***集團(tuán)煤直接液化項(xiàng)目固體物料輸送裝置棧橋獨(dú)立支架工程高層框架腳手架施工技術(shù)編制人:審核人:批準(zhǔn)人:安全會(huì)簽:中國(guó)***建設(shè)公司***項(xiàng)目經(jīng)理部二零零六年十一月二十日目錄1編制說(shuō)明2工程概況3編制依據(jù)及規(guī)范標(biāo)準(zhǔn)3.1編制依據(jù)3.2采用規(guī)范、標(biāo)準(zhǔn)4施工方法確定4.1腳手架搭設(shè)方法選擇4.2垂直運(yùn)輸方法選擇5施工程序和施工工藝5.1施工程序5.2施工工藝6施工準(zhǔn)備6.1現(xiàn)場(chǎng)準(zhǔn)備6.2技術(shù)準(zhǔn)備6.3物資準(zhǔn)備6.3.1··························································································116.3.2··························································································116.3.3·····················································································116.3.4·····················································································121/597地基與基礎(chǔ)處理8設(shè)計(jì)計(jì)算8.1落地式雙排單管立桿腳手架(35M以內(nèi))8.1.1鋼管截面特性指標(biāo)·································································138.1.2材料技術(shù)參數(shù)及荷載標(biāo)準(zhǔn)值·················································138.1.3荷載效應(yīng)組合·········································································158.1.4腳手架尺寸設(shè)計(jì)·····································································168.1.5腳手架允許搭設(shè)高度計(jì)算·····················································168.1.6腳手架受力驗(yàn)算·····································································198.2落地式雙排雙管立桿腳手架(35M以上)8.2.1腳手架設(shè)計(jì)·············································································248.2.2腳手架受力驗(yàn)算·····································································248.3斜道腳手架8.3.1斜道腳手架構(gòu)造·····································································278.3.2腳手架受力驗(yàn)算·····································································278.4立桿地基承載力計(jì)算8.4.1承載力計(jì)算·············································································298.4.2·················································································298.5框架梁支架計(jì)算8.5.1梁支架設(shè)計(jì)·············································································318.5.2梁荷載計(jì)算·············································································338.5.3·················································································332/598.5.4·················································································348.5.5·················································································348.5.6鋼管立柱驗(yàn)算·········································································358.6鋼管負(fù)偏差驗(yàn)算8.6.1負(fù)偏差說(shuō)明·············································································358.6.2負(fù)偏差驗(yàn)算·············································································369主要施工方法9.1地基處理9.2平面布置9.3搭設(shè)順序9.4技術(shù)措施9.4.1··························································································409.4.2··························································································419.4.3剪刀撐及橫向斜撐·································································429.4.4·····················································································439.4.5腳手板、踢腳板和護(hù)欄·························································449.4.6··························································································459.4.7入口安全通道·········································································459.4.8·················································································469.4.9框架梁支架·············································································469.4.10防雷接地···············································