![現(xiàn)場(chǎng)臨時(shí)用電專項(xiàng)施工方案.doc_第1頁(yè)](http://file1.renrendoc.com/fileroot_temp2/2020-3/21/94686a98-bb6d-48ec-b4d1-450d65b7e4db/94686a98-bb6d-48ec-b4d1-450d65b7e4db1.gif)
![現(xiàn)場(chǎng)臨時(shí)用電專項(xiàng)施工方案.doc_第2頁(yè)](http://file1.renrendoc.com/fileroot_temp2/2020-3/21/94686a98-bb6d-48ec-b4d1-450d65b7e4db/94686a98-bb6d-48ec-b4d1-450d65b7e4db2.gif)
![現(xiàn)場(chǎng)臨時(shí)用電專項(xiàng)施工方案.doc_第3頁(yè)](http://file1.renrendoc.com/fileroot_temp2/2020-3/21/94686a98-bb6d-48ec-b4d1-450d65b7e4db/94686a98-bb6d-48ec-b4d1-450d65b7e4db3.gif)
![現(xiàn)場(chǎng)臨時(shí)用電專項(xiàng)施工方案.doc_第4頁(yè)](http://file1.renrendoc.com/fileroot_temp2/2020-3/21/94686a98-bb6d-48ec-b4d1-450d65b7e4db/94686a98-bb6d-48ec-b4d1-450d65b7e4db4.gif)
![現(xiàn)場(chǎng)臨時(shí)用電專項(xiàng)施工方案.doc_第5頁(yè)](http://file1.renrendoc.com/fileroot_temp2/2020-3/21/94686a98-bb6d-48ec-b4d1-450d65b7e4db/94686a98-bb6d-48ec-b4d1-450d65b7e4db5.gif)
已閱讀5頁(yè),還剩9頁(yè)未讀, 繼續(xù)免費(fèi)閱讀
版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
大連和平建筑安裝工程有限公司施工現(xiàn)場(chǎng)臨時(shí)用電組織設(shè)計(jì)一、 工程概況本工程為大連長(zhǎng)興島經(jīng)濟(jì)區(qū)工程建設(shè)事務(wù)中心負(fù)責(zé)新建的中華人民共和國(guó)長(zhǎng)興島出入境檢驗(yàn)檢疫局綜合實(shí)驗(yàn)項(xiàng)目??偨ㄖ娣e8500 m2。分成4個(gè)單體。其中綜合實(shí)驗(yàn)用房1#樓分成A、B兩個(gè)區(qū),其中A區(qū)地上六層,地下一層,B區(qū)地上一層,門衛(wèi)一地上一層,;門衛(wèi)二地上一層,接樣室地上一層,全部為混凝土框架結(jié)構(gòu)。位于大連長(zhǎng)興島綜合區(qū),由大連和平建筑安裝工程有限公司承建。概況如下:工 程 名 稱建筑面積層 數(shù)結(jié)構(gòu)中華人民共和國(guó)長(zhǎng)興島出入境檢驗(yàn)檢疫局綜合實(shí)驗(yàn)用房項(xiàng)目8500地下一層,地上六層框架、結(jié)構(gòu)施工范圍包括:土建、電氣、水暖等工程。施工現(xiàn)場(chǎng)空中及地下無(wú)障礙物。自備發(fā)電機(jī)組電源,回路線路長(zhǎng)度分別為80m、100m、150m,由施工區(qū)東南側(cè)進(jìn)入施工現(xiàn)場(chǎng)。施工現(xiàn)場(chǎng)臨時(shí)用電工程采用三相四線,電源側(cè)工作零線進(jìn)行重復(fù)接地,然后配出工作零線和保護(hù)零線,形成五線制,并由總發(fā)電機(jī)組負(fù)荷側(cè)配出至各分路分配電箱,使施工現(xiàn)場(chǎng)形成局部TN-S接零保護(hù)系統(tǒng)。