AS2047—1999
AS2047
(IncorporatingAmendmentNos1and2)
AustralianStandard?
BuildingCodeofAustraliaprimaryreferencedStandard
Windowsinbuildings—Selectionandinstallation
ThisAustralianStandardwaspreparedbyCommitteeBD/21,Windows.ItwasapprovedonbehalfoftheCouncilofStandardsAustraliaon30April1999andpublishedon5June1999.
ThefollowinginterestsarerepresentedonCommitteeBD/21:ArchitecturalAluminiumFabricatorsAssociationAustralianAluminiumCouncil
AustralianBuildingCodesBoard
ConstructionIndustryEngineeringServicesGroupCSIROBuilding,ConstructionandEngineering
FlatGlassandAluminiumAssociationofQueenslandFlatGlassCouncilofAustralia
HousingIndustryAssociationInstitutionofEngineersAustraliaMasterBuildersAustralia
MetalTradesIndustryAssociationofAustraliaNationalAssociationofTestingAuthoritiesAustraliaPlasticsandChemicalsIndustriesAssociationResidentialWindowAssociation
UniversityofNewSouthWales
KeepingStandardsup-to-date
Standardsarelivingdocumentswhichreflectprogressinscience,technologyandsystemsTomaintaintheircurrency,allStandardsareperiodicallyreviewed,andneweditionsarepublished.Betweeneditions,amendmentsmaybeissued.Standardsmayalsobewithdrawn.ItisimportantthatreadersassurethemselvestheyareusingacurrentStandard,whichshouldincludeanyamendmentswhichmayhavebeenpublishedsincetheStandardwaspurchased.
DetailedinformationaboutStandardscanbefoundbyvisitingtheStandardsAustraliawebsiteat
.au
andlookinguptherelevantStandardintheon-linecatalogue.
Alternatively,theprintedCatalogueprovidesinformationcurrentat1Januaryeachyear,andthemonthlymagazine,TheAustralianStandard,hasafulllistingofrevisionsandamendmentspublishedeachmonth.
WealsowelcomesuggestionsfortheimprovementinourStandards,andespeciallyencouragereaderstonotifyusimmediatelyofanyapparentinaccuraciesorambiguities.Contactusviaemailat
mail@.au,
orwritetotheChiefExecutive,StandardsAustraliaInternationalLtd,POBox5420,Sydney,NSW2001.
ThisStandardwasissuedindraftformforcommentasDR98349.
AS2047—1999
(IncorporatingAmendmentNos1and2)
AustralianStandard?
Windowsinbuildings—Selectionandinstallation
OriginatedinpartaspartofSAAInt.318—1951.FinaleditionAS2147—1996andAS2147.2—1996.
AS2047.1—1996andAS2047.2—1996revised,
amalgamatedandredesignatedAS2047—1999.ReissuedincorporatingAmendmentNo.1(January2001).ReissuedincorporatingAmendmentNo.2(June2001).
COPYRIGHT
?StandardsAustraliaInternational
Allrightsarereserved.Nopartofthisworkmaybereproducedorcopiedinanyformorbyanymeans,electronicormechanical,includingphotocopying,withoutthewrittenpermissionofthepublisher.
PublishedbyStandardsAustraliaInternationalLtdGPOBox5420,Sydney,NSW2001,Australia
ISBN0733727204
AS2047—1999
PAGE
2
PAGE
3
AS2047—1999
PREFACE
ThisStandardwaspreparedbytheJointStandardsAustralia/StandardsNewZealandCommitteeBD/21,Windows,tosupersede,AS2047.1—1996,Windowsinbuildings,Partl:SpecificationformaterialsandperformanceandAS2047.2—1996,Windowsinbuildings—Part2:Construction,installationandmaintenance.Afterallowingsufficienttimeforadjustment(nominally12monthsfrompublication),thesupersededdocumentswillbewithdrawn.
ThisStandardincorporatesAmendmentNo.l(January200l)andAmendmentNo.2(June200l).ThechangesarisingfromtheAmendmentsareindicatedinthetextbyamarginalbarandamendmentnumberagainsttheclause,note,table,figure,orpartthereofaffected.
ThisStandardistheresultofaconsensusamongAustralianandNewZealandrepresentativesontheJointCommitteetoproduceitasanAustralianStandard.
