1.Consideralargemodern(15000-kpa)steamgeneratorfiringpulverizedcoal.Explainin

detailhowthehotgasesgiveuptheirheatinpassingfromthefireballinthefurnacetothe

stackexit.Indicateinyourexplanation,thevariouspartsoftheunitcontactedbythegases

intheircorrectsequence.(15marks)

ANSWER:

2.List5characteristicsoffueloilthatmustbeconsideredwhenselectingapowerplantfuel.

Explainhowtheseimpactontheoperationoftheplant.(15marks)

ANSWER

A.THESPECIFICGRAVITY

-enablestheengineertodetermineiftheoilislightorheavy

-generallythehigherthespecificgravity,thelowerthehydrogencontentandtheharderit

istoignitethefuel

-lightfueloilavoidsthecostofkeepinganoiltankwarmed

-heavyfueloilsarethecheapesttopurchasebutitbecomescriticaltoknowthewater

contentoftheheavyfueloil.Someheavyfueloilsrequiretobeheatedtoashighas135

degreesCattheburnersupplybeforetheywillbumcompletely

B.THEHEATINGVALUE

-isrequiredtobeknown

-enablestheengineertocalculateboilerefficiencywhentheboilerisrunningsteadywith

aminimumofinterference

-boilerefficiencyistheheatsuppliedtothesteamperhourdividedbytheheatavailable

fromthefuelperhour

C.THEFLASHPOINT

-enablesengineertojudgeiffuelissafetostorenearabuilding

-thehighertheflashpoint,thesafertheproductwilltendtobetohandleandstore

-normallyfueloilswithaflashpointoflessthan66degreesCwouldnotbestored

-allfueloilsnormallyhaveaflashpointofaround90-95degreesC

-fueloilsaresafertohandlethankeroseneorgasolinewhichhaveamuchlowerflash

point

Flashpoint:thetemperaturewhereaproductgivesoffenoughvaportobeignitedbutnotsustain

aflame

D.CONGEALINGORPOURPOINT

-enablestheengineertoknowatwhattemperaturetheoilwillrefusetoflow

-tracersteamlineswouldneedtobeinstalledonallfuellinesinareasthatexperience

sub-zerotemperatures

-toknowthepourpointwouldindicatewhenthetracersteamlinesshouldbebrought

backintoserviceinthefall

E.VISCOSITY

-isameasureoftheresistancetoflow

-itisexpressedintimeinsecondsthattheoilatacertaintemperaturewilltaketoflow

throughastandardsizedholebygravity

-thehighertheviscositythemoretroubleonecanexpectwhenburningthefuel

-iftheviscosityistoohigh,atomizationispoorandexcessivecarbondepositswillresult

onthefurnacefloorandintheboilerheatingareas

theflamepatternwillbepoorwithincompletecombustionandalowerheatrelease.Operatingcostsasa

resultwillbehigher

3.Asashiftengineerinchargeofalargehighpressure(15000kpa)multiburnergasfired

boilerequippedwithasuperheater,economizer,forceddraftfans,andautomatic

combustioncontrols.Describethepossiblecausesofandtheactionsthatyouwouldtakein

thefollowingcircumstances.Theboilerisonsteadyload.

a.Alowdrumwaterlevelcondition.(8marks)

ANSWER

A.BOILERFEEDWATERLEVELCONTROLVALVE

-cause:isolationvalveclosedoninletoroutlet

-remedy:openvalve

-cause:failed

-remedy:openby-passaroundcontroller

B.BOILERFEEDWATERPUMP

-cause:failed

-remedy:startbackuppump

-cause:isolationvalveclosed

-remedy:openvalve

-cause:cavitation

-remedy:drainandbleedpumptoriditoftheairlock;thenrestartpump

C.INSTRUMENTATION/EQUIPMENTFAILURE

-cause:failureofswitch

-remedy:replaceswitch

-cause:electricalwire

-remedy:checkforlooseconnectionsandtighten

-remedy:ifshortcircuitingduetobarewiresorbrittleinsulation:replace

wire

-cause:mercuryswitchglassiscracked

-remedy:replacemercuryswitch

-cause:sedimentinfloatchamber

-remedy:blowoutthechamberbymeansofdrainvalveprovided

-cause:lowwaterfuelcutoffswitch

-remedy:testregularlytoensureitisworkingproperly.

