更換SSA RAID陣列中硬盤的步驟.doc_第1頁
更換SSA RAID陣列中硬盤的步驟.doc_第2頁
更換SSA RAID陣列中硬盤的步驟.doc_第3頁
更換SSA RAID陣列中硬盤的步驟.doc_第4頁
全文預(yù)覽已結(jié)束

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡(jiǎn)介

建了RAID的磁盤陣列在使用過程中可能會(huì)發(fā)生硬盤出現(xiàn)故障需要更換的情況,本文介紹了安全更換硬盤而不破壞數(shù)據(jù)的詳細(xì)步驟。1. 首先需要從RAID定義中邏輯上刪除故障硬盤。執(zhí)行下面的命令:# smit ssaraid- Change Member Disks in an SSA RAID Array- Remove a Disk from an SSA RAID Array2. 屏幕顯示出如下的陣列列表:Change Member Disks in an SSA RAID ArrayMove cursor to desired item and press Enter.Remove a Disk From an SSA RAID ArrayAdd a Disk to an SSA RAID ArraySwap Members of an SSA RAID Array-SSA RAID Array Move cursor to desired item and press Enter. Use arrow keys to scroll. hdisk6 -6010337B163E30K good -2.3GB -RAID-5 array hdisk5 -09523173A02137K good -2.3GB -RAID-5 array F1=Help -F2=Refresh -F3=Cancel F8=Image -F10=Exit -Enter=Do /=Find - n=Find Next -選擇要?jiǎng)h除的硬盤所在的陣列的名稱,在本例中選擇 hdisk6。3. 屏幕顯示如下的信息:Remove a Disk From an SSA RAID ArrayType or select values in entry fields.Press Enter AFTER making all desired changes.-Entry FieldsSSA RAID Manager -ssa1SSA RAID Array -hdisk6Connection Address / Array Name -6010337B163E30K* Disk to Remove -+F1=Help -F2=Refresh -F3=Cancel -F4=ListF5=Reset -F6=Command -F7=Edit -F8=Image F9=Shell -F10=Exit -Enter=Do 按下F4鍵,列出屬于該RAID陣列中的硬盤。 4. 硬盤列表顯示如下:Remove a Disk From an SSA RAID ArrayType or select values in entry fields.Press Enter AFTER making all desired changes.-Entry FieldsSSA RAID Manager -ssa1SSA RAID Array -hdisk6Connection Address / Array Name -6010337B163E30K* Disk to Remove -+-Disk to Remove Move cursor to desired item and press Enter. Use arrow keys to scroll. pdisk4 -0004AC50374D00D member -present -1.1GB -Physical pdisk5 -0004AC510D9100D member -present -1.1GB -Physical pdisk7 -0004AC510D9900D member -present -1.1GB- Physical F1=Help -F2=Refresh -F3=Cancel F8=Image -F10=Exit - Enter=Do /=Find - n=Find Next -從上面顯示的列表中選擇需要?jiǎng)h除的硬盤。5. 使用“Set service Mode”服務(wù)幫助將需要?jiǎng)h除的硬盤設(shè)置為維護(hù)模式。命令如下:# diag- Task Selection (Service Aids )- SSA Service Aids - Set Service Mode - (選擇硬盤)- Set or Reset Service Mode This will set the drive to service so the drive canbe replaced. You will see a prompt displayed nextto the drive listing when service is set.例:-pdisk0 -AC503429 -00-03-P -1GB SSA C Physical Disk Drive-pdisk1 -AC510D98 -00-03-P -1GB SSA C Physical Disk Drive-pdisk2 -AC510D91 -00-03-P -1GB SSA C Physical Disk Drive-pdisk3 -AC510D96 -00-03-P -1GB SSA C Physical Disk Drive-pdisk4 -AC50374D -00-03-P -1GB SSA C Physical Disk Drive pdisk5 -AC510D91 -00-03-P -1GB SSA C Physical Disk Drive-pdisk6 -AC510DBB -00-03-P -1GB SSA C Physical Disk Drive-pdisk7 -AC510D99 -00-03-P -1GB SSA C Physical Disk Drive6. 物理上拿掉故障硬盤。若不確定是那一塊,可以看到故障硬盤的電源燈旁的黃色檢查燈是亮的。7. 物理上安裝好替換的硬盤。8. 按照步驟5的方法將硬盤從維護(hù)模式設(shè)置回普通模式。 9. 邏輯上從系統(tǒng)中刪除舊的硬盤信息,再將新更換的硬盤配置起來:# rmdev -dl pdisk* (其中,pdisk* 為具體的硬盤號(hào),本例中為pdisk5。) # cfgmgr10. 下面需要將新更換的硬盤設(shè)置為陣列的候選盤:# smitty ssaraid- Change/Show Use of an SSA Physical Disk- - 選擇正確的 SSA Raid卡。從列表中選擇正確的硬盤 (屏幕顯示如下)-SSA Physical Disk Move cursor to desired item and press Enter. Use arrow keys to scroll. # SSA physical disks that are members of arrays. pdisk4 -0004AC50374D00D member -n/a -1.1GB -Physical pdisk7 -0004AC510D9900D member -n/a -1.1GB -Physical # # SSA physical disks that are AIX system disks. pdisk5 -0004AC510D9300D system n/a -1.1GB Physical F1=Help - F2=Refresh -F3=Cancel F8=Image -F10=Exit -Enter=Do /=Find -n=Find Next -Make sure the Current Use Parameter is set to Array Candidate Disk onthe next screen (listed below). Press Tab on Current Use to changeand then Enter to execute.Change/Show Use of an SSA Physical DiskType or select values in entry fields.Press Enter AFTER making all desired changes.-Entry FieldsSSA RAID Manager -ssa1SSA Physical Disk- pdisk5 CONNECTION address -0004AC510D9300D Current Use -Array Candidate Disk11. 將新更換的硬盤添加回RAID陣列中:# smit ssaraid- Change Member Disks in an SSA RAID Array - Add a Disk to an SSA RAID Array-選擇正確的RAID名稱,-按F4選擇硬盤按回車后,選擇的硬盤被加入到RAID陣列中,系統(tǒng)在該硬盤上自動(dòng)重建信息。12. 查看信息重建的狀態(tài):# smit ssaraid- List Status Of All Defined SSA RAID Arrays屏幕顯示如下:COMMAND STATUSCommand: OK -stdout: yes -stderr: noBefore command

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

最新文檔

評(píng)論

0/150

提交評(píng)論