XHCOD9005-B培訓(xùn)教材.doc_第1頁
XHCOD9005-B培訓(xùn)教材.doc_第2頁
XHCOD9005-B培訓(xùn)教材.doc_第3頁
XHCOD9005-B培訓(xùn)教材.doc_第4頁
XHCOD9005-B培訓(xùn)教材.doc_第5頁
已閱讀5頁,還剩52頁未讀 繼續(xù)免費閱讀

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認領(lǐng)

文檔簡介

XH9005-B型COD在線監(jiān)測儀XH9005-B型COD在線自動監(jiān)測儀培訓(xùn)教材河北先河科技發(fā)展有限公司目 錄1.概述42.功能與特點43主要技術(shù)指標53.1 COD技術(shù)指標53.2流量技術(shù)指標64儀器的測試原理65儀器的結(jié)構(gòu)及工作過程65.1結(jié)構(gòu)組成65.2工作流程:76操作說明96.1 單擊測試畫面鍵進入“測試畫面”106.3 單擊閥體監(jiān)視鍵進入“閥體監(jiān)視”畫面。116.5 單擊報警查詢鍵進入“報警查詢”畫面。136.6 單擊調(diào)試鍵系統(tǒng)進入“調(diào)試”畫面。156.6.1點擊時間參數(shù)調(diào)試進入時間參數(shù)設(shè)置狀態(tài)156.7.1 單擊時鐘鍵進入“設(shè)置時鐘”畫面167.1儀器運行基本條件207.2站房要求207.3配電要求217.4管路準備217.5巴歇爾流量槽概要237.7需用戶提前準備的物品298.現(xiàn)場操作298.1準備工作298.2配制試劑298.3將液體試劑和蒸餾水分別注入試劑瓶和蒸餾水箱,注完后請及時將瓶塞和箱蓋蓋好,液位不低于2/3箱高。328.4往冷卻箱中注入蒸餾水或自來水(自來水不影響冷卻效果,但會在管壁結(jié)水垢),液位不低于1/3箱高。328.5連接采樣管路。328.6連接主機污水排放管路,將其出口置于下水道。注意:排放口應(yīng)低于主機底板且廢液排放管不要超過2米。328.7連接廢液箱及主機進水管路。328.8連接信號線(適配器用)及電話線。328.9連接好主機電源。329系統(tǒng)調(diào)試329.1閥體的調(diào)試329.2 冷卻泵的調(diào)試33.3 其它部件調(diào)試339.4試劑計量管的調(diào)節(jié)339.5倒進樣計量杯調(diào)試349.6發(fā)射、接收光路調(diào)試349.7溫控儀的調(diào)試359.8氣泵調(diào)試3899 2AD模塊的調(diào)試389.10 2DA模塊的調(diào)試399.11 高級調(diào)試4010運行4610.1 儀器運行條件4611.怎樣保證驗收通過4711.1保證儀器的高度穩(wěn)定4711.2 加強質(zhì)控手段4711.3 實際水樣的測定4812. 日常維護4813故障報警及分析49131. 如何判斷電磁閥的好壞?50132“AD值=0”:51133 哪些原因會導(dǎo)致COD值異常偏高?5113.4 消解器溫度超高:5113.5儀器報警后怎樣處理?5213.6 光控計量失控如何處理?5213.7 何時檢查保險管?53附錄1 儀器示意圖54附錄2 主控電路板原理圖55附錄3561.概述COD即化學(xué)需氧量(Chemical Oxygen Demand),是指在一定條件下,水體中易被強氧化劑重鉻酸鉀(K2Cr2O7)氧化的溶解態(tài)或懸浮態(tài)還原性物質(zhì)所消耗重鉻酸鉀相對應(yīng)的氧的質(zhì)量濃度,以氧的毫克/升來表示?;瘜W(xué)需氧量被廣泛地應(yīng)用于污水中有機物含量的測定,是評價水體污染程度的重要參數(shù)。2.功能與特點2.1 采用可編程控制器做控制核心,抗干擾能力強,運行可靠,自動控制系統(tǒng)平均無故障運行時間15萬小時,保障了長期在線監(jiān)測。2.2 采用光控計量結(jié)構(gòu),計量精度高,重復(fù)性好。2.3 采用大通徑防腐電磁閥,抗堵能力強,耐腐蝕,壽命長,可靠性高。2.4 采用特殊合成試劑,能有效地縮短消解時間,抑制氯離子干擾。該合成試劑為固體瓶裝,便于攜帶,易于運輸,并且配制簡單,價格低廉。測試周期短,僅為18分鐘,從而保證了環(huán)境監(jiān)測現(xiàn)場應(yīng)急測試的需要。2.5 采用全循環(huán)采樣方式,使采集的樣品具有實時代表性。2.6 采用彩色液晶觸摸屏,實現(xiàn)了監(jiān)視、控制一體化,儀器工作狀態(tài)一目了然,且減少了機械故障點。2.7 具有流量測定功能,能夠顯示瞬時流量、COD濃度、COD排放總量(需安裝超聲波傳感器)。2.8 能進行標樣和零點校正,具有自動清洗功能。2.9 通過網(wǎng)絡(luò)實時的或成批的傳送測試數(shù)據(jù),可與“國家環(huán)境監(jiān)理系統(tǒng)”相連。2.10具有斷電保護與數(shù)據(jù)查詢、數(shù)據(jù)打印功能(需安裝打印機)。2.11 具有故障報警與故障保護功能。