TheobjectiveofthisStandardistoprovidewindowdesignersandmanufacturerswithagenericwindowcode,settingouttheperformancerequirementsandspecificationsinthedesignandmanufactureofallwindows,regardlessofmaterials.
ThisStandardhasbeenrevisedtomakeitsuitableforreferenceintheBuildingCodeofAustralia(BCA)asaStandardforregulatoryreference.
Thewindowratingsystemisasimplifiedsystemandwindowsspecificallydesignedforcornershavebeenomitted(seeAppendixA).
Theeffectsofatmosphericenvironments(corrosionandweathering)onmaterialsusedinwindowassembliesiscurrentlybeingconsideredbytheCommitteemembersforimprovementandinclusioninthenextrevision.
InthisStandard,statementexpressedinmandatorytermsinnotestotablesaredeemedtobeanintegralpartoftheStandard.
Theterm‘informative’hasbeenusedinthisStandardtodefinetheapplicationoftheappendixtowhichitapplies.An‘informative’appendixisonlyforinformationandguidance.
CONTENTS
Page
SECTION1SCOPEANDGENERAL
SCOPE 5
APPLICATION 6
REFERENCEDDOCUMENTS 6
DEFINITIONS 6
SECTION2PERFORMANCE
GENERAL 8
ATMOSPHERICENVIRONMENTS 8
WINDOWPERFORMANCE 8
VERIFICATIONOFSMALLERORLARGERSIZEPRODUCTS 13
USEANDRATINGOFWINDOWCOUPLINGSYSTEMS 14
SECTION3FRAMINGANDFINISHES
ALUMINIUMWINDOWS 15
TIMBERWINDOWS 16
UNPLASTICIZEDPVC(UPVC)WINDOWS 19
WINDOWSOFOTHERMATERIALS 19
SECTION4GLAZING
GENERAL 21
GLASS 21
GLAZINGMATERIALS 21
SECTION5COMPONENTS
HARDWARE 22
FASTENERS 22
WEATHERPROOFING 22
SECURITY 22
ANCHORINGDEVICES 22
SECTION6CONSTRUCTION
GENERAL 24
TOLERANCES 24
JOINTS 24
GLAZING 24
REVEALLININGS 24
FLASHINGS 24
SECTION7INSTALLATION
WINDOWSELECTION 25
INSTALLATION 25
THERMALANDSTRUCTURALMOVEMENT 25
ON-SITECARE 25
Page
SECTION8LABELLINGANDCERTIFICATE
8.1 GENERAL..............................................
26
8.2 LABELLING.............................................
26
8.3 CERTIFICATE...........................................
26
APPENDICES
A
GUIDETODESIGNWINDPRESSURE...........................
27
B
MEANSFORDEMONSTRATINGCOMPLIANCEWITHTHISSTANDARD
30
C
REFERENCEDDOCUMENTS..................................
32
D
NOMINATIONOFWINDOWRATINGSANDDESIGNWINDPRESSURE.
34
E
SURFACEFINISHFORALUMINIUM...........................
35
F
ON-SITECARE............................................
37
A1
G
GENERICTIMBERWINDOWS................................
38
A2
H
GENERICWINDOWSTESTRESULTS...........................
55
PAGE
11
AS2047—1999
AS2047—1999
PAGE
10
.au
?StandardsAustralia
?StandardsAustralia
.au
STANDARDSAUSTRALIA
AustralianStandard
Windowsinbuildings—Selectionandinstallation
SECTION 1 SCOPE AND GENERAL
SCOPE ThisStandardspecifiesrequirements,materials,construction,installationandglazingfor—
windows;
slidingglazeddoors;
A1 (c) adjustablelouvres;
shopfronts;and
windowwallswithone-pieceframingelements.
NOTE:Windowwallsdonotincludecurtainwallsusingstackedorverticallysplicedframingsystems,manufacturedfromanymaterialandinstalledinexternalwallsofallclassesofbuildings.
Throughoutthisstandardtheterm‘window(s)’meanswindowofanytype,includinglouvre(s)andslidingdoor(s).
NOTES:
Thewindowratings,orclassifications,differfrompreviousglassandwindowStandardsduetothemoreaccurateevaluationoftheeffectofwindconditions.TheyarebasedoneitherAS1170.2,orthespecificwindloadingcodedevelopedforhousing,i.e.AS4055.
SeeAppendixAforinformationonwindloadsapplicabletowindowscoveredbythisStandard.
