?注冊消防工程師之消防安全技術實務高分通關題型題庫帶解析答案
單選題(共50題)1、某變電站室內設置了單臺油量為150kg的用油電氣設備,并設置擋油設施及將事故油排至安全處的設施,其擋油設施的容積宜按()kg設計.A.15B.30C.150D.200【答案】B2、()是物質從一種狀態(tài)迅速轉變成另一狀態(tài),并在瞬間放出大量能量,同時產生聲響現象。A.爆炸B.閃燃C.自燃D.著火【答案】A3、根據現行國家標準《建筑防煙排煙系統(tǒng)技術標準》(GB51251),采用自然通風方式的避難層地面面積300m2,其外窗的設置錯誤的是()。A.東側南側外墻各有3扇開啟面積為1m2的可開啟外窗B.南側外墻開1m2可開啟外窗,西側開8m2可開啟外窗C.東側南側西側墻面各開啟3m2的可開啟外窗D.北側外墻有2m2可開啟外窗,東側和西側外墻各有3m2可開啟外窗【答案】B4、某人民防空工程中有一需做防火分隔部位無法采用防火墻進行防火分隔,采用了防火卷簾。需做防火分隔部位寬度為24m,按規(guī)范要求,防火卷簾寬度不應大于()m。A.10B.15C.20D.8【答案】A5、下列關于室外消火栓的設置要求說法錯誤的是()。A.室外消火栓應沿道路設置,當道路寬度大于60m時,宜在道路兩側交叉錯落設置消火栓,并宜靠近十字路口B.室外消火栓的間距不應大于120mC.消火栓距路邊不應大于2m,距房屋外墻不宜小于5mD.室外消火栓宜集中布置在建筑一側【答案】D6、下列選項中,宜選擇線型光束感煙火災探測器是()。A.有大量粉塵、水霧滯留房間B.在正常情況下有煙滯留房間C.無遮擋大空間或有特殊要求房間D.可能產生蒸汽和油霧房間【答案】C7、下列關于可燃氣體探測報警系統(tǒng)的說法中,錯誤的是()。A.探測氣體密度與空氣密度相當時,可燃氣體探測器可設置在被保護空間的中間部位或頂部B.線型可燃氣體探測器的保護區(qū)域長度不宜大于100mC.當有消防控制室時,可燃氣體報警控制器可設置在保護區(qū)域附近D.當無消防控制室時,可燃氣體報警控制器應設置在有人值班的場所【答案】B8、關于水噴霧滅火系統(tǒng)保護對象保護面積說法,下列不正確是()。A.液化石油氣灌瓶間保護面積應按其使用面積確定B.桶裝酒庫保護面積應按防火分區(qū)建筑面積確定C.開口容器保護面積應按其液面面積確定D.液化石油氣瓶庫保護面積應按其所在防火分區(qū)使用面積確定【答案】D9、爆炸性氣體混合物應按引燃溫度分組,下列組別中引燃溫度最低是()。A.T1B.T3C.T5D.T6【答案】D10、某耐火等級為二級單層倉庫,主要存儲膠帶、生松香、自熄性塑料制品,分別占該倉庫使用面積10%、10%、60%,則該倉庫與附近新建建筑高度26m住宅建筑之間防火間距不宜小于()m。A.9B.6C.25D.50【答案】C11、衡量可燃液體火災危險性最直接指標是蒸氣壓,由于蒸氣壓很難測量,通常使用閃點來確定可燃液體火災危險性,關于可燃液體下列說法正確是()。A.閃點是指遇明火能發(fā)生閃燃最低溫度B.閃點一定低于燃點C.液體均具有閃燃現象,閃點是衡量液體火災危險性重要指標D.除閃點外,燃點也是液體火災危險性重要指標,燃點越低液體,越易燃燒【答案】B12、下列關于可以不設置備用消防水泵說法中,錯誤是()。A.建筑高度為40米住宅B.室內消防給水設計流量為10L/s宿舍樓C.室外消防給水設計流量為30L/s玻璃廠房D.室內消防給水設計流量為10L/s甲醇生產廠房【答案】C13、下列選項中,屬于高層建筑的是()。A.建筑高度為24m的6層瀝青加工廠B.建筑高度為27m的9層服裝加工廠員工宿舍C.建筑高度為24m的6層儲存棉麻織物倉庫D.建筑高度為27m的9層棉花打包車間【答案】D14、疏散通道上設置防火卷簾聯動控制設計規(guī)定,防火卷簾下降至距樓板面()m處、下降到樓板面動作信號和防火卷簾控制器直接連接感煙、感溫火災探測器報警信號,應反饋至消防聯動控制器。A.1.8B.1.5C.1.3D.1.2【答案】A15、作為防火墻等效替代措施之一,下列關于用于防火分隔避難走道描述中,表述正確是()。A.任一防火分區(qū)通向避難走道門至該避難走道最近直通地面出口距離不應大于60m,設置了自動滅火系統(tǒng),應增加25%B.避難走道內部頂棚、墻面裝修材料燃燒性能應為A級,地面裝修材料燃燒性能不應低于B1級C.避難走道防火隔墻耐火極限不應低于2.50h,樓板耐火極限不應低于1.50hD.防火分區(qū)至避難走道入口處應設置防煙前室,開向前室門應采用甲級防火門,前室開向避難走道門應采用乙級防火門【答案】D16、火災報警控制器和消防聯動控制器設計需要考慮設計容量,根據《火災自動報警系統(tǒng)設計規(guī)范》,以下說法錯誤是()。