AS2047—1999

AS2047

(IncorporatingAmendmentNos1and2)

AustralianStandard?

BuildingCodeofAustraliaprimaryreferencedStandard

Windowsinbuildings—Selectionandinstallation

ThisAustralianStandardwaspreparedbyCommitteeBD/21,Windows.ItwasapprovedonbehalfoftheCouncilofStandardsAustraliaon30April1999andpublishedon5June1999.

ThefollowinginterestsarerepresentedonCommitteeBD/21:ArchitecturalAluminiumFabricatorsAssociationAustralianAluminiumCouncil

AustralianBuildingCodesBoard

ConstructionIndustryEngineeringServicesGroupCSIROBuilding,ConstructionandEngineering

FlatGlassandAluminiumAssociationofQueenslandFlatGlassCouncilofAustralia

HousingIndustryAssociationInstitutionofEngineersAustraliaMasterBuildersAustralia

MetalTradesIndustryAssociationofAustraliaNationalAssociationofTestingAuthoritiesAustraliaPlasticsandChemicalsIndustriesAssociationResidentialWindowAssociation

UniversityofNewSouthWales

KeepingStandardsup-to-date

Standardsarelivingdocumentswhichreflectprogressinscience,technologyandsystemsTomaintaintheircurrency,allStandardsareperiodicallyreviewed,andneweditionsarepublished.Betweeneditions,amendmentsmaybeissued.Standardsmayalsobewithdrawn.ItisimportantthatreadersassurethemselvestheyareusingacurrentStandard,whichshouldincludeanyamendmentswhichmayhavebeenpublishedsincetheStandardwaspurchased.

DetailedinformationaboutStandardscanbefoundbyvisitingtheStandardsAustraliawebsiteat

.au

andlookinguptherelevantStandardintheon-linecatalogue.

Alternatively,theprintedCatalogueprovidesinformationcurrentat1Januaryeachyear,andthemonthlymagazine,TheAustralianStandard,hasafulllistingofrevisionsandamendmentspublishedeachmonth.

WealsowelcomesuggestionsfortheimprovementinourStandards,andespeciallyencouragereaderstonotifyusimmediatelyofanyapparentinaccuraciesorambiguities.Contactusviaemailat

mail@.au,

orwritetotheChiefExecutive,StandardsAustraliaInternationalLtd,POBox5420,Sydney,NSW2001.

ThisStandardwasissuedindraftformforcommentasDR98349.

AS2047—1999

(IncorporatingAmendmentNos1and2)

AustralianStandard?

Windowsinbuildings—Selectionandinstallation

OriginatedinpartaspartofSAAInt.318—1951.FinaleditionAS2147—1996andAS2147.2—1996.

AS2047.1—1996andAS2047.2—1996revised,

amalgamatedandredesignatedAS2047—1999.ReissuedincorporatingAmendmentNo.1(January2001).ReissuedincorporatingAmendmentNo.2(June2001).

COPYRIGHT

?StandardsAustraliaInternational

Allrightsarereserved.Nopartofthisworkmaybereproducedorcopiedinanyformorbyanymeans,electronicormechanical,includingphotocopying,withoutthewrittenpermissionofthepublisher.

PublishedbyStandardsAustraliaInternationalLtdGPOBox5420,Sydney,NSW2001,Australia

ISBN0733727204

AS2047—1999

PAGE

2

PAGE

3

AS2047—1999

PREFACE

ThisStandardwaspreparedbytheJointStandardsAustralia/StandardsNewZealandCommitteeBD/21,Windows,tosupersede,AS2047.1—1996,Windowsinbuildings,Partl:SpecificationformaterialsandperformanceandAS2047.2—1996,Windowsinbuildings—Part2:Construction,installationandmaintenance.Afterallowingsufficienttimeforadjustment(nominally12monthsfrompublication),thesupersededdocumentswillbewithdrawn.

ThisStandardincorporatesAmendmentNo.l(January200l)andAmendmentNo.2(June200l).ThechangesarisingfromtheAmendmentsareindicatedinthetextbyamarginalbarandamendmentnumberagainsttheclause,note,table,figure,orpartthereofaffected.