Immediatelyreplaceifnotworking.Thisisacritical

pieceofequipmentinstrumentation.

b.Aflamefailure.(7marks)”

ANSWER

-cause:fuelsupplypressuredrops

-remedy:shutdownmainburners.Allalarmsmustberesetandall

parametersmetbeforereignitingburners.

-cause:lowwaterfuelcutoffhasactuated

-remedy:findcauseoflowwaterlevelandaddressthatissuebefore

attemptingtore-establishflame

-cause:ifboilerisnormallyrunatslightlynegativepressureanditgoestopositive

pressure一boilerwillshutdown

-remedy:louversoninducedfanshaveopenedtoorapidlycausing

suddenpressurechangefromnegativetopositive.

Operator:resetalarm,thenclosethelouversslightlytore-

establishnegativepressurewithinthefurnace.

-cause:burnermalfunction

-remedy:isolatethatburnerandreplaceitwhentheunitisshutdownfor

maintainancetoallowcontinuedoperation

-cause:tubefailure

-remedy:catastrophictubefailure:waterhasextinguishedflamesatthe

burners.Operator:shutdownentireunitimmediately.Ensure

inducedfansarerunningtopurgethefurnaceofcombustiblegases

orpocketsofgases.Watertubeswillneedtobereplacedandunit

willneedtobeinspectedbyaqualifiedboilerinspectorbeforeunit

isbroughtbackintoservice.

-cause:fireeyesnotfunctioningproperly

-remedy:cleanfireeyesaccordingtoprocedure

4.Awatertubeboilerhasjustbeentakenofflineandisintheprocessofcoolingdown.

Describetheproperprocedureforpreparingtheboilerforinspectionandthesafety

precautionstobetakenduringtheinspection.(10marks)

ANSWER4

1.Reduceloadonboiler.

2.Atabout50%load,operatethesootblowerstocleanthefiresidesurfacesasmuchaspossible.

3.Whenthefiresareout,allowtheboilertocooltoapressureof35-70Kpaandthenopenthe

drumvents.

4.Isolatetheboilerbyclosingthesteamstopvalves;feedwaterstopvalves;fuelvalves;air

dampersonFDfans;steamtosootblowervalves;chemicalfeedvalves;steamtofanorfeed

pumpturbines;atomizingsteamvalves;continuousblowdownvalvesandbyopeningcircuit

breakersoffeedpumpmotors,fanmotors,chemicalfeedpumpmotors,retractablesootblower

motors,rotaryairheaterdrivesoranyvalveorcircuitbreakerwhichmayallowanygas,liquid

orsolidtoentertheboilerorcouldcausemotionofequipmentwithintheboiler.Tagallvalves

withbrightlycolored"DONOTOPERATE,,tagsandrecordallthesesotheycanbeaccounted

forwhentheyareremovedinpreparationforstartinguptheboileragain.Thesetagsarenotto

removedortamperedwithuntilallworkissignedoffandaretoberemovedonlybytheoperator.

5.Whenboilerwaterhascooledtoabout90degreesC,opentheblowdownvalvesanddrainboiler.

6.Ifitwasformaintenance,theboilerwouldnowbeflushedoutwithahighpressurewaterhose.

Theinspectorwillwanttoinspectsludge;scale;buildup;etcsoavoidthisstepuntilapprovalby

theinspectorisreceived.

7.Whentheboilerhasdrained,closeandtagtheblowdownvalve.

8.Openfiresideaccessdoor.

9.Ifextensionlightsaretobeused,atransformermustbeprovidedwhichchangespowerto12Vto

eliminatethedangerofelectrocutiontopersonnelintheboiler.

10.Provideprotectiveclothing,goggles,faceshieldandgloveswherenecessary.

SAFETYPRECAUTIONS:

1.Properpersonalprotectiveequipment:coveralls,glasses/goggles,gloves,steeltoedworkboots,

faceshield,radio,flashlight,personalairmonitor.

2.Trainedpersonnelaretheonlypersonsallowedtoentervessel:CONFINEDSPACE.

