備查。5.3.4 假如初步驗(yàn)收發(fā)現(xiàn)系統(tǒng)存在局部缺陷或者部分項(xiàng)目沒有滿足規(guī)定的技術(shù)規(guī)定,最終顧客可以視狀況決定初步驗(yàn)收;①延期初步驗(yàn)收,②有條件驗(yàn)收。5.3.5 客戶可以規(guī)定西谷進(jìn)行整改直至合格,假如西谷整改的時(shí)間不能滿足客戶的營(yíng)運(yùn)計(jì)劃,則雇客戶可以采用“有條件驗(yàn)收”的方式將系統(tǒng)投入試運(yùn)行。沒有通過的部分、瑕疵或者遺留問題不能免除西谷的責(zé)任。此外,最終顧客仍然有權(quán)將該部分投入使用,并由西谷采用一切措施或臨時(shí)措施來保證運(yùn)行的需要。5.3.6 有條件驗(yàn)收將解除西谷對(duì)已經(jīng)簽發(fā)驗(yàn)收合格部分系統(tǒng)安全和保險(xiǎn)的責(zé)任。無論何種狀況下,有條件驗(yàn)收并不免除西谷對(duì)履行協(xié)議或瑕疵表中所規(guī)定的任何或所有剩余工作或?qū)ο到y(tǒng)進(jìn)行完善和維護(hù)的責(zé)任。5.3.7 雖然最終顧客已經(jīng)接受了設(shè)備,假如由于不可接受的成果所導(dǎo)致的人員或者設(shè)備損害出現(xiàn),則最終顧客可以并有權(quán)據(jù)此否認(rèn)本次驗(yàn)收的成果。5.3.8 假如由于西谷的原因?qū)е孪到y(tǒng)不能通過驗(yàn)收,則由其產(chǎn)生的延誤、費(fèi)用等由自行承擔(dān),最終顧客不承擔(dān)任何由此產(chǎn)生的糾紛和費(fèi)用。西谷不能籍此延誤、甚至停止協(xié)議的執(zhí)行或者規(guī)定追加費(fèi)用。5.4 最終驗(yàn)收5.4.1 已投入試運(yùn)行使用15個(gè)工作日,并沒有出現(xiàn)任何問題才能進(jìn)行最終驗(yàn)收。最終驗(yàn)收將釋放西谷對(duì)本協(xié)議有關(guān)責(zé)任??蛻魧㈩C發(fā)最終驗(yàn)收合格證明書。5.4.2 西谷需負(fù)責(zé)對(duì)所供設(shè)備及有關(guān)設(shè)備產(chǎn)品的保護(hù)和清潔工作至項(xiàng)目驗(yàn)收合格且正式運(yùn)轉(zhuǎn)二周后為止,在此期間,系統(tǒng)設(shè)備及有關(guān)設(shè)備的損壞或丟失的費(fèi)用由西谷負(fù)責(zé)。若因承包商原因損壞其他設(shè)備和設(shè)施,西谷須負(fù)責(zé)修理或予以賠償。5.4.3 在預(yù)期最終驗(yàn)收日前,西谷至少要提前10天書面告知最終顧客,表明西谷望在10天內(nèi)獲得最終驗(yàn)收。5.4.4 最終驗(yàn)收的條件為;1). 系統(tǒng)滿足協(xié)議文獻(xiàn)的所有規(guī)定,實(shí)際運(yùn)行的功能和性能以及測(cè)試性能指標(biāo)滿足技術(shù)規(guī)范規(guī)定;設(shè)備設(shè)施的實(shí)際運(yùn)行性能和測(cè)試性能指標(biāo)滿足技術(shù)規(guī)范規(guī)定;已經(jīng)滿足了協(xié)議中所規(guī)定的可用性規(guī)定。沒有任何尚未處理的瑕疵問題。對(duì)所有的設(shè)計(jì)和施工缺陷等狀況進(jìn)行了整改和做出了闡明。因更改缺陷而受影響的所有文獻(xiàn)/手冊(cè)均已經(jīng)被更新,并得到了最終顧客的承認(rèn)。2). 系統(tǒng)成功地接受了15個(gè)工作日試運(yùn)行的考核,運(yùn)行時(shí)性能和功能滿足所有技術(shù)條件以及試運(yùn)行考核計(jì)劃的規(guī)定。