ThisStandardistheresultofaconsensusamongAustralianandNewZealandrepresentativesontheJointCommitteetoproduceitasanAustralianStandard.

TheobjectiveofthisStandardistoprovidewindowdesignersandmanufacturerswithagenericwindowcode,settingouttheperformancerequirementsandspecificationsinthedesignandmanufactureofallwindows,regardlessofmaterials.

ThisStandardhasbeenrevisedtomakeitsuitableforreferenceintheBuildingCodeofAustralia(BCA)asaStandardforregulatoryreference.

Thewindowratingsystemisasimplifiedsystemandwindowsspecificallydesignedforcornershavebeenomitted(seeAppendixA).

Theeffectsofatmosphericenvironments(corrosionandweathering)onmaterialsusedinwindowassembliesiscurrentlybeingconsideredbytheCommitteemembersforimprovementandinclusioninthenextrevision.

InthisStandard,statementexpressedinmandatorytermsinnotestotablesaredeemedtobeanintegralpartoftheStandard.

Theterm‘informative’hasbeenusedinthisStandardtodefinetheapplicationoftheappendixtowhichitapplies.An‘informative’appendixisonlyforinformationandguidance.

CONTENTS

Page

SECTION1SCOPEANDGENERAL

SCOPE 5

APPLICATION 6

REFERENCEDDOCUMENTS 6

DEFINITIONS 6

SECTION2PERFORMANCE

GENERAL 8

ATMOSPHERICENVIRONMENTS 8

WINDOWPERFORMANCE 8

VERIFICATIONOFSMALLERORLARGERSIZEPRODUCTS 13

USEANDRATINGOFWINDOWCOUPLINGSYSTEMS 14

SECTION3FRAMINGANDFINISHES

ALUMINIUMWINDOWS 15

TIMBERWINDOWS 16

UNPLASTICIZEDPVC(UPVC)WINDOWS 19

WINDOWSOFOTHERMATERIALS 19

SECTION4GLAZING

GENERAL 21

GLASS 21

GLAZINGMATERIALS 21

SECTION5COMPONENTS

HARDWARE 22

FASTENERS 22

WEATHERPROOFING 22

SECURITY 22

ANCHORINGDEVICES 22

SECTION6CONSTRUCTION

GENERAL 24

TOLERANCES 24

JOINTS 24

GLAZING 24

REVEALLININGS 24

FLASHINGS 24

SECTION7INSTALLATION

WINDOWSELECTION 25

INSTALLATION 25

THERMALANDSTRUCTURALMOVEMENT 25

ON-SITECARE 25

Page

SECTION8LABELLINGANDCERTIFICATE

8.1 GENERAL..............................................

26

8.2 LABELLING.............................................

26

8.3 CERTIFICATE...........................................

26

APPENDICES

A

GUIDETODESIGNWINDPRESSURE...........................

27

B

MEANSFORDEMONSTRATINGCOMPLIANCEWITHTHISSTANDARD

30

C

REFERENCEDDOCUMENTS..................................

32

D

NOMINATIONOFWINDOWRATINGSANDDESIGNWINDPRESSURE.

34

E

SURFACEFINISHFORALUMINIUM...........................

35

F

ON-SITECARE............................................

37

A1

G

GENERICTIMBERWINDOWS................................

38

A2

H

GENERICWINDOWSTESTRESULTS...........................

55

PAGE

11

AS2047—1999

AS2047—1999

PAGE

10

.au

?StandardsAustralia

?StandardsAustralia

.au

STANDARDSAUSTRALIA

AustralianStandard

Windowsinbuildings—Selectionandinstallation

SECTION 1 SCOPE AND GENERAL

SCOPE ThisStandardspecifiesrequirements,materials,construction,installationandglazingfor—

windows;

slidingglazeddoors;

A1 (c) adjustablelouvres;

shopfronts;and

windowwallswithone-pieceframingelements.

NOTE:Windowwallsdonotincludecurtainwallsusingstackedorverticallysplicedframingsystems,manufacturedfromanymaterialandinstalledinexternalwallsofallclassesofbuildings.