SeeAppendixBforalternativemeansofdemonstratingcompliancewiththisStandard.
Prefabricatedbaywindowsthatincorporateslopedglassareclassifiedaswindowsinexternalwalls.
RefertoAS/NZS4284forperformancespecificationofbuildingfacade.ConformancetotherequirementsinAS/NZS4284willbedeemedtosatisfytherequirementsofthisStandard.However,slidingwindowsashesordoorswillrequiretheoperatingforcetestinaccordancewithAS4420.3.
A1, 6ThefollowingarenotcoveredbythisStandard:
A2 (a)Hingeddoors,includingFrenchandbi-folddoors.
Revolvingglazeddoors.
Fixedlouvres.
Skylightsandrooflightsandwindowsinotherthantheverticalplane.
Windowsingreenhousesandagriculturalbuildings.
Slidingdoorswithoutframessuchasinternaldoorsandshopfrontdoors.
Windowsconstructedonsiteandarchitecturalone-offwindows,whicharenotdesigntested.
Second-handwindows,re-usedwindows,replacementwindows,orrecycledwindows.
Heritagewindows,forheritagebuildingsasdefinedbytherelevantStateorTerritoryauthority.
APPLICATIONThisStandardwillbereferencedintheBuildingCodeofAustraliabywayofBCAAmendmentNo.5tobepublishedby1July1999.
REFERENCEDDOCUMENTSThedocumentsreferredtointhisStandardarelistedinAppendixC.
DEFINITIONSForthepurposeofthisStandard,thedefinitionsgiveninAS\NZS4491andthosebelowapply.
Curtainwall—anon-load-bearingwindowwallthatisnotapanelwall.
Door—aslidingsashofasizesuitableforuseasaccessthroughwalls.
Fenestration—thearrangementofwindowsandotheropeningsontheexternalwallsofbuildings,especiallythefacade.
Fin—apieceofglasspositionedsuchastoprovidelateralsupport.
Fixing—anyitemthatisusedtosecuremembersofawindowassemblytoeachother,tosecureanitemofhardwaretoawindowmember,ortosecureacompletedwindowassemblyintothebuildingstructure.
Flashing—animperviousmembraneinstalledinsuchamannerastopreventingressofwaterintothebuilding.
Frame—thatpartofawindowassemblysurroundingthesashesorfixedglazing.Itisanassemblymanufacturedfromtimber,metal,glass,orotherdurablematerialorcombinationsofmaterials,suchasglassfinsandstructuralsealantformingpartoftheassemblyofaglazedpanelandsupportingthefulllengthofalltheedgesoftheglass.
NOTE:Butt-jointedglasspanelsthatarenotinthesameplanecansatisfytherequirementsforframes.
Glass—ahard,brittle,amorphoussubstanceproducedbyfusionandusuallyconsistingofmutuallydissolvedsilicaorsilicatesthatalsocontainsodaandlime.Itmaybetransparent,translucentoropaque.
Glazingbar—amemberthatisaddedtoastandardwindowconstructiontochangetheappearanceofthewindow.Itcanbeintheforminwhichtheglassisglazed,clipped,orstuckontoeitherorbothfacesoftheglass.
Glazinggasket—plasticorsyntheticrubbermembers,usedbetweentheglassandtheframeortheglassandthebead.
Hardware—equipmentusedintheopening,operating,closing,lockingandstoppingofsashes.
Head—thetophorizontalframingmemberofawindowassembly.
Jamb—averticalsideframingmember.
Light—seewindowlight.
Louvre—awindowunitcomprisingaseriesofbladesofglass,orothermaterial,lappingeachother.
Meetingstiles—verticalintermediatesashmembersthatmeetwhenthewindowisclosedsuchthattheycombinetoactinunison.
Meetingrails—horizontalintermediatesashmembersthatmeetwhenthewindowisclosedsuchthattheycombinetoactinunison
Mullion—averticalintermediateframingmember.
Multi-lightwindow—awindowincorporatingmorethanoneopeningorfixedlight,orboth,withinoneperimeterframe,aslowlights,highlightsorsidelights.
Newton—theforcewhich,whenappliedtoabodyhavingamassofonekilogram,causesanaccelerationofonemetrepersecondsquaredinthedirectionofapplicationoftheforce.
Panelwall—anon-load-bearingwindowwallthatiswhollysupportedateachstorey.
