ICS點(diǎn)擊此處添加ICS號(hào)點(diǎn)擊此處添加中國(guó)標(biāo)準(zhǔn)文獻(xiàn)分類號(hào)T/CECT/CEC-XXXXTechnicalspecificationofexternalcircuit-breakerforelectricitymeters電能表用外置斷路器技術(shù)規(guī)范點(diǎn)擊此處添加與國(guó)際標(biāo)準(zhǔn)一致性程度的標(biāo)識(shí)(征求意見(jiàn)稿)XXXX-XX-XX發(fā)布XXXX-XX-XX實(shí)施發(fā)布T/CEC—XXXXT/CEC—XXXXTechnicalspecificationofcircuit-breakersforelectricitymetersScopeThisstandardstatestheclassification,typeofstructure,technicalrequirements,testmethodsandsoonoftheexternalcircuit-breakersforelectricitymeters(hereinafterreferredtoascircuit-breaker).Thisstandardappliestoa.c.circuit-breakerforoperationat50Hz,60Hzor50/60Hz,hacingaratedvoltagenotexceedingAC400?V,aratedcurrentnotexceeding125?A,andratedshort-circuitbreakingcapacitynotlessthan6000?A.NormativereferencesThefollowingdocumentsareindispensablefortheapplicationthisdocument.Fordatedreference,onlytheeditioncitedapplies.Forundatedreferences,thelatesteditionofthereferenceddocument(includinganyamendments)applies.GB/T1804—2000GeneraltolerancesTolerancesforlinearandangulardimensionswithoutindividualtoleranceindicationsGB10963.1—2005Electricalaccessories-Circuit-breakersforovercurrentprotectionforhouseholdandsimilarinstallation-Part1:Circuit-breakersfora.c.operationGB14048.1-2012Low-voltageswitchgearandcontrolgear--Part1:GeneralrulesGB/T17626.2—2006Electromagneticcompatibility(EMC)--Testingandmeasurementtechniques--ElectrostaticdischargeimmunitytestGB/T17626.4—2008Electromagneticcompatibility-Testingandmeasurementtechniques--Electricalfasttransient/burstimmunitytestGB/T17626.5—2006Electromagneticcompatibility-Testingandmeasurementtechniques--SurgeimmunitytestGB17701—2008Circuit-breakerforequipmentGB/T19334—2003Dimensionoflow-voltageswitchgearandcontrolgear--StandardizedmountingonrailsformechanicalsupportofelectricaldevicesinswitchgearandcontrolgearinstallationsGB/T20645—2006Specificenvironmentalcondition--Technicalrequirementsoflow-voltageapparatusesforplateauGB/T26572—2011RequirementsofconcentrationlimitsforcertainrestrictedsubstancesinelectricalandelectronicproductsIEC62055-31:2005Electricitymetering--Paymentsystems--Part31:Particularrequirements--Staticpaymentmetersforactiveenergy(classes1and2))TermsanddefinitionsForthepurposeofthisdocument,thetermsanddefinitionsgiveninGB14048.1—2012,aswellasthefollowingapply.circuit-breakerMechanicalswitchingdevice,capableofmaking,carryingandbreakingcurrentsundernormalcircuitconditionsandalsomaking,carryingforaspecifiedtimeandbreakingcurrentsunderspecifiedabnormalcircuitconditions(suchasshort-circuitcondition).[SOURCE:GB14048.1,2.2.11]externalcircuit-breakerforelectricitymetersThecircuit-breaker,installedexternallyandcooperatedwiththeelectricitymetertocontrolitsopeningandclosingoperation.automaticopeningandclosingoperationOpeningandclosingoperationofthecircuit-breakerthat,bymeansofremotecontrolsignalsfrommasterstationorotherequipment.(Operationofopeningorclosingthecircuitbreakerbyremotecontrolsignalsfromthemasterstationorotherequipment)automaticopeningandclosingtimeTimemeasuredfromtheinstantatwhichthecircuit-breakerreceivestheopeningorclosingsignaltotheinstantwhenopeningorclosingoperationisaccomplished.innershaftdrivemodeDrivingmodethatenableseachpoletooperatetogetherbymeansofintegralshaftinthecircuitbreaker.power-ondelaytimeTheintervaltimebetweenthepowering-upandreadyforresponsetocontrolsignal.