Throughoutthisstandardtheterm‘window(s)’meanswindowofanytype,includinglouvre(s)andslidingdoor(s).

NOTES:

Thewindowratings,orclassifications,differfrompreviousglassandwindowStandardsduetothemoreaccurateevaluationoftheeffectofwindconditions.TheyarebasedoneitherAS1170.2,orthespecificwindloadingcodedevelopedforhousing,i.e.AS4055.

SeeAppendixAforinformationonwindloadsapplicabletowindowscoveredbythisStandard.

SeeAppendixBforalternativemeansofdemonstratingcompliancewiththisStandard.

Prefabricatedbaywindowsthatincorporateslopedglassareclassifiedaswindowsinexternalwalls.

RefertoAS/NZS4284forperformancespecificationofbuildingfacade.ConformancetotherequirementsinAS/NZS4284willbedeemedtosatisfytherequirementsofthisStandard.However,slidingwindowsashesordoorswillrequiretheoperatingforcetestinaccordancewithAS4420.3.

A1, 6ThefollowingarenotcoveredbythisStandard:

A2 (a)Hingeddoors,includingFrenchandbi-folddoors.

Revolvingglazeddoors.

Fixedlouvres.

Skylightsandrooflightsandwindowsinotherthantheverticalplane.

Windowsingreenhousesandagriculturalbuildings.

Slidingdoorswithoutframessuchasinternaldoorsandshopfrontdoors.

Windowsconstructedonsiteandarchitecturalone-offwindows,whicharenotdesigntested.

Second-handwindows,re-usedwindows,replacementwindows,orrecycledwindows.

Heritagewindows,forheritagebuildingsasdefinedbytherelevantStateorTerritoryauthority.

APPLICATIONThisStandardwillbereferencedintheBuildingCodeofAustraliabywayofBCAAmendmentNo.5tobepublishedby1July1999.

REFERENCEDDOCUMENTSThedocumentsreferredtointhisStandardarelistedinAppendixC.

DEFINITIONSForthepurposeofthisStandard,thedefinitionsgiveninAS\NZS4491andthosebelowapply.

Curtainwall—anon-load-bearingwindowwallthatisnotapanelwall.

Door—aslidingsashofasizesuitableforuseasaccessthroughwalls.

Fenestration—thearrangementofwindowsandotheropeningsontheexternalwallsofbuildings,especiallythefacade.

Fin—apieceofglasspositionedsuchastoprovidelateralsupport.

Fixing—anyitemthatisusedtosecuremembersofawindowassemblytoeachother,tosecureanitemofhardwaretoawindowmember,ortosecureacompletedwindowassemblyintothebuildingstructure.

Flashing—animperviousmembraneinstalledinsuchamannerastopreventingressofwaterintothebuilding.

Frame—thatpartofawindowassemblysurroundingthesashesorfixedglazing.Itisanassemblymanufacturedfromtimber,metal,glass,orotherdurablematerialorcombinationsofmaterials,suchasglassfinsandstructuralsealantformingpartoftheassemblyofaglazedpanelandsupportingthefulllengthofalltheedgesoftheglass.

NOTE:Butt-jointedglasspanelsthatarenotinthesameplanecansatisfytherequirementsforframes.

Glass—ahard,brittle,amorphoussubstanceproducedbyfusionandusuallyconsistingofmutuallydissolvedsilicaorsilicatesthatalsocontainsodaandlime.Itmaybetransparent,translucentoropaque.

Glazingbar—amemberthatisaddedtoastandardwindowconstructiontochangetheappearanceofthewindow.Itcanbeintheforminwhichtheglassisglazed,clipped,orstuckontoeitherorbothfacesoftheglass.

Glazinggasket—plasticorsyntheticrubbermembers,usedbetweentheglassandtheframeortheglassandthebead.

Hardware—equipmentusedintheopening,operating,closing,lockingandstoppingofsashes.

Head—thetophorizontalframingmemberofawindowassembly.

Jamb—averticalsideframingmember.

Light—seewindowlight.

Louvre—awindowunitcomprisingaseriesofbladesofglass,orothermaterial,lappingeachother.