3主要技術(shù)指標3.1 COD技術(shù)指標1)測量范圍:量程可變10-150mg/L 和100-1500mg/L2)重現(xiàn)性:10%3)量程漂移:8%4)零點漂移:5mg/L5)測量誤差:5%(鄰苯二甲酸氫鉀試驗)6)實際廢水樣品比對實驗:15%(相對誤差絕對值的平均值)7)平均無故障時間:360h/次8)電壓穩(wěn)定性:109)絕緣阻抗:20M以上10)消解器控溫范圍:(1652)11)測量周期:18分鐘24小時可調(diào)12)信號輸出:模擬 0-10VDC或0-5VDC,0-20mA或4-20mA;數(shù)字 RS232或RS48513)采樣泵:吸程5米,揚程30米14)電源:220V AC 50Hz15)外型尺寸:6604001330(mm)16)重量:90kg17)整機平均功率:22OW3.2流量技術(shù)指標1)符合明渠污水流量計、液位計暫行技術(shù)要求規(guī)定2)流量范圍:10-4103米/秒(流量量程與配用堰槽有關(guān))3)流量誤差:與配用量水堰槽有關(guān) 與三角堰配用:1%3% 與矩形堰配用:1%5% 與巴歇爾槽配用:3%4% 與無喉道槽配用:4%5%4)超聲測距范圍:0.4(盲區(qū))2米5)測距精度:0.4%6)水位分辨力:1毫米4儀器的測試原理本儀器采用國標重鉻酸鉀法,通過恒溫器消解進行快速催化氧化還原反應(yīng)。水體中的污染物被氧化,同時鉻離子由六價被還原為三價。自動檢測系統(tǒng)通過分光比色測定鉻離子的濃度,計算出COD值,在顯示屏上顯示出來。5儀器的結(jié)構(gòu)及工作過程5.1結(jié)構(gòu)組成COD在線監(jiān)測儀由采樣系統(tǒng)(采樣泵、過濾器)、加液計量系統(tǒng)(計量管、計量池)、控制系統(tǒng)(PLC、溫控儀、閥體)、測試系統(tǒng)(分光、模數(shù)轉(zhuǎn)換)、數(shù)據(jù)存儲和顯示系統(tǒng)(觸摸屏)等部分組成。5.2工作流程:1)采樣泵根據(jù)預(yù)定的采樣模式,將水樣采入主機,輸送給進樣閥;進樣閥、加液計量系統(tǒng)在控制系統(tǒng)的控制下按比例加入水樣和試劑,并完成混勻、恒溫消解、冷卻等操作;測試系統(tǒng)通過對已消解、冷卻后的混合液進行測量、數(shù)據(jù)格式轉(zhuǎn)換,最終計算出COD值,送給數(shù)據(jù)存儲及顯示系統(tǒng)。2)儀器自動運行流程圖雙擊自動鍵,儀器進入自動運行狀態(tài)。為了對儀器進行保護,按自動鍵20秒后儀器才開始自動運行。初始化工作雙擊自動鍵進入“預(yù)備自動”狀態(tài)保護性延時20秒沖洗各閥,打開溫控儀延時22分鐘,等待溫度升至165進水樣、加試劑混勻消解10分鐘冷卻5分鐘比色、顯示結(jié)果測試周期是否到 N Y 注:COD的采水流程如下:6操作說明打開電源開關(guān),觸摸屏首先顯示標題畫面,5秒后進入主菜單:“功能菜單”。在功能菜單中,可切換到任意一畫面,各藍底黑字鍵均為觸摸鍵,輕輕一按便可進入相應(yīng)畫面。6.1 單擊測試畫面鍵進入“測試畫面”在測試畫面中,可觀察到系統(tǒng)時間、系統(tǒng)運行狀態(tài)、COD值的模擬顯示與數(shù)字顯示,上小時累計流量、本周期累計流量、總累計流量、總累計排放量。手動/自動鍵設(shè)為雙擊鍵,即在設(shè)定時間內(nèi)連續(xù)點擊兩次方可有效。其中手動轉(zhuǎn)換到自動狀態(tài)有20秒的延時,在20秒內(nèi),再雙擊手動鍵可返回手動狀態(tài),否則20秒后進入自動運行狀態(tài)。此延時用于開機保護、上電保護。上小時流量指上小時0分0秒到上小時59分59秒的流量累積值,用于表征小時流量,周期累計流量為本測試周期內(nèi)的流量累積值,在下一周期開始時自動復(fù)零。6.2 單擊按鍵監(jiān)控鍵進入“按鍵監(jiān)控”畫面此畫面主要用于手動調(diào)試。每個黃底黑字鍵都對應(yīng)著儀器的一個部件,在手動狀態(tài)下,按動哪個鍵,對應(yīng)的閥體或部件動作,同時此鍵背景由黃變紅。在自動運行狀態(tài),此畫面只能觀察到哪個部件在動作,不能對其進行控制。其中溫度到163度鍵用于在自動運行時,消解器溫度已達到163,而延遲等待時間還未到22分鐘的情況下加快測試流程。1ml試劑指有顏色的氧化劑。6.3 單擊閥體監(jiān)視鍵進入“閥體監(jiān)視”畫面。在閥體監(jiān)視畫面中,可觀察到整個流程,各個閥體及部件運行狀態(tài)、液面動向、流程位置、流程時間等。例如消解閥,當水樣與試劑混勻后進入消解閥,右側(cè)“消解”鍵由藍變紅,同時,時間從0秒開始計時;左側(cè)的時間圓盤紅色逐漸增多。到10分鐘后,“消解”鍵變藍,時間增到600.0秒,時間圓盤全部變紅,消解結(jié)束。6.4 單擊測試查詢鍵進入“測試查詢”畫面。單擊返回,畫面回到功能主菜單。6.4.1單擊顯示結(jié)果(清單)可查閱測試數(shù)據(jù)及相應(yīng)時間。最新數(shù)據(jù)顯示在最前排,可保存1000個數(shù)據(jù),超過1000組最舊數(shù)據(jù)將被會覆蓋,請及時記錄所需數(shù)據(jù)。在“結(jié)果清單”畫面中,單擊次數(shù)鍵,可快速修改查詢次數(shù)。6.4.2單擊清除數(shù)據(jù)按照下一級提示可清除歷史數(shù)據(jù)。