3.Preplanningmeetingtoplanallaspectsoftheconfinedspaceentry:allinvolveddepartmentsor

personnelshouldbeinattendanceatallrelatedmeetings.Thisincludestheemergencypersonnel

aswell.

4.Safeworkplansorproceduresmustbeauthorizedpriortoanyentryorworkbeingdone.

5.Meetingjustpriortoentrytogooverallaspectsofentry.

6.Allpermitsareinorderandapproved.

7.Ongoingairqualitytesting.Dependingonvesselmaybeeverysixhoursorcontinual.If

continualallpersonnelenteringvesselmustwearSCBAgear.Itisrecommendedthatall

personnelwearsomekindofpersonalairmonitorsuchasthe“RATTLER“tomonitorany

changesinairquality.

8.SCBAequipmentifnecessary.

9.Qualifiedstand-bypersonattheentryofthevessel.Thispersoncanatnotimeleavethevessel

unattended-mustberelievedbyanotherqualifiedpersonbeforeleavingtheareaforanyreason.

10.Recordofallpersonnelwhoenterthevessel.Sign-insheetaswellasidentificationtagslefton

boardatentrytovessel.

11.Confinedspaceentrytagshungatentrytovessel.

12.Radiocontactbetweenpersonnelenteringvessel,stand-bypersonandemergencypersonnelat

alltimes.

13.Updatingpennitsandairsamplingasnecessary.

14.Iftheentryisleftopenatanytimewithnopersonnelaround,a"DONOTENTER“signshould

behungdirectlyovertheopeningoftheentry.

IfdangerousgassuchasH2Sispresentintheareaorhasthepotentialofbeinginthearea:signsshould

behungindicatingthesame.

5.a.Whatisthepurposeofawatercolumnonaboiler.(3marks)

ANSWER

Actsasareservoirtodampenagitationofthewater.

-makesthelevelinthegageglasseasiertoread

Trapanysludgeorsedimentandpreventitfromcollectingintheglassconnections

Providesaplacefortheinstallationofalarmfloats

Providesvisibleindicationofwaterlevelinboiler.

Allowsoperatortocheckorverifywaterlevelinboilershouldthegageglassbebroken.

-usingtri-cocksattachedtowatercolumn.

b.Describethebestprocedureforverifyingtheproperoperationofawatercolumnandgauge

glassonanoperatingboiler.(6marks)

ANSWER

1.Closethegagesteamvalveandthegagewatervalveinordertoisolatethegagebeforechecking

thecolumnconnections

2.Closecolumnwatervalveandopencolumndrainvalvethusblowingthroughthesteam

connectionandthecolumnandprovingthemclear

3.Closecolumnsteamvalveandopencolumnwatervalvethusblowingthroughthewater

connectionandprovingitclear

4.Closecolumndrainvalveandopencolumnsteamvalveputtingcolumnbackinoperating

condition

5.Opengagedrainvalveandgagesteamvalvethusblowingthroughthesteamconnectionandthe

gageglassandprovingthemclear

6.Closegagesteamvalveandopengagewatervalvethusblowingthroughthewaterconnection

andprovingitclear

7.Opengagesteamvalveandclosegagedrainvalveputtinggagebackinoperatingcondition

NOTE:allconnectionstobothcolumnandgagehavenowbeenblownthroughseparatelytoprove

themclear.

c.Describethecorrectprocedureforreplacingabrokentubulargaugeglassonanoperating

boiler.(6marks)

ANSWER

1.Shutoffthesteamandwatervalvesonthegage

2.Openthegagedrainvalve

3.Removebrokengageglass.Eachendoftheglassisheldinplaceinthegagefittingbymeansof

anutandawasher.Byunscrewingthenuts,thewashersandglassmayberemoved

4.Opengagevalvestoblowoutsmallfragmentsofglassandthencloseagain

5.Cutnewglasstocorrectlengthusingaglasstubecutter

6.Placenutsandnewwashersontheglassandinstallinthegagefittings.Somepowderedgraphite

maybeusedasalubricantbetweenwashersandnuts.Nutsshouldbehandtightenedonly

7.Heatuptheglassslowlybycrackingopengagesteamvalve.Thenclosegagedrainvalveand

crackopengagewatervalve.Whenwaterlevelinglassstabilizes,openthegagesteamandwater

valvesfully

NOTE:operatorsshouldwearproperPPEtoprotecteyes,face,handsetcincasenewglassburstswhen

putintoservice.Useextremecautionwhenpressurizingthegageglass

6.Describetheprincipleofoperationandthemethodoftestingofeachofthefollowingsafety

devicesfoundonapackagedboiler.

