1.Consideralargemodern(15000-kpa)steamgeneratorfiringpulverizedcoal.Explainin
detailhowthehotgasesgiveuptheirheatinpassingfromthefireballinthefurnacetothe
stackexit.Indicateinyourexplanation,thevariouspartsoftheunitcontactedbythegases
intheircorrectsequence.(15marks)
ANSWER:
2.List5characteristicsoffueloilthatmustbeconsideredwhenselectingapowerplantfuel.
Explainhowtheseimpactontheoperationoftheplant.(15marks)
ANSWER
A.THESPECIFICGRAVITY
-enablestheengineertodetermineiftheoilislightorheavy
-generallythehigherthespecificgravity,thelowerthehydrogencontentandtheharderit
istoignitethefuel
-lightfueloilavoidsthecostofkeepinganoiltankwarmed
-heavyfueloilsarethecheapesttopurchasebutitbecomescriticaltoknowthewater
contentoftheheavyfueloil.Someheavyfueloilsrequiretobeheatedtoashighas135
degreesCattheburnersupplybeforetheywillbumcompletely
B.THEHEATINGVALUE
-isrequiredtobeknown
-enablestheengineertocalculateboilerefficiencywhentheboilerisrunningsteadywith
aminimumofinterference
-boilerefficiencyistheheatsuppliedtothesteamperhourdividedbytheheatavailable
fromthefuelperhour
C.THEFLASHPOINT
-enablesengineertojudgeiffuelissafetostorenearabuilding
-thehighertheflashpoint,thesafertheproductwilltendtobetohandleandstore
-normallyfueloilswithaflashpointoflessthan66degreesCwouldnotbestored
-allfueloilsnormallyhaveaflashpointofaround90-95degreesC
-fueloilsaresafertohandlethankeroseneorgasolinewhichhaveamuchlowerflash
point
Flashpoint:thetemperaturewhereaproductgivesoffenoughvaportobeignitedbutnotsustain
aflame
D.CONGEALINGORPOURPOINT
-enablestheengineertoknowatwhattemperaturetheoilwillrefusetoflow
-tracersteamlineswouldneedtobeinstalledonallfuellinesinareasthatexperience
sub-zerotemperatures
-toknowthepourpointwouldindicatewhenthetracersteamlinesshouldbebrought
backintoserviceinthefall
E.VISCOSITY
-isameasureoftheresistancetoflow
-itisexpressedintimeinsecondsthattheoilatacertaintemperaturewilltaketoflow
throughastandardsizedholebygravity
-thehighertheviscositythemoretroubleonecanexpectwhenburningthefuel
-iftheviscosityistoohigh,atomizationispoorandexcessivecarbondepositswillresult
onthefurnacefloorandintheboilerheatingareas
theflamepatternwillbepoorwithincompletecombustionandalowerheatrelease.Operatingcostsasa
resultwillbehigher
3.Asashiftengineerinchargeofalargehighpressure(15000kpa)multiburnergasfired
boilerequippedwithasuperheater,economizer,forceddraftfans,andautomatic
combustioncontrols.Describethepossiblecausesofandtheactionsthatyouwouldtakein
thefollowingcircumstances.Theboilerisonsteadyload.
a.Alowdrumwaterlevelcondition.(8marks)
ANSWER
A.BOILERFEEDWATERLEVELCONTROLVALVE
-cause:isolationvalveclosedoninletoroutlet
-remedy:openvalve
-cause:failed
-remedy:openby-passaroundcontroller
B.BOILERFEEDWATERPUMP
-cause:failed
-remedy:startbackuppump
-cause:isolationvalveclosed
-remedy:openvalve
-cause:cavitation
-remedy:drainandbleedpumptoriditoftheairlock;thenrestartpump
C.INSTRUMENTATION/EQUIPMENTFAILURE
-cause:failureofswitch
-remedy:replaceswitch
-cause:electricalwire
-remedy:checkforlooseconnectionsandtighten
-remedy:ifshortcircuitingduetobarewiresorbrittleinsulation:replace
wire
-cause:mercuryswitchglassiscracked
-remedy:replacemercuryswitch
-cause:sedimentinfloatchamber
-remedy:blowoutthechamberbymeansofdrainvalveprovided
-cause:lowwaterfuelcutoffswitch
-remedy:testregularlytoensureitisworkingproperly.