性能測(cè)試、功能和運(yùn)行時(shí)出現(xiàn)的問題已被處理至最終顧客滿意。承包商已經(jīng)成功地完畢了試運(yùn)行和支持義務(wù),并得到最終顧客的書面承認(rèn)。3). 所有的技術(shù)文獻(xiàn)、資料、手冊(cè)已經(jīng)移交最終顧客。并且提供了已被承認(rèn)的所有支持文獻(xiàn)。4). 所有的工具\(yùn)備件均已經(jīng)交付給最終顧客。所有由最終顧客購(gòu)置的備件均已經(jīng)被交付。在質(zhì)量保證期內(nèi)用于更換有瑕疵部件的所有備件均已經(jīng)由承包商進(jìn)行了補(bǔ)充和更換。對(duì)所有的備件進(jìn)行了查驗(yàn),并已經(jīng)移交給了最終顧客并得到其承認(rèn)。5.4.5 履約證書質(zhì)保期結(jié)束后,如設(shè)備滿足招標(biāo)文獻(xiàn)的規(guī)定,客戶將向西谷頒發(fā)履約證書。第6節(jié) 售后服務(wù)6.1 基本服務(wù)規(guī)定6.1.1 西谷必須在中國(guó)或者深圳設(shè)有常駐服務(wù)機(jī)構(gòu)或委托技術(shù)服務(wù)機(jī)構(gòu),提供具有當(dāng)?shù)兀ㄉ钲冢┑募夹g(shù)支持和維護(hù)服務(wù)能力、技術(shù)力量和備有足夠備品備件。6.1.2 該機(jī)構(gòu)能處理所有維修和技術(shù)支持服務(wù)。服務(wù)應(yīng)當(dāng)是每天24小時(shí)提供,在接到報(bào)修告知或者電話告知后3小時(shí)內(nèi)趕到現(xiàn)場(chǎng),并持續(xù)進(jìn)行,直至故障排除完全恢復(fù)正常服務(wù)為止。6.1.3 西谷在接受雇主簽發(fā)的“最終驗(yàn)收證書”開始之日,為進(jìn)入交付使用質(zhì)量保證期。質(zhì)量保證期時(shí)間為12個(gè)月,其間由于設(shè)備質(zhì)量原因而導(dǎo)致的損壞,均由西谷負(fù)責(zé)免費(fèi)維修和更換備件。6.1.4 西谷在質(zhì)量保證期內(nèi)保證按客戶的規(guī)定免費(fèi)修理或更換因材料不合格或制造不合格而有缺陷的任何設(shè)備的附件,并賠償客戶由于這些缺陷導(dǎo)致的額外費(fèi)用或損失。在修理之后,西谷應(yīng)將成因、補(bǔ)救措施、完畢修理及恢復(fù)正常的時(shí)間和日期等匯報(bào)給客戶。6.1.5 在質(zhì)量保證期內(nèi),西谷派出有關(guān)專業(yè)技術(shù)人員,每季度訪問顧客一次,指導(dǎo)客戶對(duì)設(shè)備的對(duì)的使用,并對(duì)設(shè)備進(jìn)行檢查和維護(hù)。保修及維修保養(yǎng)期內(nèi),保養(yǎng)包括對(duì)系統(tǒng)設(shè)備作定期檢查、調(diào)校和潤(rùn)滑等。6.1.6 在質(zhì)量保證期結(jié)束時(shí),須由專業(yè)工程師和客戶代表對(duì)整套設(shè)備進(jìn)行一次檢查,任何缺陷必須由西谷負(fù)責(zé)免費(fèi)修理或更換。在修理完畢之后,西谷將缺陷原因、修理內(nèi)容、完畢修理及恢復(fù)正常的時(shí)間和日期等匯報(bào)給客戶。如有缺陷發(fā)生,質(zhì)量保證期應(yīng)對(duì)應(yīng)延長(zhǎng),延長(zhǎng)時(shí)間由雙方協(xié)定。6.1.7 當(dāng)由于設(shè)備設(shè)計(jì)和制造質(zhì)量原因?qū)е碌娜魏螕p傷或損壞,西谷除負(fù)責(zé)修理或更換外,所作更換的材料和零件必須是原廠生產(chǎn)的原則材料和零件。