數(shù)據(jù)清除不能單獨清除某一組數(shù)據(jù)。6.5 單擊報警查詢鍵進入“報警查詢”畫面。6.5.1按報警狀態(tài)鍵,可查閱當前報警的狀態(tài)與詳細說明。當出現(xiàn)警報時,儀器自動保護,蜂鳴器鳴叫。“報警狀態(tài)”畫面相應(yīng)代碼條與詳細鍵變?yōu)榧t色。工作人員須排除相應(yīng)故障后,按報警復(fù)位鍵,儀器才能轉(zhuǎn)入正常工作。6.5.2按報警記錄顯示報警的時間與代碼。儀器總共能保存30次報警記錄。6.5.3“報警總計”顯示各類報警總共出現(xiàn)的次數(shù)。6.5.4“清除記錄”可清除儲存的報警記錄與報警總計。6.6 單擊調(diào)試鍵系統(tǒng)進入“調(diào)試”畫面。6.6.1點擊時間參數(shù)調(diào)試進入時間參數(shù)設(shè)置狀態(tài)在此畫面中,可對進樣時間、蒸餾水時間、吹氣時長等時間參數(shù)進行設(shè)定。出廠前已調(diào)試設(shè)置好參數(shù),只有當進行重新調(diào)試或測試結(jié)果誤差較大、進樣異常等情況下,才能修改這些參數(shù)。它們的修改,將影響測量結(jié)果、應(yīng)非常慎重。修改某參數(shù)時,按動該鍵,光標停于該項后的數(shù)值上,再利用屏幕下方數(shù)字鍵鍵入修改值,按ENT鍵確認修改或CLR鍵取消修改。注:1、“消解時間”、“冷卻時間“均可根據(jù)需要修改;2、“比色開始”是指從“冷卻閥”第一次排空開始計時,所設(shè)置的時間到后開始采集數(shù)據(jù);3、“比色結(jié)束”也是從“冷卻閥”第一次排空后開始計時,所設(shè)置的時間到后開啟“比色閥”,比色結(jié)束;4、“鼓泡時長”是指總共的鼓泡時間;5、“鼓泡間隔”指兩次鼓泡動作的時間間隔(最多可以連續(xù)鼓泡6次);6、“AD偏差”指以上次的比色電壓值為基準值(第一次比較時以0為基準值),用這個基準值結(jié)合設(shè)定的“AD偏差”值得到所需的出值區(qū)間,如果當前的AD值在所得的區(qū)間內(nèi),按正常的流程運行;否則,延長一定時間(可設(shè))后,再次采集比色AD值,進行比較,直至當前的AD值在上次得到的區(qū)間內(nèi)為止。6.6.2點擊流量計調(diào)試進入時間流量計調(diào)試畫面?!叭斯y量液位”用于液位校準,將實測液位輸入后按“確認”鍵,10秒后“儀器測量液位”將做相應(yīng)變化。6.7按參數(shù)設(shè)定鍵進入“參數(shù)設(shè)定”畫面。6.7.1 單擊時鐘鍵進入“設(shè)置時鐘”畫面修改方法為:先按設(shè)置鍵,背景色由藍變紅,系統(tǒng)時鐘中止運行,需修改哪一數(shù)值,請按該數(shù),光標停于該數(shù)值上,利用屏幕下方數(shù)字鍵鍵入所需修改值,再按ENT鍵確認修改或按CLR鍵取消修改,最后按設(shè)置鍵恢復(fù)時鐘運行。6.7.2按背光設(shè)置設(shè)置背光燈狀態(tài)點擊所要選擇項,菜單鍵由藍變紅,點擊返回鍵,返回上一級菜單。選擇“背光燈10分鐘后關(guān)閉”,觸摸屏靜置10分鐘后背光燈將自動關(guān)閉,以此來延長背光燈的使用壽命(建議使用此方式);輕觸觸摸屏任一位置都可自動點亮背光燈。6.7.3按采樣周期設(shè)置采樣的周期 采樣周期是指本次進樣距下次進樣的時間間隔。按“測試周期”藍色觸摸鍵,光標停于周期數(shù)值上,利用屏幕左方數(shù)字鍵鍵入所需修改數(shù)值,按ENT鍵確認修改或CLR鍵取消修改。周期最低設(shè)定值為18分鐘,最大為1440分鐘. 特別注意:在自動運行過程中修改“測試周期”,如果由長周期改為短周期,請在周期指示小于“4”時修改,或轉(zhuǎn)換到手動狀態(tài)再進入自動運行,或關(guān)機再重新開機。否則儀器不能正常工作。 測試前采樣 指在下一個周期開始前幾分鐘開啟采樣泵,使管路中的水提前循環(huán)起來,以保證所采集的瞬時樣具有實時代表性。此值不應(yīng)小于3分鐘。6.7.4按雙擊時間設(shè)定雙擊時間按“雙擊時間:”右面藍色觸摸鍵,光標停于該項后的數(shù)值上,利用屏幕下方數(shù)字鍵鍵入所需修改數(shù)值,按ENT鍵確認修改或CLR鍵取消修改。如:雙擊時間設(shè)為1秒,表示在1秒內(nèi)連續(xù)點擊兩次手動或自動鍵,點擊方可生效。設(shè)定時間長短根據(jù)個人愛好而定。6.7.5 按打印方式鍵可設(shè)定自動/手動打印方式。不安裝打印機時將給出提示信息。6.8 按幫助查看幫助內(nèi)容其中,操作說明介紹了儀器的操作過程及各個界面的使用方法,公司簡介中介紹了本公司的發(fā)展歷史及開發(fā)的系列產(chǎn)品,報警說明中給出了報警狀態(tài)代碼含義和引起報警的故障原因。7.安裝7.1儀器運行基本條件1) 環(huán)境溫度:535。2) 相對濕度:85%。3) 電源電壓:AC220V(10%)4) 電源頻率:(501)Hz。7.2站房要求1) 站房整體結(jié)構(gòu)可分為:磚體結(jié)構(gòu)和彩鋼板兩種結(jié)構(gòu),可由客戶自行選擇。