Pascal(Pa)—thepressureorstressthatariseswhenaforceofonenewtonisapplieduniformlyoveranareaofonesquaremetre.
Reveal—thevisiblepartofeachsideofawindowopeningnotcoveredbytheframe,ortherecessbetweentheframeandthefaceofthewall.
Sash—theseparateframe,toawindow,carryingtheglass.Itmaybefixed(inoperable)ormovable(operable).
A11.4.25 Sill—thebottomhorizontalframingmemberofawindowassembly.
Stile,sash—averticalsidememberofasash.
Structuralmembers—theelements,includingmullions,transoms,meetingrails,andmeetingstiles,thatperformthefunctionoftransferringloadstotheperimeterframe.
NOTE:Glazingbars,awningandcasementsashstilesandrailsarenotconsideredstructural
A1 membersforhousing;however,theyareconsideredstructuralmembersforresidentialandcommercialbuildings.
Transom—ahorizontalintermediateframingmemberofawindowassembly.
Weatherseal—amaterialincludedinawindowassemblytoreducetheairinfiltrationorimproveresistancetowaterpenetration.
Wind—displacementofparallelmemberswithrespecttooneanother.
Windowassembly—acompleteunitcomprisingframe,couplings,sashes,glazinginfillpanelsandhardware.
Windowlight—asinglepanelorglazinginawindowassembly.
Windowrating—aclassificationsystemprovidingforwindowstobetestedtodeterminetheirlevelofperformanceforstrengthandweatherproofness.Windowratingsforhousingareexpressedinwindclassificationterms(seeTable2.1),andwindowratingsforbuildingsotherthanhousingareexpressedinpermissibleorlimitstatedesignwindpressureterms.
Windowwall—aseriesofmulti-lightwindows,generallyspanningfromfloortoceiling,andoftencontinuoushorizontally.
SECTION 2 PERFORMANCE
GENERALThisSectiondetailsperformancecriteriaforwindowassembliesthatareclassifiedbyaratingsystemforhousing,andbydesignwindpressuresforresidentialandcommercialbuildings.
NOTES:
TheperformancelevelsofwindowsgiveninthisSectionaretheresultofmanyyearsoftestingunitsinlaboratoriesandtheevaluationofbuildingsitesafterhighwindsandcyclonesinvariousregionsofAustralia.
Thewindowratings,orclassifications,differfrompreviousglassandwindowStandardsduetothemoreaccurateevaluationoftheeffectofthesewindconditions.TheyarebasedoneitherAS1170.2,orthespecificwindloadingcodedevelopedforhousing,i.e.AS4055.
A12.1.1GenerictimberwindowsWindowsmadetothedetailsinAppendixGaredeemedtocomplywiththeappropriatestructuralperformanceandwaterpenetrationrequirementsofClause2.3.
NOTE:TheobjectiveofincludingthegenerictimberwindowsintheStandard,asanacceptablealternativetoindividualtestingofspecificfabricatorproducts,istoenablesmalljoineriestomanufacturewindowstothegenericdetailshowninAppendixG.
ATMOSPHERICENVIRONMENTSMaterialsshallbecompatiblewiththeatmosphericconditionsofthesite.
NOTE:Corrosionandweatheringofmaterialsusedinwindowassembliescanoccurinatmosphericenvironmentswherethematerialsareincompatiblewiththeenvironmentandotherwindowassemblymaterials,andwithotherbuildingmaterials.
WINDOWPERFORMANCE
Housing
A1GeneralInthisStandard,housingisdefinedasClass1buildingsandClass10buildings,asdescribedintheBuildingCodeofAustralia,andisgovernedbythelimitationsspecifiedinAS4055,exceptthatwindowsinClass10buildingsarenotrequiredtopasstheairinfiltrationandwaterpenetrationrequirementsofthisStandard.
WindowratingsThefollowingshallapply:
WindowassembliesshallberatedasdeterminedinTable2.1andbyachievingthetestresultsdetailedinClausestototheappropriatetestinAS4420,Parts2to6.
Thesupportingmembersshallhavesufficientthicknessofmaterialandstrengthtoensuretheperformanceofthewindow-operatinghardware.
