![暫態(tài)錄波型故障指示器技術(shù)條件與檢測規(guī)范20160825 翻譯件20161018_第1頁](http://file2.renrendoc.com/fileroot_temp3/2021-10/19/e0e80b93-53a5-4717-bc32-879a9575932c/e0e80b93-53a5-4717-bc32-879a9575932c1.gif)
![暫態(tài)錄波型故障指示器技術(shù)條件與檢測規(guī)范20160825 翻譯件20161018_第2頁](http://file2.renrendoc.com/fileroot_temp3/2021-10/19/e0e80b93-53a5-4717-bc32-879a9575932c/e0e80b93-53a5-4717-bc32-879a9575932c2.gif)
![暫態(tài)錄波型故障指示器技術(shù)條件與檢測規(guī)范20160825 翻譯件20161018_第3頁](http://file2.renrendoc.com/fileroot_temp3/2021-10/19/e0e80b93-53a5-4717-bc32-879a9575932c/e0e80b93-53a5-4717-bc32-879a9575932c3.gif)
![暫態(tài)錄波型故障指示器技術(shù)條件與檢測規(guī)范20160825 翻譯件20161018_第4頁](http://file2.renrendoc.com/fileroot_temp3/2021-10/19/e0e80b93-53a5-4717-bc32-879a9575932c/e0e80b93-53a5-4717-bc32-879a9575932c4.gif)
![暫態(tài)錄波型故障指示器技術(shù)條件與檢測規(guī)范20160825 翻譯件20161018_第5頁](http://file2.renrendoc.com/fileroot_temp3/2021-10/19/e0e80b93-53a5-4717-bc32-879a9575932c/e0e80b93-53a5-4717-bc32-879a9575932c5.gif)
版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報或認(rèn)領(lǐng)
文檔簡介
1、暫態(tài)錄波型故障指示器技術(shù)條件和檢測規(guī)范(試行)Technical requirements and inspection regulations forTransient state waveform recording type fault indicator暫態(tài)錄波型故障指示器技術(shù)條件和檢測規(guī)范Technical requirements and inspection regulations forTransient state waveform recording type fault indicator1范圍scope 本標(biāo)準(zhǔn)規(guī)定了暫態(tài)錄波型故障指示器(以下簡稱指示器)的使用條件、技術(shù)
2、要求、選型原則、試驗項目及方法等。This regulation stipulates the working condition, technical requirements, selection principle, testing subjects and methods of transient state transient fault indicator (use “indicator” for short in the following part).本標(biāo)準(zhǔn)適用于額定電壓 6.6kV35kV、額定頻率50Hz的三相交流配電架空線路中監(jiān)測負(fù)荷、指示、上報短路和接地故障線路區(qū)段信息
3、的暫態(tài)錄波型指示器。 This standard is suitable for the transient waveform recording indicator to monitor the load, indication, uploading short circuit and earthing faults, for the three phase AC distribution overhead line with rated voltage of 6.6kv-35kv and rated frequency of 50Hz.2規(guī)范性引用文件normative reference
4、下列文件對于本文件的應(yīng)用是必不可少的。凡是注日期的引用文件,僅所注日期的版本適用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改單)適用于本文件。The following documents are essential to this regulation. For the cited documents with date, only the version with date is suitable for this document. If the cited document doesnt have a date, the lasted version will prev
5、ail for the document.GB/T 2423.1-2008 電工電子產(chǎn)品環(huán)境試驗 第2部分:試驗方法 試驗 A:低溫 Electric and electronic products environmental test, part 2: testing method, test A: low temperature.GB/T 2423.2-2008 電工電子產(chǎn)品環(huán)境試驗 第2部分:試驗方法 試驗 B:高溫 Electric and electronic products environmental test, part 2: testing method, test B: h
6、igh temperature.GB/T 2423.4-2008 電工電子產(chǎn)品基本環(huán)境試驗規(guī)程 試驗 Db:交變濕熱試驗方法 Electric and electronic products environmental test procedures, test Db: cyclic damp heat test.GB/T 2423.8-1995 電工電子產(chǎn)品環(huán)境試驗 第2部分:試驗方法 試驗Ed:自由跌落Electric and electronic products environmental test, part 2: testing method, test Ed: free fall
7、.GB/T 2423.17-2008 電工電子產(chǎn)品環(huán)境試驗 第2部分:試驗方法 試驗Ka:鹽霧 Electric and electronic products environmental test, part 2: testing method, test Ka: salt mist.GB 4208-2008 外殼防護(hù)等級(IP代碼)Enclosure protection class (IP code)GB/T 5169.11-2006 電工電子產(chǎn)品著火危險試驗 第11部分:灼熱絲/灼熱絲基本試驗方法 成品的灼熱絲可燃性試驗方法 Electric and electronic produc
