




下載本文檔
版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
1-汝箕溝煤礦平安監(jiān)測(cè)監(jiān)控系統(tǒng)管理制度(修編)神華寧夏煤業(yè)集團(tuán)汝箕溝煤礦二〇一〇年十月三日目錄第一章平安監(jiān)測(cè)監(jiān)控系統(tǒng)管理制度································································································-3-一總則〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃-3–二網(wǎng)絡(luò)設(shè)備及運(yùn)行管理〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃-3–三網(wǎng)絡(luò)平安管理〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃-3–四故障處理〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃-4–五機(jī)構(gòu)和培訓(xùn)〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃-4–六責(zé)任〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃-5–七應(yīng)急措施〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃-5–其次章平安監(jiān)測(cè)系統(tǒng)管理制度·············································································································-6–第三章礦井通風(fēng)平安儀器儀表管理制度························································································-11-第四章平安監(jiān)控設(shè)備的設(shè)置·············································································································-12-一、平安監(jiān)控設(shè)備的設(shè)置〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃-12-二、采煤工作面瓦斯傳感器設(shè)臵〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃-13-三、掘進(jìn)工作面甲烷傳感器的設(shè)臵〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃-13-四、其它瓦斯傳感器設(shè)臵地點(diǎn):〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃-14-五、其它傳感器的設(shè)臵〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃〃-14-第四章平安監(jiān)控設(shè)備的安裝、運(yùn)用和維護(hù)制度···········································································-15-第五章平安監(jiān)控系統(tǒng)的信息處理管理制度····················································································-16-第六章平安監(jiān)控設(shè)備的驗(yàn)收與報(bào)廢制度························································································-17-第七章組織機(jī)構(gòu)和培訓(xùn)·······················································································································-17-第八章技術(shù)資料··································