1、CORROSION AND PRESTRESSED CONCRETE BRIDGESAdrian T. Ciolko, P.E.1腐蝕和預(yù)應(yīng)力混凝土橋梁AbstractThe impact on bridge reliability, of prestressing steel deterioration and tendonrupture created by corrosion me

2、chanisms, is much more critical and rapid thanthat of any other component of a prestressed concrete bridge.Additionally,deterioration of embedded prestressing reinforcement in these str

3、uctures may notnecessarily be made visible through manifestation of external distress in theConcrete.摘要腐蝕機(jī)制引起預(yù)應(yīng)力鋼筋的惡化和斷裂,進(jìn)而對(duì)橋梁的可靠性產(chǎn)生影響,這比對(duì)預(yù)應(yīng)力混凝土橋的其他部分的影響更加嚴(yán)重,也更加迅速。 此外,在這些結(jié)構(gòu)中,有粘結(jié)預(yù)應(yīng)力鋼筋的惡化也不必要通過(guò)混凝土外部糟糕的狀況表現(xiàn)出來(lái)。Initiating mechanisms a

4、nd particular forms of corrosion affectingprestressed concrete structures are described based on the authors experience.These degradation mechanisms include:Chlorides and CorrosionConcrete Carbonation

5、 EffectsInfluence of Concrete CrackingElectrochemical (Macrocell) and Pitting CorrosionStress Corrosion Cracking and Steel EmbrittlementFretting CorrosionCorrosion and Fatigue關(guān)于腐蝕影響預(yù)應(yīng)力混凝土結(jié)構(gòu)的最初機(jī)制和特定形式的描述是基于作者的經(jīng)驗(yàn)。這些退化機(jī)制包括:

6、 氯化物和腐蝕 混凝土碳化影響 混凝土裂縫的影響 電化學(xué) (小區(qū)) 和孔蝕 應(yīng)力腐蝕開裂和鋼的脆斷 微動(dòng)腐蝕 腐蝕和疲勞Recently, prestressed, post-tensioned concrete structures have beenthought to be threatened by certain premature performance impairmentsworldwide, predominately 

7、;when defects were present.These problems maycontinue to manifest themselves. Therefore, corrosion preventative methods andneed for scrutiny during construction and maintenance needs will be

8、 described.For existing structures experiencing evidence of premature distress, the authordiscusses case-study based investigative techniques and available rehabilitationStrategies.最近,世界各地的預(yù)應(yīng)力、 后張法預(yù)應(yīng)力混凝土結(jié)構(gòu)已經(jīng)被認(rèn)為受到某些早

9、期性能破壞的威脅,尤其是已經(jīng)存在的缺陷。這些問(wèn)題可能繼續(xù)危害結(jié)構(gòu)。因此,我將對(duì)預(yù)防腐蝕的方法和施工與維護(hù)期間的檢測(cè)進(jìn)行介紹。對(duì)于遭受早期破壞的現(xiàn)有結(jié)構(gòu),作者討論案例研究是基于探測(cè)技術(shù)和有效的修復(fù)手段。1  Vice President, Construction Technology Laboratories, Inc., 5400 Old Orchard Road, Skokie,IL 60077.1Copyright ASCE 2005Str

10、uctures 2005Structures Congress 2005IntroductionThe first prestressed concrete bridge in the US was constructed in 1950; the paceof acceptance for this construction technology accelerated

11、60;rapidly; most allconcrete bridge superstructures in existence today were built in that fashion.Assuring success in new construction and extending service life of prestressedand post-

12、 tensioned concrete bridges requires attentiveness to the distinctivecharacteristics and behaviors inherent to this particular construction technology.介紹美國(guó)的第一個(gè)預(yù)應(yīng)力混凝土橋建于1950年;接受這種施工技術(shù)的步伐迅速加快;在這個(gè)時(shí)尚潮流中建造了當(dāng)今大多數(shù)的混凝土橋梁上部結(jié)構(gòu)。確保成

13、功應(yīng)用于新型結(jié)構(gòu)和延長(zhǎng)預(yù)應(yīng)力和后張法預(yù)應(yīng)力混凝土橋梁的使用壽命需要專注于這種特殊施工技術(shù)的顯著特點(diǎn)和固有特征。This paper discusses considerations necessary for achieving the potentiallow maintenance service life these bridges can offer. These observations arederive

14、d from the authors experience in investigating and evaluating prestressed,post-tensioned concrete bridges, and developing investigative and rehabilitationsolutions at the CTL Structural Engineeri

15、ng Laboratory since 1988. While thedurability of prestressed concrete can be influenced by behaviors of both theconcrete and reinforcement, recent construction trends and post tens

16、ionedconcrete bridge performance observations have focused more attention onpreserving the condition of prestressing steel. Consequences of prestressing steeldeterioration are most serious. Aware