8、ts fire hazard test, part 11: glowing filament basic testing method finished product of glowing filament flammable testing methodGB/T 5582-1993 高壓電力設(shè)備外絕緣污穢等級 High voltage electric equipment external insulation pollution gradeGB/T 11022-2011 高壓開關(guān)設(shè)備和控制設(shè)備標(biāo)準(zhǔn)的共用技術(shù)要求 Common technical requirements of high
9、voltage switchgear and control equipment standardGB/T 11287-2000 電氣繼電器 第21部分 量度繼電器和保護(hù)裝置的振動、沖擊、碰撞和地震試驗第一篇:振動試驗(正弦)Electric relay, part 21, measurement relay and protection device vibration, impact, collision and earthquake test GB/T 17626.2GB/T 17626.3GB/T 17626.4GB/T 17626.5GB/T 17626.8Electric comp
10、atibility test and measurement technique, static electricity discharge immunity testElectric compatibility test and measurement technique, RF electromagnetic field immunity test Electric compatibility test and measurement technique, electricity rapid transient change pulse immunity testElectric comp
11、atibility test and measurement technique, surge (impact) immunity testElectric compatibility test and measurement technique, power frequency magnetic field immunity testGB/T 17626.10 Electric compatibility test and measurement technique, damped oscillation magnetic field immunity testQ/GDW 11413-201
12、5 配電自動化無線公網(wǎng)通信模塊技術(shù)規(guī)范 Distribution automation wireless public network communication technical protocol 國家電網(wǎng)公司配電自動化DLT 634.5101-2002規(guī)約實施細(xì)則 protocol procedures國家電網(wǎng)公司配電自動化DLT 634.5104-2009規(guī)約實施細(xì)則 protocol procedures國家電網(wǎng)公司配電自動化系統(tǒng)安全防護(hù)方案 State Grid distribution automation system safety protection planIEEE St
13、d C37.111-1999 IEEE Standard Common Format for Transient Data Exchange (COMTRADE)for Power Systems3術(shù)語和定義Terminologies and definitions下列術(shù)語和定義適用于本文件。The following terminologies and definition suit for this document.13.1暫態(tài)錄波型故障指示器 transient recorder type fault indicator由采集單元和匯集單元組成,安裝在配電線路上,監(jiān)測線路運(yùn)行參數(shù),檢測
14、和指示各類短路、接地故障,向配電主站上送監(jiān)測信息和故障檢測數(shù)據(jù)。Consisted by acquisition and collection unit, mounted on the distribution line, monitoring line operation parameters, inspecting and indicating all kinds of short circuit and earthing faults, uploading monitoring information and fault detection data to distribution ma
15、ster station.3.2采集單元 acquisition unit安裝在配電線路上,能判斷并指示各類短路故障,采集、捕獲單相接地故障特征數(shù)據(jù),采集負(fù)荷電流等信息,并將故障信息、負(fù)荷電流等信息上傳至匯集單元。Mounted on the distribution line, able to judge and indicate all kinds of short circuit faults, acquiring single phase earthing fault characteristic data, acquiring load current information etc
16、, uploading the fault information and load current to collection unit.3.3匯集單元collection unit接收、處理采集單元上傳的配電線路故障、電流等信息,同時與配電主站進(jìn)行通信的單元,可采用架空導(dǎo)線懸掛安裝或電桿固定安裝方式。Receiving and handling the distribution line faults and current information uploaded by acquisition unit, at the same time communicating with maste
17、r station, mounted on the overhead line or on the pole.3.4相電場強(qiáng)度 phase voltage intensity某一架空載流導(dǎo)體對地電壓的比例感應(yīng)值。The ratio interaction value of certain overhead current-carrying conductor voltage to earth.4使用條件 Working condition4.1 正常使用條件 Normal working condition4.1.1 環(huán)境溫濕度 Ambient humidity and temperature
18、環(huán)境溫度、濕度分級見表1。See table 1 for environmental temperature and humidity表1 工作場所環(huán)境溫度和濕度分級 Table 1 Ambient temperature and humidity grade4.1.2 鹽霧 Salt mist鹽溶液的濃度應(yīng)為(51)%(質(zhì)量比),pH值應(yīng)在6.57.2內(nèi)(352)。The concentration of salt solution should be (51)%, and ph value is in 6.5-7.2 (352) .4.1.3 大氣壓力 Atmospheric pressu