(Thedurationfromtheinstantofpower-ontotheinstantatwhichthebreakerisreadytorespondtoacontrolsignal)3.7synchronoustimeThetimeperiodamongeachpoleofthecircuit-breakertocompleteitsopeningorclosingoperation.(Timedifferenceamongallpolesofabreakertocompleteitsopeningorclosingoperation.)Classificationandperformancerequirements4.1ClassificationAccordingtothenumberofpolesAccordingtothenumberofpoles:1P+N,two-polecircuit-breakerswithoneprotectedpole;2P,two-polecircuit-breakerswithtwoprotectedpoles;3P,three-polecircuit-breakerswiththreeprotectedpoles;3P+N,four-polecircuit-breakerswiththreeprotectedpoles;4P,four-polecircuit-breakerswithfourprotectedpoles.Note:Thepolewhichisnotaprotectedpolecanbe“switchedneutral”.Accordingtoinstallationmethods(Accordingtothemethodofmounting)Surface-type;Flush-type;c) Panelboardtype,alsoreferredtoasdistributionboardtype.Note:Thesetypesmaybeintendedtoberailmounted.(Accordingtothemethodofcontrol)Accordingtothemethodofcontrol:Manualcontrol,tocloseandopenmanuallySemi-automaticcontrol,toclosemanuallyandopenautomatically,Automaticcontrol,tocloseandopenautomatically,Semi-automaticorRemoteautomaticcontrolselectionmode,Havingmodeswitchforselectionofmanualorautomaticmode.Wheninmanualmode,functioningasinremotesemi-automaticcontrolmode.Wheninautomaticmode,functioningasinremoteautomaticcontrolmode.Accordingtotheinstantaneoustrippingcurrenta)B-type;b)C-type;c)D-type.Note:Theselectionofaparticulartypecandependontheinstallationrules.CharacteristicsrequirementsControlsignalvoltageTheratedcontrolsignalvoltageshallbeAC220V.Ratedvoltage(Ue)PreferredvaluesofratedvoltagearegiveninTable1.Table1PreferredvaluesofratedvoltageCircuit-breakersCircuitsupplyingthecircuit-breakerRatedvoltageofcircuit-breakersforuseinsystems230?V、230/400?V、400?VVRatedvoltageofcircuit-breakersforuseinsystems240?VVSinglepoleSinglephase(phasetoneutralorphasetophase)230/Three-phasefour-wire230/Single-phase(phasetoneutral)orthreephase,usingthreesingle-polecircuit-breakers(three-wireorfour-wire)230/400/Two-poleSinglephase(phasetoneutralorphasetophase)230/Singlephase(phasetophase)400240Singlephase(phasetophase,three-wire)/240Threephase(four-wire)230/Three-poleThree-phase(three-wireorfour-wire)400240Four-poleThree-phase(four-wire)400/Note1:InIEC60038,thenetworkvoltagevalueof230/400?Vhasbeenstandardized.Thisvaluewillprogressivelysupersedethevaluesof220/380?Vand240/415?V.Note2:Whereverinthisstandardthereisareferenceto230?Vor400?V,theycanbereadas220?Vor240?V,380?Vor415?V,respectively.Note3:Whereverinthisstandardthereisareferenceto240?V,theycanbereadas200?V.Ratedinsulationvoltage(Ui)Theratedinsulationvoltageshallnotbelessthan500?V.Ratedimpulsewithstandvoltage(Uimp)Theratedimpulsewithstandvoltageshallnotbelessthan6?kV.Ratedcurrent(In)Preferredvaluesofratedcurrentare:40?A,63?A,80?A,100?Aand125?A.Ratedfrequency(fn)Standardvaluesofratedfrequencyare50?Hzand60?Hz.Ratedshort-circuitcapacity(Icn)Theratedshort-circuitbreakingcapacityshallnotbelessthan6000?A.Automaticclosingtime(tc)tc≤3?s。SynchronoustimeThesynchronoustimeofacircuit-breakershallmeettherequirementsofitsproductspecification.Power-ondelaytime(te)Thepower-updelaytimeofcircuit-breakersshouldbesatisfiedwiththerequirementsoftheproductspecification.(Thepower-ondelaytimeofacircuitbreakershallmeettherequirementsofitsproductspecification.)Ratedcontrolsignalvoltage(Uc)TheratedcontrolsignalvoltageshallbeAC220?V.Controlsignalcurrent(Ic)Ic≤1?mA。