1、Reactance of Induction MachinesFundamental ConceptsL = Instantaneous Inductance of Coil (Henries)e = Instantaneous value of voltage induced in the coil by the change of current (Volts)di/dt = Instantaneous value of the rate of change of the current which flows through the coilFaradays Lawepath = ind
2、uced voltage around an enclosed pathE = Vector of Electric Field around the pathdl = Vector of enclosed pathd/dt = Rate of Change of Flux enclosed by the pathA more useful form of Faradays law:whereIs the sum of all fluxes x linking corresponding turns nx of the coilCombining EquationsReactance of a
3、n inductive circuitX=2fL (Ohms)f=freqency of voltage across inductance (Hz)orAmperes Circuit LawH = Vector of Magnetic Field Intensity (Amp/meter)dl = Vector along the length of the pathJ = Vector field of current density enclosed by path dA = area enclosed by the pathTo apply Amperes Circuit law, c
4、onsider the simple magnetic circuit of a torus with a non-ferromagnetic coreHr(2r) = Ni B=uruoHB = Vector Quantity of Magnetic Flux Density (Tesla)uo = constant relating Flux Density to Flux Intensity in free space or non-ferrous materials = 4x10-7 (Tm/A)ur = proportionality constant for ferromagnet
5、ic materials (unit-less)Rearranging:Also:Amp/meterThe integration of flux density over a unit area gives total flux . For a torroid =BA WebersCombining Equations for L and , the inductance of the coil is shown to be determined entirely by the dimensions of the coil and independent of the current in
6、the wire. The reactance of the torroid is thenFor Ferromagnetic Materials, a value of r o is read from a Saturation CurveEffect of Saturation on InductanceEquivalent Circuit of Induction Motor R1 Primary resistanceX1 Leakage reactance of primary windingXM Magnetizing Reactancegh = Resistance path to
7、 account for core lossX2 Secondary leakage reactanceR2/s Resistance of squirrel cage windingThere is no standard method for reactance calculations as simplifying assumptions are made at many steps in their calculation. The formulas to follow have many simplifying assumptions (such as no saturation)
8、that I will try to point out as we go along. However, the dependency of reactance to physical parameters is the same for all calculation methods.Magnetizing Reactance XMT=Reactance FactorD= Stator Bore Diameter (I.D.)L=Core Length in InchesKW = Stator Winding Factor Kd x Kp g = single air gap inches
9、Kg = Carters AirGap CoefficientP = # PolesT = Reactance Factor = Wheref= frequencym=# of phasesZ = # stator conductors in series per phaseThe resultant voltage in the air gap available to create the rotating magnetic field is less than the peak voltage of the sine wave at the motor terminals Because
10、 of 2 factors: Kp: Accounts for the pitch of the winding Kd: Accounts for the distribution of the windingTo account for the slot openings of the stator and rotor surface, a gap factor is used as a multiplier to create an “effective air gap. This factor is called the “Carters Coefficient Kg KW=KpKdTo
11、tal Leakage Reactance X1 +X2The Primary slot reactanceThe Secondary slot reactanceThe zig-zag reactanceThe belt-leakage reactanceThe Coil End Leakage ReactanceThe peripheral leakageBecause relatively few stators or rotors are skewed, the leakage reactance caused by either a skewed stator or skewed r
12、otor will not be considered. It is sufficient to know that an additional leakage reactance exists for skewed motors.Reactance 3 and 4 are sometimes combined and called Differential LeakageStator Slot Leakage ReactanceT = Reactance FactorL = Length of stator coreS = # stator SlotsKs = Factor to accou