19、re70 kPa106kPa。4.1.4 海拔高度 Altitude2Grade環(huán)境溫度 Ambient temperature 濕 度 Humidityworking conditionScopeMax changing rateminrelative humidity%max absolute humidityg/m3C15450.559529Not suggestedC225550.51010029OutdoorC340701.01010035Outdoor (suggested)CXSpecified注:CX 級別根據(jù)需要由用戶和制造商協(xié)商確定。CX grade shall be co
20、nfirmed by the negotiation of user and manufacture.安裝場地的海拔不超過2000m。The altitude of mounting ground should not exceed 2000m.4.1.5 污穢等級 Pollution grade不低于V級。Not lower than Grade V.4.2 特殊使用條件 Special working conditiona)b)凡是需要滿足 4.1 條規(guī)定正常環(huán)境條件之外的特殊使用條件,由項目單位在招標(biāo)文件中明確提出。If there are some special requiremen
21、ts other than the terms in 4.1, the project tenderee should clearly propose the requirements in the biding documents.對于安裝在海拔高于 2000m 處指示器的外絕緣,應(yīng)滿足 GB/T 11022-2011 第 2.3.2 條的要求。For the indicator external insulation mounted on the altitude of 2000m, the requirements of 2.3.2 in GB/T 11022-2011 should b
22、e met.5技術(shù)要求 Technical requirements5.1 總體要求 General requirementsa)b)c)d)e)指示器由至少 3 個采集單元和 1 個匯集單元組成。The indicator should be consisted by at least 3 sets of acquisitionn units and 1 collection unit.匯集單元最少支持 3 組采集單元(每組共 3 個)的數(shù)據(jù)匯集。The collection unit should support the data gathering of at least 3 sets
23、of acquisition units.采用小型化、低功耗、免維護(hù)、高可靠設(shè)計。Design should be in small size, low power consumption, maintenance free and reliable. 指示器使用壽命不小于 8 年,采集單元后備電源不低于設(shè)備使用壽命。The working life of indicator should be less than 8 years, and the back up power source of acquisition unit should not shorter than the life
24、 of the equipment.指示器平均無故障時間 MTBF70000h。5.2 外觀與結(jié)構(gòu) Appearance and structurea) 應(yīng)具備唯一硬件版本號、軟件版本號、類型標(biāo)識代碼、ID 號標(biāo)識代碼和二維碼,并按照附錄 A方式統(tǒng)一進(jìn)行識別。The equipment should have exclusive hardware version code, software version code, TI code, ID code and QR code, see appendix A.b) 采集單元重量不大于 1kg,架空導(dǎo)線懸掛安裝的匯集單元重量不大于 1.5kg。T
25、he weight of acquisition unit should not be more than 1kg, and collection unit on the overhead line shall not bigger than 1.5kg.c) 采集單元報警指示燈應(yīng)采用不少于 3 只超高亮 LED 發(fā)光二極管,布置在采集單元正常安裝位置的下方,地面 360可見。匯集單元的底部應(yīng)具備綠色運(yùn)行閃爍指示燈,在桿下明顯可見。The alarm lights of acquisition unit shall not less than 3 ultra-brightness LED, m
26、ounted beneath the acquisition unit and are visible in 360 degrees. A green flashing operation lamp should be equipped beneath the collection unit which is clearly seen under the pole.d) 采集單元應(yīng)有電源、電池正負(fù)極等外接端子。匯集單元應(yīng)有 SIM 卡槽,外接端子及 SIM 卡規(guī)格參數(shù)應(yīng)按照附錄 B。The acuqustion unit should have power source and battery
27、 positive and negative terminals etc. The collection unit should have SIM card slot. The external terminal and SIM card specification shall meet the parameter in appendix B.e) 采集單元宜采用雙 TA 回路設(shè)計,取電回路宜采用高磁導(dǎo)率的磁芯。The collection unit is better to use double TA loop design, and power taking loop should use
28、 high permeability magnetic core.f) 采集單元和架空導(dǎo)線懸掛安裝的匯集單元外殼應(yīng)采用非金屬阻燃材料,能承受 GB/T 5169.11規(guī)定的 5 級著火危險。指示器外殼應(yīng)采用抗紫外線、抗老化、抗沖擊和耐腐蝕材料,應(yīng)有足夠的機(jī)械強(qiáng)度,能承受使用或搬運(yùn)中可能遇到的機(jī)械力,滿足長期戶外應(yīng)用免維護(hù)要求。The acquisition unit and overhead line mounted collection unit enclosure should use non-metallic flame resistant material, and can bear