A.任一臺火災報警控制器所連接設備總數和地址總數不超過3200點B.任一臺消防聯動控制器地址總數不應超過1600點C.任一臺火災報警控制器(聯動型)所控制各類模塊總數不應超過3200個點D.每一聯動總線回路連結設備總數不宜超過100點,且應留有不少于額定容量10%余量【答案】C17、下列選項不屬于隧道火災危害性是()A.人員傷亡多B.經濟損失巨大C.次生災害危害嚴重D.火災點移動性【答案】D18、軸流深井泵安裝于水井時,其淹沒深度應滿足其可靠運行要求,在水泵出流量為150%設計流量時,其最低淹沒深度應是第一個水泵葉輪底部水位線以上不少于()m。A.2B.2.5C.3D.3.2【答案】D19、下列關于飛機庫平面布置和防火分隔說法,錯誤是()。A.甲、乙、丙類物品暫存間設置在飛機庫內時,應采用防火墻和耐火極限不低于1.50h頂板隔開B.在飛機庫內少量設置辦公室、資料室、休息室等用房時,宜靠外墻設置,并應直通安全出口或疏散走道,與飛機停放和維修區(qū)之間應采用耐火極限不低于2.00h不燃燒體墻和1.50h頂板隔開,墻體上門窗應為甲級防火門窗C.飛機庫內防火分區(qū)之間應采用防火墻分隔,確有困難局部開口可采用耐火極限不低于3.00h防火卷簾D.飛機庫應采用防火墻與辦公樓、飛機部件噴漆間、飛機座椅維修間、航材庫、配電室和動力站等生產輔助用房隔開,防火墻上門窗應采用甲級防火門窗,或耐火極限不低于3.00h防火卷簾【答案】A20、大型石油化工企業(yè)的工藝裝置區(qū)或罐區(qū),消防給水干管的管徑應經計算確定。獨立的消防給水管道的流速不宜大于()。A.1.5m/sB.2.0m/sC.2.5m/sD.3.5m/s【答案】D21、下列說法中不正確是()。A.細水霧自動噴水滅火系統(tǒng)可用于液化天然氣火災滅火B(yǎng).水噴霧自動噴水滅火系統(tǒng)可用于電氣火災滅火C.雨淋自動噴水滅火系統(tǒng)可用于室內凈空高度超過一定高度,且必須迅速撲救初期火災場所D.防護冷卻水幕系統(tǒng)可用于控制分隔物溫度,使分隔物完整性和隔熱性免遭火災破壞場所【答案】A22、根據《建筑設計防火規(guī)范》,電纜井、管道井、排煙道、排氣道、垃圾道等豎向管道井,應分別獨立設置;井壁上檢查門應采用()防火門。A.甲級B.乙級C.丙級D.丁級【答案】C23、某帶頂棚的步行街,且步行街兩側的建筑需利用步行街進行安全疏散時,下列關于步行街兩側商鋪的防火分隔措施的說法中,錯誤的是()。A.商鋪之間應設置耐火極限不低于2.0h的防火隔墻,每間商鋪的建筑面積不宜大于300m2B.商鋪面向步行街一側的圍護結構的耐火極限不應低于1.0h,并宜采用實體墻C.商鋪面向步行街一側的圍護結構,當采用非隔熱性的防火玻璃墻時,耐火極限不低于0.5h,且應設置自動噴水滅火系統(tǒng)全保護D.相鄰商鋪之間面向步行街一側應設置寬度不小于1.0m、耐火極限不應低于1.0h的實體墻【答案】C24、下列關于疏散門設置要求描述中,正確是()。A.除甲、乙類生產車間和儲存?zhèn)}庫外,人數不超過60人且每樘門平均疏散人數不超過20人房間,其疏散門開啟方向不限B.乙類倉庫首層靠墻外側可采用推拉門或卷簾門C.疏散走道在防火分區(qū)處應設置常開甲級防火門D.廠房疏散門總凈寬度應經計算確定,門最小凈寬度不宜小于1.20m【答案】C25、民用建筑類別是根據建筑高度、使用功能、火災危險性和撲救難易程度進行確定,主要分為住宅建筑和公共建筑兩大類。下列關于民用建筑類別劃分說法中,不正確是()。A.在防火方面,宿舍、公寓等防火要求按公共建筑有關規(guī)定執(zhí)行B.對建筑高度大于24m單層公共建筑主要使用功能為單層時,該建筑為單層建筑C.對建筑高度大于24m單層公共建筑主要使用功能難以區(qū)分時,并且單層部分與多層或高層部分采用防火墻分開時,該建筑為多層或高層建筑D.30m高層醫(yī)療建筑,其劃分為一類高公共建筑【答案】C26、某有人防護區(qū)設有七氟丙烷氣體滅火系統(tǒng)保護,下列關于該系統(tǒng)聯動控制設計做法,不符合規(guī)范要求是()。A.系統(tǒng)采用一只感煙火災探測器報警信號和一只感溫火災探測器報警信號作為聯動觸發(fā)信號B.防護區(qū)內一只感煙火災探測器動作后,防護區(qū)內火災聲光警報器動作,排煙閥關閉C.系統(tǒng)收到第二個聯動觸發(fā)信號后,啟動氣體滅火裝置D.手動按下防護區(qū)門外設置手動啟動按鈕,氣體滅火裝置動作,防護區(qū)入口處表示氣體噴灑火災聲警報器動作【答案】B27、某耀州瓷倉庫包裝加瓷器總儲物重量12.5t,總容積65m3,全部采用紙包裝盒包裝,包裝盒總重2.5t,總體積25m3,倉庫內沒有其他物品,該倉庫火災危險性為()A.