17、ness of these features is a key element toconstruction of long lasting prestressed bridges and extending life of older,serviceable structures.本文討論了實(shí)現(xiàn)這些橋梁潛在的低維護(hù)使用壽命所需的考慮。自1988 年以來(lái),作者在 CTL 結(jié)構(gòu)工程實(shí)驗(yàn)室調(diào)查和評(píng)估預(yù)應(yīng)力、后張

18、法預(yù)應(yīng)力混凝土橋梁、開發(fā)檢測(cè)和加固解決方案,這些觀測(cè)結(jié)論就源于這期間的經(jīng)驗(yàn)?;炷梁弯摻顑烧叩男阅芏加绊戭A(yù)應(yīng)力混凝土的耐久性,但是當(dāng)近的建設(shè)趨勢(shì)和后張預(yù)應(yīng)力混凝土橋梁性能檢測(cè)都更多地集中于預(yù)應(yīng)力鋼筋的維護(hù)。預(yù)應(yīng)力鋼筋惡化的后果是最嚴(yán)重的。對(duì)這些特點(diǎn)的認(rèn)識(shí)是對(duì)建設(shè)持久的預(yù)應(yīng)力橋梁和延長(zhǎng)舊的可用結(jié)構(gòu)壽命的一個(gè)關(guān)鍵因素。Function of Prestressing Reinforcement in Bridge Design and ConstructionMost concrete highwa

19、y bridges are comprised of prestressed concrete in twopredominant fabrication/construction categories; namely pretensioned and post-tensioned, with more than 90% representing pretensioned. The

20、60;geometric crosssections and design/construction procedures used represent a broad range ofpossible structural design configurations, both precast and cast-in-place; theinterested reader is enc

21、ouraged to obtain information from organizations such asthe Prestressed/Precast Concrete Institute, the Post Tensioning Institute and theAmerican Segmental Bridge Institute for in-depth desi

22、gn and constructionguidance for this technology, since exploring its complexity is beyond the scopeof this paper.預(yù)應(yīng)力加固橋梁設(shè)計(jì)和施工中的作用最具體的公路橋梁是由組成的預(yù)應(yīng)力混凝土在兩個(gè)主要制造/建筑類別 ;即先張法和后張法,有 90%以上表示先張法預(yù)應(yīng)力。幾何截面和使用的設(shè)計(jì)/施工程序代表的范圍廣泛的可能結(jié)構(gòu)設(shè)計(jì)配置、 預(yù)制和強(qiáng)制

23、轉(zhuǎn)換的地方 ;有興趣的讀者應(yīng)該鼓勵(lì)從預(yù)應(yīng)力/預(yù)制混凝土研究所、 后張法研究所和美國(guó)節(jié)段橋梁研究所深入設(shè)計(jì)和施工指導(dǎo)對(duì)這一技術(shù),等組織獲得的信息,因?yàn)樘剿魉膹?fù)雜性是超出了本文的范圍。Prestressed (less commonly known as pretensioned) concrete is made bystressing the reinforcement between fixed bulkheads and cast

24、ing concrete aroundthe steel elements. Following concrete curing, the steel strand is released at thebulkhead, transferring compressive stress and added stiffness into the concrete.Most

25、 all pretensioned concrete bridge components are precast in specializedfabrication yards, then shipped and erected on-site.Post-tensioned concrete for bridges predominately contains multiplestran

26、d or bar tendons.Tendons are stressed against built-in multi-pointanchorages; and tendon forces are internally resisted by the concrete mass incompression.Tendons are installed in sheat

27、hing or ducts preplaced in theformwork prior to casting. Tensile forces in stressed tendons are transferred toconcrete through specialized anchorage hardware, creating compression in

28、60;theconcrete, making the structural element stiffer.In bridges, both bonded andunbonded tendon construction is used.In bonded tendon construction,2Copyright ASCE 2005Structures 2005Structures Congre

29、ss 2005cementitious grout is injected into the ducts after stressing; protecting againstcorrosion and enhancing the strength capacity of the bridge element, since groutbonds the te

30、nsile element to the surrounding concrete mass along its length.Bonded tendons are positioned within the thickness of girder webs and flangesUnbonded tendon construction is sometim

31、es used in concrete bridges whenexternal tendons are chosen in design; these are positioned outside the mass of theconcrete girder elements, although these are nearly always&#

32、160;incorporated within theinteriors of cellular construction. Unbonded tendons are also grouted, principallyfor corrosion protectionCommon among these bridge components is the role of the&#

33、160;prestressingreinforcement, which can take the form of cold-drawn high strength wire, or wirehelically wound to form 7-wire strand, and rolled high strength threaded bars.Prestressin