施工區(qū)域雷暴日數(shù)19.2d/a,土壤電阻系數(shù)0.810cm二、 確定電源進(jìn)線、配電裝置、用電設(shè)備位置及線路本工程自備發(fā)電機(jī)組,采用YC-335+210三相五線電纜架空進(jìn)入現(xiàn)場(chǎng)。根據(jù)現(xiàn)場(chǎng)施工設(shè)備平面布置在現(xiàn)場(chǎng)配出四個(gè)動(dòng)力回路。各配出回路設(shè)置分配電箱,分配電箱均設(shè)置在負(fù)荷相對(duì)集中的位置。具體線路走向詳見(jiàn)“臨時(shí)用電平面布置圖”總配電箱及各分配電箱、開(kāi)關(guān)箱均設(shè)重復(fù)接地。三、 負(fù)荷計(jì)算(一) 用電設(shè)備一覽表及設(shè)備容量計(jì)算施工用電動(dòng)力設(shè)備及照明負(fù)荷明細(xì)表序號(hào)設(shè) 備 機(jī) 具 名 稱銘牌、技術(shù)數(shù)據(jù)(kw)數(shù)量1塔吊QTZ6327.0012電渣壓力焊45.0013交流電焊機(jī)21.0024滾筒攪拌機(jī)7.5015圓 盤 鋸3.0026水 泵5.5067插入式振搗器1.1038鋼筋彎曲機(jī)3.0019 鋼筋切斷調(diào)直機(jī)9.50110鋼筋切斷機(jī)4.00111絞 絲 機(jī)4.00112鏑 燈3.50213白 熾 燈0.10301415(二) 所有用電設(shè)備的計(jì)算負(fù)荷1、 施工現(xiàn)場(chǎng)有許多用電設(shè)備,有以下幾個(gè)問(wèn)題需要考慮:各用電設(shè)備不一定同時(shí)運(yùn)行。各用電設(shè)備不可能同時(shí)滿負(fù)荷運(yùn)行。設(shè)備運(yùn)行時(shí)存在著效率,即設(shè)備存在著功率損失。不同的設(shè)備其工作制并不相同。輸電線路、變壓器等本身存在著能量的損耗。因此,用電設(shè)備的實(shí)際負(fù)荷Pjs與設(shè)備容量Ps之間并不相等,應(yīng)按下式計(jì)算:有功計(jì)算負(fù)荷Pjs (kw): Pjs=kxPs無(wú)功計(jì)算負(fù)荷Qjs (kvar):Qjs=Pjstan視在計(jì)算負(fù)荷Sjs (kvA): Sjs=Pjs+Qjs電流Ijs(kA):Ijs=Sjs/3Ve=Pjs/3Vecos以上各式中 kx需要系數(shù);Ve用電設(shè)備的額定電壓;cos、tan用電設(shè)備的平均功率因子及對(duì)應(yīng)的正確值。2、 計(jì)算發(fā)電機(jī)組用電負(fù)荷如下:塔吊kx=0.50、cos=0.60、tan=1.33將Jc=60統(tǒng)一換算到Jc1=50的額定容量Pjs=kxPe=0.501(0.60/0.50)27=13.15kwQjs=Pjstan=13.151.33=17.48kvar滾筒攪拌機(jī)kx=0.75、cos=0.85、tan=0.62Pjs=kxPe=0.757.50=6.75kwQjs=Pjstan=6.750.62=4.19kvar木工圓盤鋸kx=0.30、cos=0.60、tan=1.33Pjs=kxPe=0.303.002=2.7kwQjs=Pjstan=2.71.33=3.59kvar水泵kx=0.30、cos=0.70、tan=1.02Pjs=kxPe=0.305.506=9.9kwQjs=Pjstan=9.91.02=10.1kvar插入式振搗器kx=0.30、cos=0.70、tan=1.02Pjs=kxPe=0.301.103=0.99kwQjs=Pjstan=0.991.02=1.01kvar鋼筋彎曲機(jī)kx=0.30、cos=0.70、tan=1.02Pjs=kxPe=0.303.003=2.70kwQjs=Pjstan=2.701.02=2.75kvar鋼筋調(diào)直切斷機(jī)kx=0.30、cos=0.70、tan=1.02Pjs=kxPe=0.309.50=2.85kwQjs=Pjstan=2.851.02=2