乙B.丙C.丁D.戊【答案】B28、某多層服裝加工廠房,每層建筑面積12000㎡,按照規(guī)范要求每層可劃為一個防火分區(qū)。根據《建筑設計防火規(guī)范》規(guī)定,其上人平屋頂屋面板耐火極限不應低于()h。A.0.5B.1.0C.1.5D.2.0【答案】C29、除直灌式送風方式外,設置機械加壓送風樓梯間宜()設一個加壓送風口,前室應每層設一個常閉式加壓送風口。A.每隔4~5層B.每隔2~3層C.每隔6~7層D.每層【答案】B30、下列關于機械防排煙系統(tǒng)設計說法錯誤是()。A.火災確認后,火災自動報警系統(tǒng)應在15s內聯動開啟相應防煙分區(qū)全部排煙閥、排煙口B.火災確認后,火災自動報警系統(tǒng)應在15s內聯動相應防煙分區(qū)全部活動擋煙垂壁C.當火災確認后,擔負兩個及以上防煙分區(qū)排煙系統(tǒng),應打開全部防煙分區(qū)排煙閥或排煙口D.當火災確認后,火災自動報數系統(tǒng)應在30s內自動關閉與排煙無關通風、空調系統(tǒng)【答案】C31、Ⅰ級易燃氣體的爆炸下限為()。A.<5%B.<10%C.≦5%D.≧10%【答案】B32、某新建商店建筑,地上5層,地下2層,室內、外設計地面標高均為±0.00m,層高均為5.6m,每層建筑面積為2000m2,首層至地上五層均設有商店營業(yè)廳,地下一層和地下二層設有設備用房,其中地下二層設有汽車庫。下列說法中,錯誤是()。A.該商店建筑地上部分耐火等級不應低于二級B.該商店建筑地下部分應設置封閉樓梯間C.地下一層不應設置柴油發(fā)電機房D.地下二層不應設置消防水泵房【答案】B33、對工業(yè)建筑進行防火檢查時,應注意檢查工業(yè)建筑火災危險性、耐火等級和建筑面積,在檢查下列工業(yè)建筑中,可以采用三級耐火等級是()。A.建筑面積為1500m2金屬冶煉車間B.建筑面積為350m2氨壓縮機房C.蒸發(fā)量為7t/h燃煤鍋爐房D.獨立建造建筑面積為280m2單層制氧車間【答案】D34、有一辦公樓,室外消火栓設計流量為40L/s,那么該辦公樓至少應設置()個室外消火栓。A.2B.3C.4D.5【答案】B35、下列關于低倍數泡沫滅火系統(tǒng)設計要求說法錯誤是()A.在固定式泡沫滅火系統(tǒng)儲罐區(qū),每支輔助泡沫槍泡沫混合液流量不應小于240L/minB.泡沫混合液輸送到保護對象時間不大于5minC.直徑大于45m外浮頂儲罐,需要在儲罐梯子平臺上設置二分水器D.火車裝卸棧臺泡沫混合液量不應小于25L/s【答案】D36、下列關于加油站說法錯誤是()。A.汽車加油站儲油罐,應采用臥式油罐B.汽油罐與柴油罐通氣管應分開設置,通氣管管口高出地面高度不應小于4mC.當采用電纜溝敷設電纜時,加油站內電纜溝內必須充沙填實D.油罐應采取卸油時防滿溢措施,油料達到油罐容量90%時,應能觸動高液位報警裝置,達到油罐容量95%時,應能自動停止油料繼續(xù)進罐【答案】C37、由消防控制室接地板引至各消防電子設備的專用接地線應選用銅芯絕緣導線,其線芯橫截面面積不應小于()平方毫米;消防控制室接地板與建筑接地體之間,應采用線芯截面面積不小于()平方毫米的銅芯絕緣導線連接。A.4,20B.5,20C.4,25D.5,25【答案】C38、(2021真題)系統(tǒng)工作壓力為3.60Mpa細水霧滅火系統(tǒng)為()。A.高壓系統(tǒng)B.低壓系統(tǒng)C.中壓系統(tǒng)D.超高壓系統(tǒng)【答案】A39、下列關于火災探測器選擇正確是()。A.對火災初期有陰燃階段,產生大量煙和少量熱,很少或沒有火焰輻射場所,應選擇感溫火災探測器B.對使用、生產可燃氣體或可燃蒸氣場所,應選擇可燃氣體探測器C.飯店、旅館宜選擇點型感溫火災探測器D.可能產生腐蝕性氣體場所,應選擇點型離子感煙火災探測器【答案】B40、有一寫字樓十層公共部位放有2具滅火器,滅火器銘牌上標注滅火器型號為MF/ABC4,關于該滅火器說法,正確是()。A.該滅火器屬于磷酸銨鹽滅火器B.該滅火器撲救A類火災時滅火級別為3AC.該滅火器屬于推車式滅火器D.該滅火器滅火劑充裝量為4L【答案】A41、下列()內防火墻耐火極限不低于4.00h。A.植物油加工廠房精煉部位B.發(fā)煙硫酸濃縮部位C.硫酸車間焙燒部位D.橡膠制品壓延廠房【答案】B42、消防設施配置對于飛機庫防火至關重要,下列關于飛機庫設置消防設施說法,不正確是()。A.飛機停放和維修區(qū)內排水系統(tǒng)可以采用排水溝,也可以采用地下管道B.