Meetingstiles—verticalintermediatesashmembersthatmeetwhenthewindowisclosedsuchthattheycombinetoactinunison.

Meetingrails—horizontalintermediatesashmembersthatmeetwhenthewindowisclosedsuchthattheycombinetoactinunison

Mullion—averticalintermediateframingmember.

Multi-lightwindow—awindowincorporatingmorethanoneopeningorfixedlight,orboth,withinoneperimeterframe,aslowlights,highlightsorsidelights.

Newton—theforcewhich,whenappliedtoabodyhavingamassofonekilogram,causesanaccelerationofonemetrepersecondsquaredinthedirectionofapplicationoftheforce.

Panelwall—anon-load-bearingwindowwallthatiswhollysupportedateachstorey.

Pascal(Pa)—thepressureorstressthatariseswhenaforceofonenewtonisapplieduniformlyoveranareaofonesquaremetre.

Reveal—thevisiblepartofeachsideofawindowopeningnotcoveredbytheframe,ortherecessbetweentheframeandthefaceofthewall.

Sash—theseparateframe,toawindow,carryingtheglass.Itmaybefixed(inoperable)ormovable(operable).

A11.4.25 Sill—thebottomhorizontalframingmemberofawindowassembly.

Stile,sash—averticalsidememberofasash.

Structuralmembers—theelements,includingmullions,transoms,meetingrails,andmeetingstiles,thatperformthefunctionoftransferringloadstotheperimeterframe.

NOTE:Glazingbars,awningandcasementsashstilesandrailsarenotconsideredstructural

A1 membersforhousing;however,theyareconsideredstructuralmembersforresidentialandcommercialbuildings.

Transom—ahorizontalintermediateframingmemberofawindowassembly.

Weatherseal—amaterialincludedinawindowassemblytoreducetheairinfiltrationorimproveresistancetowaterpenetration.

Wind—displacementofparallelmemberswithrespecttooneanother.

Windowassembly—acompleteunitcomprisingframe,couplings,sashes,glazinginfillpanelsandhardware.

Windowlight—asinglepanelorglazinginawindowassembly.

Windowrating—aclassificationsystemprovidingforwindowstobetestedtodeterminetheirlevelofperformanceforstrengthandweatherproofness.Windowratingsforhousingareexpressedinwindclassificationterms(seeTable2.1),andwindowratingsforbuildingsotherthanhousingareexpressedinpermissibleorlimitstatedesignwindpressureterms.

Windowwall—aseriesofmulti-lightwindows,generallyspanningfromfloortoceiling,andoftencontinuoushorizontally.

SECTION 2 PERFORMANCE

GENERALThisSectiondetailsperformancecriteriaforwindowassembliesthatareclassifiedbyaratingsystemforhousing,andbydesignwindpressuresforresidentialandcommercialbuildings.

NOTES:

TheperformancelevelsofwindowsgiveninthisSectionaretheresultofmanyyearsoftestingunitsinlaboratoriesandtheevaluationofbuildingsitesafterhighwindsandcyclonesinvariousregionsofAustralia.

Thewindowratings,orclassifications,differfrompreviousglassandwindowStandardsduetothemoreaccurateevaluationoftheeffectofthesewindconditions.TheyarebasedoneitherAS1170.2,orthespecificwindloadingcodedevelopedforhousing,i.e.AS4055.

A12.1.1GenerictimberwindowsWindowsmadetothedetailsinAppendixGaredeemedtocomplywiththeappropriatestructuralperformanceandwaterpenetrationrequirementsofClause2.3.

NOTE:TheobjectiveofincludingthegenerictimberwindowsintheStandard,asanacceptablealternativetoindividualtestingofspecificfabricatorproducts,istoenablesmalljoineriestomanufacturewindowstothegenericdetailshowninAppendixG.

ATMOSPHERICENVIRONMENTSMaterialsshallbecompatiblewiththeatmosphericconditionsofthesite.

NOTE:Corrosionandweatheringofmaterialsusedinwindowassembliescanoccurinatmosphericenvironmentswherethematerialsareincompatiblewiththeenvironmentandotherwindowassemblymaterials,andwithotherbuildingmaterials.