.91kvar鋼筋切斷機(jī)kx=0.30、cos=0.70、tan=1.02Pjs=kxPe=0.304.002=1.20kwQjs=Pjstan=1.201.02=1.22kvar電渣壓力焊機(jī)kx=0.40、cos=0.50、tan=1.73將Jc=50統(tǒng)一換算到Jcl=100的額定容量Pjs=kxPe=0.401(0.50/1.00)45.00=12.73kwQjs=Pjstan=12.731.73=22.02kvar交流電焊機(jī)kx=0.35、cos=0.40、tan=2.29將Jc=50統(tǒng)一換算到Jc1=100的額定容量Pjs=kxPe=0.351(0.50/1.00)21.002=15.60kwQjs=Pjstan=15.602.29=35.72kvar 絞絲機(jī)kx=0.30、cos=0.70、tan=1.02Pjs=kxPe=0.304.00=1.20kwQjs=Pjstan=1.201.02=1.22kvar(12)施工與生活照明kx=0.50、cos=0.50、tan=1.73Pjs=kxPe=0.50(3.502+0.1030)=5.0kwQjs=Pjstan=5.01.73=8.65kvar總的計(jì)算負(fù)荷計(jì)算,1#總箱同期系數(shù)取kx=0.75。1#總箱的有功功率:Pjs=kxPjs=0.75(13.15+6.75+2.70+9.90+0.99+2.70+2.85+1.20+12.73+15.60+1.20+5.00)=56.08kw總的無(wú)功功率Qjs=kxQjs=0.75(17.48+4.19+3.59+10.10+1.01+2.75+2.91+1.22+22.02+35.72+1.22+8.65)=83.15kvar總的視在功率Sjs=Pjs+Qjs=56.08+83.15=100.29kvA總的計(jì)算電流Ijs=Sjs/1.732Ve=83.15/(1.7320.38)=125.98A四、 選擇(驗(yàn)算)發(fā)電機(jī)組現(xiàn)場(chǎng)發(fā)電機(jī)組功率為200kw,它的功率大于現(xiàn)場(chǎng)臨時(shí)用電總的功率 125.23KW,能夠滿足使用要求五、 選擇總配電箱的進(jìn)線截面與進(jìn)線開(kāi)關(guān)、漏電保護(hù)器(一) 根據(jù)計(jì)算出的總電流Ijs查表選用變壓器至總配電箱的導(dǎo)線截面和型號(hào),由于變壓器至總開(kāi)關(guān)箱約100m與80m,距離較短可不按控電壓降的選擇。選擇導(dǎo)線截面:上面已經(jīng)計(jì)算出1#總箱計(jì)算電流Ijs=324.12A,2#總箱計(jì)算電流Ijs=312.75A,查表得室外架空線路25時(shí)銅芯橡皮絕緣導(dǎo)線YC-350+216+YC-335+210,近似于YC-395+225,其安全載流量為380A,故均滿足使用要求。(二) 根據(jù)計(jì)算出的Ijs選擇總進(jìn)線開(kāi)關(guān)機(jī)總漏電保護(hù)器(中小型工程經(jīng)常采用總隔離總漏電保護(hù)形式。而對(duì)于大型工程,經(jīng)常采用分路隔離分路漏電保護(hù)的配電方式,本案選擇前者。因其1#總干線計(jì)算電流Ijs=324.12A,空氣斷路器額定電流Ie=1.3Ijs=363.73A。2#總干線計(jì)算電流Ijs=312.75A,空氣斷路器額定電流Ie=1.3Ijs=356.80A。故均選用DZ20T-400透明外殼斷路器,RCD選用帶過(guò)電流保護(hù)的漏電開(kāi)關(guān)。采用LBM 漏電保護(hù)器與透明外殼式空氣斷路器配合使用,供三項(xiàng)動(dòng)力負(fù)載接線漏電保護(hù)器的額定漏電動(dòng)作電流應(yīng)大于30mA,額定漏電動(dòng)作時(shí)間應(yīng)大于0.1s,但其額定額定動(dòng)作電流與額定漏電動(dòng)作時(shí)間的乘積不大于30mAs。