消防泵房內設置內燃機采用集中油箱供油時,應設置儲油間C.消防泵房內可以設置自動噴水滅火系統(tǒng)或其他滅火設施D.Ⅰ類飛機庫設置自動噴水滅火系統(tǒng)時,系統(tǒng)作用面積不應大于1400m2【答案】D43、一個容納人數為2800人劇院,其需要設置疏散門個數至少為()。A.10B.12C.13D.14【答案】A44、關于干式自動噴水滅火系統(tǒng),下列敘述不正確是()。A.系統(tǒng)由閉式噴頭、干式報警閥組、水流指示器、充氣設備、管道、火災自動報警系統(tǒng)和供水設施等組成B.系統(tǒng)啟動原理與濕式系統(tǒng)相似,只是將傳輸噴頭開放信號介質由有壓水改為有壓氣體C.在準工作狀態(tài)時,由消防水箱或穩(wěn)壓泵、氣壓給水設備等穩(wěn)壓設施維持干式報警閥入口前管道內充水壓力D.閉式噴頭動作后,可由壓力開關動作信號,直接啟動噴淋消防泵,聯動控制不受消防聯動控制器處于自動或手動狀態(tài)影響【答案】A45、老年人建筑及托兒所、幼兒園兒童用房、兒童游樂廳等兒童活動場所宜設置在獨立建筑內。當必須設置在其它高層民用建筑內時()。A.可不設置獨立安全出口B.宜設置獨立安全出口C.應設置獨立安全出口D.應設置直通樓梯出口【答案】C46、某LPG加氣站為三級站,周邊有一耐火等級為一級、高48m綜合樓,綜合樓面向加氣站一側墻為無門、窗、洞口實體墻,則兩者之間防火間距應不小于()m。A.50B.70C.100D.120【答案】B47、在規(guī)定試驗條件下,物質在外部引火源作用下表面起火并持續(xù)燃燒一定時間所需最低溫度,稱為()A.自燃點B.閃點C.自燃D.燃點【答案】D48、下列有關自動噴水滅火系統(tǒng)的說法,錯誤的是()。A.每個報警閥組控制的最不利點灑水噴頭處應設末端試水裝置B.每個報警閥組供水的灑水噴頭距報警閥的高度不宜大于50mC.雨淋系統(tǒng)的防護區(qū)內應采用相同的灑水噴頭D.閉式系統(tǒng)的灑水噴頭,其公稱動作溫度宜高于環(huán)境最高溫度30°C【答案】B49、某寫字樓建筑高度68m,每層建筑面積4000㎡,下列關于其消防電梯設置,正確是()。A.該建筑設置1部消防電梯,2部普通電梯B.消防電梯前室矩形尺寸為5m×2mC.消防電梯井與相鄰電梯井之間設置2.00h防火隔墻D.消防電梯排水泵排水量為5L/s【答案】C50、下列對于采用臨時高壓消防給水系統(tǒng)高位消防水箱設置正確的是()。A.某商店建筑高度90m,建筑面積45000m2,高位消防水箱有效容積為36m3B.某辦公樓高度120m,高位消防水箱有效容積50m3,最低有效水位距最不利點消火栓垂直距離為10m,未設穩(wěn)壓設施C.某工業(yè)建筑室內消防給水設計流量為25L/s,高位消防水箱有效容積12m3D.某住宅建筑高度55m,高位消防水箱有效容積12m3,最低有效水位距最不利點噴頭垂直距離為7m,未設穩(wěn)壓設施【答案】C多選題(共25題)1、甲雇乙粉刷樓房外墻。乙工作時,丙駕駛的摩托車失控撞向腳手架,致乙從腳手架上跌落,摔成重傷。乙對自己的損害()。A.只能要求甲承擔賠償責任B.只能要求丙承擔賠償責任C.可以要求甲、丙承擔按份責任D.可以要求甲、丙承擔連帶責任【答案】D2、下列關于水幕系統(tǒng)敘述正確是()。A.由開式灑水噴頭或水幕噴頭、雨淋報警閥組或感溫雨淋閥以及水流報警裝置(水流指示器或壓力開關)等組成,用于擋煙阻火和冷卻分隔物噴水系統(tǒng)B.水幕系統(tǒng)使用雨淋閥組可以不設水力警鈴和延遲器C.防火分隔水幕不宜用于尺寸超過15m(寬)×8m(高)開口(舞臺口除外)D.水幕系統(tǒng)雨淋閥組可以向一個保護對象或多處防火分隔空間噴水E.水幕系統(tǒng)噴水與報警閥動作關系為報警閥先動作,噴頭隨報警閥開放而噴水【答案】AC3、根據《建筑設計防火規(guī)范》,當裙房與高層建筑主體之間采用防火墻完全分隔時,裙房可以按單多層建筑的要求進行防火設計的是()。A.防火分區(qū)B.內部裝修C.消防設施D.耐火等級E.疏散樓梯間【答案】A4、可燃粉塵爆炸應具備條件,下列正確條件是()。A.粉塵本身具有可燃性,且能發(fā)生爆炸B.粉塵必須懸浮在空氣中并與空氣混合到爆炸濃度C.有足以引起粉塵爆炸火源D.粉塵必須與空氣混合到爆炸濃度E.