13、nt for coils of different phases being in the same slot1 = Permeance Factor of Stator Slot Based on slot geometry For Stator:For Rotor:Rotor Slot Leakage ReactanceXSR = Rotor Slot Leakage Reactance Referred to the StatorT = Reactance FactorL = Length of rotor coreR = # rotor SlotsKw = stator winding
14、 factor2 = Permeance Factor of rotor slot Based on slot geometry Rotor Leakage Reactance Cont.The value of XSR is effected by the operating condition of the motor. The value calculated is for “running conditions when rotor frequency is 1-2 Hz and rotor current is relatively low. During running condi
15、tions, the rotor bar current can be though of as distributing evenly throughout the bar. During locked rotor, the rotor frequency is 60 Hz and due to the “Deep Bar Effect the current crowds toward the top of the bar. The current crowding along with the saturation effects of the high inrush current c
16、ause the starting value of XSR to be significantly reduced. Differential LeakageBesides the fundamental air gap flux wave form there are harmonic wave forms that are multiples of the number of poles and rotate at sub-multiples of synchronous speed. These harmonics induce voltages in the windings tha
17、t produced them and therefore add to the reactance of the winding.The differential leakage is sometimes broke into two components: The zig-zag and phase belt leakage. The following notation combines the belt leakage with the zig-zag.XM = Magnetizing ReactanceS= # Stator SlotsP = # PolesR + # Rotor S
18、lotsKgS Carters airgap coefficient for the statorKgR Carters airgap coefficient for the rotorKS Short Pitch Correction FactorKW Stator Winding Correction FactorCoil end Leakage ReactanceStatorRotorAS = Mean stator overhangAR = Mean Rotor OverhangAS = Mean Stator overhangL.M.H.T. = Length of mean hal
19、f turn stator coilL = Stator core length = per unit coil pitch = Pole PitchKS = Short pitch correction factorPeripheral Air Gap LeakageLines of flux that enter the air gap but do not link the rotor but instead flow peripherally back into the stator. If we imagine a induction motor with the rotor rem
20、oved, all the flux in the stator bore will be of this air leakage character.D = Stator I.D.g = Single air gapPeripheral reactance is negligible for induction machines with small air gaps but can be relevant on high speed synchronous motors with very large air gaps.Consider a 4 pole induction motor,
21、800 frame with D=32.75 and g=.175: XP/XM = .00091Consider a 4 pole synchronous motor, 800 frame with D=33.5 and g=1.0: XP/XM = .028 Summary of Induction Motor Leakage ReactanceXSS = Stator slot leakage reactanceXRS = Rotor slot leakage reactanceXZZ = differential leakage reactance (Zig-Zag + Belt Le
22、akage)XES = Stator End Winding Leakage ReactanceXES = Rotor End Winding Leakage ReactanceX2 = XSR +XZZ + XERX1 = XSS +XZZ + XESLeakage Reactance Summary Continued The Leakage reactance varies as the square of effective conductors or turns per phase. If the number of stator slots and the number of parallel circuits are not changed, it varies as the square of the number of turns per coilIn Order to decrease the leakage reactance do one or more of the following: Decrease the stator bo
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2024年期墓園土地使用協(xié)議
- 2024年二手挖掘機交易協(xié)議模板
- 不銹鋼工程承建2024協(xié)議規(guī)范稿
- 2024年度汽車金融貸款擔(dān)保服務(wù)協(xié)議
- 戶外執(zhí)行合同范本
- 貨車轉(zhuǎn)讓合同范本
- 城市居民供水服務(wù)協(xié)議2024樣本
- 2024屆廣東深圳羅湖外國語學(xué)校高三第三次診斷考試數(shù)學(xué)試題文試題
- 空調(diào)oem合同范本
- 監(jiān)測井合同范本
- 職業(yè)道德練習(xí)試題及答案
- 文字崗位類面試題目及答案
- 拒絕網(wǎng)絡(luò)暴力班會課件
- 營銷人員成長提升計劃
- 質(zhì)量管理制度及過程控制措施
- 光伏并網(wǎng)前單位工程驗收報告-2023
- 幽門螺旋桿菌治療指南課件
- 工程造價咨詢廉潔和守信制度
- 墻體脫落維修整改計劃書
- 音樂學(xué)科家長會
- 《云計算技術(shù)及應(yīng)用》期末試卷二(含答案)
評論
0/150
提交評論