智能醫(yī)院控制系統(tǒng)中英文對照外文翻譯文獻智能醫(yī)院控制系統(tǒng)中英文對照外文翻譯文獻(文檔含英文原文和中文翻譯)原文: 2.4GHzT-busEIBsmarthospitalcontrolsystemModernizedhospitalconstructionfunctioniscomplicated,medicalequipmentisprecise,theenvironmentrequeststandardishigh,using2.4GHzT-busintelligencecontrolsystemcanconnecttothehospitalconstructionenvironment.Throughtheestablishmentofdigitizationenergyconservationmedicalserviceenvironment,mayenhancethehospitalmanagementlevel,enhancesmedicalpersonnel'sworkingefficiency,savethehospitaloperationcosts.T-busintelligenceenvironmentcontrolsystemrealizetheoptimizingcontroltothelightenvironment,thevisorenvironment,thetemperatureenvironmentandthemedicalequipmentmovementandmaintenanceofmanyhospitaldepartmentssuchasoutpatientclinic,thein-patientdepartmentandsoonthroughcontrollingtoeachkindofterminalelectricalequipment(forexamplelight,electricalwindowcurtain,airconditioners,medicalequipmentandsoon).Purposes:
1.UniformlyManages,controlsandprotectsthehospitalillumination,airconditionersandthemedicalequipment
2.Enhancesthehospitalservicescale,providesthecomfortableenvironmenttothemedicalpersonandthepatients.
3.Savetheenergy,savesthehospitaloperationcosts
4.usesthesafevoltagetheweakelectricityboardtosubstitutethestrongelectricityboard,enhancedthesecurity;Throughtheelectriccurrentandtheleakageelectriccurrentexaminationtotheimportantmedicalequipment,promptlyreportedinthebreakdownsituation,strengthenedthemedicalequipmentreliabilityandsecurity.Functions:
1.Lightcontrolofwardandoutpatientservicebuilding
2.Electricalwindowcurtainandvisorvolumecurtaincontrolofwardandoutpatientservicebuilding
3.Airconditioner,heatsupandtheairblowerplatetubecontrolofwardandoutpatientservicebuilding
4.Illuminationandthelightadjustingoftheoperatingroomandthetreatmentroom
5.Hospitalwardringingsystem
6.AVdevicecontrolofacademicexchangecenterandconferenceroom
7.Illuminationelectricalpowerdistributionsystemandfirelinkage
8.Linkagehospitalautomationofficesystem,torealizetohavenopaperwork
9.All
T-bussystemintelligentcontrollers
circuitbreakerofOutpatientserviceandin-patientdepartmentandimportantmedicalequipmentcircuitbreakerconditionsurveillance
10.Centralismmonitorandcontroloftheoutpatientserviceandthehospitalwardtoachievethenon-boardcontrolinthepublicregionControlledareaandcontrolcontent:
1.hospitalward
Controloflight,electriccurtain,fancoilunit,ringingsystem,thesocketofmicrowaveovenandsoon,ultravioletraysterilizationlamp
2.Outpatientservicehall
Controloflight,visorvolumecurtain,fancoilunit
3.Thedepartmentsofthetreatment,theinspection,thesurgery,thediagnosis,rescueandsoon.
Controloflight,electriccurtain,fancoilunit
4.Commonaisle,elevatorhall
Controloflight,undergroundlampcontrol
5.Academicexchangecenter,reporthall
Controloflight,AVequipment,windowelectriccurtain,theatercurtain;
6.Extensivelighting,botanicalgardenillumination
Controloflight
7.CentercontrolcomputerSolutions:
1.Hospitalward
*Installs8path2.4GHz
T-bussystemintelligentcontrollersbesidethebed,controlsthelightswitchandadjuststhelightintheguestroom,controlstheopeningandclosingoftheelectriccurtain,maycarryonthemasterswitchcontroltothehospitalwardlight,maycontrolthebathroomlight,andmaysetthedoctorsclinicscene,therestscene,thetelevisionwatchingscene.
