,D-FMEA,,,,(DESIGNFMEAaccordingtoAIAGstandard),,,,,,,,,,,,,,,,,,,,

,,,,,,System,,Subsystem,,Component,,,,,,,,,,,,,,,

,,,,,,,,,,,,,,,,,,,,,,,,,,

,PartNo.,,Partname,,,Drawing(No.&issue),,,,Customer,,,,,,,FMEA(No.&issue),,,,,,,,

,1000592442V03,,CMG2PCBAssembly,,,HighLevel,,,,Internal,,,,,,,10006324207v01,,,,,,,,

,Project(No.&name),,,,,Keydate(finishdate),,Date(firstissue),,Date(thisrevision),,,,,,,S-Severity/Allvarlighetsgrad,,,,,,,,

,104191-GenericshifterconceptCMG2,,,,,15-03-2015,,04-12-2014,,24-02-2015,,,,,,,O-Occurency/Felintensitet,,,,,,,,

,Issuedby,,,Dept./BA,,Participants,,,,,,,,,,,D-Detection/Uppt?cktssannolikhet,,,,,,,,

,DanielFransson,,,COE,,Seeparticipantssheet,,,,,,,,,,,RPN-RiskPriorityNumber/Risktal,,,,,,,,

,,,,,,,,,,,,,,,,,,,,,,,,,,

,PART/FUNCTION,,CHARACTERISTICSOFPOTENTIALFAILURES,,,,,,CONTROL,,,,,,,,Action,,,,,RESULT,,,

,Pos,Partname,Potential,Potential,,(KPC),Potential,,Prevention,Prevention,Prevention,Detection,Detection,Detection,,,Actionfor,Actionfor,,Due,Performed,,,,

,No.,anditsfunction,Failuremode,Effectoffailure,S,Class,Causesoffailure,O,"Control(current)

","Implementation

responsible","Implementation

Date","Control(current)

","Implementation

responsible","Implementation

Date",D,RPN,Prevention,Detection,Resp.,Date,Date,S,O,D,RPN

,,Connector,,,,,,,,,,,,,,,,,,,,,,,

,,Connector,TooHighCurrent,Connectorburning,9,,Connectorratingstoolowcomparedtofuseratings,3,"Verifyconnectorratingandderatingintemperaturewhendesigning,Ensureitismatchedwiththefusefromthecar",DanielFransson,,DVtesting,Bernt-OveHansson,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,,,,9,3,,

,,,,,9,,Shortbetweenpins,3,Reviewconnectorchoice,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,9,3,,

,,KL30,PoorConnection,NoorInterruptedPower,8,,Badsoldering,3,"Ensuresolderpastmaskistherightthickness,useKongsbergVaultcomponentswhendesigningtoensurethePasteMaskExpansionfollowsIPCstandards/isvalidatedinproduction",DanielFransson,2015-02-10,Verifythefirstboardswhenwereceivethem,DanielFransson,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,,,8,,Oxide,4,Rightchoiceofmaterial/connector,DanielMartensson,,,,,,,Consultcomponentspecialistwhenchoosingconnector,NoAction,,,,8,4,,

,,,,,8,,Tolerancesofterminals,2,Choiceofterminalisaccordingtoconnectormanufacturerspecs,DanielMartensson,,DVtesting,Bernt-OveHansson,,,,Consultcomponentspecialistwhenchoosingconnector,NoAction,,,,8,2,,

,,,,,8,,Vibration,3,Rightchoiceofconnector,DanielMartensson,,DVtesting,Bernt-OveHansson,,,,Consultcomponentspecialistwhenchoosingconnector,NoAction,,,,8,3,,

,,,,,8,,BadPCBRouting,2,Designmustbereviewedbeforemanufacturing,DanielFransson,2015-02-10,DVtesting,Bernt-OveHansson,,,,Consultcomponentspecialistwhenchoosingconnector,NoAction,DanielFransson,,2015-02-10,8,2,,

,,,Shorttoground,Toohighcurrentflowingthroughconnector,8,,Waterintrusion,3,Correctchoiceofconnector.Useconformalcoating.,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Conductivematerialintrusion,3,Correctchoiceofconnector.Useconformalcoating.,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,Shorttoacommunicationsignalpin,Noiseinducedonpowerline,5,,Waterintrusion,3,Correctchoiceofconnector.Useconformalcoating.,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,5,3,,