································469.4.11腳手架拆除···········································································473/5910檢查驗(yàn)收10.1驗(yàn)收程序及階段10.1.1驗(yàn)收程序···············································································4810.1.2驗(yàn)收階段···············································································4810.2構(gòu)配件驗(yàn)收10.2.1扣件·······················································································4810.2.2鋼管·······················································································4910.2.3木跳板···················································································4910.2.4安全網(wǎng)···················································································4910.3腳手架搭設(shè)質(zhì)量檢查10.4扣件擰緊質(zhì)量檢查11HSE管理措施11.1主要危險(xiǎn)源及環(huán)境因素識(shí)別11.2管理措施11.3技術(shù)措施11.4文明施工管理12、與相鄰單位的安全對(duì)策13、主要機(jī)械、材料使用計(jì)劃14、實(shí)際施工與方案偏離的總結(jié)14.1框架梁支架的偏離14.2內(nèi)外腳手架平面布置的偏離4/591編制說(shuō)明近些年,高層獨(dú)立支架工程愈來(lái)愈多,尤其是煤化工工業(yè)近些年發(fā)展迅速,而輸煤棧橋裝置是煤化工項(xiàng)目的重要組成部份。2005年我公司承建了***集團(tuán)煤直接液化項(xiàng)目備煤裝置的固體物料輸送工程,其工藝作用是將精煤分別輸送至備煤裝置、催化劑制備裝置和煤制氫裝置。本裝置土建工程包括原料煤轉(zhuǎn)運(yùn)站和棧橋兩部份,其中棧橋?yàn)殇摻铐趴蚣苤海撹旒芙Y(jié)構(gòu),棧橋共分為6高空作業(yè)多,工期短,技術(shù)要求高,尤其是腳手架工程對(duì)施工安全、質(zhì)量、進(jìn)度、成本及周邊環(huán)境的影響很大。為了與各位同仁共同交流、學(xué)習(xí),及時(shí)推廣應(yīng)用高層砼獨(dú)立支架腳手架搭拆施工技術(shù),本文以上述工程為例進(jìn)行論述,不足之處,敬請(qǐng)批評(píng)、指正。2工程概況固體物料輸送裝置是***集團(tuán)煤直接液化項(xiàng)目備煤裝置的重要組成部份,位于內(nèi)蒙古自治區(qū)鄂爾多斯市伊金霍洛旗馬家塔***煤直接燥廠房?jī)?nèi)的碎煤倉(cāng)內(nèi),為煤制氫裝置磨煤干燥工序提供原料。5/59原料煤輸送的輸送設(shè)備采用帶式輸送機(jī),設(shè)置2條精煤輸送線,1開(kāi)1備,每小時(shí)輸送原料煤650t/h。3層鋼筋砼框架結(jié)構(gòu),建筑面積980m2,設(shè)有封閉樓梯2部。棧橋包括A~F共6段,全長(zhǎng)729m。棧橋?yàn)殇摻铐趴蚣苤?,鋼桁架結(jié)構(gòu),棧橋的最大高度為56m抗震設(shè)防為7度。C棧橋?yàn)橹鳁?,全長(zhǎng)520m,包括12榀鋼筋砼獨(dú)立支架,每1榀獨(dú)立支架為8.5m*5.0m4根框架柱及封閉框架梁組成,框架梁層高普遍為4.5m~5m。獨(dú)立支架自東向西按1/10坡度下降,高度從56m~13m,相鄰支架間距普遍為40m,高差為?;A(chǔ)形等級(jí)為C30;框架柱最大截面為0.85m*0.75m,框架梁最大截面為0.80m*0.35m,柱梁砼等級(jí)為C35。具體位置詳見(jiàn)圖(13編制依據(jù)及規(guī)范標(biāo)準(zhǔn)3.1編制依據(jù)(1***工程科技有限責(zé)任公司設(shè)計(jì)的***煤直接液化項(xiàng)目備煤/催化劑裝置05016-623-X固體物料輸送裝置土建工程施工圖紙。6/597/59(2******煤直接液化項(xiàng)目固體物料輸(3和程序文件。(4***煤制油有限公司***煤直接液化項(xiàng)目管理手冊(cè)和程序文件。3.2采用規(guī)范、標(biāo)準(zhǔn)《建筑施工扣件式鋼管腳手架安全技術(shù)規(guī)范》JGJ130-2001?!督ㄖ┕ぐ踩珯z查標(biāo)準(zhǔn)》JGJ59-99?!督ㄖ┕じ咛幾鳂I(yè)安全技術(shù)規(guī)范》JGJ80-91?!妒突な┕ぐ踩夹g(shù)規(guī)程》SH3505-99。《建筑機(jī)械使用安全技術(shù)規(guī)程》JGJ33-2001?!妒┕がF(xiàn)場(chǎng)臨時(shí)用電安全技術(shù)規(guī)范》JGJ46-2005。《建筑施工現(xiàn)場(chǎng)環(huán)境與衛(wèi)生標(biāo)準(zhǔn)》JGJ146-2004。4施工方法確定4.1腳手架搭設(shè)方法選擇即以每榀獨(dú)立支架為單元,根據(jù)不同的高度段搭設(shè)不同型式的內(nèi)、外雙排鋼管腳手架。內(nèi)、外腳手架宜通過(guò)水平拉桿連成一個(gè)整體。內(nèi)雙排腳手架主要用于搭設(shè)斜道,供人上下通行;外雙排腳手8/59架主要用于施工操作及立面圍護(hù)。4.2垂直運(yùn)輸方法選擇垂直運(yùn)輸方法的正確選擇是高空作業(yè)的關(guān)鍵。經(jīng)過(guò)綜合比較,具體布置如下:材料(包括鋼筋、模板、鋼管、砼等)的垂直運(yùn)輸采用履帶式35m以下選用50t35m以上選用80t履帶吊。人員的垂直上下采用鋼管斜道。即在獨(dú)立支架內(nèi)搭設(shè)之字形雙排鋼管斜道供施工人員上下使用。5施工程序和施工工藝5.1施工程序物料輸送裝置棧橋支架施工劃為五個(gè)階段:第一階段:C棧橋中支架14#、高13m~35m,共7榀;第二階段:C棧橋中支架5#~1#高39m~56m,共5榀;第三階段:E棧橋支架13#高56m,共1榀。第四階段:F棧橋支架12#高55m,共1第五階段:A、B棧橋支架高16m,共2榀;9/595.2施工工藝本腳手架工程施工工藝分為兩種:棧橋支架高度35m以內(nèi)采用落地式雙排單管立桿腳手架;棧橋支架高度35m以上采用落地式雙排雙管立桿腳手架。6施工準(zhǔn)備6.1現(xiàn)場(chǎng)準(zhǔn)備(1)基礎(chǔ)及樁承臺(tái)砼已經(jīng)施工完,砼強(qiáng)度評(píng)定合格。(2)樁承臺(tái)子分部工程已經(jīng)驗(yàn)收合格。(3)基坑土方已經(jīng)分層回填夯實(shí)至樁承臺(tái)頂面以上;場(chǎng)地已平整,雜物已清理。水系統(tǒng)完善。6.2技術(shù)準(zhǔn)備(1)本施工技術(shù)方案已經(jīng)過(guò)我公司專家組論證,并經(jīng)總包單位、監(jiān)理單位、建設(shè)單位審核批準(zhǔn)。(2)已完成。(3)架子工和使用人員進(jìn)行了技術(shù)交底。10/59(4)檢查驗(yàn)收,不合格產(chǎn)品不得使用。