*TheangleofthehospitalwardelectricallyoperatedbedcanbeadjustedthroughtheT-bussystemintelligentcontrollersandtheremotecontrol,facilitatesthedoctorsclinicandthepatientdines,reads;
*Guardianshipringingsystem.Whenthepatientneedstheguardianshipthepatient’sfeelingisnotgood,maypressthecallbuttonortheremotecontrolnearbythebed,theon-dutynursemayrushtothehospitalwardtocarryonprocessingimmediately;
*ThecentercontrolcomputerinEachfloornursestandcanimplementthecommoncontroltovariousillumination,thecurtainandtheair-conditionersystemathospitalwardsincorrespondingfloor,andthecomputerofeachnursestandcandemonstratetheindoortemperatureineachhospitalward,simultaneouslymayestablishthemaximumandminimumtemperature,providesthehumannatureservice;
*Thehospitalwardcorridorilluminationmayautomaticallyopenbycoordinatingwiththelightsensorandthetimers,whenthedegreeofilluminationrequestisverylowatthedeepernight,
shutsdownpartialilluminationslight,thefootlightautomaticallyopens.
*Thenursestationmayrealizecentralismmonitoringtothesocketsofvariousmedicalequipmentssuchasbreathmachineandsoonintheward.
*Installsaintelligentswitchwithatemperaturecontrolboardattheentrance,carriesontheautomaticconstanttemperaturecontroltothefancoilunitofthehospitalward,maydemonstratetheindoortemperature,simultaneouslymaycarryonthecontroltothelightandthecurtain.
*Installsintelligenceswitchatthebathroomentrance,maycarryonthecontroltothebathroomlightandtheventilatingfan
*Ifwithintelligentdoorlocksystemlinkage,mayrealizethedifferentopeninggatepatternbetweenthedoctorandtheserviceperson,namedtheclinicpatternandthesweepsclearpattern.
*AfterthepatientCheck-in,automaticallyadjuststhelightandtheelectriccurtainatthecorrespondingwardtoin-patientpattern,adjuststheairconditionertemperaturetocomfortabletemperature.Enablesthepatienttohavethehomefeelingandenhancesthehospitalservicescale.
*Afterthepatientleft,automaticallyadjuststhelightandtheelectriccurtainatthecorrespondingwardtoclosurepattern,mayautomaticallyrestorethewardhypothesistemperaturetotheconditionwhichtacitlyapproves.
*Afterthepatientgoestosleepatnight,T-bustemperaturecontrolsboardautomaticallychangestoenergyconservationpattern.Accordingtothestatistics,thehypothesistemperatureelevates1(whenrefrigeration)orreduces1(whenheatsup)everytime,mayconserveenergy6%
*Thecentercontrolroommaydemonstratetheactualtemperatureandthehypothesistemperatureofeachhospitalward.Alsomaysetthemaximumandminimumtemperature.Simultaneouslythehospitalwardtemperaturecontrolalsomayconnectwiththewindowlinkage,afterthewindowisturnedon,automaticallyclosestheairconditionertorealizeenergyconservationfully.
*T-bustemperaturecontrolsboardcanautomaticallycontrolFancoilunit.Whentheindoortemperatureapproachesthehypothesistemperature,automaticallyadjustswindspeedfromhightolow,makestheindoortemperaturetomaintainaroundthehypothesistemperature,tosaveenergyanditisverycomfortable.
*Whensummersunlightisintense,automaticallyshut-offwardcurtain,preventedthewardtemperaturetobeexcessivelyhigh,achievestheenergyconservationpurpose.2.Outpatientservicehall
*Automaticallycontroldegreeofilluminationoftheoutpatienthallthroughlitsensoratdaytime.Whenthenaturallightisintense,closespartiallights,otherwise,thenopensthecertainlight,makestheoutpatienthalltomaintaintheconstantdegreeofillumination.Simultaneouslymayconserveenergy.
*Atnightmayactdifferentdegreeofilluminationaccordingtothepatientcurrentcapacity.
*Controlsthevisorvolumecurtainofthehallthroughthelightsensor.Whenthesummerlightisintense,automaticallylaysdownthevisorvolumecurtain,inordertoconservesenergy.
*Maycontrolthelight,thevisorvolumecurtainoftheoutpatienthallthroughthecentercontrolroomcomputer.3.Thetreatmentoftheinspection,thesurgery,thediagnosis,therescueandsoon
*Theoperatingroom,therequirementofgeneraldegreeofilluminationisnotlowerthan1000Lux.Theshadowlesslamptookasthelocallighting,shouldachieveabove20000Luxinthesurgerytable30cmscope.MayadjustthelighttotheauxiliarylightsourcethroughtheT-bussystemintelligentcontrollersboardortheremotecontrol,mayadjuststhelightscopefrom0%to100%.
Accordingtodifferentoperatingroomilluminationdegree,speciallythelocallightingdegreeofilluminationisdifferent,Mayadjustthelightsourcedegreeofilluminationtocarryonthepre-establishment.