,,,,,5,,Conductivematerialintrusion,3,Correctchoiceofconnector.Useconformalcoating.,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,5,3,,

,,,,,5,,Electromigration,3,MakesurethePCBmanufacturerfollowsIPCstandardsandisautomotivequalified,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,5,3,,

,,KL15,PoorConnection,NoorInterruptedPower,8,,Badsoldering,3,"Ensuresolderpastmaskistherightthickness,useKongsbergVaultcomponentswhendesigningtoensurethePasteMaskExpansionfollowsIPCstandards/isvalidatedinproduction",DanielFransson,2015-02-10,Verifythefirstboardswhenwereceivethem,DanielFransson,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,,,8,,Oxide,4,Rightchoiceofmaterial/connector,DanielMartensson,,,,,,,Consultcomponentspecialistwhenchoosingconnector,Noaction,,,,8,4,,

,,,,,8,,Tolerancesofterminals,2,Choiceofterminalisaccordingtoconnectormanufacturerspecs,DanielMartensson,,DVtesting,Bernt-OveHansson,,,,Consultcomponentspecialistwhenchoosingconnector,Noaction,,,,8,2,,

,,,,,8,,Vibration,3,Rightchoiceofconnector,DanielMartensson,,DVtesting,Bernt-OveHansson,,,,Consultcomponentspecialistwhenchoosingconnector,Noaction,,,,8,3,,

,,,,,8,,BadPCBRouting,3,Designmustbereviewedbeforemanufacturing,DanielFransson,2015-02-10,DVtesting,Bernt-OveHansson,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,Shorttoground,Toohighcurrentflowingthroughconnector,8,,Waterintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Conductivematerialintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,Shorttoacommunicationsignalpin,Noiseinducedonpowerline,5,,Waterintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,5,3,,

,,,,,5,,Conductivematerialintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,5,3,,

,,,,,5,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,5,3,,

,,,ShorttoKL30,Ignitionfeaturenotfunctionnalanymore,6,,Waterintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,6,3,,

,,,,,6,,Conductivematerialintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,6,3,,

,,,,,6,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,6,3,,

,,,,Batterywilldrainoff,8,,Waterintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Conductivematerialintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,Wake,PoorConnection,NoorInterruptedPower,8,,Badsoldering,3,"Ensuresolderpastmaskistherightthickness,useKongsbergVaultcomponentswhendesigningtoensurethePasteMaskExpansionfollowsIPCstandards/isvalidatedinproduction",DanielFransson,2015-02-10,Verifythefirstboardswhenwereceivethem,DanielFransson,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,,,8,,Oxide,4,Rightchoiceofmaterial/connector,DanielMartensson,,,,,,,Consultcomponentspecialistwhenchoosingconnector,Noaction,,,,8,4,,

,,,,,8,,Tolerancesofterminals,2,Choiceofterminalisaccordingtoconnectormanufacturerspecs,DanielMartensson,,DVtesting,Bernt-OveHansson,,,,Consultcomponentspecialistwhenchoosingconnector,Noaction,,,,8,2,,

,,,,,8,,Vibration,3,Rightchoiceofconnector,DanielMartensson,,DVtesting,Bernt-OveHansson,,,,Consultcomponentspecialistwhenchoosingconnector,Noaction,,,,8,3,,

,,,,,8,,BadPCBRouting,3,Designmustbereviewedbeforemanufacturing,DanielFransson,2015-02-10,DVtesting,Bernt-OveHansson,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,Shorttoground,Wake-upfeaturenotfunctionnal/Toohighcurrentflowingthroughconnector,8,,Waterintrusion,3,Mechanicalhousingisdesignedtopreventintrusionofunwantedmaterial/substancesonthePCB/Useconformalcoatingifneeded,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Conductivematerialintrusion,3,Mechanicalhousingisdesignedtopreventintrusionofunwantedmaterial/substancesonthePCB/Useconformalcoatingifneeded,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,Shorttoacommunicationsignalpin,Wake-upfeatureoscillating,7,,Waterintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,7,3,,

,,,,,7,,Conductivematerialintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,7,3,,