Closingphaseleakagecurrent(IL1)Steady-statecurrentlossperphaseshallbelessthan0.2?mAwhenthecontrolunitsareattheclosedposition.Openingphaseleakagecurrent(IL2)Steady-statecurrentlossperphaseshallbevlessthan0.2?mAwhenthecontrolunitsareattheopenposition.PowerlossThemaximumpermissiblevaluesperpoleofcircuit-breakersareindicatedinTable2.Table2–MaximumpowerlossperpoleRangeofratedcurrentInAMaximumpowerlossperpoleW32<In≤406.540<In≤50850<In≤6311.563<In≤10013.5100<In≤12518PollutiondegreeCircuit-breakerstothisstandardareintendedforenvironmentwithpollutiondegree2,i.e.normallyonlynon-conductivepollutionoccurs;occasionally,however,atemporaryconductivitycausedbycondensationmaybeexpected.ConstructionalrequirementsGeneralCircuit-breakersshallbesodesignedandconstructedthat,innormaluse,theirperformanceisreliableandwithoutdangertotheuserorsurroundings.Complianceischeckedbycarryingoutalltherelevanttestsspecified.AppearanceMetalpartsofthecircuitbreakershallbeadequatelyplatedandcoatedagainstrusting.Metalpartsshallnothavecracks,pittingorpeeling.Thesurfaceoftheplasticpartsshallbesmoothwithoutblisters,cracks,dents,orotherdefects.Externalpartswhichareaccessiblewhenoperatingthecircuit-breakershallbemadeofinsulatingmaterial.Dimensionsofcircuit-breakersarespecifiedinAnnexAOperatingmechanismTheoperatingmechanismofacircuitbreakershallmeetthefollowingrequirements:Theoperatingpartsmustbeflexibleandreliable,anditshallhaveatrip-freemechanism;Forautomaticcontrolapoweroperatingmechanismshallbeprovided;Themovingcontactscancometorestonlyintheclosedoropenposition,eveniftheoperatingmemberistrippedinanintermediatepositionThecircuitbreakershallbeprovidedwithanoperatinghandleformanuallyopeningandclosing,theoperatinghandlemustbesecuredreliably;Goodinsulationbetweenoperatinghandleandlivepartsshouldberealizedtoensuresafety;Themovingcontactsofallpolesofmultipolecircuitbreakersshallbesomechanicallycoupledthatallpoles,excepttheswitchedneutral,makeandbreaksubstantiallytogether,evenifanoverloadoccursononeprotectedpoleonly.Theswitchedneutralpole,ifavailable,shallnotcloseafterandshallnotopenbeforetheprotectedpoles;Ifapolehavinganappropriateshortcircuitmakingandbreakingcapacityisusedasaneutralpole,andthecircuitbreakerisindependentofmanualoperation,allpolesincludetheneutralpolemayoperatesubstantiallytogether;Exceptinmanualcontrolmode,whenreceivingatripcommand,theacircuitbreakershallopenautomaticallyandthemovingcontactsshallstayintheopenposition,andcouldn’tbeclosedmanually;Abreakerunderclosingcommandshallallowmanuallyopenorclose.Afteropening,itshallstayinopenpositionincaseofapower-offandreenergizing;Foracircuitbreakersupportingautomaticcontrolmode,theautomaticclosingmoduleshallemployatotallyenclosedconstructionwithinnershaftdriving,torealizeautomaticclosingfunctionandtoensuremovingcontactsstayintheopenpositionwhenmanuallyclosingabreakwhichisinopenstate.IsolationprotectionEachpoleofcircuit-breakersshallreliablybreakintheopenposition.Circuit-breakersshallprovideintheopenpositionanisolationdistanceinaccordancewiththerequirementsnecessarytosatisfytheisolatingfunction.Indicationoftheopenandclosedpositionofthemaincontactsshallbeprovidedbybothofthefollowingmeans:a)thepositionoftheactuator;b)aseparatemechanicalindicator.