6.3物資準(zhǔn)備6.3.1鋼管鋼管采用φ48,壁厚3.5mm,應(yīng)符合現(xiàn)行國(guó)家標(biāo)準(zhǔn)《直縫電焊鋼定的3號(hào)普通鋼管,其質(zhì)量應(yīng)符合現(xiàn)行國(guó)家標(biāo)準(zhǔn)《碳素結(jié)構(gòu)鋼》(GB/T700)中Q235-A級(jí)鋼的規(guī)定。立桿長(zhǎng)度定尺6m,縱向水平桿定尺6m,橫向水平桿定尺1.5m。所有鋼管上嚴(yán)禁打孔。6.3.2扣件本腳手架應(yīng)采用可鍛鑄鐵制作的扣件,其材質(zhì)應(yīng)符合現(xiàn)行國(guó)家扣件,應(yīng)經(jīng)試驗(yàn)證明其質(zhì)量符合該標(biāo)準(zhǔn)的規(guī)定后方可使用。腳手架采用的扣件,在螺栓擰緊扭力矩達(dá)65N.m時(shí),不得發(fā)生破壞。6.3.3腳手板50mm,兩端應(yīng)各設(shè)兩道直徑為4mm的鍍鋅鋼絲箍。6.3.4連墻件中Q235-A級(jí)鋼的規(guī)定。本腳手架采用φ48*3.5mm的鋼管。7地基與基礎(chǔ)處理現(xiàn)場(chǎng)承臺(tái)基礎(chǔ)砼已于2005年月全部結(jié)束,土方已回填。為了確保腳手架的安全,現(xiàn)對(duì)地基與基礎(chǔ)作如下處理:(1)地面以下1米范圍內(nèi)回填土必須分層夯實(shí)。(2臺(tái)面,以作為腳手腳支承基礎(chǔ)。腳手架外圍立桿不能落在砼樁承臺(tái)面上時(shí),可以利用掃地桿兩端挑出,并加設(shè)一根增強(qiáng)掃地桿,以分解垂直方向傳遞的荷載。支架、14#按此方法處理。(3橋支架周側(cè)內(nèi)外各現(xiàn)澆兩道C15素砼基礎(chǔ)帶,基礎(chǔ)帶截面為:寬×厚=400mm×250mm?,F(xiàn)澆基礎(chǔ)帶軸線與雙排腳手架內(nèi)外立桿縱向軸線相一致。支架1#~5#13#按此方法處理。(4收合格后方可搭設(shè)腳手架。基礎(chǔ)外周應(yīng)設(shè)300*200mm(寬)排水明溝,以利于地表雨水及時(shí)排除。以上地基處理理由詳見(jiàn)8.4.2章節(jié)。12/598設(shè)計(jì)計(jì)算8.1落地式雙排單管立桿腳手架(35m以內(nèi))8.1.1鋼管截面特性指標(biāo)表1鋼管截面特性指標(biāo)序號(hào)指標(biāo)φ48×3.51I(截面慣性矩)121900mm42W(截面模量)5080mm33i(回轉(zhuǎn)半徑)15.8mm4(截面積)48925(理論重量)3.84kg/m8.1.2材料技術(shù)參數(shù)及荷載標(biāo)準(zhǔn)值8.1.2.1材料技術(shù)參數(shù)表2鋼材Q235鋼抗拉、抗壓和抗彎強(qiáng)度設(shè)計(jì)值f205N/2Q235鋼抗剪強(qiáng)度設(shè)計(jì)值fv120N/mm2Q235鋼彈性模量E2.06×105mm2表3扣件項(xiàng)目自重(N/個(gè))承載力設(shè)計(jì)值(kN)對(duì)接扣件(抗滑)8.23.20直角扣件(抗滑)14.68.00旋轉(zhuǎn)扣件(抗滑)18.48.0013/59扣件螺栓擰緊扭力矩值不應(yīng)小于40N.m,且不應(yīng)大于65N.m。表4受彎構(gòu)件容許撓度構(gòu)件類別容許撓度[v]腳手板,縱向、橫向水平桿L/150與10mm懸挑受彎構(gòu)件L/300表5受壓、受拉構(gòu)件容許長(zhǎng)細(xì)比構(gòu)件類別容許長(zhǎng)細(xì)比[λ]雙排架210立桿單排架230橫向斜撐、剪力撐中的壓桿250拉桿3508.1.2.2荷載標(biāo)準(zhǔn)值表6永久荷載自重標(biāo)準(zhǔn)值木腳手板0.35kN/2(按平面計(jì)算)欄桿、木腳手板擋板0.14kN/m(按平面計(jì)算)整體拉結(jié)、防護(hù)材料0.077kN/2(按立面計(jì)算)表7施工均布活載標(biāo)準(zhǔn)值結(jié)構(gòu)腳手架3kN/2裝修腳手架2kN/2斜道2kN/28.1.2.3水平風(fēng)荷載標(biāo)準(zhǔn)值ωk=0.7μzμsωo14/59式中ωk——風(fēng)荷載標(biāo)準(zhǔn)值,kN/m2;μzGBJ935z=1.49;當(dāng)高度為56米時(shí),采用插入法求得μz=1.73;μs——腳手架風(fēng)荷載體型系數(shù),根據(jù)JGJ130-2001規(guī)范規(guī)定μs=1.3φ=1.3×1.2An/AW。因本腳手架外側(cè)面采用立式密目安全網(wǎng)全封閉,按n=1/3AW計(jì)算,則有μs=0.52;ωo——基本風(fēng)壓ωo=0.55kN/m2;則有:ωk=0.7×1.49×0.52×0.55=0.30kN/m2(離地高度35m)ωk=0.7×1.73×0.52×0.55=0.35kN/m2(離地高度56m)8.1.3荷載效應(yīng)組合表8荷載效應(yīng)組合計(jì)算項(xiàng)目荷載效應(yīng)組合永久荷載施工均布活荷載①永久荷載施工均布活荷載腳手架立桿穩(wěn)定②永久荷載+0.85(施工均布活荷載+風(fēng)荷載)單排架,風(fēng)荷載+3.0kN連墻件承載力雙排架,風(fēng)荷載+5.0kN15/598.1.4腳手架尺寸設(shè)計(jì)本工程獨(dú)立支架的外形尺寸普遍為A×B=9.1m×5.55m的層高普遍為4.5m~5.0m,腳手架搭設(shè)高度為13m~56m。根據(jù)JGJ130-2001排單管立桿腳手架搭設(shè)尺寸如下:立桿橫距Lb=1.05m,立桿縱距a=1.50m,小橫桿間距C=0.75m,內(nèi)立桿距建筑物外墻皮距離b1=0.35m,腳手架步距h=1.8m,腳手板鋪設(shè)4層(實(shí)際鋪設(shè)3作業(yè)層同時(shí)考慮212h=3.6m<框架梁的層高4.5m~5.0m3h=5.4m>框架梁的層高,故連墻件的設(shè)置應(yīng)采用三步三跨,即連墻件豎向間距1=3h=3×1.8=5.4m,水平間距1=3La=3×1.5=4.5m。以上設(shè)計(jì)中腳手板鋪設(shè)和作業(yè)層均比實(shí)際情況增加1主要是考慮到鋼管壁厚的負(fù)偏差會(huì)削弱鋼管自身的強(qiáng)度設(shè)計(jì)值,故人為地放大外部荷載,以便于按規(guī)范要求進(jìn)行設(shè)計(jì)驗(yàn)算。鋼管負(fù)偏差的驗(yàn)算詳見(jiàn)第8.6章節(jié)。以上設(shè)計(jì)的落地式雙排單管立桿腳手架搭設(shè)高度不宜超過(guò)34m。8.1.5腳手架允許搭設(shè)高度計(jì)算8.1.5.1不組合風(fēng)荷載時(shí)HS=[φAf-(1.2NG2K+1.4∑QK)]/1.2gk式中HS——按穩(wěn)定計(jì)算的允許搭設(shè)高度,m;φ——軸心受壓構(gòu)件的穩(wěn)定系數(shù),應(yīng)根據(jù)長(zhǎng)細(xì)比λ確定。16/59λ=L0/i=kμh/i=1.0×1.7×1800/15.8=3060/15.8=194≤λ]=210,查JGJ130-2001規(guī)范附錄C中表C得φ=0.191;A——立桿的截面面積,查表1得A=489mm2;f——鋼材的抗壓強(qiáng)度設(shè)計(jì)值,查表2得f=205N/mm2;NG2K——構(gòu)配件自重標(biāo)準(zhǔn)值產(chǎn)生的軸向力,腳手板鋪設(shè)4層,則有NG2KS)/2=(1523+58HS)N;∑NQK——施工荷載標(biāo)準(zhǔn)值產(chǎn)生的軸向力總和,按兩個(gè)操作層同時(shí)施工,查表7得∑QK=3000×1.05×1.5×2/2=4725N;gkJGJ130-2001規(guī)范附錄A中表A-1得gk=125N/m。則有:HS=[0.191×489×205-1.2×(1523+58HS)-1.4×4725]/(1.2×125)則有:HS=48.65m。