WINDOWPERFORMANCE

Housing

A1GeneralInthisStandard,housingisdefinedasClass1buildingsandClass10buildings,asdescribedintheBuildingCodeofAustralia,andisgovernedbythelimitationsspecifiedinAS4055,exceptthatwindowsinClass10buildingsarenotrequiredtopasstheairinfiltrationandwaterpenetrationrequirementsofthisStandard.

WindowratingsThefollowingshallapply:

WindowassembliesshallberatedasdeterminedinTable2.1andbyachievingthetestresultsdetailedinClausestototheappropriatetestinAS4420,Parts2to6.

Thesupportingmembersshallhavesufficientthicknessofmaterialandstrengthtoensuretheperformanceofthewindow-operatinghardware.

TABLE 2.1

WINDOWRATINGSFORHOUSING

Windowrating

Serviceabilitydesignwindpressure,Pa

N1

500

N2

700

N3

1000

N4

1500

N5

2200

N6

3000

NOTE:Forcyclonicregions,i.e.regionsCandD,thedesignwindpressureshallbeinaccordancewithAS1170.2.

Deflection/spanratioWindowassembliesforhousingshallbesubjectedtothedeflectiontestinaccordancewithAS4420.2.ThetestpressureshallbethedesignwindpressureasspecifiedinTable2.1.Nostructuralmembersinacompletelyassembledandglazedwindowshalldeflectbyanamountgreaterthanspan/150whentestedattheserviceabilitydesignwindpressure.

A1NOTE:Glazingbars,awningandcasementsashstilesandrailsarenotmembersthatrequiredeflectiontests;however,theyshouldcomplywiththeultimatestrengthtestrequirements.

OperatingforcetestWindowsforhousingshallbesubjectedtotheoperatingforcetestinaccordancewithAS4420.3.ThetestforceshallbenotgreaterthanthevalueforwindowsordoorsgiveninTable2.2.

TABLE 2.2OPERATINGFORCEFORTEST

Newtons

Force

Slidingwindowtype

Slidingdoors

Horizontal

Vertical

Toinitiatemovement

110

200

180

Tosustainmovement

90

160

110

A1AirinfiltrationWindowsforClass1buildingsshallbesubjectedtotheairinfiltrationtestinaccordancewithAS4420.4andundereitherofthetestpressuresspecifiedinTable2.3.TheairinfiltrationshallnotexceedthevaluegiveninTable2.3.

A1 TABLE 2.3

MAXIMUMAIRINFILTRATION

Buildingtypeorwindowtype

Pressuredirection

Maximumairinfiltration,L/sm2

Testpressure75Pa

Testpressure150Pa

Airconditioned

Positive,negative

1.0

1.6

Non-airconditioned

Positive

5.0

8.0

Louvrewindow

Positive

20.0

Notapplicable

Adjustablelouvres,residentialandcommercialbuildings

Positive

20.0

32.0

NOTE:ReportsrelatingtotestscarriedoutunderearliereditionsofAS2047remainvalid.ReportsrelatingtotestscarriedoutafterthedateofanamendmenttoaStandardshouldrelatetotheamendedStandard.

A1WaterpenetrationWindowsforClass1buildingsshallbesubjectedtothewaterpenetrationresistancetestinaccordancewithAS4420.5,underthetestpressuresspecifiedinTable2.4.Duringandatthecompletionofthetestthereshallhavebeennopenetrationofuncontrolledwater.Uncontrolledwaterisdefinedas—

waterthatisnotcontainedinapurpose-builtdrainagearea;

waterthatwetsorislikelytowetinsulation,fixturesandfinishes,revealliningsorwindowfurnishingsbeyondthewindowframe;or

waterthatliesontransoms,rails,sills,etc.,whichhasnodesignedmeansofescapetotheoutsideoftheproductviathedrainagesystem.