2) 據(jù)站房屋頂?shù)男螤顑x器站房可分為:尖頂房和平頂房兩種。在冬季多積雪、夏季雨量大的地區(qū)推薦采用尖頂房;其他地區(qū)可選擇平頂房。3) 站房內(nèi)部使用面積不少于12平方米,室內(nèi)屋頂高度不低于2.3米。4) 應(yīng)有水泥地基,地基高度尺寸(一般在300mm以上)必須保證在雨季不能有雨水灌入室內(nèi)。5) 室內(nèi)地面建議用全瓷地板磚鋪設(shè)。6) 站房窗戶外側(cè)必須安裝防盜網(wǎng),窗戶內(nèi)側(cè)安裝窗紗扇。7) 房頂及墻體接逢處不得有漏雨、滲水等缺陷。8) 當儀器站房建在空曠地帶時,儀器站房必須安裝避雷設(shè)施。9) 站房應(yīng)設(shè)有排風(fēng)扇等通風(fēng)設(shè)施,以防止腐蝕性氣體對儀器及操作人員造成危害。10) 站房內(nèi)最好設(shè)有實驗臺、洗手池、地漏等設(shè)施。11) 應(yīng)在建設(shè)初在指定位置將所需的采樣管、排水管、穿線管提前預(yù)埋好,并在管內(nèi)預(yù)穿鋼絲,以便穿引管線。應(yīng)保證排水通暢。12) 站房距采水點距離應(yīng)盡量的近,直線距離應(yīng)不大于15米,垂直落差不大于5米。13) 嚴禁在有易燃性物質(zhì)、易燃、易爆性氣體周圍建站房。儀器站房要遠離腐蝕性氣體,以確保安全。14) 室內(nèi)應(yīng)備有自啟動冷暖空調(diào),以保證儀器正常運行的環(huán)境。15) 室內(nèi)應(yīng)按“配電要求”提前做好供電系統(tǒng)。16) 如需使用電話線聯(lián)網(wǎng),應(yīng)提前將電話線引入室內(nèi),關(guān)做好信號防雷。17) 室內(nèi)應(yīng)備要必要的照明設(shè)備及開關(guān)。18) 選擇采樣點應(yīng)滿足以下條件:水樣具有代表性,對水質(zhì)變化反應(yīng)靈敏,距水源較近。7.3配電要求1) 站房內(nèi)最好采用三相五線供電,入室處裝有配電箱,配電箱內(nèi)連接入室引線應(yīng)分別裝有三個單相15A空氣開關(guān)作為三相電源的總開關(guān),并安裝電源過壓、過載和漏電自動保護裝置。A相配接3KW穩(wěn)壓電源,穩(wěn)壓電源輸出接兩個5孔220V/10A電源插座;B相用于空調(diào)、照明、排風(fēng)扇等。空調(diào)應(yīng)采用空調(diào)專用電源插座,并單獨從配電箱引線。C相接兩個5孔插座用于安裝施工、回流實驗設(shè)備供電。2) 供電系統(tǒng)不能與電機等大功率設(shè)備共用。3) 站房內(nèi)供儀器及空調(diào)使用的線路單股橫截面積不得小于4mm2。4) 所提供的電源應(yīng)有良好的接地,接地電阻小于4。5) 所有室內(nèi)線路走線采用PVC材料護線槽或護線管保護。7.4管路準備管路要求1) 管材應(yīng)選用優(yōu)質(zhì)PVC材料或聚氯乙烯材料,管路連接不應(yīng)有死角,應(yīng)用直通或45度彎頭,以便于穿引鋁塑復(fù)合管。2) 排水管應(yīng)有自然傾角,以便于廢水排出。3) 根據(jù)地區(qū)差別,預(yù)防管路在冬季凍結(jié),預(yù)埋管深度H要根據(jù)冬季地區(qū)冰凍厚度確定。如:石家莊H=0.7米,沈陽H=1.2米,哈爾濱H=1.5米。4) 對于裸露的管路,應(yīng)采用保溫棉、伴熱帶等保溫防凍措施。5) 進水管1通徑為50mm。管內(nèi)穿牽引鋼絲。掩埋部分加保溫棉。6) 排水管2通徑為75mm。掩埋時應(yīng)有自然傾角,以便于廢水排出。7) 進線管3、4、5,管內(nèi)穿牽引鋼絲。8) 6為自來水上水管。9) 預(yù)埋管的另一端應(yīng)留在流量槽后端附近7.5巴歇爾流量槽概要7.51流量測量原理1)測量原理:用明渠測流量時,在明渠上安裝量水堰槽。量水堰槽把明渠內(nèi)流量的大小轉(zhuǎn)成液位的高低。利用超聲波傳感器測量量水堰槽內(nèi)的水位,再按相應(yīng)量水堰槽的水位-流量關(guān)系反算出流量。7.5.2巴歇爾槽現(xiàn)場安裝平面示意圖(圖1)7.5.3 巴歇爾槽構(gòu)造(圖2)7.5.4巴歇爾槽構(gòu)造尺寸(表一)單位:米類別序號喉道段收縮段擴散段墻高bNB1L1LaB2L2KD 小 型10.0250.0760.0290.1670.3560.2370.0930.2030.0190.2320.0510.1140.0430.2140.4060.2710.1350.2540.0220.263 