空氣中含水量較高【答案】ABC5、Text1InJanuarycommutersvotedBirminghamNewStreetoneofBritain'sworstrailwaystations.Eachdaynearly150.000peoplemovethroughastructurebuiltforhalfasmany.Butbynextyearitwillbetransformed.with400tonnesofundulatingsteelcladdingandavaguelyeyeballappearance.Thestationwillhave"thewowfactor",boastsSirAlbertBore,theleaderofBirminghamcitycouncil.Itwillalsoshowhowmuchattitudestorailwaystationshavechanged.RailxvaystationsarethechiefexceptiontotherulethatBritaininveststoolittleininfrastructure.OftheI7bigterminimanagedbyNetworkRail,theownerofBritain'stracks,11arebeingredevelopedorhaverecentlybeencompleted.Fiveotherstations,includingReadingandNorthampton,arebeingsprucedupbylocalcouncilsandNetworkRail.Somcsimplyneedtobeexpanded:thenumberoftrainjourneyshasrisenby35%since2005.ButthedesignofNewStreetsuggestsaspirationswellbeyondmoreeasefultravel.ThebuildingwouldnotlookoutofplaceinDubaiandisstriking,ifslightlyincongruous,inthegreyWestMidlands.Cityplannerswantedsomethingmonumental,likeGrandCentralstationinNewYork,saysSirBernardZissman,chaimanoftheindependentdesignpaneL"Twentyorthirtyyearsagobusinesspeopleweremorelikelytoarriveinacitybycar,"explainsJonNealeofJonesLangLaSatle,apropertyspecialist.Townplannersdulycarvedoutmotorwaysandroundaboutstoenticethem.In1962alocalpoliticianclaimedthatanewdesignforBirmingham,involvinganinnerringroad,wouldmakeit"oneofthefinestcitycentresinEurope".Citiesnowmeasuretheirappealbytheirstations.Businessesclusteraroundthem:atKing'sCross,aonce-grimypartofnorthLondon,apostcodehasbeencreatedforallthenewbuildingsaroundthestation,whichwasredevelopedin2013.JohnLewis,anupmarketdepartmentstore,willopeninthemallaboveNewStreet(whichisindeedcalled"GrandCentral")alongwith600thershops.Thecouncilhopesitwillpullinvisitorstothecity.Suchambitionrecallsthestationsofthe19thcentury.Thosestructures"spoketothecorporatesensibilityofacity,"saysTristramHunt,anMPandhistorian,bycombiningcommercewiththesheenofcivicpride.ThefirstNewStreetstation,builtin1851,hadthelargestsingle-spanroofinthecountryatthetime.Itwastomdownbyenthusiastic1960stownplanners.Nowsomeofitsoriginallustremayretum.A.TheNewConceptofRailwayStationB.ABigFailureofRailwayStationC.AFeverishDreamofRailwayStationD.ACitizen'sPlanningofRailwayStation【答案】A6、某建筑采用防火墻劃分防火分區(qū),下列防火墻設置中,錯誤是()。