1、Thank you for purchasing BTS-6082E total station of BOIF. The Bad maintenance decreases its accuracy and shortens its service life, even affects normal measuring work. To get the best use of the instrument, please carefully read this instructions and retain it for future use.1 / 174Catalogue1. Nomen

2、clature and function -61.1 Nomenclature-61.2 Display -81.3 Operating keys-101.4 Function keys(F1F4)-111.5 RS232-C data interface-172. Preparations -182.1 Leveling the instrument-182.2 Power switch on -202.3 Battery level -212.4 Vertical inclined corrected-222.5 Input the letter and the data-232.6 Me

3、nu content -283. Standard measuring mode -283.1 angle measuring -293.1.1 level angle and vertical angle -293.1.2 alternation of HR/HL-313.1.3 setting the horizontal plate reading -3 setting the horizontal plate reading -3 input the horizontal angle -323.1.4 conversion between the ver

4、tical angle and the slope angle -343.1.5 vertical angle mode change -353.1.6 change the unit of the angle -363.2 distance measurement -363.2.1 star key mode -3 setting the atmospheric constant -3 setting the prism constant -3 illumination ON or OFF -393.2.2 setting the sound

5、mode -403.2.3 distance measuring -413.2.4 distance measuring mode -423.2.5 stakeout measuring -443.2.6 change the distance unit -463.3 coordinate measuring -473.3.1 set the height of the prism / backsight coordinate / instrument station point -4 setting the prism height -4 setting th

6、e instrument station -50 setting the backsight -513.3.2 the operation of the coordinate measuring -534. Program mode -554.1 collection the data -554.1.1 select a file -5 found a new file -5 transfer a file in the memory -604.1.2 the instrument station and the backsight -624.1.

7、2.1 setting the instrument height -6 setting the instrument station ( use the data in the memory ) -6 setting the backsight -664.1.3 collect the data of the unknown point -694.2 layout measurement -714.2.1 layout step -714.2.2 the operation step -714.3 application measurement -764.3.

8、1 REM measuring -7 with a prism height (REM) -7 without prism height (REM) -794.3.2 substense measuring (MLM) -804.3.3 offset measuring -835. memory management -875.1 display the memory status -895.2 refer the data -905.3 file management -915.3.1 change the file name -915.3.2 check t

9、he data in the file -945.3.3 delete the file -965.4 input the coordinate data -975.5 delete the coordinate data -1005.6 the data communication -1025.6.1 send out the data -1025.6.2 incept the data -1045.6.3 setting the parameter of the communication-1065.7 initialize the memory -1086. adjustment mod

10、e -1096.1 adjust the system -1096.1.1 adjust vertical angle -1096.1.2 level angle setting -1106.2 setting the instrument constant -1127. setting the parameter -1137.1 the minimum reading of the angle -1147.2 the auto off setting -1157.3 set the parameter automatically -1168. batteries and charge it

11、-1179. datachment and attachment the tribrach -11810. check and adjustment -11910.1 check and adjustment the telemeter constant -11910.2 check and adjustment the axis of the instrument -12110.3 the thodolite -12210.3.1 check and adjust the plate level -12310.3.2 check and adjust the circular level -

12、12410.3.3 check and adjust vertical cross-hair -12510.3.4 collimate the instrument -12710.3.5 check and adjust optical plummet -12911. the error news -13112. technical data -132 Nomenclature and function 1.1 NomenclatureCarrying handleBattery caseKeys Foot screwBaseOptical plumentCenterEyepiece Base

13、 locking levelHandleFocusing knob Sighting collimatorCircular levelLate levelVertical fix/motion clampObjective lensDisplayHorizontal fix/motion clamp 1.2 Dispiayl Display windowsThe display use the lattice display (LCD), it can display the English and the numbers bytes. On the top three row display

14、 the observing data, the bottom row display the function of the instrument, it update with the measuring mode.For example:V : 90°1020HR: 120°3040SD HD NEZ OSET P1HR: 120°3040HD: 65.432mVD:12.345m FMEAS VH HD NEZ P1Angle measuring (page 1) Distance measuring (page 1)Vertical angle: 90&

15、#176;1020 Level angle: 120°3040Level angle: 120°3040 Level distance: 65.432m Vertial difference :12.345mN : 123.456mE : 34.567mZ : 78.912mSGMEAS VH SD HD P1BTS-6000Prog Std Mem Adj ParaCoordinate measuring (page 1) menu mode (page 1)N(north coordinate): 123.456m come in program E(east coor