a.Highlimitpressurecontrol.(5marks)

ANSWER

HighLimitControl(HighSteamPressureFuelCut-Off)

TheBoilerCoderequiresthatautomaticallyfiredsteamheatingboilersnotunderconstantsupervision

mustbeequippedwithahighlimitpressurecontrolthatshutsoffthefuelsupplyataboilerpressurenot

toexceed103kPa(15psi).

Thiscontrolmustbeconnectedtotheboilerwithoutanyshut-offvalvesanditshallbeprotectedbya

syphonorasimilarmeansofmaintainingawatersealtopreventsteamfromenteringthecontrol.

Thepurposeofthehighlimitcontrolistoshutoffthefiringequipmentshouldtheoperatinglimit

pressurecontrolfailtoshutofftheburnerwhenitreachesitscut-outpointandpressurecontinuestorise.

Thehighlimitcontrolthusactsasasafeguardtopreventexcessiveboilerpressureandwillpreventthe

pressurefromrisingtothepointatwhichthesafetyvalveswouldopenupandreleasethesteamto

atmosphere.

Indesignandoperationthehighlimitcontrolisquitesimilartotheon-offpressurecontrolbutitisnot

equippedwithadifferentialspringsothatthecut-outandcut-inpointsofthecontrolareveryclose

together.Also,thecontrolafterhavingshutofftheburneronreachingitscut-outpoint,locksoutand

doesnotautomaticallystarttheburnerupagainwhenthepressuredrops.Instead,ithastobemanually

resetbyaresetleverorbuttonontheoutsideofthecontrolbeforetheboilercanbestartedagain.The

reasonforthisarrangementistoindicatetotheboileroperatorthattheoperatingcontrolis

malfunctioning.Theoperatingcontrolmustberepairedorreplacedimmediately.

Itisgenerallyrecommendedtosetthecut-outpressureofthehighlimitcontrolsufficientlyabovethe

cut-outpressureoftheoperatinglimitcontroltoavoidunnecessarylock-outsshouldtheoperating

controlbeslightlyoutofcalibration.Ideallythecut-outpressureofthehighlimitcontrolshouldnot

exceedninetypercentofthesafetyvalvesetting.

4thcllOPressureControl

TEST

Thepressureandtemperaturehighlimitcontrolscannotbetested

duringnormalboileroperationsincetheyonlyoperateabovethe

cut-outpointoftheoperatingcontrol.Totestthehighlimitcontrol,

disconnectthepowertotheboilercontrolsandplaceatestlead

acrosstheterminalsoftheoperatingcontrol.Checkthesettingofthe

highlimitcontrol.Restorepowertothecontrolsandstarttheboiler.

Allowtheboilertofireuntilthesteampressureorwatertemperature

reachesthesettingofthehighlimitcontrol.Thecontrolshould

operateatthispointandshutdownthefiringequipment.Ifthetestis

O.K.,disconnectthepowerandremovethetestlead.Resetthehigh

limitcontrolandputtheboilerbackintooperation.

Thehighlimitcontrolofalow-pressuresteamheatingboilershouldopenatapressurehigherthanthe

cut-outpressureoftheoperatingcontrol,butlowerthan103kPa(15psi),thepoppingpressureofthe

safetyvalve.Onlow-pressurehotwaterboilersthecut-outtemperatureofthehighlimitcontrolshould

besetabovethecut-outsettingoftheoperatingcontrolbutneverhigherthat121℃(250°F),the

maximumallowablewatertemperaturefortheboiler.

Generally,themaintenanceonoperatingandlimitingcontrolsonlyrequiresvisualinspectionofthe

deviceforevidenceofwear,corrosion,etc.Iftheswitchisamercurybulbtype,itshouldalsobe

checked.