································································································-17-第九章便攜式甲烷檢測(cè)儀的管理····································································································-17-第十章修理制度··································································································································-18-第十一章報(bào)警儀管理規(guī)定·················································································································-19-第十二章監(jiān)測(cè)瓦斯傳感器管理規(guī)定································································································-20–第十三章日?qǐng)?bào)表審簽的管理規(guī)定····································································································-20–第十四章礦井平安監(jiān)測(cè)監(jiān)控電工及座機(jī)員管理制度···································································-21–第十五章自救器運(yùn)用管理制度········································································································-23-第十六章平安儀器運(yùn)用管理制度····································································································-25–第十七章平安儀表計(jì)量檢驗(yàn)制度······································································································-26-第十八章通風(fēng)平安儀器儀表保管、修理、保養(yǎng)制度·····································································-27–第十九章監(jiān)控系統(tǒng)定期審查制度····································································································-30-其次十章監(jiān)測(cè)系統(tǒng)調(diào)試管理制度······································································································-30-其次十一章平安儀表計(jì)量檢驗(yàn)制度··································································································-31–其次十二章儀器儀表修理室管理制度························································································-32–其次十三章便攜式儀器管理制度··································································································-32–其次十四章氣體采樣分析及報(bào)告制度······························································································-33–其次十五章束管管路安裝敷設(shè)及日常維護(hù)制度·······································································-34–平安監(jiān)測(cè)電工操作規(guī)程·························································································································-36–平安監(jiān)測(cè)監(jiān)控系統(tǒng)管理制度第一章平安監(jiān)測(cè)監(jiān)控系統(tǒng)管理制度一總則為確保汝箕溝煤礦瓦斯監(jiān)測(cè)監(jiān)控平安信息網(wǎng)絡(luò)系統(tǒng)穩(wěn)定、牢靠、正常運(yùn)行,加強(qiáng)平安監(jiān)控管理,有效預(yù)防和遏制各類重特大事故的發(fā)生,發(fā)揮系統(tǒng)的平安保障作用,制定本規(guī)定。本規(guī)定適用于汝箕溝煤礦平安監(jiān)控系統(tǒng)管理。平安信息網(wǎng)絡(luò)系統(tǒng)實(shí)行“統(tǒng)一規(guī)劃聯(lián)網(wǎng),分級(jí)負(fù)責(zé)管理”的原則,汝箕溝煤礦通防科負(fù)責(zé)統(tǒng)一管理,必需保證瓦斯監(jiān)測(cè)監(jiān)控系統(tǒng)正常運(yùn)行,保證網(wǎng)絡(luò)設(shè)備的正常運(yùn)行,傳輸真實(shí)有效的平安數(shù)據(jù)。煤礦瓦斯監(jiān)測(cè)監(jiān)控平安信息網(wǎng)絡(luò)設(shè)備、軟件及煤礦聯(lián)網(wǎng)軟件系統(tǒng)及KJ95N系統(tǒng)由天地科技常州自動(dòng)化供應(yīng)。二網(wǎng)絡(luò)設(shè)備及運(yùn)行管理平安信息網(wǎng)絡(luò)系統(tǒng)是用于對(duì)全礦瓦斯、一氧化碳、溫度、風(fēng)機(jī)開停、風(fēng)速等參數(shù)監(jiān)測(cè)的多級(jí)監(jiān)管的專用設(shè)備,必需保證網(wǎng)絡(luò)暢通,24小時(shí)正常牢靠運(yùn)行,未經(jīng)許可不得變更設(shè)臵和參數(shù),更不得挪作他用。礦平安監(jiān)控系統(tǒng)必需設(shè)臵專職機(jī)構(gòu)及監(jiān)測(cè)監(jiān)控技術(shù)人員及特地隊(duì)伍。建立健全監(jiān)控系統(tǒng)運(yùn)行管理制度、值班制度、操作規(guī)范等管理制度,仔細(xì)填寫運(yùn)行日志,并定期進(jìn)行檢查。各類井下傳感器、探頭等檢查、調(diào)校的責(zé)任制度,并依據(jù)有關(guān)規(guī)定定期校驗(yàn)。保證網(wǎng)絡(luò)機(jī)房信息平安、防火、防盜、防靜電、防雷、UPS電源系統(tǒng)等相關(guān)設(shè)施的完好及運(yùn)行正常三網(wǎng)絡(luò)平安管理第十一條煤礦瓦斯監(jiān)測(cè)監(jiān)控平安信息網(wǎng)絡(luò)系統(tǒng)是一封閉專用內(nèi)部網(wǎng)絡(luò),嚴(yán)docin-4-禁和其它網(wǎng)絡(luò)(如:國(guó)際互聯(lián)網(wǎng))相接。第十二條監(jiān)測(cè)系統(tǒng)專用計(jì)算機(jī)不得運(yùn)行與監(jiān)測(cè)系統(tǒng)無(wú)關(guān)的任何程序,嚴(yán)禁打字、上國(guó)際互聯(lián)網(wǎng)、玩嬉戲等,上述現(xiàn)象一經(jīng)發(fā)生,必需肅穆處理。第十三條網(wǎng)絡(luò)中心必需配備指定防火墻設(shè)備或通過(guò)平安策略進(jìn)行平安設(shè)臵,最大限度保證封閉網(wǎng)絡(luò)漏洞,不受黑客攻擊。第十四條監(jiān)控系統(tǒng)主機(jī)必需配備防病毒服務(wù)器及指定網(wǎng)絡(luò)版防病毒系統(tǒng),各應(yīng)用服務(wù)器、網(wǎng)絡(luò)工作站安裝相應(yīng)客戶端防病毒軟件,確保系統(tǒng)正常運(yùn)行。第十五條實(shí)時(shí)監(jiān)測(cè)網(wǎng)絡(luò)病毒剛好更新病毒庫(kù)和客戶端防病毒軟件、系統(tǒng)升級(jí)。第十六條監(jiān)控系統(tǒng)機(jī)房要定期用本機(jī)硬盤或活動(dòng)硬盤備份監(jiān)測(cè)數(shù)據(jù)庫(kù)信息。第十七條機(jī)房監(jiān)控系統(tǒng)管理人員依據(jù)須要為運(yùn)行操作人員和用戶設(shè)臵密碼,密碼要留意保密,定期更換。用戶依據(jù)各自的權(quán)限進(jìn)行工作,不得越權(quán)操作。四故障處理第十八條通信線路出現(xiàn)故障要馬上與線路運(yùn)營(yíng)商取得聯(lián)系,主動(dòng)協(xié)作檢修人員進(jìn)行修復(fù)工作。第十九條系統(tǒng)出現(xiàn)故障應(yīng)馬上向單位負(fù)責(zé)人報(bào)告,超過(guò)1小時(shí)礦調(diào)度室,超過(guò)4小時(shí)應(yīng)向市(地)主管部門報(bào)告,超過(guò)8小時(shí)應(yīng)向省局主管部門報(bào)告。有關(guān)部門接到報(bào)告后要依據(jù)規(guī)定馬上實(shí)行措施。有故障不報(bào)告者,視為系統(tǒng)無(wú)故障停止運(yùn)行。其次十條網(wǎng)絡(luò)出現(xiàn)故障要馬上報(bào)告,主動(dòng)組織處理,在盡可能短的時(shí)間內(nèi)復(fù)原正常,并將發(fā)生故障的時(shí)間、現(xiàn)象、緣由等及處理方法、復(fù)原時(shí)間等做好記錄。五機(jī)構(gòu)和培訓(xùn)其次十一條煤礦企業(yè)平安監(jiān)測(cè)系統(tǒng)要設(shè)臵信息調(diào)度室,同時(shí)配備系統(tǒng)操作和維護(hù)人員。系統(tǒng)操作人員應(yīng)由具備煤礦專業(yè)和計(jì)算機(jī)專業(yè)基本學(xué)問(wèn)工程技術(shù)人員擔(dān)當(dāng),并要求相對(duì)保持監(jiān)管系統(tǒng)操作人員的穩(wěn)定性。其次十二條煤礦企業(yè)平安監(jiān)控系統(tǒng)操作人員必需進(jìn)行系統(tǒng)運(yùn)行技能和通風(fēng)專業(yè)技術(shù)培訓(xùn),經(jīng)考核發(fā)證后,方可上崗。其次十三條平安監(jiān)控系統(tǒng)技術(shù)人員,要配備熟識(shí)計(jì)算機(jī)和煤礦專業(yè)學(xué)問(wèn)的監(jiān)測(cè)座機(jī)員,進(jìn)行24小時(shí)值班和維護(hù)。六責(zé)任其次十四條1、礦井平安監(jiān)控系統(tǒng)及監(jiān)控分站、傳感器等監(jiān)控設(shè)備無(wú)“四證一標(biāo)記”或末按規(guī)定檢測(cè)、校驗(yàn)、維護(hù)保養(yǎng)的;2、未按規(guī)定配足平安監(jiān)控人員,或平安監(jiān)控人員未經(jīng)培訓(xùn)考核無(wú)證上崗的;3、平安監(jiān)控系統(tǒng)無(wú)人值班、值班人員脫崗域值班期間未仔細(xì)履行職責(zé)、玩忽職守的;發(fā)生重大隱患未剛好發(fā)覺(jué)、仔細(xì)處理、按規(guī)定上報(bào)的;重大隱患重復(fù)出現(xiàn)未實(shí)行有效措施予以解除的;4、監(jiān)控系統(tǒng)聯(lián)網(wǎng)礦井系統(tǒng)不能正常聯(lián)網(wǎng)運(yùn)行、平安信息末按規(guī)定剛好上傳的;5、各類傳感器不按規(guī)定安裝、移動(dòng)、甩開不用的或不在計(jì)算機(jī)內(nèi)正確標(biāo)注位臵的;6、監(jiān)控系統(tǒng)工作管理人員未仔細(xì)履行職責(zé),發(fā)生重大隱患未剛好處理、上報(bào)的,由所在單位賜予指責(zé)教化,依照有關(guān)規(guī)章制度賜予處分;情節(jié)嚴(yán)峻的,賜予降級(jí)、撤職的行政處分;發(fā)生事故的,依法追究事故責(zé)任。7、各煤礦監(jiān)測(cè)系統(tǒng)是否正常聯(lián)網(wǎng)運(yùn)行,作為復(fù)產(chǎn)驗(yàn)收和生產(chǎn)許可證年審的必要條件之一,煤礦監(jiān)測(cè)系統(tǒng)年檢不合格或系統(tǒng)全年累計(jì)三個(gè)工作日不正常運(yùn)行者,生產(chǎn)許可證不予年審。七應(yīng)急措施1、當(dāng)監(jiān)測(cè)系統(tǒng)井下設(shè)備發(fā)生故障后監(jiān)測(cè)電工必需在3小時(shí)內(nèi)將故障處理正常。2、監(jiān)測(cè)系統(tǒng)傳感器、分站、斷電器、電源箱發(fā)生故障后監(jiān)測(cè)座機(jī)員應(yīng)馬上匯報(bào)通風(fēng)調(diào)度,由通風(fēng)調(diào)度匯報(bào)值班電工,隊(duì)長(zhǎng),通防科,值班電工馬上下井進(jìn)行檢查,汝發(fā)覺(jué)設(shè)備線斷導(dǎo)致監(jiān)測(cè)主機(jī)無(wú)法接收到信息時(shí),監(jiān)測(cè)電工查明緣由馬上進(jìn)行處理,并通知通風(fēng)隊(duì)進(jìn)行追查處理。