Immediatelyreplaceifnotworking.Thisisacritical
pieceofequipmentinstrumentation.
b.Aflamefailure.(7marks)”
ANSWER
-cause:fuelsupplypressuredrops
-remedy:shutdownmainburners.Allalarmsmustberesetandall
parametersmetbeforereignitingburners.
-cause:lowwaterfuelcutoffhasactuated
-remedy:findcauseoflowwaterlevelandaddressthatissuebefore
attemptingtore-establishflame
-cause:ifboilerisnormallyrunatslightlynegativepressureanditgoestopositive
pressure一boilerwillshutdown
-remedy:louversoninducedfanshaveopenedtoorapidlycausing
suddenpressurechangefromnegativetopositive.
Operator:resetalarm,thenclosethelouversslightlytore-
establishnegativepressurewithinthefurnace.
-cause:burnermalfunction
-remedy:isolatethatburnerandreplaceitwhentheunitisshutdownfor
maintainancetoallowcontinuedoperation
-cause:tubefailure
-remedy:catastrophictubefailure:waterhasextinguishedflamesatthe
burners.Operator:shutdownentireunitimmediately.Ensure
inducedfansarerunningtopurgethefurnaceofcombustiblegases
orpocketsofgases.Watertubeswillneedtobereplacedandunit
willneedtobeinspectedbyaqualifiedboilerinspectorbeforeunit
isbroughtbackintoservice.
-cause:fireeyesnotfunctioningproperly
-remedy:cleanfireeyesaccordingtoprocedure
4.Awatertubeboilerhasjustbeentakenofflineandisintheprocessofcoolingdown.
Describetheproperprocedureforpreparingtheboilerforinspectionandthesafety
precautionstobetakenduringtheinspection.(10marks)
ANSWER4
1.Reduceloadonboiler.
2.Atabout50%load,operatethesootblowerstocleanthefiresidesurfacesasmuchaspossible.
3.Whenthefiresareout,allowtheboilertocooltoapressureof35-70Kpaandthenopenthe
drumvents.
4.Isolatetheboilerbyclosingthesteamstopvalves;feedwaterstopvalves;fuelvalves;air
dampersonFDfans;steamtosootblowervalves;chemicalfeedvalves;steamtofanorfeed
pumpturbines;atomizingsteamvalves;continuousblowdownvalvesandbyopeningcircuit
breakersoffeedpumpmotors,fanmotors,chemicalfeedpumpmotors,retractablesootblower
motors,rotaryairheaterdrivesoranyvalveorcircuitbreakerwhichmayallowanygas,liquid
orsolidtoentertheboilerorcouldcausemotionofequipmentwithintheboiler.Tagallvalves
withbrightlycolored"DONOTOPERATE,,tagsandrecordallthesesotheycanbeaccounted
forwhentheyareremovedinpreparationforstartinguptheboileragain.Thesetagsarenotto
removedortamperedwithuntilallworkissignedoffandaretoberemovedonlybytheoperator.
5.Whenboilerwaterhascooledtoabout90degreesC,opentheblowdownvalvesanddrainboiler.
6.Ifitwasformaintenance,theboilerwouldnowbeflushedoutwithahighpressurewaterhose.
Theinspectorwillwanttoinspectsludge;scale;buildup;etcsoavoidthisstepuntilapprovalby
theinspectorisreceived.
7.Whentheboilerhasdrained,closeandtagtheblowdownvalve.
8.Openfiresideaccessdoor.
9.Ifextensionlightsaretobeused,atransformermustbeprovidedwhichchangespowerto12Vto
eliminatethedangerofelectrocutiontopersonnelintheboiler.
10.Provideprotectiveclothing,goggles,faceshieldandgloveswherenecessary.
SAFETYPRECAUTIONS:
1.Properpersonalprotectiveequipment:coveralls,glasses/goggles,gloves,steeltoedworkboots,
faceshield,radio,flashlight,personalairmonitor.
2.Trainedpersonnelaretheonlypersonsallowedtoentervessel:CONFINEDSPACE.
3.Preplanningmeetingtoplanallaspectsoftheconfinedspaceentry:allinvolveddepartmentsor
personnelshouldbeinattendanceatallrelatedmeetings.Thisincludestheemergencypersonnel
aswell.
4.Safeworkplansorproceduresmustbeauthorizedpriortoanyentryorworkbeingdone.
5.Meetingjustpriortoentrytogooverallaspectsofentry.
6.Allpermitsareinorderandapproved.