(Mechanicalindicatorandactuator)Indicationoftheopenandclosedpositionofthemaincontactsshallbeprovided.Itshallbepossibletoswitchthecircuit-breakeronandoffbyhand.Amechanicalindicatorisusedtoindicatethepositionofthecontacts,thisshallshowthesymbol“|”(or“closed”,“ON”,“red”)fortheclosedpositionandthesymbol“○”(or“open”,“OFF”,“green”)fortheopenposition(OFF).Indicationofthecontactpositionshallbereliable.Circuit-breakersshallbedesignedsothattheactuator,frontplateorcovercanonlybecorrectlyfittedinamannerwhichensurescorrectindicationofthecontactposition.ModeselectionswitchForcircuit-breakerswithsemi-automaticandautomaticcontrolmode,amodeswitchshallbeprovidedinthefronttoselectsemi-automaticcontrolmodeandremoteautomaticcontrolmode.Modeswitchshallbedesignedonthefrontalsideofthecircuit-breaker,andwiththeidentificationof“Automatic”and“Manual”forindicatingthemodeatpresent.Protectionmeasuresshallbetakentopreventthemodeswitchfromtamperinganditshallnotbepossibletoselectamodewithouttheaidofatool.Screws,current-carryingpartsandconnections5.7.1ScrewsandconnectionsConnections,whetherelectricalormechanical,shallwithstandthemechanicalstressesoccurringinnormaluse.5.7.2ElectricalconnectionsElectricalconnectionsshallbesodesignedthatcontactpressureisnottransmittedthroughinsulatingmaterialotherthanceramic,puremicaorothermaterialwithcharacteristicsnolesssuitable,unlessthereissufficientresilienceinthemetallicpartstocompensateforanypossibleshrinkageoryieldingoftheinsulatingmaterial.5.7.3Current-carryingpartsandconnectionsCurrent-carryingpartsincludingpartsintendedforprotectiveconductorsshallbemadeof——copper;——analloycontainingatleast58%copperforpartsworkedcold,oratleast50%copperforotherparts;——othermetalorsuitablycoatedmetal,nolessresistanttocorrosionthancopperandhavingmechanicalpropertiesnolesssuitable.Note:Incaseofusingferrousalloysorsuitablycoatedferrousalloys,compliancetoresistancetocorrosionischeckedbyatestofresistancetorusting.Therequirementsofthissubclausedonotapplytocontacts,magneticcircuits,heaterelements,bimetals,shunts,partsofelectronicdevicesortoscrews,nuts,washers,clampingplates,similarpartsofterminalsandpartsofthetestcircuit.TerminalsforexternalconductorsTerminalsforexternalconductorsshallbesuchthattheconductorsmaybeconnectedsoastoensurethatthenecessarycontactpressureismaintainedpermanently.Connectionarrangementsintendedforbusbarconnectionareadmissible,providedtheyarenotusedfortheconnectionofcables.Sucharrangementsmaybeofthebolt-ontype.Theterminalsshallbereadilyaccessibleundertheintendedconditionsofuse.Circuit-breakersshallbeprovidedwithterminalswhichshallallowtheconnectionofcopperconductorshavingnominalcross-sectionalareasasshowninTable3.Table3Connectablecross-sectionsofcopperconductorsforscrew-typeterminalsRatedcurrentInACross-sectionalareaofthewireSmm232<In≤501050<In≤631663<In≤802580<In≤10035100<In≤12550Foracurrentratingnotspecified,ifrequired,complianceischeckedbyrelevantnationalstandards.Itisrequiredthat,forcurrentratingsuptoandincluding50A,terminalsbedesignedtoclampsolidconductorsandrigidstrandedconductors,flexibleconductorsmayalsobeused.Themeansforclampingtheconductorsintheterminalsshallnotservetofixanyothercomponent.Terminalsshallhaveadequatemechanicalstrength.ScrewsandnutsforclampingtheconductorsshallhaveametricISOthreadorathreadcomparableinpitchandmechanicalstrength.Terminalsshallbesodesignedthattheyclamptheconductorwithoutunduedamagetotheconductor.Terminalsshallbesodesignedthattheyclamptheconductorreliablyandbetweenmetalsurfaces.Terminalsshallbesodesignedorpositionedthatneitherarigidsolidconductornorawireofastrandedconductorcanslipoutwhiletheclampingscrewsornutsaretightened.Terminalsshallbesofixedorlocatedthat,whentheclampingscrewsornutsaretightenedorloosened,theterminalsshallnotworkloosefromtheirfixingstocircuit-breakers.Clampingscrewsornutsofterminalsintendedfortheconnectionofprotectiveconductorsshallbeadequatelysecuredagainstaccidentalloosening.Pillarterminalsshallallowfullinsertionandreliableclampingoftheconductor.Complianceischeckedbyinspectionafterarigidconductorofthelargestcross-sectionalareaspecifiedfortherelevantratedcurrentinTable3hasbeenfullyinsertedandfullyclampedbyapplyingthetorquesaccordingtoTable4.Table4–ScrewthreaddiameterandappliedtorqueScrewthreaddiametermmTorqueNmⅠⅡⅢ≤2.8>2.8~≤3.0>3.0~≤3.2>3.2~≤3.6>3.6~≤4.1>4.1~≤4.7>4.7~≤5.3>5.3~≤6.0>6.0~≤8.0>8.0~≤10.0>10.0~≤12.0>12.0~≤15.0>15.0~≤20.0>20.0~≤24.0>24.0——————2.0—————2.03.06.010.014.019.025.036.050.0Note1.ColumnIappliestoscrewswithoutheadsifthescrew,whentightened,doesnotprotrudefromthehole,andtootherscrewswhichcannotbetightenedbymeansofascrewdriverwithabladewiderthanthediameterofthescrew.Note2.ColumnIIappliestootherscrewswhicharetightenedbymeansofascrewdriver.Note3.ColumnIIIappliestoscrewsandnutswhicharetightenedbymeansotherthanascrewdriver.Screwsandnutsofterminalsintendedfortheconnectionofexternalconductorsshallbeinengagementwithametalthreadandthescrewsshallnotbeofthetappingscrewtype.SignalfeedbackmodeThecontrolsignalisanAC220Vsignal.Thecontrolunitispoweredbythecontrollineorbythephaselinetransientlyduringtheopeningandclosingoperations.Theleakagecurrentofphaseaftertheclosingoropeningoperationshallcomplywiththerequirementsof4.2.13and4.2.14respectively.ThefeedbacksignalisanAC220Vsignal.Thefeedbacksignalispoweredbythephaselineforsingle-phasecircuit-breakers.Forthree-phasecircuit-breakersthefeedbacksignalispoweredbythreephasesandshallensureproperfeedbackevenunderanyonephaseloss..Thecontrolwireandthefeedbacksignalwireshallhaveacross-sectionalareanolessthan0.3?mm2,withcrimpedlugsatbothendstopreventinverseconnection.Specificationsmaybeinaccordancewiththemanufacturer'sinstructions.ProtectionagainstelectricshockCircuit-breakersshallbesodesignedthat,whentheyaremountedandwiredasfornormaluse,livepartsarenotaccessible.Externalparts,otherthanscrewsorothermeansforfixingcoversandlabels,shalleitherbeofinsulatingmaterialorbelinedthroughoutwithinsulatingmaterial,unlessthelivepartsarewithinaninternalenclosureofinsulatingmaterial.Liningsshallbefixedinsuchawaythattheyarenotlikelytobelostduringinstallationofthecircuit-breakers.Theyshallhaveadequatethicknessandmechanicalstrengthandshallprovideadequateprotectionatplaceswheresharpedgesoccur.Inletopeningsforcablesorconduitsshalleitherbeofinsulatingmaterialorbeprovidedwithbushingsorsimilardevicesofinsulatingmaterial.Suchdevicesshallbereliablyfixedandshallhaveadequatemechanicalstrength.Metallicoperatingmeansshallbeinsulatedfromlivepartsandtheirexposedconductivepartsshallbecoveredbyinsulatingmaterial.Thisrequirementdoesnotapplytomeansforcouplinginsulatedoperatingmeansofseveralpoles.Metalpartsofthemechanismshallnotbeaccessible.TechnicalRequirements6.1Basicrequirements6.1.1AmbientairtemperaturerangeTheambientairtemperatureshallcomplywiththosespecifiedinTable5.Table5AmbientairtemperaturerangeNo.ConditionTemperaturerange(℃)1Specifiedoperatingtemperature-25~652Limittemperature-40~706.1.2HumidityrangeTherelativehumidityoftheairshallcomplywiththosespecifiedinTable6.Table6RelativeAirHumidityNo.ConditionRelativehumidity1Annualaverage<75%230days(thesedaysaredistributedinanaturalwaythroughouttheyear)95%3Occasionallyoccuronotherdays85%6.1.3Atmosphericconditions63.0?kPa~106.0?kPa(海拔2000?m及以下),特殊訂貨要求除外。