8.1.5.2組合風(fēng)荷載時(shí)HS={φAf-[1.2NG2K+0.85×1.4(∑QK+MWKφA/W)]}/1.2gk式中MWK——風(fēng)荷載標(biāo)準(zhǔn)值產(chǎn)生的彎矩,暫按最大離地高度56m考慮,查8.1.2.fk0.35kN/m2。則有:MWK=ωka2/10=350×1.5×1.82/10170N.m;W——截面模量,查表1得W=5.08×10-63。17/59S’S(4725+170×0.191×489×10-6/(5.08×10-6))]}/(1.2×125)則有:HS=36.25m。因HS=48.65m>HS’許搭設(shè)高度[H]=HS/(1+0.001H’S結(jié)合工程實(shí)際情況,落地式雙排單管立桿腳手架最大搭設(shè)高度定為6搭設(shè)高度超過(guò)密卸載。35m以上采用落地式雙排雙管立桿腳手架。8.1.5.3各支架腳手架搭設(shè)高度及方式見(jiàn)表9表9各支架搭設(shè)高度及方式一覽表序號(hào)支架位號(hào)搭設(shè)高度(m)搭設(shè)方式1通廊支架156落地式雙排雙立桿2通廊支架251落地式雙排雙立桿3通廊支架347落地式雙排雙立桿4通廊支架443落地式雙排雙立桿5通廊支架539落地式雙排雙立桿6通廊支架635落地式雙排單立桿7通廊支架731落地式雙排單立桿8通廊支架827落地式雙排單立桿9通廊支架924落地式雙排單立桿10通廊支架1020落地式雙排單立桿11通廊支架1116落地式雙排單立桿12通廊支架1355落地式雙排雙立桿13通廊支架1413落地式雙排單立桿18/598.1.6腳手架受力驗(yàn)算8.1.6.1縱向、橫向水平桿抗彎強(qiáng)度:σ=M/W≤f式中M——彎矩設(shè)計(jì)值(N.mmM=1.2MGK+1.4∑MQK;W——截面模量,查表1得W=5080mm3;f——鋼材抗彎強(qiáng)度設(shè)計(jì)值,查表2得f=205N/mm2;GK——腳手板自重標(biāo)準(zhǔn)值產(chǎn)生的彎矩,N.m;∑QK——施工荷載標(biāo)準(zhǔn)值產(chǎn)生的彎矩,N.m。(1)橫向小水平桿抗彎強(qiáng)度驗(yàn)算按簡(jiǎn)支梁考慮,內(nèi)立桿距外墻0.35m寬不鋪設(shè)腳手板,不考慮荷載,計(jì)算簡(jiǎn)圖見(jiàn)圖(2GK=1/8qb2=1/8(K×C+Go)b2∑QK=1/8∑qb2=1/8(QK×C)b2M=1.2MGK+1.4∑MQK=1/8[1.2×(Gk×C+o)+1.4×K×C]b2式中GK——腳手架板自重,查表6得K=350N/m2;——小橫桿間距=0.75m;o——鋼管理論重量,查表1得o=3.84×9.8=38N/m;k——施工均布活荷載標(biāo)準(zhǔn)值,查表7得k=3000N/m2;19/59b——支座跨度,即立桿橫距1.05。則有:M=1/8[1.2×(350×0.75+38)+1.4×3000×0.75]×1.052=1/8××1.052=483.86N.m。故有:σ=M/W=483860/5080=95.25N/mm2≤f=205N/mm2。所以:橫向水平桿抗彎強(qiáng)度經(jīng)驗(yàn)算滿足規(guī)范規(guī)定,安全。(2)縱向大水平桿抗彎強(qiáng)度驗(yàn)算因連墻件是按三步三跨設(shè)置的,立桿縱距為1.5m連續(xù)梁近似計(jì)算,計(jì)算簡(jiǎn)圖見(jiàn)圖(3F為橫向小水平桿與縱向大水平桿交點(diǎn)處支座反力的最大值:F=1/2bq式中b=1.05m;q=1.2×(Gk×+o)+1.4×QM×C=1.2×(350×0.75+38)+1.4×3000。則有:M=0.175FL=0.175×(1/2×1.05×1.5=484N.m。故有:σ=M/W=484000/5080=95.3N/mm2≤f=205N/mm2。所以:縱向水平桿抗彎強(qiáng)度經(jīng)驗(yàn)算滿足規(guī)范規(guī)定,安全。20/598.1.6.2縱向、橫向水平桿撓度:ν≤[ν]式中ν——撓度,;ν——容許撓度,查表4得ν]=L/150≤10mm。(1)橫向小水平桿撓度驗(yàn)算:ν=5Fb3/384EI式中E——鋼材彈性模量。查表2得E=2.06×1052;I——鋼管截面慣性矩。查表1得I=121900mm4;×1.05=3686.55N。則有:ν=5×3686.55×1050/(384×2.06×10×121900)=2.21mm<1050/150=7mm。所以:橫向小水平桿撓度經(jīng)驗(yàn)算滿足規(guī)范規(guī)定,安全。(2)縱向大水平桿撓度驗(yàn)算:ν=1.146FLa3/100EI式中F=1/2bq=1/2×1.05×則有:ν=1.146×1843.28×15003/(100×2.06×105×121900)=2.84mm<1500/150=10mm。所以:縱向大水平桿撓度經(jīng)驗(yàn)算滿足規(guī)范規(guī)定,安全。8.1.6.3扣件抗滑承載力:R≤c式中R——縱向、橫向水平桿傳給立桿的豎向作用力。即為:縱向大水平桿與立桿交點(diǎn)處支座反力最大值Fmax=1/2qb=1843.28N,橫向小水平桿與立桿交點(diǎn)處支座反力最大值Fmax/=qb=3686.55N。c——扣件抗滑承載力設(shè)計(jì)值。查表3得:對(duì)接扣件抗滑承載力cmin=3200;直角扣件、旋轉(zhuǎn)扣件抗滑承載力cmin/=8000;21/59因縱向大水平桿需使用對(duì)接扣件連接,則有:R=Fmax=1843.28N<cmin=3200;因橫向小水平桿僅需使用直角扣件連接,則有:/=Fmax/=3685.55N<cmin/=8000N所以:扣件抗滑承載力經(jīng)驗(yàn)算滿足規(guī)范規(guī)定,安全。8.1.6.4立桿穩(wěn)定性(1)組合風(fēng)荷載時(shí):N/φA+MW/W≤f式中N——立桿的軸向力設(shè)計(jì)值,;8.1.5計(jì)算得φ=0.191;A——立桿的截面面積,查表1得A=4892;MW——立桿由風(fēng)荷載設(shè)計(jì)值產(chǎn)生的彎矩,N.m;W——鋼管截面模量,查表1得W=5080mm3;f——鋼材的抗壓強(qiáng)度設(shè)計(jì)值,查表2得f=205N/mm2;其中:N=1.2(G1K+G2K)+0.85×1.4∑NQK式中NG1K——腳手架結(jié)構(gòu)自重標(biāo)準(zhǔn)值產(chǎn)生的軸向力,NG1K=125N/m×35m=4375N;NG2K——構(gòu)配件自重標(biāo)準(zhǔn)值產(chǎn)生的軸向力,查8.1.5得NG2K=(1523+58HS)N=1523+58×35=3553N;∑QK——施工荷載標(biāo)準(zhǔn)值產(chǎn)生的軸向力總和,查8.1.5得∑QK4725N。則有:N=1.2×(4375+3553)+0.85×1.4×4725=15136N。2其中:MW=0.085×1.4ωkLah22/59式中k——風(fēng)荷載標(biāo)準(zhǔn)值。查8.1.2.f得ωk=300N/m2;則有:MW=0.085×1.4×300×1.5×1.82=174N.m故有:N/φA+MW/W=15136/(0.191×489)+174000/5080=1962<f=205N/mm2所以:立桿的穩(wěn)定性經(jīng)驗(yàn)算滿足規(guī)范規(guī)定,安全。(2)不組合風(fēng)荷載時(shí)://φA<f式中/——立桿的軸向力設(shè)計(jì)值。/=1.2(NG1K+G2K)+×1.4∑QK1.2×(4375+3553)+1.4×4725=16129N;故有://φA=16129/(0.191×489)=173N/mm2<f=205N/mm2。所以:立桿的穩(wěn)定性經(jīng)驗(yàn)算滿足規(guī)范規(guī)定,安全。8.1.6.5連墻件計(jì)算本腳手架工程連墻件采用扣件連墻件作剛性連接,連接方式為雙管雙扣件箍柱式,四角位置預(yù)埋φ12圓鋼進(jìn)行柔性連接補(bǔ)強(qiáng)。