Acceptablewaterpenetrationisnotdeemedafailureif—

minorsplashingoccursduetoairinfiltration,within1minafterchangeofpressure;

minor,intermittentleakageontheindoorsideofopenablesashes,whichiscontainedonsashgaskets,silltracksandthresholdsthatarepartofadrainagesystemthatallowswatertoflowtotheoutsideoftheproductatcessationofthetest(constantstreamsandregulardrippingwouldberegardedasfailure);or

waterrunningdowntheindoorfaceoflouvres,whichiscompletelycontainedwithinapurpose-builtdrainagearea.

A1 TABLE 2.4

WATERPENETRATIONRESISTANCETESTPRESSURES

Windowratings

Waterpenetrationresistancetestpressure,Pa(seeNote)

Allwindowsexceptajustablelouvres

Adjustablelouvrewindows

N1

150

150

N2

150

150

N3,C1

150

150

N4,C2

200

200

N5,C3

300

200

N6,C4

450

200

NOTE:Waterpenetrationresistancetestpressuresarearbitrarilychosen,consideringthemethodoftestandshallbeinpositivedirectiononly.

UltimatestrengthWindowsforhousingshallnotcollapsewhensubjectedtotheultimatestrengthtestinaccordancewithAS4420.6.‘Collapse’shallmeananyone,oranycombination,ofthefollowing:

A1(a) Failureordislodgmentofanyglazing.

Dislodgmentofaframeoranypartofaframe.

Removalofalight,eitherwithorwithoutitsframingsash,fromaframe.

Lossofsupportofaframe,suchaswhenitisunstableinitsopeninginthebuildingstructure.

Failureofanysash,lockingdevice,fastenerorsupportingstay,allowinganopeninglighttoopen.

ThetestpressureshallbenotlessthanthevaluegiveninTable2.5.

TABLE 2.5

ULTIMATESTRENGTHTESTPRESSURES

Windowratings

Ultimatestrengthtestpressure,Pa

N1

700

N2

1000

N3

1500

N4

2300

N5

3300

N6

4500

NOTE:Forcyclonicregions,i.e.regionsCandD,thedesignwindpressureshallbeinaccordancewithAS1170.2.

Residentialbuildings

General ThisClausecoversresidentialbuildingsofClass2,Class3andClass4partsofbuildingsasdescribedintheBuildingCodeofAustralia,andClass1buildingsoutsidethelimitationsspecifiedinAS4055.

DesignwindpressureThedesignwindpressureforserviceabilitylimitstateandultimatelimitstate,shallbedeterminedinaccordancewithAS1170.2.Alllocalpressurefactorsandinternalpressurecoefficientsrelevanttothelocationofthewindowonthebuildingshallbeconsidered.

NOTE:AguidetodesignwindpressureisgiveninAppendixA.

Deflection/spanratioWindowsshallbesubjectedtothedeflectiontestinaccordancewithAS4420.2.ThetestpressureshallbethedesignwindpressuresdeterminedinClause.Nostructuralmembersinacompletelyassembledandglazedwindowshalldeflectbyanamountgreaterthanspan/180,whentestedattheserviceabilitylimitstatedesignwindpressure.

OperatingforcetestWindowsshallbesubjectedtotheoperatingforcetestinaccordancewithAS4420.3.ThetestforceshallbenotgreaterthanthevaluegiveninTable2.2.

AirinfiltrationWindowsshallbesubjectedtotheairinfiltrationtestinaccordancewithAS4420.4.TheairinfiltrationshallnotexceedtheamountgiveninTable2.3.

WaterpenetrationWindowsshallbesubjectedtothewaterpenetrationresistancetestinaccordancewithAS4420.5.Thetestpressureshallbecalculatedas30%ofthepositiveserviceabilitylimitstatedesignwindpressure,asdeterminedinClause,butnotlessthan150Pa,andinpositivedirectiononly.Duringthetest

A1thereshallbenopenetrationofuncontrolledwater,asspecifiedinClause.

UltimatestrengthWindowsshallnotcollapsewhensubjectedtotheultimatestrengthtestinaccordancewithAS4420.6.‘Collapse’shallbeasspecifiedinClause.