7.Ongoingairqualitytesting.Dependingonvesselmaybeeverysixhoursorcontinual.If
continualallpersonnelenteringvesselmustwearSCBAgear.Itisrecommendedthatall
personnelwearsomekindofpersonalairmonitorsuchasthe“RATTLER“tomonitorany
changesinairquality.
8.SCBAequipmentifnecessary.
9.Qualifiedstand-bypersonattheentryofthevessel.Thispersoncanatnotimeleavethevessel
unattended-mustberelievedbyanotherqualifiedpersonbeforeleavingtheareaforanyreason.
10.Recordofallpersonnelwhoenterthevessel.Sign-insheetaswellasidentificationtagslefton
boardatentrytovessel.
11.Confinedspaceentrytagshungatentrytovessel.
12.Radiocontactbetweenpersonnelenteringvessel,stand-bypersonandemergencypersonnelat
alltimes.
13.Updatingpennitsandairsamplingasnecessary.
14.Iftheentryisleftopenatanytimewithnopersonnelaround,a"DONOTENTER“signshould
behungdirectlyovertheopeningoftheentry.
IfdangerousgassuchasH2Sispresentintheareaorhasthepotentialofbeinginthearea:signsshould
behungindicatingthesame.
5.a.Whatisthepurposeofawatercolumnonaboiler.(3marks)
ANSWER
Actsasareservoirtodampenagitationofthewater.
-makesthelevelinthegageglasseasiertoread
Trapanysludgeorsedimentandpreventitfromcollectingintheglassconnections
Providesaplacefortheinstallationofalarmfloats
Providesvisibleindicationofwaterlevelinboiler.
Allowsoperatortocheckorverifywaterlevelinboilershouldthegageglassbebroken.
-usingtri-cocksattachedtowatercolumn.
b.Describethebestprocedureforverifyingtheproperoperationofawatercolumnandgauge
glassonanoperatingboiler.(6marks)
ANSWER
1.Closethegagesteamvalveandthegagewatervalveinordertoisolatethegagebeforechecking
thecolumnconnections
2.Closecolumnwatervalveandopencolumndrainvalvethusblowingthroughthesteam
connectionandthecolumnandprovingthemclear
3.Closecolumnsteamvalveandopencolumnwatervalvethusblowingthroughthewater
connectionandprovingitclear
4.Closecolumndrainvalveandopencolumnsteamvalveputtingcolumnbackinoperating
condition
5.Opengagedrainvalveandgagesteamvalvethusblowingthroughthesteamconnectionandthe
gageglassandprovingthemclear
6.Closegagesteamvalveandopengagewatervalvethusblowingthroughthewaterconnection
andprovingitclear
7.Opengagesteamvalveandclosegagedrainvalveputtinggagebackinoperatingcondition
NOTE:allconnectionstobothcolumnandgagehavenowbeenblownthroughseparatelytoprove
themclear.
c.Describethecorrectprocedureforreplacingabrokentubulargaugeglassonanoperating
boiler.(6marks)
ANSWER
1.Shutoffthesteamandwatervalvesonthegage
2.Openthegagedrainvalve
3.Removebrokengageglass.Eachendoftheglassisheldinplaceinthegagefittingbymeansof
anutandawasher.Byunscrewingthenuts,thewashersandglassmayberemoved
4.Opengagevalvestoblowoutsmallfragmentsofglassandthencloseagain
5.Cutnewglasstocorrectlengthusingaglasstubecutter
6.Placenutsandnewwashersontheglassandinstallinthegagefittings.Somepowderedgraphite
maybeusedasalubricantbetweenwashersandnuts.Nutsshouldbehandtightenedonly
7.Heatuptheglassslowlybycrackingopengagesteamvalve.Thenclosegagedrainvalveand
crackopengagewatervalve.Whenwaterlevelinglassstabilizes,openthegagesteamandwater
valvesfully
NOTE:operatorsshouldwearproperPPEtoprotecteyes,face,handsetcincasenewglassburstswhen
putintoservice.Useextremecautionwhenpressurizingthegageglass
6.Describetheprincipleofoperationandthemethodoftestingofeachofthefollowingsafety
devicesfoundonapackagedboiler.
a.Highlimitpressurecontrol.(5marks)
ANSWER
HighLimitControl(HighSteamPressureFuelCut-Off)
TheBoilerCoderequiresthatautomaticallyfiredsteamheatingboilersnotunderconstantsupervision
mustbeequippedwithahighlimitpressurecontrolthatshutsoffthefuelsupplyataboilerpressurenot
toexceed103kPa(15psi).