16、dinate): 34.567m settingstandard Z(zenith coordinate):79.912m measurmentmemory managementadjustment Basic setting mode layout memory l Display marksDisplayFunctionDisplayFunctionVVertical anglemmeterHRHorizontal angle rightftFeetHLHorizontal angle left%Percent gradeHDLevel distance dHDThe horizontal

17、 stakeoutVDVertical differencedVDThe difference vertical stakeoutSDDeclining distancedSDThe incline distance range stakeoutNNorth coordinate°360°EEast coordinateg400gZZenith coordinatePSMPrism constantPPMAtmosphere constant1.2 Operating key Key operationNameFunctionStar keyThe illumination

18、 ON or OFFsetting the prism constant and the atmosphere constantPower switchPower on or offF1F5Function keys Please see the display newsESCexitReturn to the measuring mode or the front modeTurn the page In the file or the data form Moving Setting the baut rate moving09Number keys Input the numberAZL

19、etter keys Input the letters _/exitInput the sign1.4 Function key (F1F4)The information is on the bottom of the display windows, press the function keys, the order will be performed.V: 90°1020HR: 120°3040SD HD NEZ OSET P1 Angle measuring modePage KeyDisplay marksFunction1F1Incline distance

20、Come in the incline distance measure modeF2Level distanceCome in the level distance measure modeF3CoordinateCome in the coordinate measure modeF4OsetLevel angle o settingF5P1Display the page 22F1HOLDHold the level angle F2HSETInput the level angle from the number keysF3R/LHR or HLF4%VChange between

21、the vertical angle /gradeF5P2Display the page 33F1TILTSetting the tilt ON/OFFF2CMPSThe vertical angle change between the zenith and the vertical angleF3D/GChange between the DEREE/GONF5P3Display the first page 1Incline distance measuring modeV: 90°1020Hr: 120°3040SD:12.345m FMEAS VH SD NEZ

22、 P1PageKeyDisplay marksFunction1F1MEASCome in the incline distance measuring F2AngleCome in the angle measuring modeF3Level distanceCome in the level measuring modeF4CoordinateCome in the coordinate measuring modeF5P1Display the page 22F1ModeSetting the measuring mode (precision /tracking /single /

23、quick measuring )F2signalSetting the prism constant/ atmosphere, sound modeF3S.OChoose the stakeout modeF4M/ftChange from m to ft F5P2Display the page 1Level distance measuring modeHr: 120°3040HD:12.345m FVD: 0.566m FMEAS VH SD NEZ P1PageKeyDisplay marksFunction1F1MEASlevel distance measuring F

24、2AngleCome in the angle measuring mode F3Incline distance measuringCome in the incline distance measuring modeF4CoordinateCome in the coordinate measuring modeF5P1Didplay the page 22F1MODEChange among the incline / level / vertical difference distance F2SignalSetting the signal /prism constant/ atmo

25、sphere, sound modeF3LayoutCome in the layout measuring modeF4M/ftChange from m to ftF5P2Display the page 1Coordinate measuring modeN: 123.456mE: 34.567mZ: 79.912mMEAS VH SD HD P1PageKeyDisplay marksFunction1F1MEASCome in the incline measuring modeF2VHCome in the angle measuring modeF3SDCome in the i

26、ncline distance measuring modeF4HDCome in the level distance measuring modeF5P1Display the page 22F1MODEChange among the incline / level / vertical difference distance F2SignalSetting the signal /prism constant/ atmosphere, sound modeF3SETSet the height of theprism/backsight/instrument stationF4M/ft

27、Change from m to ftF5P2Display the page 11.5 RS232-C data interfaceRS232-C data interface connect the total station and the conputer or the PDA , so you can send the data to the computer or the PDA or you can send the coordinate data to the total station. 2 Preparations2.1 Level the instrument 1) Pl

28、ace the tripodFirst, put the tripod leg in the proper position and tighten the locking screws. 2) Attaching the instrument to the tripod headPlace the instrument carefully on the tripod head, and move the instrument slowly by loosening adjusting screw. Align the plumb bob with the point on the groun

29、d. When aligned, tighten the adjusting screw. 3) Initial rough leveling the instrument with circular level a) Use leveling screws AB to move the bubble of the circular level until the bubble of the circular level until the bubble is now located on a line perpendicular to a line running through the c