高海拔地區(qū)的要求應(yīng)按照標(biāo)準(zhǔn)GB/T20645—2006中7.2.2的要求進(jìn)行修正。63.0kPa~106.0kPa(thealtitudedoesnotexceed2000?m),exceptforspecialorderrequirements.Therequirementsathigheraltitudesshallbemodifiedinaccordancewiththerequirementsof7.2.2ofGB/T20645-200InstallationmethodThecircuit-breakershallbeinstalledinaccordancewiththemanufacturer'sinstructions.(IEC-60898-1-2005)Thecircuit-breakershallbeinstalledinaccordancewiththemanufacturer'sinstructions.Thecircuit-breakershallemploythestandardrailwithawidthof35mm,asspecifiedinGB/T19334-2003.ElectricalRequirementsElectricalclearancesandcreepagedistancesGB10963.1—2005中8.1.3適用。8.1.3OfGB10963.1-2005applies.a)theclearanceofthecircuit-breakershallnotbelessthan5.5?mm;b)Thecreepagedistanceofthecircuitbreakershallnotbelessthan6.3mm.DielectricpropertiesCircuit-breakersshallhaveadequatedielectricpropertiesatpowerfrequency,andbesuitableforisolation.Theleakagecurrentshallbelowerthan100mA.InsulationresistanceAfterhumiditytreatment,insulationresistanceshallnotbelessthan2M?betweeneachpairoftheterminalsandbetweeneachpoleandtheothersconnectedtogether.Insulationresistanceshallnotbelessthan5M?betweenallpolesconnectedtogetherandtheframe,andbetweenmetalpartsofthemechanismandtheframe.ImpulsewithstandvoltageCircuit-breakersshalladequatelywithstandimpulsevoltages.Thebreakershallwithstandanimpulsewithstandvoltageofbe6?kVappliedbetweenopencontacts,betweenthephasepole(s)andtheneutralpoleconnectedtogether(asappropriate),betweeneachpoleandtheotherpolesconnectedtogetherThebreakershallwithstandanimpulsewithstandvoltageof8?kVappliedbetweenphasepole(s)andthemetalsupportTemperature-riselimitsThetemperaturerisesofthepartsofacircuit-breaker,measuredunderthenormaloperatingconditions,shallnotexceedthelimitingvaluesstatedinTable7.Thecircuit-breakershallnotsufferdamageimpairingitsfunctionsanditssafeuse.Table7–Temperature-risevaluesPartsa)b)Temperature-riseKTerminalsforexternalconnectionscExternalpartsliabletobetouchedduringmanualoperationofthecircuit-breaker,includingoperatingmeansofinsulatingmaterialandmetallicmeansforcouplinginsulatedoperatingmeansofseveralpolesExternalmetallicpartsofoperatingmeansOtherexternalparts,includingthatfaceofthecircuit-breakerindirectcontactwiththemountingsurface60402560aNovalueisspecifiedforthecontacts,sincethedesignofmostcircuit-breakersissuchthatadirectmeasurementofthetemperatureofthosepartscannotbemadewithouttheriskofcausingalterationsordisplacementsofpartslikelytoaffectthereproducibilityofthetests.The28-daytest(see9.9)isconsideredtobesufficientforcheckingindirectlythebehaviourofthecontactswithrespecttoundueoverheatinginservice.bNovalueisspecifiedforpartsotherthanthoselisted,butnodamageshallbecausedtoadjacentpartsofinsulatingmaterials,andtheoperationofthecircuit-breakershallnotbeimpaired.cForplug-intypecircuit-breakers,theterminalsofthebaseonwhichtheyareinstalled.Trippingcharacteristics8.6ofGB10963.1-2005applies.Thetime-currentcharacteristicsofB,CandD-typecircuit-breakersshallmeettherequirementsstatedinTable8.Table8Time-currentoperatingcharacteristicsTestTypeTestcurrentInitialconditionLimitsoftrippingornon-trippingtimeResulttobeobtainedRemarksaB、C、D1.13InColdat≤1h(forIn≤63A)