連軸向力設(shè)計(jì)值應(yīng)滿足:NL=N+No≤c式中NL——連墻件軸向力設(shè)計(jì)值,KN;NLw——風(fēng)荷載產(chǎn)生的連墻件軸向力設(shè)計(jì)值,NLw=1.4ωkw=1.4×0.30×5.4×4.5=10.21;No8雙排架取5KN。23/59則有:NL=10.21+5=15.21<2Rc=16KN(雙扣件)所以:連墻件的連接強(qiáng)度經(jīng)驗(yàn)算滿足規(guī)范規(guī)定,安全。8.2落地式雙排雙管立桿腳手架(35m以上)8.2.1腳手架設(shè)計(jì)根據(jù)8.1.5腳手架允許搭設(shè)高度不應(yīng)超過(guò)35m56m,故當(dāng)腳手架搭設(shè)高度超過(guò)35m時(shí)需采用落地式雙排雙管立桿腳手架進(jìn)行卸載。為便于現(xiàn)場(chǎng)統(tǒng)一施工,本方案確定腳手架在2/3高度處2/32/3高度以上采用單管立桿。落地式雙排雙管立桿腳手架所使用的材料規(guī)格及特性、搭設(shè)尺寸均與落地式雙排單管立桿腳手架一致,僅單立桿改為雙立桿,故上述內(nèi)容在此不再重復(fù)。8.2.2腳手架受力驗(yàn)算因荷載標(biāo)準(zhǔn)值、荷載效應(yīng)組合不變,故縱向、橫向水平桿抗彎強(qiáng)度、撓度變形同前,不需重新驗(yàn)算。因腳手架高度改變,豎向軸向力及風(fēng)荷載隨之改變,故需對(duì)立桿穩(wěn)定性和連墻件連接強(qiáng)度重新進(jìn)行驗(yàn)算。8.2.2.1立桿穩(wěn)定性(1)組合風(fēng)荷載時(shí):N/φA+MW/W≤f24/59式中N——立桿的軸向力設(shè)計(jì)值;8.1.5計(jì)算得φ=0.191;A——立桿的截面面積,查表1得A=4892×2(雙管);MW——立桿由風(fēng)荷載設(shè)計(jì)值產(chǎn)生的彎矩;W——鋼管截面模量,查表1得W=5080mm3×2(雙管);f——鋼材的抗壓強(qiáng)度設(shè)計(jì)值,查表2得f=205N/mm2。其中:N=1.2(G1K+G2K)+0.85×1.4∑NQK式中NG1K——腳手架結(jié)構(gòu)自重標(biāo)準(zhǔn)值產(chǎn)生的軸向力,NG1K=125N/m×56m=7000N;NG2K——構(gòu)配件自重標(biāo)準(zhǔn)值產(chǎn)生的軸向力,查8.1.5得NG2K=(1523+58HS)N=1523+58×56=4771N;∑QK——施工荷載標(biāo)準(zhǔn)值產(chǎn)生的軸向力總和。查8.1.5得∑QK4725N。則有:N=1.2×(7000+4771)+0.85×1.4×4725=19748N。2其中:MW=0.085×1.4ωkLahωk——風(fēng)荷載標(biāo)準(zhǔn)值,查8.1.2.fk=350N/m2則有:MW=0.085×1.4×350×1.5×1.82=202N.m故有:N/φA+MW/W=19748/(0.191×489×2)+202000/(5080×2)=1262<f=205N/mm2。所以:立桿的穩(wěn)定性經(jīng)驗(yàn)算滿足規(guī)范規(guī)定,安全。(2)不組合風(fēng)荷載時(shí)://φA≤f式中/——立桿的軸向力設(shè)計(jì)值,/=1.2(NG1K+G2K)+×1.4∑QK25/591.2×(7000+4771)+1.4×4725=20740N故有://φA=20740/(0.191×489×2)=1112≤f=205N/mm2所以:立桿的穩(wěn)定性經(jīng)驗(yàn)算滿足規(guī)范規(guī)定,安全。8.2.2.2連墻件計(jì)算本腳手架工程連墻件采用扣件連墻件作剛性連接,連接方式為四管四扣件箍柱式,四角位置預(yù)埋φ12圓鋼進(jìn)行柔性連接補(bǔ)強(qiáng)。連軸向力設(shè)計(jì)值應(yīng)滿足:NL=N+No≤c式中NL——連墻件軸向力設(shè)計(jì)值,KN;NLw——風(fēng)荷載產(chǎn)生的連墻件軸向力設(shè)計(jì)值,KN;NLw=1.4ωkw=1.4×0.35×5.4×4.5=11.91;No8雙排架取5KN。則有:NL=11.91+5=16.21<4Rc=32KN(四扣件)。所以:連墻件的連接強(qiáng)度經(jīng)驗(yàn)算滿足規(guī)范規(guī)定,安全。26/598.3斜道腳手架8.3.1斜道腳手架構(gòu)造斜道腳手架是在棧橋支架的內(nèi)部搭設(shè)落地式雙排腳手架,構(gòu)造1.05m1.5m1.8m。然后在內(nèi)、外立桿上按斜道坡度設(shè)斜桿,斜桿上加設(shè)小橫桿,小橫桿的縱距為1.5m,上滿鋪50厚的木腳手板。8.3.2腳手架受力驗(yàn)算8.3.2.1水平橫桿驗(yàn)算q/=1.2QGK+1.4QQK=1.2×(GkLb+L+Go)×/cosα+1.4×QKb/cosα式中GK——腳手架板自重,查表6得K=350N/m2;L——欄桿、擋腳板自重,查表6得L=140N/m;o——鋼管理論重量,查表1得o=3.84×9.8=38N/m;b——立桿橫距=1.05m;k——行人自重,平均為800N/m2;α——斜道坡度,按最大坡度計(jì)算α=40°。/°查8.1.6.1得q/<q平橫桿荷載<支架外部施工腳手架的水平橫桿荷載。故有斜道腳手架采用與外部落地式雙排單管外腳手架一樣的構(gòu)造時(shí),縱向、橫向27/59水平桿抗彎強(qiáng)度、撓度變形、扣件防滑承載力不需重新驗(yàn)算,是安全的。8.3.2.2立桿穩(wěn)定性驗(yàn)算′=1.2(NG1K+G2K1.4∑QK式中NG1K——腳手架結(jié)構(gòu)自重標(biāo)準(zhǔn)值產(chǎn)生的軸向力,NG1K=125N/m×35m=4375N;NG2K——構(gòu)配件自重標(biāo)準(zhǔn)值產(chǎn)生的軸向力,查05016-623-X-24施工圖紙,高度為35m的通廊支架6共有8層框架梁,即斜道腳手板需鋪設(shè)8NG2Kcos40×8)/2cos40°+(77×1.5×35)/2=5997N;∑QK按同一個(gè)垂直面內(nèi)同時(shí)有4人在斜道上,∑NQK=800×1.05×1.5×4/2=2520N;則有:N′1.2×(4375+5997)+1.4×2520=15974N查8.1.6.4得N=′<立桿荷載<支架外部施工腳手架的立桿荷載。故有斜道腳手架采用與外部落地式雙排單管外腳手架一樣的構(gòu)造時(shí),立桿穩(wěn)定性不需重新驗(yàn)算,是安全的。28/598.4立桿地基承載力計(jì)算8.4.1承載力計(jì)算立桿基礎(chǔ)底面的平均壓力應(yīng)滿足:P=N/A≤fg式中N——上部結(jié)構(gòu)傳至基礎(chǔ)頂面的軸向力設(shè)計(jì)值;A——基礎(chǔ)底面面積,采用3000×200×50木墊板,=La×b=1.5×0.2=0.32>0.252,取=0.252;fg——地基承載力設(shè)計(jì)值,fg=kc×f。其中:kc——腳手架地基承載力調(diào)整系數(shù),本工程地基為回填土,則查JGJ130-2001規(guī)范得kc=0.4;fgk——地基承載力標(biāo)準(zhǔn)值,查巖土工程勘察技術(shù)報(bào)告得素填土fgk=105KPa=1050002(1)當(dāng)腳手架高度為35m時(shí),查8.1.6.4得N=16129N。則有:N/A=16129/0.25=64516N/2>fg=0.4×105000=42000N/2所以:地基承載力不夠,需處理。(2)當(dāng)腳手架高度為56m時(shí),查8.2.2.1得20740N。則有:N/A=20740/0.25=82960N/2>fg=42000N/2所以:地基承載力不夠,需處理。