30、enters of the two leveling screws being adjusted.b) Revolve the leveling screw C to shift the bubble to the center of the circular.4) Further leveling the instrument with plate level a) Loosen horizontal motion clamp and revolve the instrument. By adjusting leveling screws AB, the plate level vial i

31、s parallel to a line running through the centers of two leveling screws, and place the bubble in the center of the level vial.b) Next, revolve the instrument 90°(100g) around its vertical axis and use the remaining screw C to center the level bubble once more.c) Repeat the above procedure for e

32、ach 90°revolution of the instrument and check whether the level bubble is correctly centered for all points.5) Centering the instrument with optical plummetAdjust the eyepiece of the optical plummet telescope to the users eyesight. Move the instrument by loosening adjusting screw. Coincide imag

33、e of the point on the ground with the center mark of the optical plummet telescope. Carefully move the instrument in order to make it steady.The centerThe instrument point 6) Final leveling of the instrument Repeat procedure of d. and check whether the level bubble is in the center of the level vial

34、. Finally tighter adjusting screw.2.2 Power switch on 1. Push the power switch on. All segments of the display will light for about 2 seconds. Rotate the telescope and it will hint set the vertical angle 0 (rotate the telescope and preparing to measuring).2. Rotate the telescope to set the instrumen

35、t to a vertical angle reading 0.Power on BOIFV4.8e V indexRotate telescopeTurn the telescope !V : 90°1020HR : 0°0000SD HD NEZ OSET P1l In order to make sure instrument work continuously, pay attention to battery display. If battery is insufficient, replace battery or to charge it. Please s

36、ee 2.3 Battery display.2.3 Battery level Battery mark in the display indicates the power condition.V : 90°1020HR: 0°0000 SD HD NEZ OSET P1We can see the battery, when the mark is glint, the battery is used up. We should stop and change a new one or charge it. Note: a. Please see 8 batterie

37、s and charge it. b. The battery is connection with the measuring mode. the battery in the angle measuring mode is bigger than in the distance measuring mode. So there is normally the instrument can work in the angle measuring mode, but not in the distance measuring mode.2.4 Vertical inclined correct

38、edThe inline on the X axisThe zenith modeWhen the compensator is working, it can self-motion compensate the incline angle. In order to ensure the precision of the angle, we must set the TILT on.If it display the TILT OVER , it say incline over the compensate arrange. We must level the instrument.Not

39、e: When you meet the gale or the quiver surrounding, the angle display is not stabilization. You should close the compensate before you measure it.Setting the incline correction with the software.For example :Setting the compensator (inclined angle of the vertical axis) is off.Operating procedureOpe

40、ratingDisplayV : 90°1020HR : 120°3040TILT CMPS D/G P3TILT SENSOR OFFON OFF ENTTILT SENSOR ONON OFF ENTV : 90°1020HR : 120°3040TILT CMPS D/G P31. In the angle measuring mode, Press F5(P1) twice, we can see page 3.2. Press F1(TILT), it display the TILT off.3. Press F1 (ON), the com

41、pensator is ON.4. Press F5(ENT), return.F5F1F1F5Input the letter and the dataYou can input the letter and the data, eg. File name/identifier/point name/instrument height/prism height/instrument station point coordinate and backsight coordinate, ect.When you input the data(angle /coordinate /instrume

42、nt height, you can input it directly.Whne you input the sign(file name /point name /sign), you can use “AZ” and “F1F5”, select the number /letter and the sign. Input the data (input the level angle through the keyboard)Operating procedureOperatingDisplayV: 90°1020HR : 120°3040SD HD NEZ OSE

43、T P1V: 90°1020HR : 120°3040HOLD SSET R/L V% P2H-SETHR:INP ENTH-SETHR: ENT1. Angle measuring mode.2. Press F5 (P2), come in page 2.3. Press F2(HSET), you can input the angle data. 4. Press F1 (input) .F5F2F15. Press “2” ”0” ”.” ”4” ”0”.6Press F5(ENT), finish it.F5H-SETHR: 120°3040ENTV:

44、 90°1020HR : 20°3040HOLD HSET R/L V% P1When you input the angle data, you should add a point “.” between the degree and the minute. Between the minute and the second dont need it. After you input it , it will display the degree, minute and the second.Input the letter (in the collect data mode, input the file name BOIF)Operating procedureOperatingDisplaySELECT A FILEFNINP LIST ENTSELECT A FILE FNENTSELECT A FILE FN 7 A B C ENTSELECT A FILE FN: B ENTDAT

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

最新文檔

評(píng)論

0/150

提交評(píng)論