0.0760.1520.0570.2590.4570.3050.1780.3050.0250.4640.1520.3050.1140.4000.6100.4070.3940.6100.0760.6150.2280.3050.1140.5750.8640.5760.3810.4570.0760.77標準型60.250.600.230.781.3250.8830.550.920.080.8070.300.600.230.841.3500.9020.600.920.080.9580.450.600.231.021.4250.9480.750.920.080.9590.600.600.231.201.5001.00.900.920.080.95100.750.600.231.381.5751.0531.050.920.080.95110.900.600.231.561.6501.0991.200.920.080.95121.000.600.231.681.7051.1391.300.920.081.0131.200.600.231.921.8001.2031.500.920.081.0141.500.600.232.281.951.3031.800.920.081.0151.800.600.232.642.101.3992.100.920.081.0162.100.600.233.002.251.5042.400.920.081.0172.400.600.233.362.401.6042.700.920.081.0大型183.050.910.3434.764.271.7943.681.830.1521.22193.660.910.3435.614.881.9914.472.440.1521.52204.571.220.4577.627.622.2955.593.050.2291.83216.101.830.6869.147.622.7857.323.660.3052.13227.621.830.68610.677.623.3838.943.960.3052.13239.141.830.68612.317.933.78510.574.270.3052.132412.191.830.68615.488.234.78513.824.880.3052.132515.241.830.68618.538.235.77617.276.100.3052.135)巴歇爾槽水位-流量公式(表2)類別序號喉道寬度b(m)流量公式Q=Chan(L/S)水位范圍h(m)流量范圍Q(L/S)臨界淹沒度%最小最大最小最大小型10.02560.4ha1.550.0150.210.095.40.520.051120.7ha1.550.0150.240.1813.20.530.076177.1ha1.550.030.330.7732.10.540.152381.2ha1.540.030.451.50111.00.650.228535.4ha1.530.030.602.52510.6標準型60.25561ha1.5130.030.603.02500.670.30679ha1.5210.030.753.54000.680.451038ha1.5370.030.754.56300.690.601403ha1.5480.050.7512.58500.6100.751772ha1.5570.060.7525.011000.6110.902147ha1.5650.060.7530.012500.6121.002397ha1.5690.060.8030.015000.7131.202904ha1.5770.060.8035.020000.7141.503668ha1.5860.060.8045.025000.7151.804440ha1.5930.080.8080.030000.7162.105222ha1.5990.080.8095.036000.7172.406004ha1.6050.080.80100.040000.7大型183.057463ha1.60.091.07160.082800.8193.668859ha1.60.091.37190.0146800.8204.5710960ha1.60.091.67230.0250400.8216.1014450ha1.60.091.83310.0379700.8227.6217940ha1.60.091.83380.0471600.8239.1421440ha1.60.091.83460.0563300.82412.1928430ha1.60.091.83600.0747000.82515.2435410ha1.60.091.83750.0930400.87.6流量槽的選擇與安裝1) 根據(jù)本企業(yè)最大瞬時排水量查“表2”,確定需要選擇的流量槽“序號”。2) 根據(jù)所查到的槽號,按槽的最大寬度-“表1”中的“B1”規(guī)范排放的渠寬,既排水渠的寬度不能小于“B1”。3) 量水堰槽的中心線要與渠道的中心線重合,使水流進入量水堰槽不出現(xiàn)偏流。4) 量水堰槽通水后,水的流態(tài)要自由流。臨界淹沒度可在表2查得。既要求流量槽后的排水要通暢。5) 量水堰槽的上游應(yīng)有大于5倍渠道寬的平直段,使水流能平穩(wěn)進入量水堰槽。即沒有左右偏流,也沒有渠道坡降形成的沖力。6) 量水堰槽安裝在渠道上要牢固。與渠道側(cè)壁、渠底連結(jié)要緊密,不能漏水。使水流全部流經(jīng)量水堰槽的計量部位,量水槽的計量部位是槽內(nèi)喉道段。7) 巴歇爾槽水位觀測點在距喉道2/3收縮段長位置(圖2的La)。8) 巴歇爾槽安裝時應(yīng)保證圖2中水位零點處于水平狀態(tài)。9) 浮子采樣器可根據(jù)現(xiàn)場情況安裝的流量槽的上游或下游。7.7需用戶提前準備的物品1)必備:蒸餾水50L,分析純硫酸3000ml,5000ml大燒杯,玻璃棒500mm。