8.4.2地基處理為統(tǒng)一做法,便于現(xiàn)場(chǎng)施工,根據(jù)以上計(jì)算結(jié)果,針對(duì)腳手架29/59的不同搭設(shè)方式,采用以下兩種地基處理方法:(1)35m包括通廊支架、14#共7榀,該7榀支架砼承臺(tái)頂面埋深均為-0.7m,將承臺(tái)頂面及外周2m范圍內(nèi)土方全部挖除,露出承臺(tái)砼面,腳手架內(nèi)立桿直接支撐在承臺(tái)砼面上,無(wú)承臺(tái)的內(nèi)立桿及外立桿下墊3000×200×50外立桿連接卸載。經(jīng)過(guò)以上處理,將大部份立桿荷載轉(zhuǎn)卸在砼承臺(tái)上,腳手架是安全的。詳見(jiàn)圖(4(2)35m包括通廊支架1#~5#、13#共6榀,該6榀支架砼承臺(tái)面埋深較大,且支架1#~5#均有地梁尚末施工,不宜采用砼承臺(tái)支撐法。為擴(kuò)大立桿承壓面積,需現(xiàn)澆C15砼帶形基礎(chǔ),需計(jì)算基礎(chǔ)最小寬度b。要求:N/A≤fg即有:20740/1.5b=13827b≤42000N/2即有:b≥0.33m。砼基礎(chǔ)的寬高比允許值為2:1,現(xiàn)取基礎(chǔ)寬度為0.4m,基礎(chǔ)高度為0.25m。經(jīng)過(guò)加大立桿承壓底面積,降低了地基30/59承載力,腳手架是安全的。詳見(jiàn)圖(58.5框架梁支架計(jì)算8.5.1梁支架設(shè)計(jì)框架梁模板支架采用鋼管支撐、復(fù)合木模板體系,梁支架體系選用最大的框架梁進(jìn)行模板支架設(shè)計(jì),其余梁參照?qǐng)?zhí)行。最大框架梁為支架13中的KL1,矩形梁截面B×H=350mm×800mm,梁凈長(zhǎng)L=7.7m4.8m大楞、豎楞、橫楞、立柱和水平拉桿組成,詳見(jiàn)圖(631/59梁底模采用50系統(tǒng)采用φ48㎜×3.5mm鋼管,梁底設(shè)雙排立桿,立桿斜撐在下一層框架梁上,立桿橫距為750㎜,立桿縱距為750㎜,小橫楞間距為750㎜,大橫楞桿步距為1.8。表10杉木特性技術(shù)參數(shù)表1抗彎強(qiáng)度f(wàn)m11N/mm22順紋抗壓強(qiáng)度f(wàn)c10N/mm23順紋抗剪強(qiáng)度f(wàn)v1.3N/mm24彈性模量E9000N/mm25截面慣性矩I9000mm46密度ρ4000N/m332/598.5.2梁荷載計(jì)算模板結(jié)構(gòu)自重:600N/m砼自重:24000×0.35×0.8=6720N/m鋼筋自重:1500×0.35×0.8=420N/m施工人員及施工設(shè)備荷載:1000×0.35=350N/m振搗砼產(chǎn)生的荷載:2000×0.35=700N/m傾倒砼產(chǎn)生的荷載:2000×0.35=700N/m8.5.3底模驗(yàn)算8.5.3.1抗彎強(qiáng)度驗(yàn)算按簡(jiǎn)支梁驗(yàn)算:δ=M/W≤fmM=qL2/8q=1.2∑NGK+1.4∑QK=1.2600+6720+420+1.4350+700+700)=11738N/m=12N/mmM=12×7502/8=843750N.mmW=bh2/6=350×50/6=145833mm3δ=M/W=843750/145833=5.8N/mm2m=11N/mm2所以:底??箯潖?qiáng)度經(jīng)驗(yàn)算,安全。8.5.3.2撓度驗(yàn)算ω=5qˊL/384EI≤[ω]=L/250EI=9000×(350×503/12)=32813×106ω=5×12×7504/(384×32813×106)=1.5mm<L/250=750/250=3mm所以:底模撓度經(jīng)驗(yàn)算,安全。33/598.5.4小楞驗(yàn)算8.5.4.1抗彎強(qiáng)度驗(yàn)算小楞間距為上的荷載可簡(jiǎn)化為一個(gè)集中荷載計(jì)算。δ=M/W≤fmM=PL(2-b/L)/8P=12N/mm×350mm=4200NM=4200×750×(2-350/750)/8=603750N.mmδ=603750/5080=119N/mm2m=205N/mm2所以:小楞抗彎強(qiáng)度經(jīng)驗(yàn)算,安全。8.5.4.2撓度驗(yàn)算ω=5qˊL/384EI≤[ω]=L/250EI=2.06×105×12.19×10=25111×106ω=5×12×7504/(384×25111×106)=2mm<L/250=750/250=3mm所以:小楞撓度經(jīng)驗(yàn)算,安全。8.5.5大楞驗(yàn)算按連續(xù)梁計(jì)算,承受小楞傳來(lái)集中荷載,簡(jiǎn)化成均布荷載計(jì)算。8.5.5.1抗彎強(qiáng)度驗(yàn)算δ=M/W≤fmM=qL2/1012×7502/10=675000N.mδ=675000/5080=133N/mm2m=205N/mm2所以:大楞抗彎強(qiáng)度經(jīng)驗(yàn)算,安全。34/598.5.5.2撓度驗(yàn)算ω=qˊL4/150EI≤[ω]=L/250EI=2.06×105×12.19×10=25111×106ω=12×7504/(150×25111×106)=1.3mm<L/250=750/250=3mm所以:大楞撓度經(jīng)驗(yàn)算,安全。8.5.6鋼管立柱驗(yàn)算按立柱的穩(wěn)定性控制,可按兩端鉸接受壓構(gòu)件來(lái)簡(jiǎn)化計(jì)算。立柱穩(wěn)定性驗(yàn)算公式如下:δ=N/φA≤fm式中N——每根立桿承受的荷載。N=qL/2=12×750/2=4500N<[N]=11600N;φ——軸心受壓構(gòu)件的穩(wěn)定系數(shù),應(yīng)根據(jù)長(zhǎng)細(xì)比λ確定,λ=L0/i=kμh/i=1.0×1.7×1800/15.8=194≤[λ]=210,查JGJ130-2001規(guī)范附錄C中表C得φ=0.191;A——立桿的截面面積。查表1得A=489mm2;則有:δ=N/φA=4500/0.191×489=48N/mm2m=205N/mm2。所以:鋼管立柱的穩(wěn)定性經(jīng)驗(yàn)算,安全。8.6鋼管負(fù)偏差驗(yàn)算8.6.1負(fù)偏差說(shuō)明本方案腳手架鋼管是按直徑φ48,壁厚3.5mm考慮的,根據(jù)JGJ130-200135/59在壁厚負(fù)偏差現(xiàn)象。壁厚的負(fù)偏差對(duì)鋼管自身的材料特性和技術(shù)參數(shù)有直接影響,尤其對(duì)鋼管的抗拉、抗壓和抗彎強(qiáng)度設(shè)計(jì)值f會(huì)有明顯地削弱。根據(jù)經(jīng)驗(yàn)統(tǒng)計(jì)數(shù)據(jù),壁厚3.0mm鋼管強(qiáng)度設(shè)計(jì)值f/約為壁厚3.5mm鋼管強(qiáng)度設(shè)計(jì)值f的90%~95%,即強(qiáng)度將削弱5%~10%。本方案按最不利情況考慮,取強(qiáng)度削弱10%。為確保施工安全,應(yīng)對(duì)鋼管的負(fù)偏差進(jìn)行驗(yàn)算,若不能滿足規(guī)范要求,應(yīng)采取補(bǔ)強(qiáng)措施。8.6.2負(fù)偏差驗(yàn)算根據(jù)8.1.4情況增加1層,人為地放大了外部荷載,其原因主要是考慮到鋼管壁厚的負(fù)偏差會(huì)削弱鋼管自身的強(qiáng)度設(shè)計(jì)值。故可以近似地認(rèn)為,-1>強(qiáng)度削弱10%時(shí),鋼管壁厚出現(xiàn)負(fù)偏差時(shí),以上腳手架設(shè)計(jì)也是安全的。查8.1.6.4得,腳手架設(shè)計(jì)荷載值N=16129N。另腳手架實(shí)際荷載值/=1.2(N/)+1.4∑QK/+N/G1KG2KNG1K/——腳手架結(jié)構(gòu)自重標(biāo)準(zhǔn)值產(chǎn)生的軸向力,NG1K=125N/m×35m=4375NNG2K/8.1.5板鋪設(shè)3層時(shí)NG2K/=(1523×3/4+58HS)N=1142+58×35=3172N;36/59∑QK/8.1.5作業(yè)層為1層時(shí)∑QK/4725N/2=2363N。