Thiscontrolmustbeconnectedtotheboilerwithoutanyshut-offvalvesanditshallbeprotectedbya
syphonorasimilarmeansofmaintainingawatersealtopreventsteamfromenteringthecontrol.
Thepurposeofthehighlimitcontrolistoshutoffthefiringequipmentshouldtheoperatinglimit
pressurecontrolfailtoshutofftheburnerwhenitreachesitscut-outpointandpressurecontinuestorise.
Thehighlimitcontrolthusactsasasafeguardtopreventexcessiveboilerpressureandwillpreventthe
pressurefromrisingtothepointatwhichthesafetyvalveswouldopenupandreleasethesteamto
atmosphere.
Indesignandoperationthehighlimitcontrolisquitesimilartotheon-offpressurecontrolbutitisnot
equippedwithadifferentialspringsothatthecut-outandcut-inpointsofthecontrolareveryclose
together.Also,thecontrolafterhavingshutofftheburneronreachingitscut-outpoint,locksoutand
doesnotautomaticallystarttheburnerupagainwhenthepressuredrops.Instead,ithastobemanually
resetbyaresetleverorbuttonontheoutsideofthecontrolbeforetheboilercanbestartedagain.The
reasonforthisarrangementistoindicatetotheboileroperatorthattheoperatingcontrolis
malfunctioning.Theoperatingcontrolmustberepairedorreplacedimmediately.
Itisgenerallyrecommendedtosetthecut-outpressureofthehighlimitcontrolsufficientlyabovethe
cut-outpressureoftheoperatinglimitcontroltoavoidunnecessarylock-outsshouldtheoperating
controlbeslightlyoutofcalibration.Ideallythecut-outpressureofthehighlimitcontrolshouldnot
exceedninetypercentofthesafetyvalvesetting.
4thcllOPressureControl
TEST
Thepressureandtemperaturehighlimitcontrolscannotbetested
duringnormalboileroperationsincetheyonlyoperateabovethe
cut-outpointoftheoperatingcontrol.Totestthehighlimitcontrol,
disconnectthepowertotheboilercontrolsandplaceatestlead
acrosstheterminalsoftheoperatingcontrol.Checkthesettingofthe
highlimitcontrol.Restorepowertothecontrolsandstarttheboiler.
Allowtheboilertofireuntilthesteampressureorwatertemperature
reachesthesettingofthehighlimitcontrol.Thecontrolshould
operateatthispointandshutdownthefiringequipment.Ifthetestis
O.K.,disconnectthepowerandremovethetestlead.Resetthehigh
limitcontrolandputtheboilerbackintooperation.
Thehighlimitcontrolofalow-pressuresteamheatingboilershouldopenatapressurehigherthanthe
cut-outpressureoftheoperatingcontrol,butlowerthan103kPa(15psi),thepoppingpressureofthe
safetyvalve.Onlow-pressurehotwaterboilersthecut-outtemperatureofthehighlimitcontrolshould
besetabovethecut-outsettingoftheoperatingcontrolbutneverhigherthat121℃(250°F),the
maximumallowablewatertemperaturefortheboiler.
Generally,themaintenanceonoperatingandlimitingcontrolsonlyrequiresvisualinspectionofthe
deviceforevidenceofwear,corrosion,etc.Iftheswitchisamercurybulbtype,itshouldalsobe
checked.
LowAirPressureFuelCut-OffSwitch
Thisdeviceisusedtopreventburneroperationwhentheamountofcombustionairsuppliedtothe
furnaceisinsufficienttoprovidesafecombustionofthefuel.Abasicsketchofthisdeviceisshownin
Fig.6.Thedeviceconsistsofasealedhousingdividedintwobyaflexiblediaphragmwhichis
connectedtoaswitchcontrollingthepowersupplytothefuelvalve.One
sideofthehousingisopentoatmosphere,theothersideisconnectedto
thedischargesideoftheforceddraftfan.Whenthefanisnotinoperation
orwhenitdevelopsinsufficientairpressure,thespringactingonthe
diaphragmwillkeeptheswitchopenandpowersupplytothefuelvalveis
notpossible.
Whenthefanisstartedandcomesuptospeed,sufficientairshouldbe
forcedintothefurnacetobuildupenoughpressurefortheairenteringthe
controltomovethediaphragmagainsttheforceofthespringandtoclose
theswitch.Thiswillallowthefuelvalvetobeenergizedandtheburnerto
belit.Ifduringoperationtheamountofcombustionairsuppliedwould
dropoffbelowthesafeminimumrequiredduetoamalfunctionofthefan,
thepressureoftheairwilldropaswell.Thecut-offswitchwillopen,de-
energizingthefuelvalve,andtheburnerwillceasefiring.