29、Grade 5 fire hazard stipulated in GB/T 5169.11. The enclosure of indicator should use UV protection, anti-aging, impact-proof and anti-corrosion materials, and should have enough mechanical strength which can bear the mechanical force may meet during working or transporting. And the outdoor maintena
30、nce free requirements shall also be met.g) 卡線結(jié)構(gòu)應(yīng)在不同截面線纜上安裝方便可靠,安裝牢固且不造成線纜損傷,支持帶電安裝和拆卸。結(jié)構(gòu)件經(jīng) 50 次裝卸應(yīng)到位且不變形,不影響故障檢測性能。The clamp structure shall be easily mounted on different sections of the cable. The installation should be firm and make no damage to the cable. Installation and disassembly with power
31、on shall be supported. After 50 times of installation and disassembly, there shall be no deformation on the structure, and the performance shall not be affected.h) 外觀應(yīng)整潔美觀、無損傷或機(jī)械形變,內(nèi)部元器件、部件固定應(yīng)牢固,封裝材料應(yīng)飽滿、牢固、光亮、無流痕、無氣泡。The appearance shall be tidy and good-looking, without damage or mechanical deforma
32、tion. All the inner components or parts should be fixed firmly, and the sealing materials shall be full, firm, bright, non-flow mark, and free of bubbles. 5.3 電源要求 Power source requirements 5.3.1 采集單元 Acquisition unita)應(yīng)采用 TA 取電并輔以超級電容作為主供電源,能量密度不低于鋰電池的非充電電池作為后備電源。主供電源和后備電源相互獨立,當(dāng)主供電源不能維持全功能工作時,后備電源自
33、動投入。當(dāng)主供電源恢復(fù)時,自動切回主供電源供電。超級電容在充滿電時應(yīng)可獨立維持全功能工作不小于 12h。Use TA power taking supplemented by super capacitor as main power source, and take a non-rechargeable battery with its power density not lower than lithium battery as back up power. The main power source is independent from back up power, and when
34、the main power can not sustain the full function, the back up power shall automatically put into use. When the main power source is recovered, the power supply shall automatically switch back to main power source. The equipment shall be able to work at least 12 hours with the fully charged super cap
35、acitor.b)c)線路負(fù)荷電流不小于 5A 時,TA 取電 5s 內(nèi)應(yīng)能滿足全功能工作要求。線路負(fù)荷電流低于 5A 且超級電容失去供電能力時,應(yīng)至少能判斷短路故障,定期采集負(fù)荷電流,并上傳至匯集單元。When the line load current is no less than 5A, the TA power taking should meet the requirement of full function working in 5s. When the line load current is lower than 5A and the super capacitor los
36、es its power supply ability, the equipment shall at least be able to judge short circuit fault, periodically acquire load current and upload to the collection unit.非充電電池額定電壓應(yīng)不小于 DC3.6V,容量不低于 8.5Ah。在電池單獨供電時,最小工作電流應(yīng)不大于 80A。在不更換電池情況下,持續(xù)工作時間應(yīng)不低于 8 年,且滿足閃光報警大于 2000小時。The rated voltage of non-rechargeable
37、 battery shall not be less than DC 3.6V, with the capacity no lower than 8.5Ah.When using the battery independently to supply power, the min working current shall not be bigger than 80A. Without changing battery, the working hour should not be less than 8 years and the alarm flashing time shall be b
38、igger than 2000 hours. 5.3.2 匯集單元 Collection unita)b)c)可采用太陽能板或 TA 取電方式供電,并輔以可充電電池作為后備電源。Use solar panel or TA power taking for power supply, and can be supplemented with chargeable battery as back up power.采用太陽能板供電的匯集單元太陽能板額定輸出電壓不低于 DC15V,容量不低于 15VA;電池額定電壓為 DC12V,容量不低于 7Ah。采用 TA 取電的匯集單元電池額定電壓應(yīng)不小于 D
39、C3.6V,容量不低于 8.5Ah。The rated outgoing voltage using solar panel power supply of collection unit shall not lower than DC15V, with capacity not lower than 15VA. The rated voltage is DC12V, with capacity no less than 7Ah. The rated voltage of collection unit with TA power taking shall not less than DC 3