2)應(yīng)備:刻度吸管10ml、5ml各一只,吸耳球一只,1000ml、250ml量筒各一只,、洗瓶各一個,容量瓶100ml需4個,防酸手套一付。8.現(xiàn)場操作8.1準備工作1) 整機檢查開機前對照產(chǎn)品裝箱單檢查各部件及配件是否完好、齊全。如損壞或短缺,應(yīng)及時修復(fù)或更換。注:不允許帶電拆裝設(shè)備。2)檢查各管路連接是否正確,連接是否可靠,管材是否與要求相符(注意區(qū)分氟膠管和硅膠管兩種材質(zhì))。3)檢查電源插座,應(yīng)符合左零右火的規(guī)范,并且地線接觸良好。8.2配制試劑試劑配制與分裝:(1) 為便于運輸和攜帶,所供試劑為固體試劑。(2) 配制操作請在通風(fēng)條件下進行,配制人員必須穿戴防酸服、防酸手套。配制前先請用蒸餾水將試劑瓶、計量器清洗干凈。注意:試劑配制好后,必須放置48小時,且在放置的過程中要搖動35次,以便試劑充分溶解混合。(3) 試劑分低濃度試劑和高濃度試劑兩種,每種試劑都分為A、B兩部分(詳見實際瓶包裝),包裝均為500個樣,配制方法如下:a) 低濃度試劑的配制方法:配制比例如下:固體試劑蒸餾水(ml)硫酸(分析純ml)A(純白色)02500B(棕白色)45050將固體試劑A(催化劑)全部放入5000ml試劑瓶中,加入2500ml 98%分析純濃硫酸,用玻璃棒攪拌均勻。將固體試劑B(氧化劑)全部放入1000ml燒杯中,加入450ml蒸餾水,然后緩慢加入50ml 98%分析純濃硫酸,用玻璃棒攪拌均勻。b) 高濃度試劑的配制方法:配制比例如下:固體試劑蒸餾水(ml)硫酸(分析純ml)A(純白色)02500B(棕白色)47030將固體試劑A(催化劑)全部放入5000ml試劑瓶中,加入2500ml 98%分析純濃硫酸,用玻璃棒攪拌均勻。將固體試劑B(氧化劑)全部放入1000ml燒杯中,加入470ml蒸餾水,然后緩慢加入30ml 98%分析純濃硫酸,用玻璃棒攪拌均勻。注意事項:(1)、本儀器使用的試劑具有強酸性、強氧化性,在操作本儀器時請配戴必要的防酸用具,謹防意外燒傷。(2)、嚴格按說明書所要求的比例配置。(3)、所用蒸餾水最低為二級蒸餾水,最好為重蒸餾水。因為蒸餾水對低濃度COD的準確性測量影響尤其明顯。(4)、添加蒸餾水與硫酸的次序不能顛倒,一定要先加蒸餾水再加硫酸。附:GB6682-1992分析實驗室用水規(guī)格8.3將液體試劑和蒸餾水分別注入試劑瓶和蒸餾水箱,注完后請及時將瓶塞和箱蓋蓋好,液位不低于2/3箱高。8.4往冷卻箱中注入蒸餾水或自來水(自來水不影響冷卻效果,但會在管壁結(jié)水垢),液位不低于1/3箱高。8.5連接采樣管路。8.6連接主機污水排放管路,將其出口置于下水道。注意:排放口應(yīng)低于主機底板且廢液排放管不要超過2米。8.7連接廢液箱及主機進水管路。8.8連接信號線(適配器用)及電話線。8.9連接好主機電源。9系統(tǒng)調(diào)試9.1閥體的調(diào)試1)將空氣開關(guān)、電源開關(guān)置于ON的狀態(tài),測量電源插頭L、N之間的電阻,應(yīng)在105歐左右。2)分別按進樣閥、蒸餾水、消解閥、冷卻閥、比色閥鍵,觀察相應(yīng)閥是否動作,閥芯應(yīng)活動自如,液體流動順暢,閥體密封可靠。注:當冷卻閥中有液體下排時,應(yīng)先將比色閥排空,以免比色閥溢出。9.2 冷卻泵的調(diào)試1)確認冷卻水箱內(nèi)已注入蒸餾水。按冷卻泵鍵,冷卻水應(yīng)從冷卻閥水套下端進入,上端排出。水流快速通暢,泵電機運轉(zhuǎn)平穩(wěn)無雜音。2)再按冷卻泵鍵,冷卻泵關(guān)閉。.3 其它部件調(diào)試)按溫控儀鍵,溫控儀打開,溫度顯示正常,并能將溫度控制在(1652)范圍內(nèi)。再按此鍵,溫控儀關(guān)閉。)按光度計鍵,光度計打開,光度計發(fā)光管亮。再按此鍵,光度計關(guān)閉。)按自吸泵鍵,自吸泵啟動,有水循環(huán)流經(jīng)管路,查看管路是否漏水,按進樣閥查看進樣是否順暢。再按此鍵,泵停止。9.4試劑計量管的調(diào)節(jié)1)雙擊手動按鍵,使儀器處于手動工作狀態(tài)。在“按鍵監(jiān)控”畫面中按1ml試劑鍵,1ml試劑閥(二位三通閥)動作,棕色氧化劑由試劑瓶緩緩注入計量管,當液面到達光電檢測位置后,試劑閥自動復(fù)位,1ml試劑由排液口排到消解閥中。2)調(diào)節(jié)計量板上控制1ml試劑 電位器W1,在無試劑的情況下,使發(fā)光二極管由滅到亮,由亮到滅,反復(fù)多次,滅與亮旋轉(zhuǎn)幅度最小,使精度最高,3)計量1ml試劑,按1ml試劑鍵,液體進入計量杯,調(diào)節(jié)槽型光藕位置,同時調(diào)節(jié)W1,使二極管亮,同時閥斷電,液體從排液口排出,這時計量板二極管燈滅,取樣匙接取從排液口排出的試劑,用移液管計量排出的量,一次排出液體的量應(yīng)為1.00.2ml。連續(xù)計量6次,最大變化輻度在0.05 ml。4)5ml計量杯調(diào)試 方法同3.3.1,計量范圍:50.5ml,最大輻度:0.1ml。9.5倒進樣計量杯調(diào)試在“按鍵監(jiān)控”畫面按進樣鍵,電磁閥打開,水樣從左邊進入計量杯,用量桶從左邊嘴子出口接取,計量范圍:2.30.3ml;計量六次,最大輻度:0.1ml。