![PLANNING AND DESIGN OF HYDROELECTRIC POWER PLANT STRUCTURES水電站規(guī)劃與結(jié)構(gòu)設(shè)計(jì) 3_第1頁](http://file4.renrendoc.com/view8/M00/09/18/wKhkGWbNe5yACukBAAIlO4b1gSc408.jpg)
![PLANNING AND DESIGN OF HYDROELECTRIC POWER PLANT STRUCTURES水電站規(guī)劃與結(jié)構(gòu)設(shè)計(jì) 3_第2頁](http://file4.renrendoc.com/view8/M00/09/18/wKhkGWbNe5yACukBAAIlO4b1gSc4082.jpg)
![PLANNING AND DESIGN OF HYDROELECTRIC POWER PLANT STRUCTURES水電站規(guī)劃與結(jié)構(gòu)設(shè)計(jì) 3_第3頁](http://file4.renrendoc.com/view8/M00/09/18/wKhkGWbNe5yACukBAAIlO4b1gSc4083.jpg)
![PLANNING AND DESIGN OF HYDROELECTRIC POWER PLANT STRUCTURES水電站規(guī)劃與結(jié)構(gòu)設(shè)計(jì) 3_第4頁](http://file4.renrendoc.com/view8/M00/09/18/wKhkGWbNe5yACukBAAIlO4b1gSc4084.jpg)
![PLANNING AND DESIGN OF HYDROELECTRIC POWER PLANT STRUCTURES水電站規(guī)劃與結(jié)構(gòu)設(shè)計(jì) 3_第5頁](http://file4.renrendoc.com/view8/M00/09/18/wKhkGWbNe5yACukBAAIlO4b1gSc4085.jpg)
版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
1/1
PLANNINGANDDESIGNOFHYDROELECTRICPOWERPLANTSTRUCTURES水電站規(guī)劃與結(jié)構(gòu)設(shè)計(jì)3
EM1110-2-300130Apr95Chapter5PhysicalSecurity5-1.ProtectionPlanForeveryhydropowerinstallationadetailed,writtenprotectionplanshallbedeveloped,whichwilluseavail-ableresourcesinthemostefficientmanner.Althoughtheprimaryareaofconcernshouldbeprotectionfromterroristthreats,allaspectsofprotectiondesignshouldbeaddressed.(ArecommendedsourceofadviceistheMissouriRiverDivision(MRD),theCorpsTechnicalCenterofExpertiseforProtectionDesign.)a.Typeofprotection.Indeterminingthetypeandextentofphysicalprotectionrequiredataninstallation,thefollowingpertinentfactorsshouldbetakenintoconsiderationintheindicatedsequence.(1)ImportanceofthepowersupplytoNationalSecurity,totheregionalpowerbase,andprojectopera-tionalrequirements.(2)Definitionandanalysisofareatobeprotected,andotherpertinentconsiderationinherenttotheproblemsuchasexistinghazards,eithernaturalorman-made.(Threatsfromthestoredwaterinthereservoir,fromlandslideoravalanche,fromforestorbrushfire,etc.)(3)Operation,maintenance,andotherrequirementswhichmustbeintegratedintothesecurityplan.(4)Environment-political,economic,legal,surroundingterrain,weatherandclimate.(5)Costsofmaterialandequipmenttobeinstalled,aswellasavailabilityoffundstoprovideatleastmini-mumprotectionforallcriticalareas.(6)Feasibility,personnelandequipmentcosts,andthebestmethodofprovidingadequatecosteffectiveprotection.b.Architecturaldesign.Thearchitecturaldesignofthestructureshouldincorporatenecessarysecuritydesignfeatures.(1)Aminimumofwindows,particularlyneargroundlevel.(2)Wellanchoredsteeldoorsandframes.(3)Transformersandpowertransmissionlineslocated,orprotected,todiscouragethreatactivities.c.Keyelementsindevelopingtheprotectionplan.Theresponseanalysisshouldbeassessed.Thecriticalitemtobeestimatedistheresponsetimeforsecurityforces(projectguards,locallawenforcementagents,etc.)toreachtheinstallationoncetheyarealerted.Thepowerhouseoperatorshouldnotbeconsideredapartofthesecurityforces.Oncetheresponsetimeisestimated,thenathreatanalysisshouldbeperformed.Thiswouldconsiderthemostprobablerouteofintruderstothemostvulnerableareasofthehydropowerinstallation.Thenvariousdelayzones(fences,walls,etc.)shouldbecon-sidered,eachwithitsownintrusiondetectionsystem.Thethreatanalysisshouldresultinaseriesofdelayzonessothatthetotaltimefortheintruderstoreachcriticalareaofthehydropowerinstallations,fromfirstdetection,exceedstheresponsetimebysecurityforces.5-1EM1110-2-300130Apr95Chapter6RetrofittingExistingProjects6-1.GeneralTheadditionofhydropowerfacilitiesattheexistingCorpsofEngineersprojectsmustnotjeopardizethepublicinterestrelativetowatercontrolmanagementforfloodcontrol,navigation,watersupply,waterquality,recreationandotherprojectproposes.Inaddition,thoseaspectsofthedesignthatcouldaffectthesafetyoftheprojectmustbeconsistentwithCorpsstandardsastorequirementsofthismanualandallreferencedmanualsandregulations.Toensurecompliancewiththispolicywhendevelopmentisbynon-federallicenses,theCorpsofEngineerswillreviewandapprovetheproposeddetaileddesignanalysisandplansandspecificationsforthosehydraulic,structuralandmechanicalfeaturesthatcouldaffecttheintegrityandsafetyofthetotalproject.Majoritemsofconcern,butnotnecessarilylimitedto,arediscussedasfollows:6-2.HydraulicDesignConsiderationsa.Proposals.Proposalstoaddhydropowerfacili-tiesatCorpsofEngineersprojectsmustthoroughlyaddressthehydraulicdesigndetailsandtheoverallfunc-tionalcapability.Itemsthatmustbeaddressedincludethefollowing.(1)Streamliningofentrancetopowerpenstockfromfloodcontrolconduitmustbeaddressed.(2)Streamliningtoprecludecavitationinfloodcon-trolconduitatjunctionswithpenstockorgateslotsmustbeaddressed.(3)Positiveandnegativepressuresurgesduetopowerhouseloadrejections,loadacceptance,andunitrunawayisanotherimportantitemtoaddress.(4)Reassessmentofwaterqualityprovisionstoincludesizeandlocationofmulti-levelintakesandcom-patibilityofpowerhousereleaserequirementswithwaterqualityrequirementsisanimportantitem.(5)Meansofdewateringpowerfacilitieswithoutinterruptingwaterqualityand/orfloodcontrolreleasesmustbeaddressed.However,somepowerhouseswithlongpenstocks,orthosewithonlygatesorvalvesimme-diatelyupstreamofthepowerplantneednotbedewateredexceptunderemergencyconditions.Thisprocedurecanbefollowedonlyifitdoesnotimpactupondamsafetyoffloodcontrolregulations.Thistypeofpenstockcanbeinspectedusingdiversorremotelyoperatedcameras.(6)Effectsofaddingtrashracksintheexistingintakeifrequiredforequipmentprotectionmustbeaddressed.b.Submittals.SubmittalsproposinginclusionoradditionofhydropowercombinedwithwaterqualityandorfloodcontrolfacilitiesatCorpsofEngineersprojectsmustincludeahydraulicdesignanalysiscoveringalloperatingandemergencyconditions.Presentationsneedtoaddressallitemsdiscussedabove.Informationonenergyandpressuregradelinesthroughoutthehydraulicpassagescoveringmaximumandminimumconditionswithlocalpressuredropsatsuchplacesasbends,junc-tions,transitions,gateslots,etc.,isnecessary.Thepre-sentationsmustincludeananalysisoftheeffectsofapowerhouseloadrejection.Thedegreeofdetailistobesufficientforthestudystagebeingpresented,althoughatfinaldesignstage.atransientanalysisutilizingstate-of-the-artcomputerprogramsmustbeperformedandreviewedbyaDesignCenter.Therequirementsapplytoproposalsfromothers(tobeaccomplishedattheirexpense)aswellastoin-houseproposals.c.Penstocks.Theexistingregulatingoutletconduitsofferanavailableconnectionbetweenthereservoirandpotentialhydropowerfacilities.Regulatingoutletcon-duitsarfloodcontrolorothernon-powerprojectsareusuallydesignedfornon-pressurized(openchannel)flowconditions.forthemostpart,theseconduitsareofrein-forcedconcretedesignedtowithstandexternalrockorembankmentloadsandexternalhydrostaticpressures.Oncehydropowerfacilityisconnected,theprimarystruc-turalconcernisthatanexistingregulatingoutletconduitbecomesapowerpenstocksubjecttointernalpressuresequaltofullpoolplusanytransientpressuresduetowatermannereffects.SubmittalsproposinginclusionoradditionoffacilitiesatCorpsofEngineersprojectsmustincludestructuralandgeotechnicalanalysiscoveringalloperatingandemergencyconditions.Presentationsneedtoaddressallitemscoveredinthisguidance.Thedegreeofdetailpresentedshouldbesufficientforthestudystagebeingpresented.Thisappliestoproposalsfromothers(tobeaccomplishedattheirexpense)aswellastoin-houseproposals.Thefollowingparagraphspresentacceptabledesigncriteriaforconvertingregulatingoutletconduitstopowerpenstock(downstreamcontrol).6-1EM1110-2-300130Apr956-3.GeotechnicalConsiderationsOriginalgeologicconditionsuponwhichprojectdesignwasbased,anduponwhichcutandcoverorlinesorunlinedtunnelswereconstructed,mustbeknownsothatsafetyandoriginaldesignbenefitsarenotreduced.Watermustnotbeallowedtoescapeintothedamabut-mentsfrompressurizedtunnelstocauseslopestabilityproblemsorgroundwaterchangesthatmightaffectthedam.Aninvestigationofgeologicconditionsrelativetothedesignproposedforapressurizedtunnelmustbemade.Existinglinedtunnelsmayconcealvoids,shearzones,rockoflowdeformationmodulus,etc.Whenmodifyingexistinglinedtunnels,designshallrecognizeandprovidefortheabovepossibilities,justasitwouldforunlinedtunnelscontaininggeologicweaknesses.Fulllengthgroutingbehindliningsorothermeasuresmaybenecessary.Ifanexistingtunnelisactingasadrainagefeatureinanabutment,intentionallyorunintentionally,thepossibilityofgroundwaterpressurechangesoccurringaftermodificationshouldbeevaluated.Thefunctionandmanyofthedetailsofconstructionanderectionforanintegrallyembeddedsteellineraresimilartoafree-standingpenstock;however,theloadingconditionsaredifferent.Thesteellining,concreteencasement,andifpresent,thesurroundingrockacttogethertoresistthepressures.EM1110-2-2901outlinesindetailtheloadingconditionsandallowablestressesforaconduitunderembankmentsorrock.Inbothinstances,externalpres-suresmustbeaccountedfroaswellastheinternalpressures.6-4.TunnelsinRockAbutmentsAnexistingoutlettunnel(unlinedorlinedwithotherthansteel)shouldbeinvestigatedtodeterminetowhatextentthetunnelshouldbelinedwithsteelplatetopre-ventleakagethatcouldpresentadangertothedamorabutment.Theextentofsteellinerplateshouldbesuffi-cienttopreventleakagealongrockfissuresorjointsthatinterceptthedamordownstreamoftheimperviouszone.Anexistingtunnellinermustbeinvestigatedforinternalpressuresthatwilloccuroncethehydropowerfacilityisinstalled.Inregionsofanexistingregulatingoutlettunnellinerwheretherockcoverisinsufficienttooffsetinternalpressures,orwheregeologicweaknessesexist,anewlinermayberequiredfrostructuralreasons.Asteellinerplatecouldbegroutedinplaceanddesignedascompositewithanexistingconcreteliner,providedtheexistinglinerreinforcementisadequateforallloads(seeEM1110-2-2901).Ifthetunnelisunlinedofiftheexistinglinerreinforcementisinadequate,aseparatefree-standingpenstockornewreinforcedconcretelinerwithcompositesteellinerplateshouldbeprovided.6-5.CutandCoverConduitsa.General.Initsexistingnon-pressurizedcondi-tion,theseconduitsaregenerallyreinforcedconcretestructureswithoutsteelplateliners.Topreventleakagethatwouldendangertheembankmentdam,asteelliningisrequiredfromtheupstreamfaceoftheimperviouszonetothepowerhouse.Areinforcedconcretelinercompositesteellinerplate,orafree-standingpenstock,mayberequiredtostructurallyaccommodatetheinternalfullpoolpressuresresultingfromdownstreamcontrolplusadditionalpressuresduetowaterhammereffects.b.Circularconduits.AsteellinergroutedtobeintegralwiththeexistingconcretelinermaybeusedprovidedtherequirementsofEM1110-2-2901aremet.Iftheexistingconcretereinforcementdoesnotmeettheaboverequirements,afree-standingtypepenstockornewreinforcedconcretelinerwithcompositesteellinerplateshouldbeprovided.c.Non-circularconduits.Afree-standingpenstock,erectedwithinandindependentoftheexistingregulatingoutletconduit,shouldbeprovided.6-6.Free-StandingPenstocksWithinConduitsFree-standingpenstocksconstructedwithinanexistingconduitshallbedesignedinaccordancewithpara-graph4-16,penstocksandsurgetanks.Platesandjointsshouldbedesignedforfullpressureduetostaticheadpluswaterhammeraswellasanynegativepressuresdevelopedbyhydraulictransients.Alljointsshouldbeweldedexceptfortheconnectionofthepenstocktothespiralcase,whichisnormallyaflexibletype.Free-standingpenstocksshouldbeconstructedsoastopermitanyleakagetodraintotailwaterwithoutpressurizingthesurroundingregulatingoutletconduit.Carefulattentionshouldbegiventoanchorageofthepenstockagainstlongitudinalthrust.a.Gatesandvalves.Theadditionofhydropowerfacilitiesmustincludeprovisionsforisolatingthepower-plantsoasnottointerferewiththeprojectoriginalpur-pose.Whentheexistingfloodcontrolconduitismodifiedforpenstockuse,aclosuredevicesuchasabutterflyorsphericalvalveoragatemustbeprovidedatthepowerhouseendofthepenstockforshutoffofflow6-2EM1110-2-300130Apr95duringemergencyclosureorduringnormalmaintenanceoftheequipment.(1)Theclosuredeviceshouldbedesignedformaxi-mumpenstockheadincludingwaterhammerandhydrostaticallytestedfor150percentofthemaximumdesignconditions.Thevalveoperatormustbecapableofclosingthedeviceinfrom2to5minutesaspracticalforitssize.Theclosurecapabilitymustbeachievablewithoutoutsidepower.Thus,anenergystoragedevicesuchasanaccumulatororcounterweightisrequired.