保修期應(yīng)視狀況做自動(dòng)延長(zhǎng)。延長(zhǎng)時(shí)間根據(jù)損壞和更換的狀況雙方確定。西谷應(yīng)保證在產(chǎn)品停產(chǎn)后內(nèi),向最終顧客提供所需的備件。6.2 技術(shù)支持6.2.1 西谷在中國(guó)的常設(shè)服務(wù)機(jī)構(gòu)提供技術(shù)支持,負(fù)責(zé)解答最終顧客使用和維修中的多種問題,負(fù)責(zé)向最終顧客提供最新的技術(shù)資料等。提供電子郵件、技術(shù)支持電話熱線,提供遠(yuǎn)程診斷功能等,隨時(shí)解答使用中碰到的多種問題。6.2.2 西谷在網(wǎng)站為其顧客開放專門的帳戶,容許最終顧客免費(fèi)下載維修和使用資料。6.3 現(xiàn)場(chǎng)技術(shù)服務(wù)6.3.1 西谷在現(xiàn)場(chǎng)的技術(shù)服務(wù)包括設(shè)計(jì)審查、安裝、調(diào)試、試運(yùn)行、考核、培訓(xùn),但不限于這些內(nèi)容,包括必須客戶的其他技術(shù)服務(wù)。6.3.2 西谷指派一名技術(shù)服務(wù)人員作為現(xiàn)場(chǎng)總代表,負(fù)責(zé)協(xié)議范圍內(nèi)的設(shè)備的總技術(shù)指導(dǎo)。西谷必須指定授權(quán)的現(xiàn)場(chǎng)聯(lián)絡(luò)人員定期參與現(xiàn)場(chǎng)會(huì)議,積極配合客戶工作,圓滿處理安裝、調(diào)試、試運(yùn)行中的所有問題。6.3.3 西谷派出的技術(shù)服務(wù)人員,根據(jù)系統(tǒng)的安裝、調(diào)試、試運(yùn)行、驗(yàn)收的規(guī)定,進(jìn)行整機(jī)及其部件安裝質(zhì)量的檢查,并代表西谷擔(dān)協(xié)議規(guī)定的承包商的責(zé)任和義務(wù)。6.3.4 西谷的技術(shù)服務(wù)必須對(duì)的無誤。由于西谷技術(shù)人員不對(duì)的的技術(shù)指導(dǎo),而導(dǎo)致設(shè)備和材料的損失。西谷必須負(fù)責(zé)免費(fèi)修理、更換和補(bǔ)充。6.3.5 西谷技術(shù)人員根據(jù)客戶的總體進(jìn)度安排自己項(xiàng)目的工作計(jì)劃。西谷技術(shù)人員在現(xiàn)場(chǎng)必須填寫工作日志,一式兩份,由雙方現(xiàn)場(chǎng)代表簽字。第7節(jié) 設(shè)計(jì)質(zhì)量保證7.1 設(shè)計(jì)保證內(nèi)容7.1.1 西谷必須對(duì)系統(tǒng)/設(shè)備的設(shè)計(jì)缺陷提供2年保證,時(shí)間從最終驗(yàn)收合格之日起計(jì)算。在保證期內(nèi)發(fā)現(xiàn)設(shè)計(jì)缺陷時(shí),西谷應(yīng)免費(fèi)重新設(shè)計(jì)并更換組件或設(shè)備,以防止同類故障再次發(fā)生。在這種狀況下,必須向客戶提交提議的重新設(shè)計(jì)圖紙和組件供審批。對(duì)更換后的重新設(shè)計(jì)的組件或設(shè)備應(yīng)提供新的保證期。7.1.2 在設(shè)計(jì)保證期內(nèi),假如出現(xiàn)如下狀況之一即認(rèn)為組件或設(shè)備出現(xiàn)設(shè)計(jì)缺陷:(1). 系統(tǒng)功能低于規(guī)定規(guī)定或者系統(tǒng)性能不穩(wěn)定(2). 系統(tǒng)啟機(jī)時(shí)間超過規(guī)定,或者不能執(zhí)行規(guī)定的動(dòng)作(3). 