ThetestpressureshallbenotlessthantheultimatelimitstatedesignwindpressuredeterminedinaccordancewithAS1170.2.Alllocalpressurefactorsandinternalpressurecoefficientsrelevanttothelocationofthewindowonthebuildingshallbeconsidered.

Commercialbuildings

GeneralThisClausecoverscommercialbuildingsofClasses5,6,7,8and9,asdescribedintheBuildingCodeofAustralia.

DesignwindpressureThedesignwindpressureforserviceabilitylimitstateandultimatelimitstate,shallbedeterminedinaccordancewithAS1170.2.Alllocalpressurefactorsandinternalpressurecoefficientsrelevanttothelocationofthewindowonthebuildingshallbeconsidered.

NOTE:AguidetodesignwindpressureisgiveninAppendixA.

Deflection/spanratioWindowsshallbesubjectedtothedeflectiontestinaccordancewithAS4420.2.ThetestpressureshallbethedesignwindpressuredeterminedinClause.Nostructuralmembersinacompletelyassembledandglazedwindowshalldeflectbyanamountgreaterthanspan/250,whentestedattheserviceabilitylimitstatedesignwindpressure.

OperatingforcetestWindowsshallbesubjectedtotheoperatingforcetestinaccordancewithAS4420.3.ThetestforceshallbenotgreaterthanthevaluegiveninTable2.2.

AirinfiltrationWindowsshallbesubjectedtotheairinfiltrationtestinaccordancewithAS4420.4.TheairinfiltrationshallnotexceedtheamountgiveninTable2.3.

WaterpenetrationWindowsshallbesubjectedtothewaterpenetrationresistancetestinaccordancewithAS4420.5.Thetestpressureshallbecalculatedas30%

A1ofthepositiveserviceabilitylimitstatedesignwindpressure,asdeterminedinClause,butnotlessthan150Pa,andinpositivedirectiononly.Duringthetestthereshallbenopenetrationofuncontrolledwater,asspecifiedinClause.

NOTE:Whentestingawindowforwaterpenetration,whereinsulationisremovedinordertoobservetheindoorsideofthewindow,themanufacturershouldsupplydrawingsindicatingitsintendedlocationinorderthattheresultmaybedetermined.

UltimatestrengthWindowsshallnotcollapsewhensubjectedtotheultimatestrengthtestinaccordancewithAS4420.6.‘Collapse’shallbeasspecifiedinClause.

ThetestpressureshallbenotlessthantheultimatelimitstatedesignwindpressuredeterminedinaccordancewithAS1170.2.Alllocalpressurefactorsandinternalpressurecoefficientsrelevanttothelocationofthewindowonthebuildingshallbeconsidered.

VERIFICATIONOFSMALLERORLARGERSIZEPRODUCTSAS4420.1,generallyrequiresthetestsamplewindowtoberepresentativeinbothsizeandshapeofthelargeststandardassemblyintheproductrangeasspecifiedbythemanufacturer.Wherethesuppliedproductsarenotofthesamesizeasthoseverifiedbytesting,oneofthefollowingshallapply:

Smallersizeproducts(eithershorterornarrower,orboth),whichhavethesameconstruction(fenestration,sectionsandcomponents)asatestedproduct,shallassumethesamerating,providedtheyareinnowaylessfavourablydisposedandareglazedincompliancewithAS1288.

SmallersizeproductsasdescribedinItem(a)shallberatedatahigherdesignwindpressureratingthanthetestedproduct,providedthecalculationsofdeflectionandstressforallstructuralmemberstoarriveatthehigherratingarecertifiedusingtheactualtestdataforthestructuralmembersandprovidedtheyareinnowaylessfavourablydisposedandareglazedincompliancewithAS1288.

Largersizeproducts(eithertallerorwider,orboth),whichhavethesameconstruction(fenestration,sectionsandcomponents)asatestedproductinaccordancewithAS4420.1,shallassumethesameratingorlowerratingasthetestedproduct,providedthecalculationsofdeflectionandstressforallstructuralmemberstoarriveattheratingarecertifiedusingtheactualtestdataforthestructuralmembers,andprovidedtheyareinnowaylessfavourablydisposedandareglazedincompliancewithA

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論