則有:/1.2×(4375+3172)+1.4×2363=12365NN/N/-1)(16129/12365-1%=30%>強(qiáng)度削弱10%所以:鋼管壁厚出現(xiàn)規(guī)范允許范圍內(nèi)的負(fù)偏差時(shí),以上腳手架設(shè)計(jì)也是安全的。9主要施工方法9.1地基處理按照第七章的要求對(duì)搭設(shè)場(chǎng)地進(jìn)行平整、回填土夯實(shí)等地基處理,確保立桿有穩(wěn)固可靠的地基。然后按照第八章確定的立桿橫距和縱距進(jìn)行放線定位,鋪設(shè)墊板并確保位置準(zhǔn)確、鋪放平穩(wěn),不得懸空。雙立桿腳手架C15砼墊層應(yīng)提前澆筑,覆蓋保溫養(yǎng)護(hù),待達(dá)到設(shè)計(jì)強(qiáng)度的75%以上時(shí)方可使用。腳手架拆除后該砼基礎(chǔ)留于原處,不另作處理。當(dāng)使用雙立桿時(shí)應(yīng)將雙管用φ6圓鋼連焊在一起。9.2平面布置根據(jù)第八章的設(shè)計(jì)驗(yàn)算,并結(jié)合施工圖的設(shè)計(jì)尺寸,重新計(jì)算相關(guān)間距,并不大于以上設(shè)計(jì)間距,然后確定腳手架的平面位置及37/599.3搭設(shè)順序1底端與縱向掃地桿扣接固定→裝掃地水平小橫桿并與立桿或掃地桿扣緊(固定立桿底端前,應(yīng)吊線確保立桿垂直)→安放第一步水平大橫桿(與各立桿扣緊)→安第一步水平小橫桿(校正立桿垂直度和水平桿水平度,然后按40~60N.m力矩?cái)Q緊扣件螺栓,形成構(gòu)架的起始段)→按上述要求依次向前延伸搭設(shè),直至第一步架交圈完成。交圈后,再全面檢查一遍構(gòu)架質(zhì)量和地基情況,確保符合設(shè)計(jì)要求→第二步水平大橫桿→第二步水平小橫桿→加設(shè)臨時(shí)斜撐桿(上端與第二步大橫桿扣緊,在裝設(shè)兩道連墻桿后拆除)→第三、四步大橫桿和小橫桿→連墻桿→加設(shè)剪刀撐—加設(shè)作業(yè)層加密小橫桿→鋪腳手板和裝設(shè)欄桿、踢腳板→掛設(shè)安全網(wǎng)。38/59框架柱850×750框架梁350×800(梁凈長(zhǎng))×(外架長(zhǎng))腳手架平面布置圖圖(7)欄桿框架柱踢腳板作業(yè)層框架梁腳手板連墻件剪刀撐大橫桿立桿小橫桿掃地桿腳手架正立面圖圖(8)39/599.4技術(shù)措施9.4.1立桿立桿橫距為1.05m,縱距為對(duì)于35m以上的落地式雙排雙管立桿腳手架,應(yīng)在腳手架總高的2/3處進(jìn)行分段卸載,即架高的2/3以下段采用雙管立桿,2/3以上段采用單管立桿,兩根立桿之間間距不應(yīng)大于0.2m,單雙立桿腳手架必須設(shè)置縱、橫向掃地桿,縱向掃地桿應(yīng)采用直角扣件固定在距離底上皮不大于0.2m角扣件固定在緊靠縱向掃地桿下方的立桿上。搭設(shè)掃地桿時(shí),應(yīng)每隔640/59當(dāng)搭至有連墻件的構(gòu)造點(diǎn)時(shí),在搭設(shè)完該處的立桿、縱向水平桿、橫向水平桿后,應(yīng)立即設(shè)置連墻件。立桿接長(zhǎng)除頂層頂步外,其余各層各步接頭必須采用對(duì)接扣件連接。立桿的垂直偏差,當(dāng)架在30m以內(nèi)時(shí),應(yīng)不大于架高的1/200,當(dāng)架高在30m1/400~1/600高偏斜不大于10cm。9.4.2橫桿縱向水平桿宜設(shè)置在立桿內(nèi)側(cè),其長(zhǎng)度不宜小于3跨。相鄰位置縱向水平大橫桿的接長(zhǎng)位置應(yīng)錯(cuò)開(kāi)布置在不同的立桿41/59偏差不大于該片腳手架總長(zhǎng)度的相鄰步架的水平小橫桿應(yīng)錯(cuò)開(kāi)布置在立桿的兩側(cè),以減少立桿偏心受載情況。水平小橫桿貼近立桿布置,搭于大橫桿之上,并用直角扣件扣緊。在相鄰立桿之間加設(shè)一根小橫桿,以減小腳手板變形。在任何情況下,均不得拆除貼近立桿的小橫桿。9.4.3剪刀撐及橫向斜撐腳手架的四面均應(yīng)設(shè)置剪刀撐,剪刀撐應(yīng)聯(lián)系所有立桿,斜桿與地面夾角為45°~60°。剪刀撐應(yīng)沿架高連續(xù)布置,剪刀撐的斜桿除二端用旋轉(zhuǎn)扣件與腳手架的立桿或大橫桿扣緊外,在其中間應(yīng)增加2~4個(gè)扣結(jié)點(diǎn)。剪刀撐的搭接是將一根斜桿扣在立桿上,另一根斜桿扣在小橫桿的伸出部分上。斜桿兩端扣件與立桿節(jié)點(diǎn)(即立桿與橫桿交點(diǎn))的距離不宜于大于20cm,斜桿的最下端必須落至地面,以將荷載卸42/59至地基上。高度在24m以下的雙排腳手架可不設(shè)橫向斜撐,高度在24m以上的封閉型腳手架,除四周拐角應(yīng)設(shè)置橫向斜撐外,中間應(yīng)每隔6跨設(shè)置一道。9.4.4連墻桿連墻件按三步三跨設(shè)置,采用雙管或四管箍柱式剛性連墻件與砼框架柱、框架梁可靠連接。詳見(jiàn)圖(1213當(dāng)腳手架下部暫不能設(shè)連墻桿件時(shí)可搭設(shè)拋撐。拋撐應(yīng)采用通45°-60點(diǎn)中心至主節(jié)點(diǎn)的距離不應(yīng)大于300mm可拆除。連墻件中的連墻桿或拉筋宜呈水平設(shè)置,當(dāng)不能水平設(shè)置時(shí),與腳手架連接的一端應(yīng)下斜連接,不應(yīng)采用上斜連接。43/599.4.5腳手板、踢腳板和護(hù)欄使用3m×0.2m×0.05m(厚的)水平桿兩端均應(yīng)用直角扣件固定在縱向水平桿上。作業(yè)層腳手板應(yīng)鋪滿,鋪穩(wěn),腳手板應(yīng)設(shè)置在三根橫向水平桿上,當(dāng)腳手板長(zhǎng)度小于2m時(shí),可采用兩根橫向水平桿支承,但應(yīng)將腳手板兩端與其可靠固定,嚴(yán)防傾翻。設(shè)兩根橫向水平桿,腳手板外伸長(zhǎng)應(yīng)取150mm,兩塊腳手板外伸長(zhǎng)度的和不應(yīng)大于300mm。詳見(jiàn)圖(14作業(yè)層端部腳手板探頭長(zhǎng)度應(yīng)取150mm承桿可靠地固定。在鋪腳手板的操作層上必須設(shè)踢腳板和護(hù)欄,踢腳板采用寬200mm15mm1.2m,設(shè)兩道水平桿,外掛密目安全網(wǎng)。詳見(jiàn)圖(1544/599.4.6斜道本工程在支架內(nèi)部搭設(shè)落地式雙排腳手架作為人行斜道。內(nèi)腳手架構(gòu)造同外腳手架,在內(nèi)、外立桿上設(shè)坡道斜桿,坡度<40°,具體坡度依據(jù)框架梁層高而定。斜道為之字形,支架長(zhǎng)方向?yàn)樾碧?,支架短方向?yàn)樾菹⑵脚_(tái),1.2m高的鋼管護(hù)欄及200mm高踢腳板。斜道腳手板采用3m×0.2m×0.05m(厚的)上必須設(shè)防滑條,防滑條間距不大于300mm,木條厚度30mm。平桿,腳手板背面釘設(shè)防滑條,防滑條嵌卡在橫向水平桿之間,以免腳手板上下滑動(dòng)。入斜道內(nèi),以保證斜道上的行人安全。9.4.7入口安全通道為統(tǒng)一現(xiàn)場(chǎng)布置,便于管理,將所有斜道入口設(shè)置在棧橋支架的東北角。入口門(mén)洞采用上升斜桿、平行弦桿桁架結(jié)構(gòu)型式,將入口處1根立桿提升約2步距,提升立桿兩側(cè)各增加1根斜桿,通過(guò)2.5m,高約3m的洞口。在入口處用鋼管搭設(shè)寬2m2.5m2.5m45/59兩側(cè)用竹笆片封閉,頂部搭設(shè)雙層竹笆防護(hù)層,入口處掛設(shè)安全標(biāo)志和宣傳標(biāo)語(yǔ),從入口處至斜道形成一個(gè)完全封閉的安全通道。9.4.8懸挑攔網(wǎng)因本腳手架超高,為減少高空落物對(duì)地面物的打擊,需設(shè)置懸3層框架高約15m設(shè)置一道。采用鋼管水平外挑,鋼管間距1.5m,在鋼管間水平兜掛密目安全攔網(wǎng),水平攔網(wǎng)與立式安全網(wǎng)連接處不應(yīng)有縫隙,以免落物漏空;同時(shí)水平攔網(wǎng)不得拉平拉緊,應(yīng)留有一定的自由度,以減緩落物的沖擊力,避免攔網(wǎng)被穿孔。