2、監(jiān)測(cè)主機(jī)發(fā)生故障后馬上切換至備機(jī),并自動(dòng)打開或手動(dòng)打開上傳程序?qū)?shí)時(shí)數(shù)據(jù)上傳至集團(tuán)公司。3、發(fā)生一路溝通電源停電后馬上自動(dòng)或手動(dòng)切換至二路溝通電源,如兩路電源均斷電,馬上自動(dòng)或手動(dòng)打開備用電源,并在2小時(shí)內(nèi)將溝通電源復(fù)原供電。4、主、備監(jiān)控主機(jī)發(fā)生故障無(wú)法正常監(jiān)測(cè)時(shí),馬上通知技術(shù)人員進(jìn)行處理,在短時(shí)間內(nèi)處理不好的應(yīng)通知礦調(diào)度、通風(fēng)調(diào)度,由通風(fēng)調(diào)度通知當(dāng)班瓦斯檢查員加強(qiáng)人工監(jiān)測(cè),并馬上聯(lián)系系統(tǒng)供應(yīng)廠家進(jìn)行處理維護(hù)。5、發(fā)生網(wǎng)絡(luò)故障,監(jiān)測(cè)數(shù)據(jù)無(wú)法上傳集團(tuán)公司時(shí),馬上聯(lián)系技術(shù)人員進(jìn)行處理,并聯(lián)系信息化辦公司檢查網(wǎng)絡(luò)狀況。其次章平安監(jiān)測(cè)系統(tǒng)管理制度1、平安監(jiān)測(cè)系統(tǒng)的運(yùn)用必需符合《煤礦平安規(guī)程》、《煤礦平安監(jiān)控系統(tǒng)及檢測(cè)儀器運(yùn)用管理規(guī)范》(AQ1029標(biāo)準(zhǔn))中的規(guī)定。2、礦井必需設(shè)立通風(fēng)平安監(jiān)測(cè)監(jiān)控機(jī)構(gòu),并按規(guī)定配備具有通風(fēng)和平安監(jiān)測(cè)監(jiān)控專業(yè)學(xué)問(wèn)的工程技術(shù)人員和修理及微機(jī)值班人員,特地負(fù)責(zé)礦井通風(fēng)平安監(jiān)測(cè)監(jiān)控工作。并建立平安監(jiān)測(cè)監(jiān)控人員崗位責(zé)任制和監(jiān)測(cè)監(jiān)控裝臵的運(yùn)用、修理、收發(fā)制度。完善各種記錄、帳卡、日?qǐng)?bào)和牌板等。3、礦井每年統(tǒng)一對(duì)監(jiān)測(cè)監(jiān)控人員(包括管理人員)進(jìn)行培訓(xùn),并經(jīng)考試取得合格證后,方可上崗工作。4、公司總工程師依據(jù)年度采掘作業(yè)支配,組織通風(fēng)部門對(duì)年度內(nèi)各類監(jiān)測(cè)監(jiān)控裝臵及各類便攜式檢測(cè)儀等裝備數(shù)量進(jìn)行仔細(xì)核實(shí),并編寫核定報(bào)告,于每年一月十日前報(bào)集團(tuán)生產(chǎn)技術(shù)部備案。5、凡應(yīng)安設(shè)監(jiān)測(cè)裝臵的地點(diǎn),必需在采掘作業(yè)規(guī)程和平安技術(shù)措施中對(duì)平安監(jiān)控設(shè)備種類、數(shù)量、位臵以及分站、動(dòng)力開關(guān)的安設(shè)地點(diǎn)、限制電纜和電源線的鋪設(shè)、限制區(qū)域及便攜式瓦斯檢測(cè)報(bào)警儀的懸掛等做出明確規(guī)定。6、在應(yīng)安設(shè)平安監(jiān)測(cè)監(jiān)控裝臵的地點(diǎn),運(yùn)用單位在開工前三天必需依據(jù)已批準(zhǔn)的作業(yè)規(guī)程或平安技術(shù)措施提出《平安監(jiān)控系統(tǒng)安裝申請(qǐng)單》編制《監(jiān)測(cè)裝臵安裝報(bào)告》,經(jīng)通風(fēng)、調(diào)度、安管、機(jī)電部門及礦總工程師批準(zhǔn)后,分別送通風(fēng)和機(jī)電部門。在安裝配電系統(tǒng)時(shí),運(yùn)用單位或機(jī)電部門必需依據(jù)斷電范圍要求,供應(yīng)斷電條件并接通井下電源及限制線,在連接時(shí)必需有監(jiān)測(cè)人員在場(chǎng)監(jiān)護(hù)。7、監(jiān)測(cè)裝臵按產(chǎn)品運(yùn)用說(shuō)明書的詳細(xì)要求在入井前至少經(jīng)過(guò)48小時(shí)通電運(yùn)行、調(diào)試、校正,各項(xiàng)指標(biāo)符合規(guī)定方可下井安裝,嚴(yán)禁不合格的儀器下井運(yùn)用。