Throughilluminationdegreesensorestablishedintheoperatingroom,carryonthepreciseadjustmentofilluminationdegreetosomeworksurface.
*Regardsthefunctionalcheckingroom(mainlyrefertoophthalmologydepartment),itsrequirementofilluminationdegreereachesashighas7500Lux.ThroughtheT-bussystemintelligentcontrollerboardandtheremotecontrol,mayadjustthelightscopeaccordingtothehospitalilluminationstandardrequesttothe50Luxscope;
Inregardsthemirrorinspectionroom,Xperspectiveroom,theophthalmologydepartmentdarkroomandsoonthedegreeofilluminationisinthe50-100Luxscope,mayadjustthelightto0Lux.throughtheT-bussystemintelligentcontrollerboardandtheremotecontrol.
*stallstheelectriccurrentandtheleakageelectriccurrentexaminationmoduleregardingthebelowimportantadvancedequipment,likespiralCT,coloredDopplerBultramachine,theentireautomaticbloodcongealsanalyzer,theentireautomaticchemistrylightingimmunityanalyzer,24hoursdynamicelectroencephalogrammeter,straightverticalD5-3machine,thecentralguardianshipsystemandthebreathmachineandsoon.
Throughtheelectriccurrentandtheleakageelectriccurrentexaminationtotheequipment,earlydiscoveredequipmenthiddendanger,reportedtotherelativemaintenancedepartmentbeforetheequipmentfailureatanearliertime,reducedthelifeandpropertylosecausedbytheequipmentfailure,reducedthemaintenanceworkload,strengthenedthemedicalequipmentsecurityandreliability.
*thesurveillanceofthemedicalequipmentpowersupplyandcircuitbreakercondition,anyartificialorthebreakdowntripswillpromptlyfeedbackthesystemandrecognizeit,noticedtotheserviceman.
Afterthereservepowersourcestarts,thesystemshouldprovidetheurgentlightcontrolfunction,onlyprovidesthepowersourcetotheurgentlightreturnrouteinandprohibitsnormallightreturnroutecontrol.
Intheoutpatientserviceconsultingroom,thetreatmentroom,therescueroom,thesmalloperatingroom,thegynecologyandobstetricsdepartment,infectward,thetumorward,theburnward,thenewbornroom,thecardiovascularroomandsoonareequippedwiththestationaryinstallmentultravioletraysterilizationlamp,maysupposetheindependentcontrollingswitch,andusesthetimertocarryonthetimedcontrol.4.commonaisle,elevatorhall
*Selectsensorandtimesettingcoordinatestocontrolthelight,openscompletelyorthemajorityoflightswhendaytimepersoncurrentcapacitygreat,afterthemidnightclosesthemajorityoflights,simultaneouslystartsthehumanbodysensor,whensomepeopleappear,opensthecorrespondingregionlight,conservesenergyinmaximumway.
*Whennaturesunshineisgood,doesnotturnonthelighttosavetheenergy;Whencloudydayordarkness,turnonthelightaccordingtothepersonnelneeds;
*Mayconnectwiththefirelinkage,whenthefireappearing,mayrealizethelampluminousintensitytocutorthestrongpointfunction,startemergencylightingcontrol.5.Academicexchangecenter,reporthall,multi-purposehall
*Installs2.4GHzT-bussystemintelligentcontrollerintheconferenceroom,T-bussystemintelligentcontrollerhasthelightscenecontrolfunction,temperaturecontrolandremotecontrolfunctions;
*Installsthehumanbodysensorintheconferenceroom,mayachievesomebodytoturnonandturnoffthelighttheairconditioner,nobodytoturnonandturnoffthelighttheairconditioner,inordertoavoidwasteifforgettingtoclose;
*Installsthetouchscreencomputerinthereportpanel,throughthegraphicalinterfaceofthetouchscreentocarryoneachkindoflightsceneandtheAVscenecontrol:Conferencescene,lecturescene,restscene,showingsceneandsoon;Showingscenedescription:Presses“onekeyscene"oftheremotecontrol”,thelightadjustsintheroom,theprojectiontheatercurtainlaysdown,thecurtainlaysdown,theprojectingapparatusopens,themeritputs/DVDopens,allininstantaneouscompletes.