A.只要滿足耐火極限要求,防火墻直接從地面開始砌筑到樓板或屋面板抹灰層底即可B.高層廠房屋面板耐火極限低于1.00h時,防火墻隔斷至屋面板底面基層C.防火墻中心距天窗端面水平距離為3m,且天窗端面為不燃性墻體時,不需再采取其他防止火勢蔓延設施D.建筑外墻為不燃性墻體時,防火墻可不凸出墻外表面,當采用乙級防火窗時,緊靠防火墻兩側門、窗、洞口之間最近邊緣水平距離不限E.建筑物內防火墻如設在轉角附近,內轉角兩側上乙級防火窗之間最近水平距離不限(F)設計防火墻時,應考慮防火墻一側屋架、梁、樓板等受到火災影響而破壞時,不致使防火墻倒塌【答案】AB7、設置防煙分區(qū)時除了不應跨越防火分區(qū)之外還應滿足()。A.防煙分區(qū)應采用擋煙垂壁、隔墻、結構梁等劃分B.每個防煙分區(qū)的建筑面積不宜超過規(guī)范要求C.采用隔墻等形成封閉的分隔空間時,該空間宜作為一個防煙分區(qū)D.儲煙倉高度不應小于空間凈高的10%,且不應小于500mm,同時應保證疏散所需的清晰高度E.有特殊用途的場所可集中劃分防煙分區(qū)【答案】ABCD8、由于場地等原因,防火間距難以滿足國家有關消防技術標準要求,可根據建筑物實際情況,采取一系列消防技術措施進行補救,其中包括()。A.將建筑普通外墻改為防火墻B.設置獨立室外防火墻C.設置相應消防設施D.該變建筑生產和使用性質E.減少建筑防火分區(qū)面積【答案】ABD9、某綜合樓地上21層,地下3層,建筑高度為68m,采用鋼筋混凝土結構,耐火等級為一級,其中1-4層為商業(yè)賣場,5層為KTV、酒吧,6層為電影院,7-12層為大型企業(yè)集中辦公區(qū),12-21層為公寓式寫字樓,該建筑按照相關規(guī)范要求設置了相應消防設施。下列關于該建筑安全疏散說法正確是()。A.位于該建筑3層某服裝賣場營業(yè)廳(設有2個安全出口)其室內任一點室最近安全出口距離為50mB.該建筑5層酒吧位于袋行走道盡端,該酒吧面積為60㎡設置一個疏散門,該疏散門至防煙樓梯間距離為10mC.位于6層電影院通過該建筑4部防煙樓梯間進行疏散,電影院任一疏散門至安全出口距離均滿足規(guī)范要求D.18層位于疏散走道盡端辦公室建筑面積為120㎡設置一個疏散門,該疏散門至最近疏散樓梯疏散距離為25mE.位于8層集中辦公區(qū)采用開敞式辦公(設有2個安全出口),該辦公區(qū)位于兩個疏散樓梯間之間,辦公區(qū)內任一點至最近安全出口疏散距離為47m【答案】A10、甲因侵占科研經費被捕。在偵查期間,甲主動供述自己曾和同事一起套取另一科研項目經費19萬元用于自己房屋裝修。甲供述與他人套取科研經費的行為屬于()。A.坦白B.立功C.自首D.準自首【答案】A11、下列情況可不設置消防電梯是()。A.建筑高度大于32m且設置電梯,任一層工作平臺上人數不超過2人高層塔架B.局部建筑高度大于32m,且局部高出部分每層建筑面積不大于50m2丁、戊類廠房C.建筑高度大于33m住宅建筑D.一類高層公共建筑和建筑高度大于32m二類高層公共建筑E.設置消防電梯建筑地下或半地下室,埋深大于10m且總建筑面積大于3000m2其他地下或半地下建筑(室)【答案】AB12、下列關于建筑內應急照明和疏散指示標志備用電源連續(xù)供電時間說法,正確有()。A.某建筑高度為15m醫(yī)院,備用電源連續(xù)供電時間不應小于60分鐘B.某綜合辦公樓建筑高度120m,備用電源連續(xù)供電時間不應小于180分鐘C.建筑高度為85m綜合樓,地上21層,每層建筑面積4800m2,備用電源連續(xù)供電時間不應小于60分鐘D.總建筑面積為110000m2博物館,備用電源連續(xù)供電時間不應小于90分鐘E.總建筑面積為19000m2地下商場,備用電源連續(xù)供電時間不應小于60分鐘【答案】AC13、建筑發(fā)生火災時,煙氣流動方向通常是火勢蔓延一個主要方向。下列關于建筑火災煙氣蔓延說法中正確是()。A.煙氣在水平方向擴散流動速度小于在垂直方向擴散流動速度,樓梯間或管道豎井中煙氣上升流動速度最小B.高層建筑發(fā)生火災時最主要煙氣流動擴散路線是著火房間→走廊→樓梯間→上部各樓層→室外C.火風壓是指起火房間內由于壓力上升,氣體迅速膨脹,對樓板和墻壁形成壓力D.外界風存在可在建筑物周圍產生壓力分布,背風側產生較高滯止壓力,增強建筑內煙氣向下風向流動E.