34、g strand for bridge construction is presently supplied with a tensilestrength of 1860 MPa, and bar reinforcement in 1030 to 1100 Mpa tensilestrength.Prestressing wire (parallel

35、0;wire systems) has also been used forprestressed bridges, though not in this country for more than two decades.In bridges, the prestressing reinforcement element provides the 

36、;concretestructure a means for counteracting tensile stress resulting from service loads, andprovides the needed capacity for the strength limit state. As such, the prestressingreinforc

37、ement must reliably and continuously sustain, over the life of thestructure, a minimum stress level on the order of 60% of its nominal strength. Inthe realm of engin

38、eering design, this demand on material performance is verysubstantial.Consequently, the prestressing reinforcement's quality and its protectionagainst aging and deterioration process are para

39、mount to attaining functional andsafety requirements of a concrete bridge structure.Design of prestressedmembers provides directly for several forms of durability measures such as dense

40、concrete cover, corrosion mitigating grout systems, and innovative, proprietaryfull length corrosion barriers integrated with anchorage systems for post-tensioned structures.Additionally, structural d

41、etails and standards have beendeveloped and introduced by AASHTO and various industry organizations tomanage effects of prestressing reinforcement's heightened susceptibility to knownaging

42、60;mechanisms such as fatigue, fretting, and time dependent, inelastic changesin concrete structure components.Bridge management strategy presently relies on fixed-interval inspectionsand computation&

43、#160;of bridge load ratings. Unfortunately, the condition inspectionsare comprised exclusively of visual observation of the structural features visibleto the unaided eye, and few widely

44、 accepted practical means exist forquantitatively measuring condition of the prestressing and for integrating resultsof such measurements into the strength and serviceability rating com

45、putations.The most recent 5-year history of post-tensioned bridge construction hasevolved significant changes in perception of these bridges performance.Aging and Degradation Mechanisms Influence

46、 PracticesThe historic performance record of more than 100,000 prestressed concrete bridgestructures in the US is generally considered satisfactory; however some corrosion3Copyright ASCE

47、0;2005Structures 2005Structures Congress 2005of prestressing steel had been reported in a minority of structures.FHWA-sponsored surveys in 1987 and 1992 of 20 major in-service structure

48、srepresentative of the prestressed concrete component of the nation's highwayinfrastructure supported and highlighted need for design for serviceability.Findingsofvisualinspection/corrosionsensing/materialsstudi

49、esbyNovokshchenov and Whiting et al. for pretensioned and post-tensionedsuperstructures of various configurations throughout the full range of USenvironmental exposures, found no evidence of

50、 serious prestressing reinforcementcorrosion or other systemic degradation. These studies and other similar findingsof the highway transportation community have led to recommendations relate

51、dprimarily to minimization of the number of deck joints, more durable, protectiveconcretes and coatings for anchorage components, improved deck and jointdrainage systems to redirect

52、0;passage of aggressive solutions from corrosion-susceptible components near girder ends, and implementation of more effectivedeck joint maintenance programs.Some prestressed concrete structures 

53、have displayed troublesomepremature performance impairment trends worldwide, discriminating thisstructural concept from others when one considers development of a rationale forassessing and maint

54、aining bridge reliability and utility beyond the 50-year agemilestone. Szilard, in a 1969 survey performed on behalf of FIP, noted thatcorrosion of prestressing reinforcement was&#

55、160;the predominant form of unexpecteddamage to structures, whether accidental or deterioration/aging based. In 1971,the Australian Water Resources Council published results of a wide-rangin

56、g studyof the performance of prestressed concrete structures worldwide intended toassess the performance of Australian prestressed structures and compare it withthat of structures elsew

57、here.The work was prompted by premature multiplefailures of prestressed, wire-wound pipelines and tanks, and helped establishimproved specification for prestressing wire and concrete/mortar 

58、and otherprotective coatings. Citing the criticality of corrosion protection for prestressedconcrete pressure vessels for nuclear reactor containments, Griess and Nausstudied corrosion behavior&#

59、160;of high-strength prestressing steels in 1978, reviewingseveral incidents of prestressing steel failures in nuclear pressure vassels in theU.S., France, and United Kingdom.Schupack conduc

60、ted a performance survey covering the time period of1950 to 1977, concluding that the noted failure incidence rate of 200 tendons outof an estimated worldwide prestressing

61、0;steel consumption of 30,000,000 tons wasnegligible. However, an NCHRP study performed by a forensic engineering firmin 1982 reported that 50 structures with tendon corrosion were

62、 noted in the timeperiod between 1978 and 1982. Ten of these reportedly displayed brittle fracturessuggestive of environmental cracking phenomena. In 1992, Ciolko summarizedstructural&#