*InstallstheT-busintelligenceswitch,thisboardhasthelightscenecontrolfunction,simultaneouslyhaslocking(toguardagainstwrongoperation)function.6.Extensivelighting,botanicalgardenillumination
*Thehotelextensivelightingandthebotanicalgardenilluminationmayselectthemethodwhichthelitsensorandtimesettingcoordinatestocarryontheautomaticcontrol.
*Whenthenaturallitchangesdark,thelightsensorautomaticallyopensthemajorityofextensivelightingandthegardenillumination,whenatnightforexample12o'clockPM,setstimeandthepartialextensivelightingandthebotanicalgardenilluminationcloses,leavesfewbaselightingsonly,thelightsensorcanturnofftheleftlightswhenthedayiscoming.Thewholeprocessisautomaticandenergyconservation.7.Centercontrolcomputer
*Throughthecomputergraphsurfacemaycarryonthecentralismmonitoringandcontroltotheeachequipmentsuchasvariousregionlight,airconditioners,electriccurtain,HVAC,AVandsoon.
*Maycarryontheeventrecord,inordertoprocesses;
*whenanychapteroflightappearsthebreakdown,mayinformtheadministratorimmediately.
*Throughthecomputercarryontheaccumulationoftheusingtimesofexudelight,commonaisle,elevatorhall,greathallandsoon,inordertopromptlyservicesthereplacement;
*Maydemonstrateeachregiontemperature,maysimultaneouslysetthemaximumandminimumtemperatureofvariousregion,avoidsenergywasting.翻譯:2.4GHzT-busEIB智能化醫(yī)院控制系統(tǒng)現(xiàn)代化醫(yī)院的建筑功能復(fù)雜,醫(yī)療設(shè)備精密,對環(huán)境標準要求高,用2.4GHzT-bus智能控制系統(tǒng)能夠與醫(yī)院的建筑環(huán)境相結(jié)合。通過數(shù)字化節(jié)能醫(yī)療服務(wù)環(huán)境的建立,可以提高醫(yī)院的管理水平,提高醫(yī)務(wù)人員的工作效率,節(jié)省醫(yī)院的運營成本。T-bus智能環(huán)境控制系統(tǒng)能通過控制各種末端電氣設(shè)備(比如燈具、電動窗簾、空調(diào)、醫(yī)療設(shè)備等)實現(xiàn)對照明環(huán)境、光照環(huán)境、溫度環(huán)境和醫(yī)療設(shè)備運行和醫(yī)院許多部門,如門診部、住院部等的維護的最優(yōu)控制。目的:統(tǒng)一化管理、控制和保護醫(yī)院照明、空調(diào)和醫(yī)療設(shè)備提高醫(yī)院的服務(wù)等級,為醫(yī)務(wù)人員和病人提供舒適的環(huán)境節(jié)能、減少醫(yī)院運行成本用安全電壓的弱電面板替代強電面板,提高安全性能;通過對重要醫(yī)療設(shè)備電流和漏電電流的檢測,在故障情況下及時報警,增強醫(yī)療設(shè)備的可靠性和安全性功能:病房和門診部燈光控制病房和門診部的電動窗簾和遮陽簾的控制病房和門診部的空調(diào),地?zé)岷凸娘L(fēng)機盤管控制手術(shù)室和治療室照明調(diào)節(jié)病房呼叫系統(tǒng)學(xué)術(shù)交流中心和會議室的視聽設(shè)備控制照明配電系統(tǒng)和消防聯(lián)動醫(yī)院自動辦公系統(tǒng),實現(xiàn)無紙化辦公T-bus系統(tǒng)對門