t≤2h(forIn>63A)Notripping/bB、C、D1.45InImmediateyfollowingtestat<1h(forIn≤63A)

t<2h(forIn>63A)TrippingCurrentsteadilyincreasedwithin5scB、C、D2.55InColda1s<t<60s(forIn≤32A)

1s<t<120s(forIn>32A)Tripping/dB、C、D3In5In10InColdat≤0.1sNotrippingCurrentestablishedbyclosinganauxiliaryswitcheB、C、D5In10In20InbColdat<0.1sTrippingCurrentestablishedbyclosinganauxiliaryswitchaTheterm"cold"meanswithoutpreviousloading.b50Inforspecialcases.Short-circuitperformancerequirementsThesameasinGB10963.1-2005ofGB10963.1-2005applies.MechanicalperformancerequirementsAfterthemechanicalshocktest,thecircuit-breakershallshownomechanicaldamageimpairingitsfurtheruse,andoperateproperlybybothmanualoperationandremotecontrol.Duringthetest,thecircuit-breakershallnotchangeitsstate.Materialperformancerequirements6.5.1ResistancetoheatResistancetoheatshallcomplywiththerequirementsof8.10ofGB10963.1-2005.6.5.2ResistancetoabnormalheatandfireResistancetoabnormalheatandtofireshallcomplywiththerequirementsof8.11ofGB10963.1-200VerificationofresistancetorustingResistancetorustingshallcomplywiththerequirementsof8.12ofGB10963.1-2005.Ferrouspartsshallbeadequatelyprotectedagainstrusting.Reliabilityrequirements28-dayoperationalrequirementsThecircuitbreakershallbesubjectedtoa28-daytestaccordingtothetestrequirementsof9.9ofGB10963.1-2005.Thetemperatureriseofthecircuit-breakershallbemeasuredafterthetest,andshallcomplywiththerequirementsgivenbyTable7.MechanicalendurancerequirementsTheoperationalperformancetestshallbeperformedwithnocurrentinthemaincircuitaccordingto9.11ofGB10963.1—2005.Eachoperatingcycleconsistsofaclosingoperationfollowedbyanopeningoperation.Incaseofcircuit-breakerswithremotesemi-automaticandremoteautomaticcontrolmode,thecircuit-breakershallbeoperatedwithremotecontrol.Theoperatingfrequencyshallbe6operatingcyclesperminute.Thecircuit-breakerissubmittedto10000operatingcycles,andshallnotshow:a)unduewear,powerlossvariationrateperpolegreaterthan20%;b)discrepancybetweenthepositionofmovingcontactsandofthecorrespondingpositionoftheindicatingdevice;c)damagetotheenclosurepermittingaccesstolivepartsbythetestfinger;d)looseningofelectricalormechanicalconnections;e)seepageofsealingcompound.Forspecialrequirements,thetestsshallbecarriedoutunderspecifiedconditionsElectricalendurancerequirementsTheoperationalperformancetestshallbeperformedwithratedcurrentinthemaincircuitaccordingto9.11ofGB10963.1—2005.Eachoperatingcycleconsistsofamakingoperationfollowedbyabreakingoperation.Incaseofcircuit-breakerswithremotesemi-automaticandremoteautomaticcontrolmode,thecircuit-breakershallbeoperatedwithremotecontrol.Duringeachoperatingcyclethecircuit-breakershallremainopenforatleast28s.Thecircuit-breakerissubmittedto4000operatingcycles,andshallnotshow:a)unduewear,powerlossvariationrateperpolegreaterthan20%orexceedstandardpowerloss;b)discrepancybetweenthepositionofmovingcontactsandofthecorrespondingpositionoftheindicatingdevice;c)damagetotheenclosurepermittingaccesstolivepartsbythetestfinger;d)looseningofelectricalormechanicalconnections;e)seepageofsealingcompound.ControlmethodrequirementsForcircuit-breakercontrolling,theratedcontrolvoltagesignalisused.Feedbackofthecircuit

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論