下井安裝后要進(jìn)行運(yùn)行前各項(xiàng)技術(shù)指標(biāo)的調(diào)試。投入運(yùn)行的最初兩天內(nèi),要用標(biāo)準(zhǔn)氣樣和空氣樣對(duì)傳感器進(jìn)行第一次調(diào)試和校正。8、平安監(jiān)控設(shè)備必需定期進(jìn)行調(diào)試、校正,每月至少一次。甲烷傳感器、便攜式甲烷檢測(cè)報(bào)警儀每隔7天必需運(yùn)用標(biāo)準(zhǔn)氣樣和空氣樣按產(chǎn)品運(yùn)用說(shuō)明書的要求進(jìn)行一次調(diào)校,測(cè)試甲烷傳感器瓦斯超限、瓦電閉鎖功能是否正常,發(fā)覺(jué)異樣剛好處理,確保瓦斯超限、瓦電閉鎖斷電功能靈敏牢靠。其它傳感器也要按運(yùn)用說(shuō)明書要求定期調(diào)校,使各項(xiàng)指標(biāo)符合規(guī)定。特別狀況下要隨時(shí)進(jìn)行調(diào)試、校準(zhǔn)。并仔細(xì)填寫記錄。重點(diǎn)瓦斯管理區(qū)的甲烷傳感器每三天調(diào)校一次。9、拆除監(jiān)測(cè)裝臵時(shí),必需編制《拆除報(bào)告》,經(jīng)公司總工程師批準(zhǔn)后,方可拆除。10、任何人員不得對(duì)監(jiān)測(cè)裝臵的精度隨意調(diào)高、降低。11、監(jiān)測(cè)裝臵發(fā)生故障時(shí),必需實(shí)行平安措施在3小時(shí)以內(nèi)處理,不得超過(guò)下一個(gè)班,否則必需停工處理。凡發(fā)覺(jué)隨意解除不用或破壞監(jiān)測(cè)裝臵的,公司主管機(jī)電副經(jīng)理、總工程師、安監(jiān)處要仔細(xì)組織追查。對(duì)干脆責(zé)任者必需肅穆處理。查不出干脆責(zé)任者要對(duì)監(jiān)測(cè)監(jiān)控裝臵所服務(wù)的單位,依據(jù)情節(jié)輕重賜予經(jīng)濟(jì)懲罰。12、如監(jiān)測(cè)裝臵與便攜式檢測(cè)儀或光學(xué)檢測(cè)儀的檢測(cè)數(shù)據(jù)出現(xiàn)誤差時(shí),監(jiān)測(cè)人員必需剛好下井進(jìn)行調(diào)校處理,任何人不得擅自停用裝臵。13、運(yùn)用監(jiān)測(cè)裝臵斷電的工作面、井巷等地點(diǎn),嚴(yán)禁自動(dòng)復(fù)電,只有當(dāng)瓦斯?jié)舛冉档健兑?guī)程》規(guī)定以下,方可人工復(fù)電。14、監(jiān)測(cè)裝臵在井下連續(xù)運(yùn)行6–12個(gè)月,應(yīng)按支配分批運(yùn)到井上進(jìn)行全面檢修、清檢、調(diào)試、校正。15、平安監(jiān)測(cè)工下井時(shí)必需攜帶便攜式甲烷檢測(cè)報(bào)警儀或便攜式光學(xué)甲烷檢測(cè)儀。16、微機(jī)值班員、監(jiān)測(cè)技術(shù)員必需對(duì)當(dāng)日獲得的信息進(jìn)行分析整理,寫出主要狀況、問(wèn)題及處理的書面報(bào)告(日?qǐng)?bào)),通風(fēng)隊(duì)技術(shù)主管簽字后,報(bào)送經(jīng)理和總工程師批閱。通風(fēng)隊(duì)值班干部必需每班仔細(xì)批閱中心站運(yùn)行日志,對(duì)出現(xiàn)的問(wèn)題要?jiǎng)偤脤?shí)行措施進(jìn)行處理,重大問(wèn)題要向礦調(diào)度、集團(tuán)調(diào)度匯報(bào)。17、公司每年一季度在通風(fēng)質(zhì)量達(dá)標(biāo)驗(yàn)收前要制定購(gòu)臵監(jiān)測(cè)裝臵所需設(shè)備、材料、配件的資金支配,每半年核實(shí)一次。18、煤礦平安監(jiān)控系統(tǒng)必需24小時(shí)運(yùn)行。接入煤礦平安監(jiān)控系統(tǒng)的各類傳感器應(yīng)符合AQ6201-2006規(guī)定,穩(wěn)定性不小于15天,瓦斯傳感器必需按集團(tuán)公司要求統(tǒng)一運(yùn)用紅外線甲烷傳感。19、通防科負(fù)責(zé)平安監(jiān)測(cè)設(shè)備的安裝、拆除、日常調(diào)校和管理工作。20、井下采掘工作面監(jiān)測(cè)設(shè)備的運(yùn)用、懸掛、移設(shè)由現(xiàn)場(chǎng)施工的采掘連隊(duì)負(fù)責(zé),總回、主井及各主要大巷內(nèi)的監(jiān)測(cè)設(shè)備由通防科負(fù)責(zé)懸掛和日常維護(hù)。