63、160;evaluation and failure analysis data from U.S. prestressed concretepipeline failures, estimating based on industry and water utility records that morethan 60 such pressure pipelines

64、 had failed in the US, principally due toaccelerated corrosion of poorly protected prestressing wire. Common to all as afactor contributing to performance impairment was the&#

65、160;heightened susceptibilityof prestressing wire to accelerated corrosion phenomena.4Copyright ASCE 2005Structures 2005Structures Congress 2005In 1992, Podolny warned designers of the danger of 

66、complacencyresulting from reliance on the some of the favorable conclusions from earlysurveys and reports of the condition of prestressed structures. He concluded thatalthough the 

67、population of prestressed structures has greatly increased in the lasttwo decades, it was only recently that we have begun to understand the role thatenvironment and the 

68、many forms of corrosion have on reliability of prestressingreinforcement.In 1998, Poston and Wouters reported in an NCHRP study of durability ofprecast segmental (post-tensioned) bridge

69、s, that no evidence of corrosion or otherdurability problems with these bridges existed, cautioning however, that thegathered information was based principally on visual inspections.

70、60;The study citedthat lack of improved nondestructive evaluation options hinders evaluation ofthese structures.Podolnys caution regarding complacency was warranted, as werePostons concerns for&#

71、160;lack of diagnostic nondestructive tools which would haveprovided a more reliable means for judging condition of post tensioned structures.In 1999, corrosion-related failure of an

72、60;external (unbonded) posttensioning tendon in Florida DOTs 20-year old Niles Channel Bridge focusedattention on post-tensioned bridges. Three other Florida bridges including theMid-Bay Bri

73、dge in Destin, Sunshine Skyway (St. Petersburg), and I-75/I595Sawgrass Interchange in Broward County were later investigated. Investigationsof these structures highlighted the critical role&

74、#160;that tendon grouting andcomplementary corrosion barriers take in successful construction. The root causesof reinforcement deterioration in these bridges were identified as groutingprocedure&

75、#160;ineffectiveness for controlling entrapment of bleed water in tendons,and poor tendon duct detailing creating access for aggressive solutions. Theseincidents prompted rigorous review of&

76、#160;the durability issues related to corrosion ofpost-tensioned concrete structures.Corrosion  Mechanisms and ThreatsCorrosion is defined as the degradation of a metals integrity and s

77、trength byinteraction with its environment. Because the metals used in construction arerefined from their naturally-occurring oxides, the refined metal is lessthermodynamically stable than&#

78、160;its oxide.When corrosion occurs, the refined metals structure reverts to itsnaturally-occurring state through an electrochemical reaction.Initiation andsustenance of the reaction require exis

79、tence of an electrolytic cell. Each corrosioncell requires three elements;an anode ( the region of metal which corrodes, or reverts to an oxide),an electrolyte (a corrosion-en

80、abling medium or environment which provides apath or environment for electrons or current to flow, which may be inherentlyaggressive or benign), anda cathode ( the location

81、60;where electrons are consumed or absorbed, and themetal is protected from corrosion).5Copyright ASCE 2005Structures 2005Structures Congress 2005Metals in concrete, including mild steel rei

82、nforcement, prestressing steelencased in high quality concrete (pretensioned), and prestressing steel in fullygrouted post-tensioning ducts are known to be resistant to corrosion due to

83、 thebeneficial effects of the highly alkaline environment that cementitious materialscan provide.When these alkaline conditions are effectively sustained in an unbroken,continuous state, the

84、 metals surface, which would otherwise be unstablethermodynamically, is known to be passivated, or protected by a thin iron oxidefilm.Design of concrete structures for serviceabili

85、ty is predicated on thisprinciple, and more than a hundred thousand US highway structures haveperformed adequately based on this design philosophy.However, if the highly alkaline&#

86、160;environment provided by concrete orcementitious grout is absent (at voids and other defects); wherever the passivationis interrupted or breached; or wherever the passivating environ

87、ment is alteredchemically, corrosion will occur.It is very important to note in any discussion on this subject matter thatcorrosion is never uniformly distributed. That kind o

88、f deterioration would ideallyrequire that each atom on the metals surface be equally sensitive to the corrosionmedium(electrolyte) and that the medium have uniform access to a

89、ll surfaceatoms.The various forms and types of corrosion observed in reinforced andprestressed concrete are therefore manifestations of the non-uniformities inherentin materials, manufacturing

90、60;defects, alteration of the concretes chemistry, andmechanical damage arising in manufacture, construction or during service.Initiating mechanisms and particular forms of corrosion affecting

91、60;prestressedconcrete structures are described in the following sections; consideration of eachas an influence on optimal service life of a prestressed concrete bridge is neededin design and specification, c

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

最新文檔

評(píng)論

0/150

提交評(píng)論