(三) 總干線電壓損失校驗(yàn)電壓損失校驗(yàn)按下式計(jì)算: U=(PjsL)/(CS)式中:Pjs負(fù)荷計(jì)算功率kwL導(dǎo)線長(zhǎng)度mC系數(shù)(三相四線取77)S導(dǎo)線截面mm變壓器至總配電箱電源干線長(zhǎng)度100m U=(59.39100)/(7795)=1.225符合要求。六、 選擇分配電箱的進(jìn)線截面與進(jìn)線開(kāi)關(guān)、漏電保護(hù)器(一) 計(jì)算各分路用電負(fù)荷如下:1、1#回路:塔吊kx=0.50、cos=0.60、tan=1.33將Jc=60統(tǒng)一換算到Jc1=50的額定容量Pjs=kxPe=0.501(0.60/0.50)27=13.15kwQjs=Pjstan=13.151.33=17.48kvar木工圓盤鋸kx=0.30、cos=0.60、tan=1.33Pjs=kxPe=0.303.00=0.90kwQjs=Pjstan=0.901.33=1.20kvar滾筒攪拌機(jī)kx=0.75、cos=0.85、tan=0.62Pjs=kxPe=0.7524.00=18.00kwQjs=Pjstan=18.000.62=11.16kvar水泵kx=0.75、cos=0.85、tan=0.62Pjs=kxPe=0.758.80=6.60kwQjs=Pjstan=6.600.62=4.09kvar施工與生活照明kx=0.50、cos=0.50、tan=1.73Pjs=kxPe=0.50(3.503+1.003+0.1010)=7.25kwQjs=Pjstan=7.251.73=12.54kvar1#分路負(fù)荷計(jì)算,分箱同期系數(shù)取kx=0.75。有功功率:Pjs=kxPjs=0.75(13.15+0.90+18.00+6.60+7.25)=34.43kw無(wú)功功率Qjs=kxQjs=0.75(17.48+1.20+11.16+4.09+12.54)=34.85kvar視在功率Sjs=Pjs+Qjs=34.43+34.85=48.99kvA計(jì)算電流Ijs=Sjs/1.732Ve=48.99/(1.7320.38)=74.45A2、2#回路交流電焊機(jī)kx=0.35、cos=0.40、tan=2.29將Jc=50統(tǒng)一換算到Jc1=100的額定容量Pjs=kxPe=0.351(0.50/1.00)21=5.20kwQjs=Pjstan=5.202.29=11.91kvar 水泵kx=0.30、cos=0.70、tan=1.02Pjs=kxPe=0.305.50=1.65kwQjs=Pjstan=1.651.02=1.68kvar插入式振搗器kx=0.30、cos=0.70、tan=1.02Pjs=kxPe=0.301.10=0.33kwQjs=Pjstan=0.331.02=0.34kvar鋼筋彎曲機(jī)kx=0.30、cos=0.70、tan=1.02Pjs=kxPe=0.303.00=0.90kwQjs=Pjstan=0.901.02=0.92kvar鋼筋調(diào)直切斷機(jī)kx=0.30、cos=0.70、tan=1.02Pjs=kxPe=0.309.50=2.85kwQjs=Pjstan=2.851.02=2.91kvar2#分路的計(jì)算負(fù)荷計(jì)算,分箱同期系數(shù)取kx=0.75。有功功率:Pjs=kxPjs=0.75(13.15+12.73+5.20+1.65+0.33+0.90+2.85)=27.61kw無(wú)功功率:Qjs=kxQjs=0.75(17.48+22.02+11.91+1.68+0.34+0.92+2.91)=42.95kvar視在功率:Sjs=Pjs+Qjs=27.61+42.95=51.06kvA計(jì)算電流:Ijs=Sjs/1.732Ve=51.06/(1.7320.38)=77.60 A3、3#回路塔吊kx=0.50、cos=0.60、tan=1.33將Jc=60統(tǒng)一換算到Jc1=50的額定容量Pjs=kxPe=0.501(0.60/0.50)20.50=11.23kwQjs=Pjstan=11.231.33=14.93kvar電渣壓力焊機(jī)kx=0.40、cos=0.50、tan=1.73將Jc=50統(tǒng)一換算到Jcl=100的額定容量Pjs=kxPe=0.401(0.50/1.00)45=12.73kwQjs=Pjstan=12.731.73=22.02kvar交流電焊機(jī)kx=0.35、cos=0.40、tan=2.29將Jc=50統(tǒng)一換算到Jc1=100的額定容量Pjs=kxPe=0.351(0.50/1.00)21=5.20kwQjs=Pjstan=5.202.29=11.91kvar 木工圓盤鋸kx=0.30、cos=0.60、tan=1.33Pjs=kxPe=0.303.00=0.90kwQjs=Pjstan=0.901.33=1.20kvar施工與生活照明kx=0.50、cos=0.50、tan=1.73Pjs=kxPe=0.50(3.503+1.003+0.1010)=7.25kwQjs=Pjstan=7.251.73=12.54kvar水泵kx=0.30、cos=0.70、tan=1.02Pjs=kxPe=0.305.50=1.65kwQjs=Pjstan=1.651.02=1.68kvar3#分路的計(jì)算負(fù)荷計(jì)算,分箱同期系數(shù)取kx=0.75。有功功率:Pjs=kxPjs=0.75(11.23+12.73+5.20+0.90+7.25+1.65)=29.22kw無(wú)功功率:Qjs=kxQjs=0.75(14.93+22.02+11.91+1.20+12.54+1.68)=48.21kvar視在功率:Sjs=Pjs+Qjs=29.22+48.21=56.37kvA計(jì)算電流:Ijs=Sjs/1.732Ve=56.37/(1.7320.38)=85.67A4、4#回路塔吊kx=0.50、cos=0.60、tan=1.33將Jc=60統(tǒng)一換算到Jc1=50的額定容量Pjs=kxPe=0.501(0.60/0.50)25.70=14.08kwQjs=Pjstan=14.081.33=18.72kvar插入式振搗器kx=0.30、cos=0.70、tan=1.02Pjs=kxPe=0.301.103=0.99kwQjs=Pjstan=0.991.02=1.01kvar鋼筋彎曲機(jī)kx=0.30、cos=0.70、tan=1.02Pjs=kxPe=0.303.00=0.90kwQjs=Pjstan=0.901.02=0.92kvar鋼筋調(diào)直切斷機(jī)kx=0.30、cos=0.70、tan=1.02Pjs=kxPe=0.309.50=2.85kwQjs=Pjstan=2.851.02=2.91kvar滾筒攪拌機(jī)kx=0.75、cos=0.85、tan=0.62Pjs=kxPe=0.7524.00=18.00kwQjs=Pjstan=18.000.62=11.16kvar交流電焊機(jī)kx=0.75、cos=0.85、tan=0.62Pjs=kxPe=0.758.80=6.60kwQjs=Pjstan=6.600.62=4.09kvar4#分路的計(jì)算負(fù)荷計(jì)算,分箱同期系數(shù)取kx=0.75。有功功率:Pjs=kxPjs=0.75(14.08+0.99+0.90+2.85+18.00+6.60)=32.57kw無(wú)功功率:Qjs=kxQjs=0.75(18.72+1.01+0.92+2.91+11.16+4.09)=29.11kvar視在功率:Sjs=Pjs+Qjs=32.57+29.11=43.68kvA計(jì)算電流:Ijs=Sjs/1.732Ve=43.68/(1.7320.38)=66.39A(二)分路導(dǎo)線選擇1#回路:YC-335+210電纜,可以載流量為142A,大于Ijs=74.45A,此電纜架空或埋地敷設(shè)至1#分配電箱。2#回路:YC-325+26電纜,可以載流量為115A,大于Ijs=77.60A,此電纜架空或地埋敷設(shè)至1#分配電箱。3#回路:YC-335+210電纜,可以載流量為142A,大于Ijs=85.67A,此電纜架空或埋地敷設(shè)至1#分配電箱。