9.6發(fā)射、接收光路調(diào)試觀察發(fā)射二極管610nm、430nm發(fā)光顏色。用白色紙條置于比色池中部,應(yīng)能觀察到橙色光斑或藍色光斑,仔細觀察發(fā)射光是否直接對準接收光源,并且發(fā)射、接收管在同一水平位置。9.7溫控儀的調(diào)試9.7.1按溫控儀鍵,溫控儀打開;再次按鍵,溫控儀關(guān)閉(如下圖)。1)視窗、燈號說明PV-目前溫度及參數(shù)代號視窗SV-設(shè)定值及參數(shù)值顯示窗AT自動演算指示燈MA手動輸出指示燈A1第一組警報輸出指示燈A2第二組警報輸出指示燈C1第一組控制輸出指示燈C2第二組控制輸出指示燈2)按鍵說明 -切換下一組參數(shù)功能或按住五秒持溫計時timer reset -累加參數(shù)設(shè)定值 -遞減參數(shù)設(shè)定值 -移位鍵:按住5秒鐘可執(zhí)行自動演算YES.1模式,執(zhí)行中如需停止演算,按住5秒鐘即可停止 +-鍵一次,即可立刻回到主界面 +-鍵五秒,即可進入階層參數(shù),此時按或鍵可以選擇階層,再按鍵即可進入該階層9.7.1操作步驟: 1)按住+鍵5秒后進入SOFT LEVEL,或鍵選擇SOFT(斜率/緩啟動)階層,再按鍵即可進入該階層第一階段(LEVL)參數(shù)設(shè)置:(按使PV中的參數(shù)進行切換,按鍵進行移位,按或鍵進行設(shè)置,最后再按進行確認修改)- 第一組報警值: 設(shè)置為 160- 第二組報警值: 設(shè)置為1852) 通過連續(xù)按鍵,或鍵選擇PID(比例/積微分)階層,進入第二階段(PID)參數(shù)設(shè)置:(按使PV中的參數(shù)進行切換,按鍵進行移位,按或鍵進行設(shè)置,最后再按進行確認修改) - 第一組比例輸出: -積分時間:-微分時間: -第一組輸出周期: 15s (表示繼電器輸出類型)-第二組比例輸出:-加熱冷卻不感帶:此階段的參數(shù)設(shè)置需要輸入一組PID控溫較好的參數(shù),如果控溫性能不好,按步驟4)得到一組性能較好的參數(shù). 3)通過連續(xù)按鍵,或鍵選擇OPTI(操作)階層,進入第二階段(OPTI)參數(shù)設(shè)置:(按使PV中的參數(shù)進行切換,按鍵進行移位,按或鍵進行設(shè)置,最后再按進行確認修改) -選擇傳感器類型:D-PT (表示PT100)-單位選擇: -小數(shù)位數(shù):000.0 (表示1位小數(shù))-加熱或冷卻控制: rEv ( rEv表加熱,dir表示冷卻)-使用范圍下限: 0-使用范圍上限: 200 -第一組報警方式: 設(shè)置為 Hi (上限報警) -第二組報警方式:設(shè)置為 Hi (上限報警)-第一組警報不感帶: 0.1-第二組警報不感帶: 0.1-ON/OFF控制不感帶: 0.1-測定值偏差修正: 0 3) 連續(xù)按住鍵,5S后自動演算控制燈AT閃爍,使儀器開始自動演算得到一組較好PID參數(shù)。注意:儀器自動演算時間比較長,如果再連續(xù)按住鍵,5S后將結(jié)束自動演算功能。5)+鍵將返回到設(shè)定點。按或鍵將SV的值設(shè)置為165.0表示控制目標溫度為165。(4) 觀察溫控儀溫升,升溫應(yīng)平穩(wěn),控溫范圍在1652之間。(5) 關(guān)閉溫控儀,在流程電路板上改變鉑電阻跳線,重新開啟溫控儀,溫度顯示應(yīng)無明顯差別,控溫依然正常。9.8氣泵調(diào)試一、 在“按鍵監(jiān)控”畫面按氣泵鍵,用手感覺氣泵兩個出口有氣流。99 2AD模塊的調(diào)試 在“高級設(shè)定”畫面中選擇“使用流量計” 將直流穩(wěn)壓電源與主控板“25、26”端子相連,穩(wěn)壓電源的正極與端子“25”相連,穩(wěn)壓電源的負極與端子“26”相連。 調(diào)節(jié)直流穩(wěn)壓電源輸出,使輸出電壓為5.000V,在“數(shù)據(jù)記錄”畫面中觀察“AD1”,調(diào)節(jié)2AD模塊的“GAIN”電位器,使AD1的示值為4000。 調(diào)節(jié)穩(wěn)壓電源輸出,使輸出電壓為0.2500V,調(diào)節(jié)2AD模塊的“OFFSET”電位器,使AD1為200。 重復(fù)上述兩個步驟兩到三次。 調(diào)節(jié)使穩(wěn)壓電源輸出為2.500V,觀察AD1,應(yīng)在20005范圍內(nèi)。否則重復(fù)2、3步。9.10 2DA模塊的調(diào)試 在DA類型中選擇“2DA”。 將萬用表旋至電流檔(表筆插孔也做相應(yīng)變動),串聯(lián)一只250歐接于電路板的2DA-1兩接線端。 將“COD量程系數(shù)”設(shè)為4,將“當前值”設(shè)為1000,按啟動轉(zhuǎn)換,調(diào)節(jié)“CH1 GAIN”,使萬用表示值為20.00mA。 將“當前值”設(shè)為0,按啟動轉(zhuǎn)換鍵,調(diào)節(jié)“CH1 OFFSET”,使萬用表示值為4.000mA。 重復(fù)上述兩個步驟2至3次。 將當前值設(shè)為500,按啟動轉(zhuǎn)換,萬用表示值應(yīng)在12.0000.005mA。