LowAirPressureFuelCut-OffSwitch

Thisdeviceisusedtopreventburneroperationwhentheamountofcombustionairsuppliedtothe

furnaceisinsufficienttoprovidesafecombustionofthefuel.Abasicsketchofthisdeviceisshownin

Fig.6.Thedeviceconsistsofasealedhousingdividedintwobyaflexiblediaphragmwhichis

connectedtoaswitchcontrollingthepowersupplytothefuelvalve.One

sideofthehousingisopentoatmosphere,theothersideisconnectedto

thedischargesideoftheforceddraftfan.Whenthefanisnotinoperation

orwhenitdevelopsinsufficientairpressure,thespringactingonthe

diaphragmwillkeeptheswitchopenandpowersupplytothefuelvalveis

notpossible.

Whenthefanisstartedandcomesuptospeed,sufficientairshouldbe

forcedintothefurnacetobuildupenoughpressurefortheairenteringthe

controltomovethediaphragmagainsttheforceofthespringandtoclose

theswitch.Thiswillallowthefuelvalvetobeenergizedandtheburnerto

belit.Ifduringoperationtheamountofcombustionairsuppliedwould

dropoffbelowthesafeminimumrequiredduetoamalfunctionofthefan,

thepressureoftheairwilldropaswell.Thecut-offswitchwillopen,de-

energizingthefuelvalve,andtheburnerwillceasefiring.

TESTThetestingofthelowairpressurecut-offismorecomplicated.Itisnecessarytotakemanual

controloftheprogrammer,ifpossible.Atestlightwithpowersourceshouldbeattachedtotheterminals

ofthecontrol.Withthefaninoperationandthe

burnerdamperinwideopenpositionformaximum

airflowandminimumpressure,thecontactsofthe

cut-offshouldbeclosedandthelightburning.By

restrictingtheairintaketothefan,thecut-offpoint

ofthecontrolcanbefound.

LowGasPressureFuelCut-OffSwitch

Thissafetycontroldeviceworksonthesame

principleasthelowairpressurecut-off.If,forany

reason,thepressureofthegassuppliedtotheburner

dropsbelowaminimumvalue,whichindicates

insufficientgasfbrsafecombustion,theswitchopens

up,andthefuelsupplyiscutoff.TheswitchinFig.

7consistsofadiaphragmorbellowswithpressurefromthefuelactingonitslowersideandthe

opposingforceofthespringactingonitsupperside.Ifthepressureofthefueldropsbelowasafelevel,

theleafspringwilldrop,openingtheswitchtothesolenoidoperatingthegasvalve.Thevalvethen

closes,shuttingdowntheburner,preventinganexplosiveconditionintheboilerduetoanunstable

flame.

TESTThelowgaspressurecut-offcanbetestedduringtheoperationoftheboilerbyslowlyclosing

themaingascock.Observethepressuregageonthegasline.Whenthepressureinthelinedropstothe

cut-offpoint,theburnervalveshouldshutautomatically

PRINCIPLE:cutsofffuelsupplywhenthepressureisatorabovethesetpressure.Iftheoperating

rangewasbetween5.5and8andthepressureofthefuelwasrising:analarmwouldbesentwhengas

pressurereached8.25.Ifthepressurecontinuedtorise,thefuelwouldbeshutoffwhenpressurereached

8.75.Allthesemeasurementsareinpsig.

TEST:

b.Lowgaspressurecutoff.(5marks)

PRINCIPLE:apressureoperatedswitchwhichpreventstheburnerfromoperatingwhenthegas

pressureinthesupplylinedropsbelowthepressurenecessarytomaintainastableflameattheburner.

Worksthesameasthehighpressurecontrolbutsendsfirstanalarmandthenshutsfueloffaspressure

isdropping.Aswiththeabovenumbers:analarmwouldbesentwhenpressuredropsto5.25andfuelis

shutoffat5.0.Again,themeasurementsareinpsig.

TEST:

c.Lowairpressurecutoff.(5marks)

ANSWER

PRINCIPLE:-worksinsameprincipleasthelowgaspressurefuelcutoff.Iftheamountofair

suppliedtotheburnerdropsbelowtheminimumrequiredforsafecombustion,thesupplypressurein

theducttotheburnerdropsoffaccordingly,thentheswitchopensupandthefuelsupplyiscutoff.