4#回路:YC-335+26電纜,可以載流量為115A,大于Ijs=66.39A,此電纜架空或埋地敷設(shè)至2#分配電箱。(四) 設(shè)計(jì)配電裝置及電器1、 分配電箱接線與電器選擇(1)1#分配電箱總支線計(jì)算電流Ijs=74.45A,空氣短路額定電流Ie=1.3Ijs=96.79A.故選用DZ20T200透明外殼式斷路器,RCD選用帶過(guò)電流保護(hù)的漏電開(kāi)關(guān)。其余回路按其設(shè)備額定計(jì)算容量選取DZ20T100、DZ2060或DZ20T40透明外殼式斷路器,RCD選用帶過(guò)電路保護(hù)的漏電開(kāi)關(guān)(2)2#分配電箱總支線計(jì)算電流Ijs=77.60A,空氣短路額定電流Ie=1.3Ijs=100.88A.故選用DZ20T200透明外殼式斷路器,RCD選用帶過(guò)電流保護(hù)的漏電開(kāi)關(guān)。其余回路按其設(shè)備額定計(jì)算容量選取DZ20T100、DZ20T60或DZ20T40透明外殼式斷路器,RCD選用帶過(guò)電流保護(hù)的漏電開(kāi)關(guān)。(3)1#分配電箱總支線計(jì)算電流Ijs=85.67A,空氣短路額定電流Ie=1.3Ijs=111.37A.故選用DZ20T200透明外殼式斷路器,RCD選用帶過(guò)電流保護(hù)的漏電開(kāi)關(guān)。其余回路按其設(shè)備額定計(jì)算容量選取DZ20T100、DZ2060或DZ20T40透明外殼式斷路器,RCD選用帶過(guò)電路保護(hù)的漏電開(kāi)關(guān)(4)2#分配電箱總支線計(jì)算電流Ijs=66.39A,空氣短路額定電流Ie=1.3Ijs=86.31A.故選用DZ20T200透明外殼式斷路器,RCD選用帶過(guò)電流保護(hù)的漏電開(kāi)關(guān)。其余回路按其設(shè)備額定計(jì)算容量選取DZ20T100、DZ20T60或DZ20T40透明外殼式斷路器,RCD選用帶過(guò)電流保護(hù)的漏電開(kāi)關(guān)。(5)1#分配電箱總支線計(jì)算電流Ijs=89.83A,空氣短路額定電流Ie=1.3Ijs=116.78A.故選用DZ20T200透明外殼式斷路器,RCD選用帶過(guò)電流保護(hù)的漏電開(kāi)關(guān)。其余回路按其設(shè)備額定計(jì)算容量選取DZ20T100、DZ2060或DZ20T40透明外殼式斷路器,RCD選用帶過(guò)電路保護(hù)的漏電開(kāi)關(guān)(6)2#分配電箱總支線計(jì)算電流Ijs=61.81A,空氣短路額定電流Ie=1.3Ijs=80.35A.故選用DZ20T200透明外殼式斷路器,RCD選用帶過(guò)電流保護(hù)的漏電開(kāi)關(guān)。其余回路按其設(shè)備額定計(jì)算容量選取DZ20T100、DZ20T60或DZ20T40透明外殼式斷路器,RCD選用帶過(guò)電流保護(hù)的漏電開(kāi)關(guān)。2、 開(kāi)關(guān)箱接線與電器選擇開(kāi)關(guān)箱接線如附圖所示斷路器容量依據(jù)用電設(shè)備的工作電流選擇RCD選用DZ15LE系列帶過(guò)流和缺項(xiàng)保護(hù)的漏電開(kāi)關(guān),動(dòng)作電流在30mA以下,動(dòng)作時(shí)間為0.1s。3、 設(shè)計(jì)接地裝置重復(fù)接地裝置采用5050角鋼(如圖所示)制作埋設(shè)。因?yàn)楸竟こ淌┕^(qū)域土壤電阻率100/m以下,人工接地電阻應(yīng)小于10。接地電阻值可按下式計(jì)算:Rd=(p/2L)en (41/d) 式中 P=土壤電阻系數(shù) L=接地體的深度 對(duì)等邊角鋼d=0.84b(b為角鋼尺寸) 對(duì)扁鋼d=b/2(b為扁鋼寬度)Rd=(0.810/23.142580)en(42580/0.8450)=2.724、繪制電氣平面圖、立面圖和接線系統(tǒng)圖詳見(jiàn)附頁(yè)七、 設(shè)計(jì)防雷裝置依據(jù)現(xiàn)場(chǎng)勘測(cè),現(xiàn)場(chǎng)最高物體為塔吊,并且現(xiàn)場(chǎng)均在塔吊的保護(hù)范圍之內(nèi),故不另作避雷裝置。