,,,,,7,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,7,3,,

,,,ShorttoKL30,Wake-upfeaturealwayson/notfunctionnalanymore,6,,Waterintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,6,3,,

,,,,,6,,Conductivematerialintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,6,3,,

,,,,,6,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,6,3,,

,,LIN,PoorConnection,LossorInterruptedCommunication,8,,Badsoldering,3,"Ensuresolderpastmaskistherightthickness,useKongsbergVaultcomponentswhendesigningtoensurethePasteMaskExpansionfollowsIPCstandards/isvalidatedinproduction",DanielFransson,2015-02-10,Verifythefirstboardswhenwereceivethem,DanielFransson,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,,,8,,Oxide,4,Rightchoiceofmaterial/connector,DanielMartensson,,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,,,,8,4,,

,,,,,8,,Tolerancesofterminals,2,Choiceofterminalisaccordingtoconnectormanufacturerspecs,DanielMartensson,,DVtesting,Bernt-OveHansson,,,,Consultcomponentspecialistwhenchoosingconnector,Noaction,,,,8,2,,

,,,,,8,,Vibration,3,Rightchoiceofconnector,DanielMartensson,,DVtesting,Bernt-OveHansson,,,,Consultcomponentspecialistwhenchoosingconnector,Noaction,,,,8,3,,

,,,,,8,,BadPCBRouting,3,Designmustbereviewedbeforemanufacturing,DanielFransson,2015-02-10,DVtesting,Bernt-OveHansson,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,Shorttoground,LINbusnotfunctionnal/Toohighcurrentflowingthroughconnector,8,,Waterintrusion,3,Correctchoiceofconnector.,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Conductivematerialintrusion,3,Correctchoiceofconnector.,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,Shorttoacommunicationsignalpin,LINbusnotfunctionnal,8,,Waterintrusion,3,"UseconformalcoatingonPCBA.

Correctchoiceofconnector.",DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Conductivematerialintrusion,3,"UseconformalcoatingonPCBA.

Correctchoiceofconnector.",DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,ShorttoKL30,LINbusnotfunctionnal,8,,Waterintrusion,3,"UseconformalcoatingonPCBA.

Correctchoiceofconnector.",DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Conductivematerialintrusion,3,"UseconformalcoatingonPCBA.

Correctchoiceofconnector.",DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,GND,PoorConnection,Noorfloatingground,8,,Badsoldering,3,"Ensuresolderpastmaskistherightthickness,useKongsbergVaultcomponentswhendesigningtoensurethePasteMaskExpansionfollowsIPCstandards/isvalidatedinproduction",DanielFransson,2015-02-10,Verifythefirstboardswhenwereceivethem,DanielFransson,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,,,8,,Oxide,3,Rightchoiceofmaterial/connector,DanielMartensson,,,,,,,Consultcomponentspecialistwhenchoosingconnector,Noaction,,,,8,3,,

,,,,,8,,Tolerancesofterminals,2,Choiceofterminalisaccordingtoconnectormanufacturerspecs,DanielMartensson,,DVtesting,Bernt-OveHansson,,,,Consultcomponentspecialistwhenchoosingconnector,Noaction,,,,8,2,,

,,,,,8,,Vibration,3,Rightchoiceofconnector,DanielMartensson,,DVtesting,Bernt-OveHansson,,,,Consultcomponentspecialistwhenchoosingconnector,Noaction,,,,8,3,,

,,,,,8,,BadPCBRouting,3,Designmustbereviewedbeforemanufacturing,DanielFransson,2015-02-10,DVtesting,Bernt-OveHansson,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,Shorttoacommunicationsignalpin,Noiseinducedintheground/toomuchcurrentinconnector,8,,Waterintrusion,3,"UseconformalcoatingonPCBA.

Correctchoiceofconnector.",DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Conductivematerialintrusion,3,UseconformalcoatingonPCBA.Correctchoiceofconnector.,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,,DanielFransson,,2015-02-10,8,3,,

,,,Shorttopower/wake-uppin,Toohighcurrentinconnector,8,,Waterintrusion,3,UseconformalcoatingonPCBA.Correctchoiceofconnector.,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Conductivematerialintrusion,3,"UseconformalcoatingonPCBA.