室內煙氣蔓延途徑包括孔洞開口蔓延、穿越墻壁管線和縫隙蔓延、悶頂內蔓延【答案】B14、某大型石油化工企業(yè)內設有工藝裝置區(qū)、液化烴罐組區(qū)、可燃液體罐組區(qū),全廠性高架火炬等。該企業(yè)總平面布置的下列設計方案中,正確的是()。A.在液化烴罐組防火堤內種植生長高度不超過15cm、含水分多的四季常青的草皮B.將消防站布置在生產區(qū)全年最小頻率風向的上風側C.廠區(qū)內消防車道路面寬度為5m,路面上凈空高度為6mD.將工藝裝置區(qū)布置在人員集中場所的全年最小頻率風向的上風側E.將可燃液體罐組毗鄰布置在高于工藝裝置的平臺上,并嚴格采取了防止泄漏流散的措施【答案】D15、關于建筑安全疏散的說法,下列選項中正確的有()。A.疏散走道在防火分區(qū)處應設置常開甲級防火門B.民用建筑和廠房的疏散門,應采用向疏散方向開啟的平開門,不應采用推拉門、卷簾門、吊門、轉門和折疊門C.建筑面積為1000㎡的服裝倉庫,在首層靠墻內側設置2個凈寬3m的卷簾門D.位于走道兩側的一間會議室,建筑面積為200㎡,核定人數為65人,設置2樘凈寬為1.2m并向房間內開啟的疏散門E.設置門禁系統(tǒng)的公寓建筑的外門,應保證火災時不需使用鑰匙等任何工具即能從內部易于打開【答案】AB16、下列關于消防給水設施說法不正確是()。A.消防水泵直接從市政管網直接吸水時,應在消防水泵出水管上設置有空氣隔斷倒流防止器B.消防水泵吸水管布置應避免形成氣囊,吸水管變徑連接時采用同心異徑管必須采用管頂平接C.環(huán)狀管道應采用閥門分成若干獨立段,每段內室外消火栓數量不宜超過3個D.消防給水系統(tǒng)管網正常泄漏量應根據管道材質、接口形式等確定,當沒有管網泄漏量數據時,穩(wěn)壓泵設計流量宜按消防給水設計流量1%~3%計,且不宜小于1L/sE.穩(wěn)壓泵吸水管應設置消聲止回閥和明桿閘閥,穩(wěn)壓泵出水管應設置明桿閘閥【答案】BC17、我國專利法對發(fā)明和實用新型采用的新穎性標準是()。A.絕對新穎性標準B.絕對新穎性為主,相對新穎性為補充C.相對新穎性標準D.相對新穎性為主,絕對新穎性為補充【答案】A18、消防技術人員對某工業(yè)區(qū)進行消防檢查,下列僅設置一個安全出口生產場所中,符合安全出口設置要求場所有()。A.某甲類廠房,每層建筑面積120m2,同一時間作業(yè)人數3人B.某戊類廠房,每層建筑面積300m2,同一時間作業(yè)人數24人C.某丁類廠房,每層建筑面積350m2,同一時間作業(yè)人數20人D.某乙類廠房,每層建筑面積180m2,同一時間作業(yè)人數8人E.某丙類廠房,每層建筑面積260m2,同一時間作業(yè)人數18人【答案】BC19、Text1"Theloveofmoney",StPaulmemorablywrotetohisprotegeTimothy,"istherootofallevil.""All"maybeputtingitabitstrongly,butdozensofpsychologicalstudieshaveindeedshownthatpeopleprimedtothinkaboutmoneybeforeanexperimentaremorelikelytolie,cheatandstealduringthecourseofthatexperiment.Anotherwell-knownaphorism,ascribedtoBenjaminFranklin,is"timeismoney".Iftrue,thatsuggestsasyllogism:thattheloveoftimeisarootofevil,too.ButapaperjustpublishedinPsychologicalSciencebyFrancescaGinoofHarvardandCassieMogilneroftheUniversityofPennsylvaniasuggestspreciselytheopposite.DrGinoandDrMogilneraskedagroupofvolunteerstodoascriesofwhatappearedtobeaptitudetests.Asisofienthecaseinsuchexperiments,though,whatthevoiunteersweretold.andwhatthetruthwas,wereratherdifferentthings.Inthefirsttesttheywereaskedtomake,withinthreeminutes,asmanycoherentsentencesastheycouldoutofasetofwordstheyhadbeenpresentedwith.Whattheywerenottoldwasthateachofthemhadbeenassignedtooneofthreegroups.Somevolunteers'wordsetswereseededwithonesassociatedwithmoney,suchas"dollars","financing"and"spend".Somewereseededwithwordsassociatedwithtime(eg,"clock",/'hours","moment").Andsomewereseededwithneither.Thusunknowinglyprimed,thevolunteerswerereadyforthesecondtest.Thiswasmathematical.Theyweregivenasheetofpaperwith20matriceswhicheachcontained12numbers.twoofwhichaddeduptoten(forexample,3.81and6.19).Theyhadtowritedown,onaseparateanswersheet,howmanyofthesepairstheycouldmanagetofindinfiveminutes.Theywerealsogivenapacketofmoneyandtoldtheycouldrewardthemselveswithadollarforeachpairtheydiscovered.ThisledDrGinoandDrMogilnertosuspectthatself-reflectionplayedapartincontrollinguncthicalbehaviourduringthetest.Theythereforeconductedathirdtestinwhich,forhalfthevolunteers,therewasamirrorinthecubicletheyweresittinginwhendoingtheexperiment.Volunteersprimedtothinkaboutmoneycheated39%ofthetimewhenamirrorwaspresentbut67%whenitwasnot.Thoseprimedtothinkabouttimecheated32%ofthetimeinthepresenceofthemirrorand36%initsabsence-resultsthatarestatisticallyindistinguishable.Finally,afourthexperimentaskedprimedvolunteerstofillinaquestionnairebeforetacklingthematrix.Inamong"filler"questionsintendedtodisguisewhatwashappeningthisaskedthemtoratehowtheyfeltaboutself-reflectivestatementslike,"Rightnow,1amthinkingaboutwhoIamasaperson."
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 山西省2024七年級道德與法治上冊第二單元成長的時空第四課幸福和睦的家庭情境基礎小練新人教版
- 2025年臨時租房協(xié)議考研范文(2篇)
- 2025年倉儲租賃合同例文(三篇)
- 游戲廳裝修工程協(xié)議
- 主題公園商鋪居間合同
- 體育館裝修施工合同協(xié)議書
- 鹽田古典聲學裝修施工方案
- 機場候機廳墻面裝修協(xié)議
- 木材短途運輸協(xié)議
- 服裝店內部裝修項目協(xié)議
- 父母贈與協(xié)議書
- 2025節(jié)后復工安全工作重點(培訓課件)
- 員工之愛崗敬業(yè)培訓課件1
- 高校鑄牢中華民族共同體意識教育的路徑研究
- 《宗教與文化》課件
- 醫(yī)療機構依法執(zhí)業(yè)自查管理辦法
- 《個人所得稅征管問題及對策研究》
- 2020-2024年五年高考歷史真題分類匯編(全國)專題14 中國古代史(非選擇題)(原卷版)
- JGJT46-2024《施工現場臨時用電安全技術標準》條文解讀
- 2022年云南省公務員錄用考試《申論》真題(縣鄉(xiāng)卷)及答案解析
- 大學輔導員崗位考核參考指標
評論
0/150
提交評論