主機(jī)系統(tǒng)漏氣量超過規(guī)定(內(nèi)漏和外漏)。(4). 相似設(shè)備需要頻繁地進(jìn)行計(jì)劃外調(diào)整或其他維護(hù)工作。(5). 組件或子系統(tǒng)不能執(zhí)行其規(guī)定功能(6). 相似設(shè)備頻繁觸發(fā)過載保護(hù)裝置。(7). 相似設(shè)備出現(xiàn)焊接件或連接件松開。(8). 設(shè)備構(gòu)造性損壞。(9). 工作中控制器件或傳感器出現(xiàn)錯(cuò)誤動(dòng)作。(10). 在工作中出現(xiàn)事故或發(fā)現(xiàn)安全隱患危險(xiǎn)。(11). 在保證期內(nèi)發(fā)現(xiàn)不符合規(guī)格規(guī)定或者達(dá)不到規(guī)定的功能規(guī)定。(12). 相似設(shè)備中相似構(gòu)造或設(shè)計(jì)的一種或多種組件發(fā)生三次以上故障。(13). 相似設(shè)備中的消耗性組件出現(xiàn)3次以上計(jì)劃外更換。7.2 保證期限和責(zé)任7.2.1 從在設(shè)計(jì)保證期限內(nèi)發(fā)現(xiàn)設(shè)計(jì)、系統(tǒng)、設(shè)備或材料的任何方面不符合上述保證時(shí),西谷應(yīng)在雇主發(fā)出告知后24小時(shí)內(nèi)執(zhí)行如下糾正措施:1.)確定故障原因。2.)準(zhǔn)備用于闡明提議設(shè)計(jì)修改的圖紙并將其提交給客戶。3.)客戶提出修改規(guī)定或予以同意。4.)按規(guī)定進(jìn)行設(shè)計(jì)修改。5).客戶同意設(shè)計(jì)后,修改同一設(shè)計(jì)缺陷波及的所有組件。7.7.2.2 當(dāng)構(gòu)造、制造或型號(hào)更換時(shí),從采用設(shè)計(jì)修改之日起對(duì)修改后的組件/系統(tǒng)提供新的部件保證期和設(shè)計(jì)保證期。第8節(jié) 技術(shù)培訓(xùn)8.1 西谷派遣人員8.1.1 西谷出的技術(shù)人員,應(yīng)在所提供的產(chǎn)品上具有5年以上的經(jīng)驗(yàn)。派遣人員的簡(jiǎn)歷連同技術(shù)服務(wù)計(jì)劃(包括人數(shù)、天數(shù)、內(nèi)容)等一并提交客戶,客戶有權(quán)規(guī)定更換不合適的派遣人員,在沒有得到客戶容許前,西谷不能更換或撤走任何派遣人員。8.2 培訓(xùn)規(guī)定8.2.1 西谷應(yīng)在系統(tǒng)進(jìn)入運(yùn)行開始前對(duì)客戶的技術(shù)人員和操作人員進(jìn)行理論和實(shí)際操作、維護(hù)等方面的培訓(xùn),并提供有關(guān)培訓(xùn)資料。培訓(xùn)應(yīng)以中文進(jìn)行。技術(shù)培訓(xùn)人員必須流利地掌握手冊(cè)上的語言。并提供中文或中英文對(duì)照的培訓(xùn)手冊(cè)。若培訓(xùn)在國(guó)外進(jìn)行,西谷配置至少一位專業(yè)技術(shù)翻譯。8.2.2 客戶以使用錄音錄像設(shè)備錄下所有的培訓(xùn)課程。所錄材料將用于對(duì)本項(xiàng)目此后的新員工進(jìn)行培訓(xùn)。8.3 現(xiàn)場(chǎng)培訓(xùn)8.3.1 現(xiàn)場(chǎng)課堂培訓(xùn)由客戶提供場(chǎng)所和教室。但西谷應(yīng)當(dāng)至少提前2周告知客戶確切的使用時(shí)間。培訓(xùn)應(yīng)使用中文,若承包商教師不能純熟使用中文,西谷應(yīng)負(fù)責(zé)安排熟悉本專業(yè)技術(shù)的翻譯人員。