Correctchoiceofconnector.",DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,CAN-HIGH,PoorConnection,NoorInterruptedCommunication,8,,Badsoldering,3,"Ensuresolderpastmaskistherightthickness,useKongsbergVaultcomponentswhendesigningtoensurethePasteMaskExpansionfollowsIPCstandards/isvalidatedinproduction",DanielFransson,2015-02-10,Verifythefirstboardswhenwereceivethem,DanielFransson,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,,,8,,Oxide,3,Rightchoiceofmaterial/connector,DanielMartensson,,,,,,,Consultcomponentspecialistwhenchoosingconnector,Noaction,,,,8,3,,

,,,,,8,,Tolerancesofterminals,2,Choiceofterminalisaccordingtoconnectormanufacturerspecs,DanielMartensson,,DVtesting,Bernt-OveHansson,,,,Consultcomponentspecialistwhenchoosingconnector,NoAction,,,,8,2,,

,,,,,8,,Vibration,3,Rightchoiceofconnector,DanielMartensson,,DVtesting,Bernt-OveHansson,,,,Consultcomponentspecialistwhenchoosingconnector,NoAction,,,,8,3,,

,,,,,8,,BadPCBRouting,3,Designmustbereviewedbeforemanufacturing,DanielFransson,2015-02-10,DVtesting,Bernt-OveHansson,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,Shorttopower/wake-uppin,CANbusnotworking,8,,Waterintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Conductivematerialintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,Shorttoothercommunicationpin,CANbusnotworking,8,,Waterintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Conductivematerialintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,CAN-LOW,PoorConnection,NoorInterruptedCommunication,8,,Badsoldering,3,"Ensuresolderpastmaskistherightthickness,useKongsbergVaultcomponentswhendesigningtoensurethePasteMaskExpansionfollowsIPCstandards/isvalidatedinproduction",DanielFransson,2015-02-10,Verifythefirstboardswhenwereceivethem,DanielFransson,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,,,8,,Oxide,3,Rightchoiceofmaterial/connector,DanielMartensson,,,,,,,Consultcomponentspecialistwhenchoosingconnector,NoAction,,,,8,3,,

,,,,,8,,Tolerancesofterminals,2,Choiceofterminalisaccordingtoconnectormanufacturerspecs,DanielMartensson,,DVtesting,Bernt-OveHansson,,,,Consultcomponentspecialistwhenchoosingconnector,NoAction,,,,8,2,,

,,,,,8,,Vibration,3,Rightchoiceofconnector,DanielMartensson,,DVtesting,Bernt-OveHansson,,,,Consultcomponentspecialistwhenchoosingconnector,NoAction,,,,8,3,,

,,,,,8,,BadPCBRouting,3,Designmustbereviewedbeforemanufacturing,DanielFransson,2015-02-10,DVtesting,Bernt-OveHansson,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,Shorttopower/wake-uppin,CANbusnotworking,8,,Waterintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Conductivematerialintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,,Shorttoothercommunicationpin,CANbusnotworking,8,,Waterintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Conductivematerialintrusion,3,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,3,,

,,,,,8,,Electromigration,3,MakesurePCBmanufacturerfollowsIPCstandards,DanielFransson,2015-02-10,,,,,,FollowIPCandKAguidelinesregardingPCBmanufacturing,VisualinspectionwhenreceivingthefirstPCBassemblies,DanielFransson,,2015-02-10,8,3,,

,,PowerSupply,,,,,,,,,,,,,,,,,,,,,,,

,,Deliver5V,TooHighVoltage,Breakcomponentsandlossofprimaryfunction,8,,Shortcircuitbetweeninputandoutputofregulator,1,UseconformalcoatingonPCBA,DanielFransson,,DVtesting,Bernt-OveHansson,,,,Testinlab,Dointegrationtestsearly,,,,8,1,,

,,,TooLowVoltage,lossofprimaryfunctionorUnexpectedbehaviorduetounknownlogicstate,9,,Opencircuitinpowerdeliverychain,2,ImplementadequateuClowvoltagereset,DanielFransson,2015-02-10,DVtesting,Bernt-OveHansson,,,,Runsimulationstoseethebehaviorofthepowersupply,RunelectricaltestinginlabBEFOREgoingtoDVtestingandpushtheboarduntilitbreakstoseeitslimits,DanielFransson,,2015-02-10,9,2,,