TABLE 2.1
WINDOWRATINGSFORHOUSING
Windowrating
Serviceabilitydesignwindpressure,Pa
N1
500
N2
700
N3
1000
N4
1500
N5
2200
N6
3000
NOTE:Forcyclonicregions,i.e.regionsCandD,thedesignwindpressureshallbeinaccordancewithAS1170.2.
Deflection/spanratioWindowassembliesforhousingshallbesubjectedtothedeflectiontestinaccordancewithAS4420.2.ThetestpressureshallbethedesignwindpressureasspecifiedinTable2.1.Nostructuralmembersinacompletelyassembledandglazedwindowshalldeflectbyanamountgreaterthanspan/150whentestedattheserviceabilitydesignwindpressure.
A1NOTE:Glazingbars,awningandcasementsashstilesandrailsarenotmembersthatrequiredeflectiontests;however,theyshouldcomplywiththeultimatestrengthtestrequirements.
OperatingforcetestWindowsforhousingshallbesubjectedtotheoperatingforcetestinaccordancewithAS4420.3.ThetestforceshallbenotgreaterthanthevalueforwindowsordoorsgiveninTable2.2.
TABLE 2.2OPERATINGFORCEFORTEST
Newtons
Force
Slidingwindowtype
Slidingdoors
Horizontal
Vertical
Toinitiatemovement
110
200
180
Tosustainmovement
90
160
110
A1AirinfiltrationWindowsforClass1buildingsshallbesubjectedtotheairinfiltrationtestinaccordancewithAS4420.4andundereitherofthetestpressuresspecifiedinTable2.3.TheairinfiltrationshallnotexceedthevaluegiveninTable2.3.
A1 TABLE 2.3
MAXIMUMAIRINFILTRATION
Buildingtypeorwindowtype
Pressuredirection
Maximumairinfiltration,L/sm2
Testpressure75Pa
Testpressure150Pa
Airconditioned
Positive,negative
1.0
1.6
Non-airconditioned
Positive
5.0
8.0
Louvrewindow
Positive
20.0
Notapplicable
Adjustablelouvres,residentialandcommercialbuildings
Positive
20.0
32.0
NOTE:ReportsrelatingtotestscarriedoutunderearliereditionsofAS2047remainvalid.ReportsrelatingtotestscarriedoutafterthedateofanamendmenttoaStandardshouldrelatetotheamendedStandard.
A1WaterpenetrationWindowsforClass1buildingsshallbesubjectedtothewaterpenetrationresistancetestinaccordancewithAS4420.5,underthetestpressuresspecifiedinTable2.4.Duringandatthecompletionofthetestthereshallhavebeennopenetrationofuncontrolledwater.Uncontrolledwaterisdefinedas—
waterthatisnotcontainedinapurpose-builtdrainagearea;
waterthatwetsorislikelytowetinsulation,fixturesandfinishes,revealliningsorwindowfurnishingsbeyondthewindowframe;or
waterthatliesontransoms,rails,sills,etc.,whichhasnodesignedmeansofescapetotheoutsideoftheproductviathedrainagesystem.
Acceptablewaterpenetrationisnotdeemedafailureif—
minorsplashingoccursduetoairinfiltration,within1minafterchangeofpressure;
minor,intermittentleakageontheindoorsideofopenablesashes,whichiscontainedonsashgaskets,silltracksandthresholdsthatarepartofadrainagesystemthatallowswatertoflowtotheoutsideoftheproductatcessationofthetest(constantstreamsandregulardrippingwouldberegardedasfailure);or
waterrunningdowntheindoorfaceoflouvres,whichiscompletelycontainedwithinapurpose-builtdrainagearea.
A1 TABLE 2.4
WATERPENETRATIONRESISTANCETESTPRESSURES
Windowratings
Waterpenetrationresistancetestpressure,Pa(seeNote)
Allwindowsexceptajustablelouvres
Adjustablelouvrewindows
N1
150
150
N2
150
150
N3,C1
150
150
N4,C2
200
200
N5,C3
300
200
N6,C4
450
200
NOTE:Waterpenetrationresistancetestpressuresarearbitrarilychosen,consideringthemethodoftestandshallbeinpositivedirectiononly.
UltimatestrengthWindowsforhousingshallnotcollapsewhensubjectedtotheultimatestrengthtestinaccordancewithAS4420.6.‘Collapse’shallmeananyone,oranycombination,ofthefollowing:
A1(a) Failureordislodgmentofanyglazing.
Dislodgmentofaframeoranypartofaframe.