診部和住院部所有配電箱內(nèi)斷路器以及重要醫(yī)療設(shè)備斷路器的狀態(tài)智能監(jiān)控集中監(jiān)控門診部和病房,實現(xiàn)公共區(qū)域的無面板控制控制區(qū)域和控制內(nèi)容:病房控制燈光、電動窗簾、通風(fēng)盤管裝置、呼叫系統(tǒng)、微波爐的插座和紫外線滅菌燈等門診大廳控制燈光,遮陽簾和通風(fēng)盤管裝置治療、檢查、手術(shù)、診斷和救護等部門控制燈光,電動窗簾和通風(fēng)盤管裝置公共通道和電梯間控制燈光和地?zé)艨刂茖W(xué)術(shù)交流中心和匯報廳控制燈光、視聽設(shè)備、電動窗簾、幕布泛光和園林照明控制燈光中控計算機解決方案:醫(yī)院病房*在病床后安裝帶場景功能的8路徑2.4GHz
T-bus系統(tǒng)智能控制器,控制照明開關(guān)調(diào)節(jié)客房照明,控制電動窗簾的開合,許可總開關(guān)控制醫(yī)院病房光照,可以控制衛(wèi)生間燈光,還可設(shè)置醫(yī)生診療場景,休息場景和電視觀看場景;*電動病床可以通過T-bus系統(tǒng)控制器和遙控器調(diào)整坐立角度,方便醫(yī)生診治和病人就餐和閱讀;*監(jiān)護呼叫系統(tǒng),當病人感覺不適需要護理時可以按下床邊的呼叫按鈕或者遙控器,值班護士就會立刻趕到病房進行處理;*在每一層護士站內(nèi)的中控電腦能夠執(zhí)行同一樓層的不同照明、窗簾、空調(diào)系統(tǒng)的集中控制,還能顯示每一病房室內(nèi)溫度,同時可以設(shè)立最高和最低溫度,為病人提供人性化服務(wù);*病房走廊照明可以通過光敏傳感器和定時器打開,當深夜對照明要求較低時,部分照明燈光關(guān)閉,腳燈自動打開;*護士站可以集中控制在病房內(nèi)的各種醫(yī)療設(shè)備插座,比如呼吸機等;*在入口安裝一個帶溫度控制版的智能開關(guān),對通風(fēng)盤管裝置進行自動恒溫控制,顯示室內(nèi)溫度,同時還能對燈光和窗簾進行控制;*在衛(wèi)生間入口安裝一個帶溫控面板的智能開關(guān),可以對衛(wèi)生間燈光和通風(fēng)機進行控制;*如與智能門鎖系統(tǒng)聯(lián)動,就可以實現(xiàn)不同的醫(yī)生和服務(wù)人員的開門模式,即會診模式和垃圾清掃模式;*在病人登記之后,可以自動地調(diào)整病房的燈光和窗簾,調(diào)整空調(diào)到住院模式。使病人有在家的感覺,并提高醫(yī)院的服務(wù)等級;*當病人出院后,可自動地調(diào)整病房的燈光和窗簾到關(guān)閉模式,并可自動將病房設(shè)定溫度恢復(fù)到默認狀態(tài);*當病人晚上睡覺后,T-bus溫度控制板自動地調(diào)整到節(jié)能模式。據(jù)數(shù)據(jù)表明,假定溫度每次升高1度(制冷時)或降低1度(加熱時),就可以節(jié)能6%;*中央控制室可以顯示每一間病房的實際溫度和設(shè)定溫度,也可以設(shè)定最高和最低溫度。同時病房溫度控制也可與窗聯(lián)動,當窗戶打開后,自動關(guān)閉空調(diào)以實現(xiàn)節(jié)能最大化;*T-bus溫度控制板能自動控制通風(fēng)盤管裝置。當室內(nèi)溫度接近設(shè)定溫度時,自動調(diào)整風(fēng)速的高低,讓室內(nèi)溫度保持在設(shè)定溫度附近,以便節(jié)能,并很
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 四年級任課老師工作總結(jié)
- 畢業(yè)演講稿五篇
- 前臺的實習(xí)報告15篇
- 初一書信作文600字范文【5篇】
- 房地產(chǎn)銷售實習(xí)報告五篇
- xx省天然氣管網(wǎng)項目可行性研究報告
- 中秋活動方案范文四篇
- 城市停車場項目招商引資報告
- 四川省宜賓市(2024年-2025年小學(xué)六年級語文)部編版競賽題(下學(xué)期)試卷及答案
- 四川省宜賓市(2024年-2025年小學(xué)六年級語文)統(tǒng)編版能力評測(上學(xué)期)試卷及答案
- 舊樓加裝電梯計算書(結(jié)構(gòu)驗算)
- 固定資產(chǎn)情況表
- 超聲引導(dǎo)下腰方肌阻滯PPT
- 主蒸汽及再熱熱段管件技術(shù)協(xié)議-終版
- DB23∕T 2771-2020 黑龍江省城鎮(zhèn)供熱經(jīng)營服務(wù)標準
- (完整PPT)半導(dǎo)體物理與器件物理課件
- 王守仁英國文學(xué)選讀課后答案
- 奧星-計算機化系統(tǒng)驗證要點分析與校準管理
- 新浙美版三年級上冊美術(shù)教案
- 中國國際商會入會申請表
- 裂隙燈顯微鏡的原理
評論
0/150
提交評論