(2)Theclosureofthenormalwaterpassageatthedownstreamendfordivertingflowtotheturbineissub-jecttothespecificprojectlayout.Gatesorvalvesusedforthispurposemustbedesignedforthemaximumwaterpressure,includingwaterhammer,andsubjecttohydrostatictestinginplace.b.Vents.Whentheexistingfloodcontrolfacilitiesareutilizedforhydropowerpurposes,alltheexistingcomponentsrequirecarefulanalyzingandinvestigationforanyadversecavitationorstructuraleffects.Onesuchitemsubjecttostructuralloadinggreaterthanoriginallythoroughanalysisoftheeffectssuchchangeswouldhaveonthesystemwhenusedintheoriginaloperationmodefortheprojectpurpose.Duringpowerhouseoperationtheventsaresubjecttofullhydrostaticpressureincludingwaterhammer,andthereforestructuraladequacyshouldbethoroughlyinvestigatedforthisconditionaswellastheseismiccondition.c.Bifurcation.Inmostinstances,theutilizationoftheexistingregulatingconduitrequiresdivertingthewaterflowfromtheconduittothepowerproducingfacilities.Themethodofaccomplishingthisobjectiverequiresabifurcationordivertingboxdependingofthespecificsiteconditions.Themethodchosenmustbethoroughlyanalyzedforpotentialcavitationorstructuraleffectsandmayrequiremodeltestingtoverifythedesign.Forfurtherstructuralrequirements,seeparagraph4-16e.6-3EM1110-2-300130Apr95AppendixAReferencesA-1.RequiredPublicationsTM5-809-1LoadAssumptionsforBuildingsTM5-809-10SeismicDesignofBuildingsTM5-810-1MechanicalDesign,HVACER1110-2-109HydroelectricDesignCenterER1110-2-1454Non-FederalHydropowerER1110-2-1806EarthquakeDesignandAnalysisforCorpsofEngineersDamsEM1110-2-1902StabilityofEarthandRockfillDamsEM1110-2-2000StandardPracticeforConcreteEM1110-2-2104StrengthDesignforReinforced-ConcreteHydraulicStructuresEM1110-2-2105DesignofHydraulicSteelStructuresEM1110-2-2200GravityDamDesignEM1110-2-2502RetainingandFloodwallsEM1110-2-2901TunnelsandShaftsinRockEM1110-2-2906DesignofPileFoundationsEM1110-2-3506GroutingTechnologyEM1110-2-4203DesignDataforPowerhouseCranesEM1110-2-4205HydroelectricPowerPlantMechanicalDesignETL1110-2-256SlidingStabilityforConcreteStructures(ETLsaretemporarydocumentsandsubjecttochange)ETL1110-2-301InterimProceduresforSpecifyingEarthquakeMotionsETL1110-2-303EarthquakeAnalysisandDesignofConcreteGravityDamsCE-1602DamGantryCranesCE-1603DraftTubeGantryCranesCE-1604.01IndoorElectricallyOperatedTravelingCranesCE-1604.02IndoorElectricallyOperatedTravelingCranesCE-4000Lump-SumContractforDesignofHydroelectricP
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 現(xiàn)代金融業(yè)務(wù)中的稅收籌劃與合規(guī)性
- 電子電路設(shè)計(jì)與制作實(shí)戰(zhàn)教程
- 中國泳池系統(tǒng)行業(yè)市場(chǎng)發(fā)展前景及發(fā)展趨勢(shì)與投資戰(zhàn)略研究報(bào)告(2024-2030)
- 環(huán)保企業(yè)的社會(huì)責(zé)任與市場(chǎng)機(jī)遇
- 電影產(chǎn)業(yè)知識(shí)產(chǎn)權(quán)的轉(zhuǎn)讓與授權(quán)機(jī)制
- 2025年中國汽車美容行業(yè)市場(chǎng)調(diào)研分析及投資戰(zhàn)略規(guī)劃報(bào)告
- 中國船舶代理市場(chǎng)運(yùn)行態(tài)勢(shì)及行業(yè)發(fā)展前景預(yù)測(cè)報(bào)告
- 公司股分紅合同范本
- 2024-2030年中國公共關(guān)系軟件行業(yè)市場(chǎng)全景監(jiān)測(cè)及投資戰(zhàn)略咨詢報(bào)告
- 供暖設(shè)施改造合同范本
- (2024版)中國血脂管理指南
- 集成墻板購銷合同范本(2024版)
- 2023九年級(jí)歷史下冊(cè) 第三單元 第一次世界大戰(zhàn)和戰(zhàn)后初期的世界第10課《凡爾賽條約》和《九國公約》教案 新人教版
- 偏癱患者肩關(guān)節(jié)脫位的綜合康復(fù)治療
- 持續(xù)質(zhì)量改進(jìn)項(xiàng)目匯報(bào)
- 2024版買賣二手車合同范本
- 阻燃更要消煙一文讓你掌握無煙阻燃改性技術(shù)的方方面面
- 第15課 列強(qiáng)入侵與中國人民的反抗斗爭(zhēng) 教學(xué)設(shè)計(jì)-2023-2024學(xué)年中職高一上學(xué)期高教版(2023)中國歷史全一冊(cè)
- 2023年人教版七年級(jí)歷史下冊(cè)《全冊(cè)課件》
- 新大象版科學(xué)三年級(jí)下冊(cè)全冊(cè)知識(shí)點(diǎn) (復(fù)習(xí)用)
- 2024年黑龍江省專升本考試生理學(xué)護(hù)理學(xué)專業(yè)測(cè)試題含解析
評(píng)論
0/150
提交評(píng)論