9.4.9框架梁支架框架梁模板支架采用鋼管支撐、復(fù)合木模板體系,梁支架體系模板支架構(gòu)造詳見(jiàn)8.5條規(guī)定。因模板支架的荷載是由下層框架梁承載的,故下層框架梁底模只有當(dāng)?shù)谌龑恿喉攀┕ね戤吅蠓娇烧鄢谝粚恿旱啄VЪ堋?.4.10防雷接地腳手架搭設(shè)時(shí),應(yīng)利用原基礎(chǔ)施工時(shí)埋設(shè)的接地線進(jìn)行防雷接地。采用φ10圓鋼連接接地,每個(gè)支架設(shè)2處接地點(diǎn)。46/599.4.11腳手架拆除(1)準(zhǔn)備工作拆除腳手架前,應(yīng)清除腳手架上的材料,工具及雜物。b.應(yīng)全面檢查腳手架的扣件連接、連墻桿、支撐體系等是否符合構(gòu)造要求。拆除腳手架時(shí),應(yīng)設(shè)置警戒區(qū)和警戒標(biāo)志,并由專職人員負(fù)責(zé)警戒,禁止行人進(jìn)入。(2)腳手架拆除桿等,嚴(yán)禁上下同時(shí)作業(yè)。b.安全防護(hù)用品。暫不拆除的兩端加設(shè)連墻點(diǎn)和橫向水平支撐。d.當(dāng)腳手架拆至下部最后一根長(zhǎng)立桿的高度約6m位置搭設(shè)臨時(shí)拋撐加固后,再拆除連墻件。一人有關(guān)的結(jié)扣時(shí),應(yīng)先告知對(duì)方,以防墜落。f.拆下的扣件和配件應(yīng)及時(shí)運(yùn)至地面,嚴(yán)禁拋擲至地面。47/5910檢查驗(yàn)收10.1驗(yàn)收程序及階段10.1.1驗(yàn)收程序HSE、搭設(shè)班組、使用班組等部門(mén)組成驗(yàn)收小組,對(duì)所搭設(shè)完成的腳手架進(jìn)行驗(yàn)收,驗(yàn)收合格、出具相關(guān)驗(yàn)收文件后方可進(jìn)入下一道工序。施工過(guò)程中全員都可對(duì)腳手架隨時(shí)進(jìn)行檢查。對(duì)需臨時(shí)拆除的部分桿件應(yīng)報(bào)施工經(jīng)理或項(xiàng)目總工程師批準(zhǔn),方可拆除,工作完畢后必須及時(shí)恢復(fù),并報(bào)施工經(jīng)理復(fù)驗(yàn)。10.1.2驗(yàn)收階段腳手架工程應(yīng)在下列階段進(jìn)行檢查與驗(yàn)收:(1(2(3)每搭完10~13m高度后;(4)達(dá)到設(shè)計(jì)高度后;(56)停用超過(guò)一個(gè)月。10.2構(gòu)配件驗(yàn)收10.2.1扣件扣件進(jìn)場(chǎng)后由HSE不能有裂紋、氣孔、疏松、砂眼等鑄造缺陷??奂仨氁泻细褡C48/59或質(zhì)量證明書(shū),不合格材料嚴(yán)禁使用在工程中??奂c鋼管的貼合面要接觸良好,扣件夾緊鋼管時(shí),開(kāi)口處的最小距離要小于5mm。T和脫絲、滑絲現(xiàn)象。10.2.2鋼管合規(guī)范及方案要求,外徑、壁厚必須滿足計(jì)算外徑、厚度要求。端面的偏差應(yīng)符合規(guī)范要求。鋼管表面應(yīng)平直光滑,不應(yīng)有裂縫、結(jié)疤、分層、錯(cuò)位、硬彎、毛刺、壓痕。10.2.3木跳板GBJ5)中Ⅱ級(jí)材質(zhì)的規(guī)定,材質(zhì)為杉木或松木,腐朽的腳手板不得使用。10.2.4安全網(wǎng)安全網(wǎng)采用800目的密目立式雙繩尼龍網(wǎng),安全網(wǎng)規(guī)格為長(zhǎng)*高=6m*1.8m張立網(wǎng)正好封閉一步四跨,減少立網(wǎng)之間的連接。安全網(wǎng)在拐角處應(yīng)采用整張網(wǎng)包角,不應(yīng)搭接。試驗(yàn)合格后方可正式掛設(shè)使用。49/5910.3腳手架搭設(shè)質(zhì)量檢查表腳手架搭設(shè)質(zhì)量檢查一覽表序允許偏檢查方法
項(xiàng)目技術(shù)要求號(hào))與工具表面堅(jiān)實(shí)平整—排水不積水—地基1墊板不晃動(dòng)—觀察基礎(chǔ)不滑動(dòng)—底座不沉降-10立桿垂直用經(jīng)緯儀或吊2最后驗(yàn)收垂直度2080m—±100度線和卷尺步距—±203間距縱距—±50鋼板尺橫距—±20一根桿的兩端—±20
縱向水平水平儀或
4兩跨內(nèi)兩根縱向水平桿桿高差外伸500mm±10水平尺長(zhǎng)度偏差5雙排腳手架橫向水平桿長(zhǎng)度偏差外伸500mm–50鋼板尺主節(jié)點(diǎn)處各扣件中心點(diǎn)a≤150—鋼板尺相互距離同步立桿上兩個(gè)相隔對(duì)接a≥500——鋼卷尺扣件的高差6扣件安裝立桿上的對(duì)接扣件a≤h/3——鋼卷尺至主節(jié)點(diǎn)的距離縱向水平桿上的對(duì)接扣件a≤La——鋼卷尺至主節(jié)點(diǎn)的距離扣件螺栓擰緊扭力矩4065N·m—扭力板手7剪刀撐斜桿與地面的傾角4060°-角尺50/5910.4扣件擰緊質(zhì)量檢查按隨機(jī)分布原則進(jìn)行。抽樣檢查數(shù)目與質(zhì)量判定標(biāo)準(zhǔn),應(yīng)按下表12規(guī)定確定。不合格的必須重新擰緊,直至合格為止。表12扣件擰緊質(zhì)量檢查一覽表項(xiàng)安裝扣件數(shù)抽檢數(shù)量允許的不
檢查項(xiàng)目目量(個(gè))(個(gè))合格數(shù)51~905091~15081水平桿或剪刀撐的扣151~2801311281~500202平桿或剪刀撐的扣件501~12003231201~320050551~9051連接橫向水平桿與縱91~150822150~280133節(jié)點(diǎn)處)281~50020551/5911HSE管理措施11.1主要危險(xiǎn)源及環(huán)境因素識(shí)別由項(xiàng)目經(jīng)理組織技術(shù)、安全、施工等人員進(jìn)行主要危險(xiǎn)源及環(huán)境因素的識(shí)別,在此基礎(chǔ)上確定HSE管理措施及控制措施。本施工過(guò)程中的主要危險(xiǎn)源及環(huán)境因素評(píng)價(jià)及控制措施詳見(jiàn)《固體物料輸送裝置施工組織設(shè)計(jì)》相關(guān)章節(jié)內(nèi)容,本文略。11.2HSE管理措施(1考試不合格者禁止進(jìn)入施工現(xiàn)場(chǎng)。作業(yè)前進(jìn)行安全技術(shù)交底,所有施工人員均須熟悉本施工方案及本工程內(nèi)容,并按方案要求進(jìn)行施工。(2)特種作業(yè)人員應(yīng)經(jīng)培訓(xùn)取得操作證后方可上崗作業(yè)。(3
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 平臺(tái)服務(wù)抽合同范例
- 工程居間付款合同模板
- 工業(yè)廠房干貨合同范例
- 婚慶店轉(zhuǎn)讓合同范例
- 加盟餐飲商務(wù)合同范例
- 工傷死亡合同范例
- 徐州企業(yè)職工勞動(dòng)合同范例
- 個(gè)人攤位轉(zhuǎn)讓合同模板
- 學(xué)生與學(xué)校保安合同范例
- 床墊代加工合同模板
- 口腔科醫(yī)療護(hù)理技術(shù)操作規(guī)程版
- 九年級(jí)心理健康教育教案 全冊(cè)
- 在例題與命題研究中實(shí)現(xiàn)教師專業(yè)成長(zhǎng)
- 頭顱CT精美完整課件
- 安全總監(jiān)安全職責(zé)
- 附錄2.1-3培養(yǎng)目標(biāo)達(dá)成度評(píng)價(jià)報(bào)告修改
- 云南白族課件
- 消防應(yīng)急預(yù)案組織結(jié)構(gòu)圖
- 肝衰竭肝功能衰竭
- 油站使用說(shuō)明書(shū)
- 小學(xué)班主任工作經(jīng)驗(yàn)交流ppt
評(píng)論
0/150
提交評(píng)論