8.3.2 西谷應(yīng)在設(shè)備安裝完畢后進(jìn)行現(xiàn)場(chǎng)培訓(xùn),安排工程師對(duì)怎樣進(jìn)行設(shè)備的保養(yǎng)、維護(hù)、零件的拆裝更換,怎樣排除故障等進(jìn)行指導(dǎo)和演示,并對(duì)技術(shù)人員進(jìn)行實(shí)際操作培訓(xùn)。8.3.3 西谷還必須為客戶的操作人員安排培訓(xùn)班進(jìn)行培訓(xùn),培訓(xùn)內(nèi)容包括課堂教學(xué)和現(xiàn)場(chǎng)操作兩部分。培訓(xùn)應(yīng)有指導(dǎo)、現(xiàn)場(chǎng)演示等內(nèi)容,可以使受訓(xùn)人員理解應(yīng)用系統(tǒng)及設(shè)備的構(gòu)造、工作原理,并能掌握對(duì)的使用與操作和排除一般故障的技能等。被培訓(xùn)的操作人員將實(shí)際操作系統(tǒng)設(shè)備。應(yīng)使客戶的操作人員到達(dá)如下的目的:a).理解本系統(tǒng)的功能和使用管理措施。b).理解每臺(tái)設(shè)備的性能和對(duì)的操作措施。c).理解安全操作規(guī)程和使用時(shí)必須注意的事項(xiàng)。d).掌握常見故障發(fā)生的原因和排除措施。e).純熟掌握控制室、以及現(xiàn)場(chǎng)等的多種設(shè)備和控制裝置等的使用方法。f).學(xué)會(huì)系統(tǒng)的保養(yǎng)知識(shí)。g).理解系統(tǒng)的安全保護(hù)裝置。3.8.3.4 現(xiàn)場(chǎng)培訓(xùn)的費(fèi)用包括在報(bào)價(jià)之中。第9節(jié) 質(zhì)量管理西谷應(yīng)負(fù)責(zé)根據(jù)本協(xié)議的條件和條款對(duì)項(xiàng)目進(jìn)行全面質(zhì)量管理。西谷應(yīng)負(fù)責(zé)建立所需組織和程序并提供人員和支持設(shè)備或設(shè)施,以保證項(xiàng)目在規(guī)定的時(shí)間內(nèi)竣工,并保證可以滿足由客戶所簽訂的所有規(guī)定和程序。西谷指定一名項(xiàng)目經(jīng)理,負(fù)責(zé)本招標(biāo)項(xiàng)目范圍內(nèi)的所有工作。項(xiàng)目經(jīng)理是西谷與客戶之間的唯一重要聯(lián)絡(luò)人。客戶有權(quán)在協(xié)議履行過程中隨時(shí)接受或拒絕承包商項(xiàng)目經(jīng)理或關(guān)鍵管理人員和技術(shù)人員的任命。被拒絕的項(xiàng)目經(jīng)理或關(guān)鍵管理人員或技術(shù)人員必須立即離開,并安排客戶承認(rèn)的人接替。9.1 項(xiàng)目管理計(jì)劃9.1.1 西谷必須在協(xié)議簽訂后1周內(nèi)向客戶提交項(xiàng)目管理計(jì)劃。項(xiàng)目管理計(jì)劃必須與客戶的總項(xiàng)目管理計(jì)劃客戶,應(yīng)當(dāng)是西谷投標(biāo)文獻(xiàn)內(nèi)計(jì)劃的擴(kuò)展??蛻舫姓J(rèn)項(xiàng)目管理計(jì)劃后,該項(xiàng)目管理計(jì)劃的任何差異或修改都必須通過客戶的承認(rèn)。項(xiàng)目管理計(jì)劃至少應(yīng)包括如下內(nèi)容:9.1.2 一份闡明西谷組織的組織構(gòu)造圖,各實(shí)體參與方式闡明;各實(shí)體的一般責(zé)任和對(duì)本項(xiàng)目的責(zé)任,各實(shí)體的工

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論