TESTThetestingofthelowairpressurecut-offismorecomplicated.Itisnecessarytotakemanual
controloftheprogrammer,ifpossible.Atestlightwithpowersourceshouldbeattachedtotheterminals
ofthecontrol.Withthefaninoperationandthe
burnerdamperinwideopenpositionformaximum
airflowandminimumpressure,thecontactsofthe
cut-offshouldbeclosedandthelightburning.By
restrictingtheairintaketothefan,thecut-offpoint
ofthecontrolcanbefound.
LowGasPressureFuelCut-OffSwitch
Thissafetycontroldeviceworksonthesame
principleasthelowairpressurecut-off.If,forany
reason,thepressureofthegassuppliedtotheburner
dropsbelowaminimumvalue,whichindicates
insufficientgasfbrsafecombustion,theswitchopens
up,andthefuelsupplyiscutoff.TheswitchinFig.
7consistsofadiaphragmorbellowswithpressurefromthefuelactingonitslowersideandthe
opposingforceofthespringactingonitsupperside.Ifthepressureofthefueldropsbelowasafelevel,
theleafspringwilldrop,openingtheswitchtothesolenoidoperatingthegasvalve.Thevalvethen
closes,shuttingdowntheburner,preventinganexplosiveconditionintheboilerduetoanunstable
flame.
TESTThelowgaspressurecut-offcanbetestedduringtheoperationoftheboilerbyslowlyclosing
themaingascock.Observethepressuregageonthegasline.Whenthepressureinthelinedropstothe
cut-offpoint,theburnervalveshouldshutautomatically
PRINCIPLE:cutsofffuelsupplywhenthepressureisatorabovethesetpressure.Iftheoperating
rangewasbetween5.5and8andthepressureofthefuelwasrising:analarmwouldbesentwhengas
pressurereached8.25.Ifthepressurecontinuedtorise,thefuelwouldbeshutoffwhenpressurereached
8.75.Allthesemeasurementsareinpsig.
TEST:
b.Lowgaspressurecutoff.(5marks)
PRINCIPLE:apressureoperatedswitchwhichpreventstheburnerfromoperatingwhenthegas
pressureinthesupplylinedropsbelowthepressurenecessarytomaintainastableflameattheburner.
Worksthesameasthehighpressurecontrolbutsendsfirstanalarmandthenshutsfueloffaspressure
isdropping.Aswiththeabovenumbers:analarmwouldbesentwhenpressuredropsto5.25andfuelis
shutoffat5.0.Again,themeasurementsareinpsig.
TEST:
c.Lowairpressurecutoff.(5marks)
ANSWER
PRINCIPLE:-worksinsameprincipleasthelowgaspressurefuelcutoff.Iftheamountofair
suppliedtotheburnerdropsbelowtheminimumrequiredforsafecombustion,thesupplypressurein
theducttotheburnerdropsoffaccordingly,thentheswitchopensupandthefuelsupplyiscutoff.
TEST:
7.Listthenecessarycontrolsforanautomaticallycontrolledlowpressuresteamheating
boileranddescribethepurposeandmethodofoperationofeachcontrol.(10marks)
ANSWER:4thclassc74
SAFETYDEVICESANDINTERLOCKS
Interlocksmaybedefinedasanumberofelectricalswitchesconnectedinseries,whosepurposeisto
protectapieceofequipment,orsystem,frombeingoperatedinanunsafecondition.Ifallconditionsor
measurementsrelevanttosafeoperationoftheequipment,suchasaboiler,aresatisfied,itwillkeep
operating.Ifoneormoreunsafeconditions,suchaslowdrumlevel,etc.,shouldoccur,therespective
relayorelectricalswitchwillopen,andtheprocessorequipmentwillshutdown.Someoftheelectrical
relaysorautomaticallyoperatedswitchesusedonboilersaredescribedbelow.Ineachcase,theswitchis
locatedintheelectricalcircuitsupplyingpowertoanelectricallyoperatedvalveinthemain(orpilot)
fuelgasline.Ifanyoftheseswitchesopensthevalvewillclose,thusputtingtheboilerintoasafe,non-
operatingcondition.