Removalofalight,eitherwithorwithoutitsframingsash,fromaframe.
Lossofsupportofaframe,suchaswhenitisunstableinitsopeninginthebuildingstructure.
Failureofanysash,lockingdevice,fastenerorsupportingstay,allowinganopeninglighttoopen.
ThetestpressureshallbenotlessthanthevaluegiveninTable2.5.
TABLE 2.5
ULTIMATESTRENGTHTESTPRESSURES
Windowratings
Ultimatestrengthtestpressure,Pa
N1
700
N2
1000
N3
1500
N4
2300
N5
3300
N6
4500
NOTE:Forcyclonicregions,i.e.regionsCandD,thedesignwindpressureshallbeinaccordancewithAS1170.2.
Residentialbuildings
General ThisClausecoversresidentialbuildingsofClass2,Class3andClass4partsofbuildingsasdescribedintheBuildingCodeofAustralia,andClass1buildingsoutsidethelimitationsspecifiedinAS4055.
DesignwindpressureThedesignwindpressureforserviceabilitylimitstateandultimatelimitstate,shallbedeterminedinaccordancewithAS1170.2.Alllocalpressurefactorsandinternalpressurecoefficientsrelevanttothelocationofthewindowonthebuildingshallbeconsidered.
NOTE:AguidetodesignwindpressureisgiveninAppendixA.
Deflection/spanratioWindowsshallbesubjectedtothedeflectiontestinaccordancewithAS4420.2.ThetestpressureshallbethedesignwindpressuresdeterminedinClause.Nostructuralmembersinacompletelyassembledandglazedwindowshalldeflectbyanamountgreaterthanspan/180,whentestedattheserviceabilitylimitstatedesignwindpressure.
OperatingforcetestWindowsshallbesubjectedtotheoperatingforcetestinaccordancewithAS4420.3.ThetestforceshallbenotgreaterthanthevaluegiveninTable2.2.
AirinfiltrationWindowsshallbesubjectedtotheairinfiltrationtestinaccordancewithAS4420.4.TheairinfiltrationshallnotexceedtheamountgiveninTable2.3.
WaterpenetrationWindowsshallbesubjectedtothewaterpenetrationresistancetestinaccordancewithAS4420.5.Thetestpressureshallbecalculatedas30%ofthepositiveserviceabilitylimitstatedesignwindpressure,asdeterminedinClause,butnotlessthan150Pa,andinpositivedirectiononly.Duringthetest
A1thereshallbenopenetrationofuncontrolledwater,asspecifiedinClause.
UltimatestrengthWindowsshallnotcollapsewhensubjectedtotheultimatestrengthtestinaccordancewithAS4420.6.‘Collapse’shallbeasspecifiedinClause.
ThetestpressureshallbenotlessthantheultimatelimitstatedesignwindpressuredeterminedinaccordancewithAS1170.2.Alllocalpressurefactorsandinternalpressurecoefficientsrelevanttothelocationofthewindowonthebuildingshallbeconsidered.
Commercialbuildings
GeneralThisClausecoverscommercialbuildingsofClasses5,6,7,8and9,asdescribedintheBuildingCodeofAustralia.
DesignwindpressureThedesignwindpressureforserviceabilitylimitstateandultimatelimitstate,shallbedeterminedinaccordancewithAS1170.2.Alllocalpressurefactorsandinternalpressurecoefficientsrelevanttothelocationofthewindowonthebuildingshallbeconsidered.
NOTE:AguidetodesignwindpressureisgiveninAppendixA.
Deflection/spanratioWindowsshallbesubjectedtothedeflectiontestinaccordancewithAS4420.2.ThetestpressureshallbethedesignwindpressuredeterminedinClause.Nostructuralmembersinacompletelyassembledandglazedwindowshalldeflectbyanamountgreaterthanspan/250,whentestedattheserviceabilitylimitstatedesignwindpressure.
OperatingforcetestWindowsshallbesubjectedtotheoperatingforcetestinaccordancewithAS4420.3.ThetestforceshallbenotgreaterthanthevaluegiveninTable2.2.
AirinfiltrationWindowsshallbesubjectedtotheairinfiltrationtestinaccordancewithAS4420.4.TheairinfiltrationshallnotexceedtheamountgiveninTable2.3.