40、.6V.匯集單元整機(jī)功耗(在線,不通信)不大于 0.2VA。電池獨立供電的情況下,應(yīng)能全功能工作不少于 7 天。The power consumption of whole collection unit set shall not bigger than 0.2VA. Under the circumstance of sole power supply by battery, it should be able to work in full function for no less than 7 days.5.4 絕緣性能 Insulation performance5.4.1 絕緣電阻
41、 Insulation resistance電桿固定安裝匯集單元電源回路與外殼之間絕緣電阻5M(使用250V絕緣電阻表,額定絕緣電壓Ui60V)。The insulation resistance between the collection unit mounted on the pole and enclosure shall be 5M (use 250 insulation resistance meter, with rated insulation voltage Ui60V )5.4.2 絕緣強(qiáng)度 Insulation strength電桿固定安裝匯集單元電源回路與外殼之間額定絕
42、緣電壓Ui60V時,施加500V工頻電壓應(yīng)無擊穿、無閃絡(luò)。When the rated insulation voltage between pole mounted collection unit power loop and enclosure is Ui60V, add a 500V power frequency voltage, and there shall be no broken through and flashover. 5.5 通信要求 Communication requirements5.5.1 采集單元與匯集單元之間通訊機(jī)制 Communication mechan
43、ism between acquisition and collection unitsa)b)c)采集單元應(yīng)能主動實時上送故障信息,并每 5min 記錄一次負(fù)荷數(shù)據(jù)。The acquisition unit shall be able to actively real-time upload fault information, and record the load data every 5ms.應(yīng)支持實時故障、負(fù)荷等信息召測,同時并能根據(jù)工作電源情況定期或定時上送至匯集單元。Real-time fault and load information interrogation should
44、 be supported, at the same time the information can be periodically uploaded to collection unit based on the working power condition.采集單元定時發(fā)送信息給匯集單元,匯集單元在 10min 內(nèi)沒有收到采集單元信息,即視為通信異常。采集單元與匯集單元通信故障時應(yīng)能將報警信息上送至配電主站。The acquisition unit will periodically send information to collection unit. If the collect
45、ion has not received the acquisition unit information in 10m, we consider this as a communication exception.5.5.2 匯集單元與主站之間通訊機(jī)制 Communication mechanism between collection unit and master stationa)b)c)可通過配電主站對匯集單元和采集單元進(jìn)行參數(shù)設(shè)置。The parameter of acquisition and collection units can be configured by distr
46、ibution master station.匯集單元應(yīng)支持?jǐn)?shù)據(jù)定時上送、負(fù)荷越限上送、重載上送和主動召測,最小上送時間間隔為15min。The collection unit should support data timely upload, load over-limit upload, heavy load upload and active interrogation, and the min uploading interval shall be 15mins.應(yīng)滿足國家電網(wǎng)公司配電自動化系統(tǒng)安全防護(hù)方案信息安全防護(hù)配置要求。It shall meet the safety pro
47、tection configuration requirements of State Grid distribution automation system safety protection plan. 5.5.3 通訊距離及規(guī)約 Communication distance and protocola)b)c)采集單元與匯集單元通過無線雙向通信,可視無遮擋通信距離應(yīng)不低于 50 米。The acquisition and collection units use wireless two directions communication, and the visual non-block
48、ing communication distance shall be no less than 50m. 采集單元與匯集單元之間如通過無線中繼或路由方式通信,采集單元之間通信距離應(yīng)不低于500 米。If wireless relay or router is used in the communication between acquisition and collection unit, the communication distance between acquisition units shall be not less than 500m.匯集單元與主站通過無線公網(wǎng)雙向通信,通信規(guī)
49、約應(yīng)遵循國家電網(wǎng)公司 DL/T 634.5101-2002規(guī)約實施細(xì)則、國家電網(wǎng)公司 DL/T 634.5104-2009 規(guī)約實施細(xì)則。The collection unit and master station use wireless public network to realize two direction communications, and the protocol shall follow DL/T 634.5101-2002 and DL/T 634.5104-2009. 5.5.4 對時及守時 Time verification and punctuality4a) 每
50、組采集單元三相時間同步誤差不大于 100s。The time difference of 3 phase synchronization of every sets of acquisition units shall not be bigger than 100s.b) 匯集單元應(yīng)支持主站及北斗或其他同步時鐘裝置對時,守時精度2s/24h。When the collection unit supports master station or Beidou for clock synchronization, the punctuality accuracy should be 2s/24h.