但必須在塔吊的地腳螺栓對(duì)角位置各設(shè)一組引下線。塔吊避雷保護(hù)半徑按下式計(jì)算:Ro=45(235-45)=33.54m八、 安全用電技術(shù)措施和防火措施1、 安全用電技術(shù)措施(1) 本工程臨時(shí)用電采用三級(jí)配電二級(jí)保護(hù),系統(tǒng)接地形式采用的TN-S系統(tǒng)。(2) 施工現(xiàn)場(chǎng)臨時(shí)用電管理、安裝、維護(hù)均執(zhí)行JGJ59-99施工現(xiàn)場(chǎng)安全檢查標(biāo)準(zhǔn)。(3) 電工必須嚴(yán)格遵守電工安全技術(shù)操作,取得特種作業(yè)資格證方可作業(yè)。嚴(yán)禁違章操作要認(rèn)真做好電氣線路、設(shè)備的檢查維修,及時(shí)排除故障和隱患。認(rèn)真做好巡視、檢查、維修記錄,電工必須配備必要的絕緣膠鞋、絕緣手套、工作服等勞保用品。(4) 現(xiàn)場(chǎng)臨時(shí)用電總配電箱采用重復(fù)接地,分別配出零線、保護(hù)零線送至分配電箱。(5) 總配電箱、分配電箱、開(kāi)關(guān)箱均做重復(fù)接地。(6) 現(xiàn)場(chǎng)臨時(shí)用電重復(fù)接地電阻不大于10。(7) 施工現(xiàn)場(chǎng)的電氣設(shè)備金屬外殼全部采用保護(hù)接零。(8) 施工現(xiàn)場(chǎng)的配電電纜采用地埋(架空)敷
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年飛機(jī)液壓檢查凈化設(shè)備項(xiàng)目規(guī)劃申請(qǐng)報(bào)告
- 2025年度環(huán)境監(jiān)理合同范本環(huán)保監(jiān)理項(xiàng)目風(fēng)險(xiǎn)評(píng)估
- 2025年度婚慶場(chǎng)地租賃與婚禮現(xiàn)場(chǎng)特色裝飾服務(wù)合同范本
- 公司宿舍租賃合同
- 網(wǎng)絡(luò)編程開(kāi)發(fā)規(guī)范與編程技巧分享
- 項(xiàng)目工作規(guī)劃與管理計(jì)劃
- 廁所清理合同協(xié)議
- 2025年度租賃房屋租賃期限調(diào)整合同范本
- 新能源汽車產(chǎn)業(yè)鏈運(yùn)行機(jī)制研究
- 個(gè)人和公司之間借款協(xié)議
- 北京市房山區(qū)2024-2025學(xué)年七年級(jí)上學(xué)期期末英語(yǔ)試題(含答案)
- 安全生產(chǎn)事故調(diào)查與案例分析(第3版)課件 呂淑然 第5、6章 事故案例評(píng)析、相關(guān)法律法規(guī)
- 2025年南陽(yáng)科技職業(yè)學(xué)院高職單招數(shù)學(xué)歷年(2016-2024)頻考點(diǎn)試題含答案解析
- 加油站復(fù)工復(fù)產(chǎn)方案
- 2025-2030年中國(guó)增韌劑(MBS高膠粉)行業(yè)發(fā)展現(xiàn)狀及前景趨勢(shì)分析報(bào)告
- 2025年高考物理復(fù)習(xí)新題速遞之萬(wàn)有引力與宇宙航行(2024年9月)
- 2025年首都機(jī)場(chǎng)集團(tuán)公司招聘筆試參考題庫(kù)含答案解析
- 2025云南省貴金屬新材料控股集團(tuán)限公司面向高校畢業(yè)生專項(xiàng)招聘144人高頻重點(diǎn)提升(共500題)附帶答案詳解
- 蘇州市區(qū)2024-2025學(xué)年五年級(jí)上學(xué)期數(shù)學(xué)期末試題一(有答案)
- 暑期預(yù)習(xí)高一生物必修二知識(shí)點(diǎn)
- (高清版)DB43∕T 1147-2015 太陽(yáng)能果蔬烘干機(jī)
評(píng)論
0/150
提交評(píng)論