WaterpenetrationWindowsshallbesubjectedtothewaterpenetrationresistancetestinaccordancewithAS4420.5.Thetestpressureshallbecalculatedas30%
A1ofthepositiveserviceabilitylimitstatedesignwindpressure,asdeterminedinClause,butnotlessthan150Pa,andinpositivedirectiononly.Duringthetestthereshallbenopenetrationofuncontrolledwater,asspecifiedinClause.
NOTE:Whentestingawindowforwaterpenetration,whereinsulationisremovedinordertoobservetheindoorsideofthewindow,themanufacturershouldsupplydrawingsindicatingitsintendedlocationinorderthattheresultmaybedetermined.
UltimatestrengthWindowsshallnotcollapsewhensubjectedtotheultimatestrengthtestinaccordancewithAS4420.6.‘Collapse’shallbeasspecifiedinClause.
ThetestpressureshallbenotlessthantheultimatelimitstatedesignwindpressuredeterminedinaccordancewithAS1170.2.Alllocalpressurefactorsandinternalpressurecoefficientsrelevanttothelocationofthewindowonthebuildingshallbeconsidered.
VERIFICATIONOFSMALLERORLARGERSIZEPRODUCTSAS4420.1,generallyrequiresthetestsamplewindowtoberepresentativeinbothsizeandshapeofthelargeststandardassemblyintheproductrangeasspecifiedbythemanufacturer.Wherethesuppliedproductsarenotofthesamesizeasthoseverifiedbytesting,oneofthefollowingshallapply:
Smallersizeproducts(eithershorterornarrower,orboth),whichhavethesameconstruction(fenestration,sectionsandcomponents)asatestedproduct,shallassumethesamerating,providedtheyareinnowaylessfavourablydisposedandareglazedincompliancewithAS1288.
SmallersizeproductsasdescribedinItem(a)shallberatedatahigherdesignwindpressureratingthanthetestedproduct,providedthecalculationsofdeflectionandstressforallstructuralmemberstoarriveatthehigherratingarecertifiedusingtheactualtestdataforthestructuralmembersandprovidedtheyareinnowaylessfavourablydisposedandareglazedincompliancewithAS1288.
Largersizeproducts(eithertallerorwider,orboth),whichhavethesameconstruction(fenestration,sectionsandcomponents)asatestedproductinaccordancewithAS4420.1,shallassumethesameratingorlowerratingasthetestedproduct,providedthecalculationsofdeflectionandstressforallstructuralmemberstoarriveattheratingarecertifiedusingtheactualtestdataforthestructuralmembers,andprovidedtheyareinnowaylessfavourablydisposedandareglazedincompliancewithA
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025版鋼筋工程節(jié)能減排技術(shù)應(yīng)用合同3篇
- 2024年度禹陽離婚協(xié)議中房產(chǎn)及車輛分割及子女撫養(yǎng)協(xié)議3篇
- 2024年版智能醫(yī)療設(shè)備研發(fā)與銷售合同
- 2025版辦公室場地租賃與員工培訓(xùn)及拓展訓(xùn)練服務(wù)合同3篇
- 2025版金融機(jī)構(gòu)與政府項目借款合同模板3篇
- 2024年項目:漿砌片石擋墻勞務(wù)合作合同
- 2024年經(jīng)營權(quán)承包合同匯編
- 2024年金融中介服務(wù)協(xié)議-證券行業(yè)版3篇
- 2024年車輛識別一體機(jī)技術(shù)服務(wù)合同
- 保山職業(yè)學(xué)院《歷史建筑實(shí)錄》2023-2024學(xué)年第一學(xué)期期末試卷
- 教練式溝通培訓(xùn)課件
- 養(yǎng)老院品牌建設(shè)與推廣策略
- 族概述與族操作-創(chuàng)建參數(shù)化三維族(Revit建模課件)
- 《機(jī)電一體化系統(tǒng)設(shè)計》
- 歷史 小錢幣大歷史教學(xué)設(shè)計
- 文印服務(wù)投標(biāo)方案(技術(shù)方案)
- 消防控制室值班服務(wù)投標(biāo)方案
- 醫(yī)養(yǎng)結(jié)合養(yǎng)老院(養(yǎng)老中心)項目可行性報告
- 初三語文總復(fù)習(xí)全程計劃表
- 小兒橫紋肌肉瘤
- 客戶關(guān)系深度經(jīng)營與開發(fā)
評論
0/150
提交評論