TEST:

7.Listthenecessarycontrolsforanautomaticallycontrolledlowpressuresteamheating

boileranddescribethepurposeandmethodofoperationofeachcontrol.(10marks)

ANSWER:4thclassc74

SAFETYDEVICESANDINTERLOCKS

Interlocksmaybedefinedasanumberofelectricalswitchesconnectedinseries,whosepurposeisto

protectapieceofequipment,orsystem,frombeingoperatedinanunsafecondition.Ifallconditionsor

measurementsrelevanttosafeoperationoftheequipment,suchasaboiler,aresatisfied,itwillkeep

operating.Ifoneormoreunsafeconditions,suchaslowdrumlevel,etc.,shouldoccur,therespective

relayorelectricalswitchwillopen,andtheprocessorequipmentwillshutdown.Someoftheelectrical

relaysorautomaticallyoperatedswitchesusedonboilersaredescribedbelow.Ineachcase,theswitchis

locatedintheelectricalcircuitsupplyingpowertoanelectricallyoperatedvalveinthemain(orpilot)

fuelgasline.Ifanyoftheseswitchesopensthevalvewillclose,thusputtingtheboilerintoasafe,non-

operatingcondition.

LowAirPressureFuelCutoffSwitch

Thelowairpressureswitchisasafetydevicemountedonboilerswithforceddraftfansorblowers.Itis

usedtoshutdowntheboilerfuelsupplywhenthesupplyofcombustionairisinsufficienttoprovidea

stableflame.Fig.1isabasicillustrationofthedevice.

Theswitchconsistsofasealedhousingdividedintotwosectionsbyadiaphragmwhichisconnectedto

aswitchcontrollingthepowersupplytothefuelvalve.Onesideofthehousing,containingthespring,is

opentotheatmosphere.Theothersideisconnectedtothedischargeoftheforceddraftfan.Ifthefanis

notinoperation,orwhenitdevelopsinsufficientdischargepressure,thespringactingontheleftsideof

thediaphragmwillkeeptheswitchopentothefuelvalvepowersupply.

Whenthefanisstarted,andtheforceduetotheairpressureexceedsthespringforce,thediaphragm

willmovetotheleftandclosetheswitch.Thiswillpermitthefuelvalvetobeenergizedandtheburner

tobelitiftheotherinterlocksareclosed.Shouldtheairsupplydropbelowasafeminimumdueto

malfunctionofafanduringboileroperation,thepressureoftheairwilldropandthespringwillopen

theelectricalcircuittothefuelvalvecausingtheburnertobeshutdown.

LowGasPressureFuelCutoffSwitch

Thissafetycontroldeviceoperatesonthesameprincipleasthelowairpressurefuelcutoffswitch.Ifthe

fuelgaspressuredropsbelowthevaluerequiredtomaintainastableflame,theswitchwillopenthe

electricalcircuittothefuelgasvalve.Asimilarlowoilpressureswitchcanbeusedonoil-firedboilers.

FlameFailureDetector

If,foranyreason,theburnerflameshouldgooutduringtheoperationofanoil-orgas-firedboiler,itis

necessarytoshutoffthefuelvalveimmediately.Thiswillpreventunbumedfuelfromcollectinginthe

furnaceandcausinganexplosion.Aflamefailuredetectorservesthepurpose.

Onetypeofflamefailuredevice,illustratedinFig.2usesaleadsulphidecellwhichissensitivetothe

infraredraysradiatingfromtheflame.Itsresistancetocurrentflowdecreasesastheintensityofinfrared

radiationincreases.Iftheflameshouldgooutthenthecellwillnolongersensetheradiationcausingits

resistancetocurrentflowtoincreaseandthefuelvalvetoclose.Theleadsulphidecell,commonly

calleda"scanner”mustbemountedonthefurnacefrontinsuchawaythatithasaclearviewofthe

flamethrougharestrictedorifice.Thetubeorrestrictionwillreducetheeffectsofradiationfromthehot

refractorytowhichthisdetectorisalsosensitive.

Theultravioletsensororscannerissensitivetoultravioletradiationfromtheflame'sprimary

combustionzone.Iftheflamegoesoutthepowersupplytothefuelvalvewillbeopenedandthevalve

willclose.

Mostpackagedboilersuseascanner

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
  • 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論