LowAirPressureFuelCutoffSwitch
Thelowairpressureswitchisasafetydevicemountedonboilerswithforceddraftfansorblowers.Itis
usedtoshutdowntheboilerfuelsupplywhenthesupplyofcombustionairisinsufficienttoprovidea
stableflame.Fig.1isabasicillustrationofthedevice.
Theswitchconsistsofasealedhousingdividedintotwosectionsbyadiaphragmwhichisconnectedto
aswitchcontrollingthepowersupplytothefuelvalve.Onesideofthehousing,containingthespring,is
opentotheatmosphere.Theothersideisconnectedtothedischargeoftheforceddraftfan.Ifthefanis
notinoperation,orwhenitdevelopsinsufficientdischargepressure,thespringactingontheleftsideof
thediaphragmwillkeeptheswitchopentothefuelvalvepowersupply.
Whenthefanisstarted,andtheforceduetotheairpressureexceedsthespringforce,thediaphragm
willmovetotheleftandclosetheswitch.Thiswillpermitthefuelvalvetobeenergizedandtheburner
tobelitiftheotherinterlocksareclosed.Shouldtheairsupplydropbelowasafeminimumdueto
malfunctionofafanduringboileroperation,thepressureoftheairwilldropandthespringwillopen
theelectricalcircuittothefuelvalvecausingtheburnertobeshutdown.
LowGasPressureFuelCutoffSwitch
Thissafetycontroldeviceoperatesonthesameprincipleasthelowairpressurefuelcutoffswitch.Ifthe
fuelgaspressuredropsbelowthevaluerequiredtomaintainastableflame,theswitchwillopenthe
electricalcircuittothefuelgasvalve.Asimilarlowoilpressureswitchcanbeusedonoil-firedboilers.
FlameFailureDetector
If,foranyreason,theburnerflameshouldgooutduringtheoperationofanoil-orgas-firedboiler,itis
necessarytoshutoffthefuelvalveimmediately.Thiswillpreventunbumedfuelfromcollectinginthe
furnaceandcausinganexplosion.Aflamefailuredetectorservesthepurpose.
Onetypeofflamefailuredevice,illustratedinFig.2usesaleadsulphidecellwhichissensitivetothe
infraredraysradiatingfromtheflame.Itsresistancetocurrentflowdecreasesastheintensityofinfrared
radiationincreases.Iftheflameshouldgooutthenthecellwillnolongersensetheradiationcausingits
resistancetocurrentflowtoincreaseandthefuelvalvetoclose.Theleadsulphidecell,commonly
calleda"scanner”mustbemountedonthefurnacefrontinsuchawaythatithasaclearviewofthe
flamethrougharestrictedorifice.Thetubeorrestrictionwillreducetheeffectsofradiationfromthehot
refractorytowhichthisdetectorisalsosensitive.
Theultravioletsensororscannerissensitivetoultravioletradiationfromtheflame'sprimary
combustionzone.Iftheflamegoesoutthepowersupplytothefuelvalvewillbeopenedandthevalve
willclose.
Mostpackagedboilersuseascanner
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- JJF 2184-2025電子計價秤型式評價大綱(試行)
- 校園各項消防安全管理工作計劃三篇
- 【可行性報告】2025年防毒面具項目可行性研究分析報告
- 照明工業(yè)刻錄機行業(yè)行業(yè)發(fā)展趨勢及投資戰(zhàn)略研究分析報告
- 音樂一年級下冊教學計劃
- 開學典禮演講稿范文15篇
- 志愿者2022工作計劃安排三篇
- 語文教研組工作計劃
- 中航重機驗資報告
- 工作保證書集合15篇
- 軍工合作合同范例
- 2025年中國稀土集團總部部分崗位社會公開招聘管理單位筆試遴選500模擬題附帶答案詳解
- 超市柜臺長期出租合同范例
- 廣東省廣州市2025屆高三上學期12月調(diào)研測試語文試題(含答案)
- 【8物(科)期末】合肥市第四十五中學2023-2024學年八年級上學期期末物理試題
- 統(tǒng)編版2024-2025學年三年級語文上冊期末學業(yè)質(zhì)量監(jiān)測試卷(含答案)
- 從0 開始運營抖?音號sop 文檔
- 2024-2025學年深圳市初三適應性考試模擬試卷歷史試卷
- 16J914-1 公用建筑衛(wèi)生間
- 贊比亞礦產(chǎn)資源及礦業(yè)開發(fā)前景分析
- 大型儲罐吊裝方案
評論
0/150
提交評論