,,,,,9,,Toohighloadatoutput,3,ImplementadequateuClowvoltagereset,DanielFransson,2015-02-10,,,,,,Runsimulationstoseethebehaviorofthepowersupply,RunelectricaltestinginlabBEFOREgoingtoDVtestingandpushtheboarduntilitbreakstoseeitslimits,DanielFransson,,2015-02-10,9,3,,

,,,,,9,,Shortcircuittogroundonoutput,3,ImplementadequateuClowvoltagereset,DanielFransson,2015-02-10,DVtesting,Bernt-OveHansson,,,,Runsimulationstoseethebehaviorofthepowersupply,RunelectricaltestinginlabBEFOREgoingtoDVtestingandpushtheboarduntilitbreakstoseeitslimits,DanielFransson,,2015-02-10,9,3,,

,,,,,9,,Shortcircuittogroundatinput,3,ImplementadequateuClowvoltagereset,DanielFransson,2015-02-10,DVtesting,Bernt-OveHansson,,,,Runsimulationstoseethebehaviorofthepowersupply,RunelectricaltestinginlabBEFOREgoingtoDVtestingandpushtheboarduntilitbreakstoseeitslimits,DanielFransson,,2015-02-10,9,3,,

,,,,,9,,Incorrectinputfromcar,3,ImplementadequateuClowvoltagereset,DanielFransson,2015-02-10,DVtesting,Bernt-OveHansson,,,,Runsimulationstoseethebehaviorofthepowersupply,RunelectricaltestinginlabBEFOREgoingtoDVtestingandpushtheboarduntilitbreakstoseeitslimits,DanielFransson,,2015-02-10,9,3,,

,,,Unstablevoltageoutput,Breakcomponentsandlossofprimaryfunction,8,,Toobigloadatoutput,3,Reviewdesignofschematic,DanielFransson,2015-02-10,,,,,,Runsimulationstoseethebehaviorofthepowersupply,RunelectricaltestinginlabBEFOREgoingtoDVtestingandpushtheboarduntilitbreakstoseeitslimits,DanielFransson,,2015-02-10,8,3,,

,,,,,8,,Wrongchoiceofcomponents,3,Reviewdesignofschematic,DanielFransson,2015-02-10,DVtesting,Bernt-OveHansson,,,,Runsimulationstoseethebehaviorofthepowersupply,RunelectricaltestinginlabBEFOREgoingtoDVtestingandpushtheboarduntilitbreakstoseeitslimits,DanielFransson,,2015-02-10,8,3,,

,,,,,8,,Frequencyandamplitudeofoutputcurrent,7,Simulation/Calculationtoverify/validatedesign,DanielFransson,2015-02-10,DVtesting,Bernt-OveHansson,,,,Runsimulationstoseethebehaviorofthepowersupply,RunelectricaltestinginlabBEFOREgoingtoDVtestingandpushtheboarduntilitbreakstoseeitslimits,DanielFransson,,2015-02-10,8,7,,

,,,,Unexpectedbehaviorduetounknownlogicstate,9,,Toobigloadatoutput,3,ImplementadequateuClowvoltagereset,DanielFransson,2015-02-10,,,,,,Runsimulationstoseethebehaviorofthepowersupply,RunelectricaltestinginlabBEFOREgoingtoDVtestingandpushtheboarduntilitbreakstoseeitslimits,DanielFransson,,2015-02-10,9,3,,

,,,,,9,,Wrongchoiceofcomponents,3,ImplementadequateuClowvoltagereset,DanielFransson,2015-02-10,DVtesting,Bernt-OveHansson,,,,Runsimulationstoseethebehaviorofthepowersupply,RunelectricaltestinginlabBEFOREgoingtoDVtestingandpushtheboarduntilitbreakstoseeitslimits,DanielFransson,,2015-02-10,9,3,,

,,,,,9,,Frequencyandamplitudeofoutputcurrent,7,ImplementadequateuClowvoltagereset,DanielFransson,2015-02-10,DVtesting,Bernt-OveHansson,,,,Runsimulationstoseethebehavi

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

最新文檔

評(píng)論

0/150

提交評(píng)論