51、5.6 功能要求 Functions requirements5.6.1 短路和接地故障識別 Short circuit and earthing fault detection5.6.1.1 指示器短路故障判別應(yīng)自適應(yīng)負(fù)荷電流大小,當(dāng)檢測到電流突變且突變啟動值宜不低于150A,突變電流持續(xù)一段時間后,各相電場強(qiáng)度大幅下降,且殘余電流不超過 5A 零漂值,應(yīng)能就地采集故障信息,以閃光形式就地指示故障,且能將故障信息上傳至主站。The short circuit judgment of indicator shall be self-modified with the size of load
52、current. When the current sudden changes and the changing value is not lower than 150A, the changing current lasts for a period and field intensity of every phase decreases heavily with a residual current not over 5A null shift value, the fault information shall be gathered locally. The fault shall
53、be indicated as flashing, and the fault information shall be able to uploaded to master station.5.6.1.2 發(fā)生接地故障,當(dāng)指示器不能判斷出接地故障處于安裝位置的上游和下游時,采集單元應(yīng)能就地采集故障信息和波形,且能將故障信息和波形傳至主站進(jìn)行判斷,同時匯集單元應(yīng)能接收主站下發(fā)的故障數(shù)據(jù)信息,采集單元以閃光形式指示故障;當(dāng)指示器能判斷出接地故障處于安裝位置的上游和下游時,采集單元應(yīng)能就地采集故障信息和波形,以光形式指示故障,且能將故障信息和波形上傳至主站。When the indicator c
54、annot identify whether the fault is in the upstream or downstream of the local if an earthing fault happens, the acquisition unit shall be able to acquire fault information and waveform, upload the fault information and waveform to master station. At the same time, the collection unit can receive th
55、e fault data information sent by master station, and acquisition unit will flash to indicate the fault. When the indicator is able to judge the local, the acquisition unit can locally acquire fault information and waveform, and indicate the fault with flashing and upload the fault information and wa
56、veform to master station. 5.6.1.35.6.1.4指示器應(yīng)能監(jiān)測線路三相負(fù)荷電流、故障電流、相電場強(qiáng)度等運(yùn)行信息和主供電源、后備電源等狀態(tài)信息,并將以上信息上送至主站,同時采集單元具備故障錄波功能。The indicator shall be able to monitor the operation information of 3 phase load current, fault current, phase electric field strength, and status information of main power supply and ba
57、ckup power supply, and upload the above information to master station. At the same time, the acquisition unit has the fault waveform recording function. 接地故障判別適應(yīng)中性點不接地、經(jīng)消弧線圈接地、經(jīng)小電阻接地等配電網(wǎng)中性點接地方式,以及不同配電網(wǎng)網(wǎng)架結(jié)構(gòu);滿足金屬性接地、弧光接地、電阻接地等不同接地故障檢測要求。The earth fault judgment is suitable for the neutral point non-connection to earth, Peterson coil earthing, and earthing with a minor resistance. It shall also meet the detection requirements of
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025至2030年電弧式噴金機(jī)項目投資價值分析報告
- 2025至2030年中國專用節(jié)能離合器數(shù)據(jù)監(jiān)測研究報告
- 2025年中國金屬共軛環(huán)填料市場調(diào)查研究報告
- 技師辭職申請書
- 2025年度食品包裝設(shè)計四人股份合作協(xié)議書
- 房屋裝修施工協(xié)議模板
- 診所地址變更申請書
- 電影院轉(zhuǎn)正申請書
- 2025年中國充氣泳圈市場調(diào)查研究報告
- 臨時裝修居間服務(wù)協(xié)議
- 小學(xué)數(shù)學(xué)教學(xué)評一體化教學(xué)探究
- 2024年保安員考試題庫【典型題】
- 人教版數(shù)學(xué)八年級下冊第十九章課堂同步練習(xí)
- 第一章創(chuàng)新意識課件
- 2024-2029年中國R290制冷劑行業(yè)市場現(xiàn)狀分析及競爭格局與投資發(fā)展研究報告
- 售后工程師績效考核指南
- 自動測試系統(tǒng)第1章第1節(jié)測試系統(tǒng)發(fā)展綜述
- 北師大版(2019)選擇性必修第三冊Unit 7 Careers Topic Talk 導(dǎo)學(xué)案
- 春節(jié)復(fù)工復(fù)產(chǎn)安全教育培訓(xùn)
- 2024年廣西公務(wù)員考試行測真題及答案解析
- 護(hù)理質(zhì)量改進(jìn)項目
評論
0/150
提交評論