否則重新調(diào)節(jié)。.1.1.1 流量值的2DA調(diào)試 在DA類型中選擇“2DA”。 將萬用表旋至電流檔(表筆插孔也做相應(yīng)變動),串聯(lián)一只250歐接于電路板的2DA-2兩接線端。 啟動“人工轉(zhuǎn)換”鍵使流量DA輸出處于人工轉(zhuǎn)換狀態(tài)。 將“20mA流量值”暫設(shè)為1.0000000m3/s。(到現(xiàn)場與適配器相連時需根據(jù)流量槽的最大流量值進行修改,)。 將“當前流量”設(shè)為1.000000m3/s,按啟動轉(zhuǎn)換,調(diào)節(jié)“CH2 GAIN”,使萬用表示值為20.00mA。 將“當前流量”設(shè)為0.000000m3/s,按啟動轉(zhuǎn)換鍵,調(diào)節(jié)“CH2 OFFSET”,使萬用表示值為4.000mA。 重復(fù)上述兩個步驟2至3次。 將當前值設(shè)為0.5000000m3/s,按啟動轉(zhuǎn)換,萬用表示值應(yīng)在12.0000.005mA。否則重新調(diào)節(jié)。 按“人工轉(zhuǎn)換”鍵取消人工轉(zhuǎn)換,恢復(fù)正常輸出。 調(diào)試完畢。其它說明:1)、與適配器相連時,2DA-1、2DA-2接線端子左為“+”是420mA的正極輸出,接適配器的“+”端。另一端為“-”,接適配器的“-”。2)、在現(xiàn)場與適配器相連時,如果萬用表的電流檔損壞,可先用萬用表測量適配器420mA輸入端電阻,用測量電壓的方式計算電流輸出。3)輸出電流值=(當前值/滿量程值)16+4mA9.11 高級調(diào)試9.11.1數(shù)據(jù)記錄 AD1第一路AD的實時值,每0.1秒轉(zhuǎn)換一次,代表液位的高低。如果安好超聲波液位計,則AD=(h測+0.2)4000h測=(AD/40000.2)m AV代表100個AD1的平均值。注:必須在高級設(shè)定中啟動“使用流量計”AD1才有效。 系統(tǒng)時間當前時刻。 修正前值與真實COD值有著線性關(guān)系的中間變量,從一定意義上代表吸光度。 修正后值指修正前值按照設(shè)定的線性公式計算后得到的值,代表COD值,與測試畫面中顯示的當前COD值相同。當啟用平滑時,因經(jīng)過線性計算后的COD值又經(jīng)過了平滑計算,可能會出現(xiàn)修正后值不按線性走的現(xiàn)象。 測試AD1上次的“測試AD”記錄值; 測試AD2指當比色閥中有測試液體時的AD值,代表比色閥中有測試液時的透光強度,此值越大,說明透光強度越大,COD值越小。 校百AD當比色閥中為蒸餾水(COD值為0,光100%通過)時的AD值,此值應(yīng)該是一個比較大且穩(wěn)定的值,當此值出現(xiàn)較大波動時,說明比色閥需要清洗,或者發(fā)射、接收孔的相對位置不在同一水平面。 實時AD啟動AD轉(zhuǎn)換時(主機自動啟動或人為強制啟動)第二路AD的實時值(代表光度計透光強度)。AV代表100個實時AD的平均值。在測試狀態(tài),此平均值賦給“測試AD”,在校百狀態(tài),此平均值賦給“校百AD”。 啟動AD轉(zhuǎn)換人為強制進行AD轉(zhuǎn)換,在進行轉(zhuǎn)換前,在比色池放入蒸餾水,啟動AD轉(zhuǎn)換,調(diào)節(jié)光度計板的電位器W1,使數(shù)據(jù)記錄界面上實時AD顯示3300。 中止記錄用于在現(xiàn)場給用戶做線性標定時,為防止用高濃度標液標定時,數(shù)據(jù)記錄中記錄下高濃度COD值,給用戶帶來不必要的麻煩而設(shè)計。啟用此鍵后,數(shù)據(jù)將不再記入數(shù)據(jù)記錄。9.11.2線性校正9.11.2.1畫面介紹由于儀器特點、測量方法及水樣多樣性等問題,造成標液線性與實際水樣線性不一致。由此產(chǎn)生了標液線性與水樣線性兩種線性。在圖中的三條線性中,每條線性都可獨立使用,第一、二線性還可同時使用(后面有詳細介紹)。一般將第一、二線性作為水樣線性,將第三線性作為標樣線性。儀器按哪條線性計算,由哪條線性底色為紅色決定。下面以第三線性為例介紹區(qū)間、線性、上下限的確定。9.11.2.2 a3、b3的確定在“數(shù)據(jù)記錄”畫面中啟用“人工測試”,測試周期設(shè)為20分鐘,采樣方式設(shè)為“測試前采樣”,在“按鍵監(jiān)控”畫面中雙擊“自動”鍵進入自動運行狀態(tài)。第一次加入標液是在溫控儀溫度到165后,空白樣進入冷卻閥前添加,加液方法為:用移液管將34ml標樣加入到水樣計量池中。此后的加液在整個測試過程完成(比色閥排空)后,下一個周期啟動前添加。添加后注意觀察水樣計量池是否能將多余的水樣溢流出去。在每次測量完畢,請將修正前值、測試AD、校百AD如實記錄,并記錄加入的標樣值,填入“調(diào)試記錄”中。要求每種標樣至少測量三次。數(shù)據(jù)處理如下:(在數(shù)據(jù)處理前應(yīng)將明顯的粗大誤差值去除)修正前值149168211344560152169214341558147166213

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論