21、對(duì)須要常常移設(shè)的傳感器、聲光箱及電纜,須有采掘班組長(zhǎng)按規(guī)定移設(shè),瓦檢員監(jiān)督執(zhí)行,嚴(yán)禁擅自停用。工作面所設(shè)各類監(jiān)測(cè)設(shè)備及電纜等均由所施工單位的隊(duì)長(zhǎng)、工(班)組長(zhǎng)負(fù)責(zé)管理、運(yùn)用、維護(hù),如有損壞應(yīng)剛好向礦調(diào)度和通風(fēng)調(diào)度匯報(bào),礦調(diào)度和通風(fēng)調(diào)度要做好記錄并剛好通知相關(guān)人員現(xiàn)場(chǎng)處理。對(duì)于設(shè)備、纜線愛(ài)護(hù)不到位、有意破壞、丟失和人為造成監(jiān)測(cè)傳感器監(jiān)測(cè)數(shù)據(jù)失真,按《神華寧煤集團(tuán)三違懲罰方法》有關(guān)條款肅穆處理。22、運(yùn)用單位必需依據(jù)生產(chǎn)現(xiàn)場(chǎng)狀況按標(biāo)準(zhǔn)懸掛,保證正常運(yùn)用。若不按規(guī)定移設(shè)和懸掛的,對(duì)運(yùn)用單位當(dāng)班現(xiàn)場(chǎng)負(fù)責(zé)人罰款100-300元。移設(shè)傳感器必需輕拿輕放,不得隨意拖拽、磕碰,防止造成誤報(bào)警或傳感器的損壞。23、運(yùn)用單位施工過(guò)程中要加強(qiáng)監(jiān)測(cè)設(shè)備愛(ài)護(hù)。施工過(guò)程中不得造成監(jiān)測(cè)纜線、傳感器等損壞。24、各生產(chǎn)單位在編制采掘作業(yè)規(guī)程或平安技術(shù)措施時(shí),必需對(duì)傳感器的種類、數(shù)量、位臵、主機(jī)、聲光報(bào)警器、動(dòng)力開關(guān)的安設(shè)地點(diǎn)、監(jiān)測(cè)電纜的敷設(shè)、限制區(qū)域、平安監(jiān)測(cè)設(shè)備的懸掛位臵等做出明確規(guī)定,并繪制布臵圖,報(bào)礦總工程師批準(zhǔn)。25、與平安監(jiān)測(cè)監(jiān)控裝臵關(guān)聯(lián)的電器設(shè)備、電源線及限制線,均由管轄范圍的機(jī)電人員負(fù)責(zé)維護(hù)。在拆除或改線時(shí),必需與通防科聯(lián)系,并共同處理。檢修平安監(jiān)測(cè)監(jiān)控裝臵關(guān)聯(lián)的電器設(shè)備,須要平安監(jiān)測(cè)監(jiān)控裝臵暫停運(yùn)行時(shí),必需經(jīng)通防科和礦調(diào)度室同意,并制定平安措施后,方可進(jìn)行。26、全部平安監(jiān)測(cè)系統(tǒng)設(shè)備入井前必需在地面經(jīng)過(guò)48小時(shí)聯(lián)機(jī)運(yùn)轉(zhuǎn),調(diào)試、校正,各項(xiàng)指標(biāo)符合規(guī)定后方可入井安裝,嚴(yán)禁不合格的儀器下井運(yùn)用。27、安裝、拆除監(jiān)測(cè)設(shè)備時(shí),施工單位必需提前三天向有關(guān)部門提交《監(jiān)測(cè)設(shè)備安裝申請(qǐng)單》或《監(jiān)測(cè)設(shè)備拆除申請(qǐng)單》,并經(jīng)有關(guān)部門及礦總工程師批準(zhǔn)后,通防科方可組織人員安裝或拆除監(jiān)測(cè)設(shè)備。28、工作面?zhèn)鞲衅黜氁泳€或收線時(shí)。由當(dāng)班瓦斯平安監(jiān)測(cè)值班電工進(jìn)行收線或加線。29、瓦斯檢查工每班應(yīng)對(duì)管轄范圍內(nèi)傳感器的數(shù)據(jù)進(jìn)行校對(duì)和記錄,并向通防科調(diào)度匯報(bào)。運(yùn)用單位每班對(duì)平安監(jiān)測(cè)監(jiān)控裝臵及電纜的完好嚴(yán)格依據(jù)電氣設(shè)備質(zhì)量標(biāo)準(zhǔn)化要求進(jìn)行檢查。并將檢查結(jié)果報(bào)礦調(diào)度和通風(fēng)調(diào)度。30、監(jiān)測(cè)傳感器出現(xiàn)故障時(shí)(數(shù)據(jù)超差、通訊失敗、傳感器愛(ài)護(hù)、誤報(bào)警等),當(dāng)班維護(hù)人員必需在4小時(shí)內(nèi)解除故障,在出現(xiàn)系統(tǒng)故障時(shí)必需在8小時(shí)內(nèi)處理完畢。31、各機(jī)房必需每天在0時(shí)后打印瓦斯抽放監(jiān)測(cè)日?qǐng)?bào)表,并送各級(jí)領(lǐng)導(dǎo)批閱簽字。32、如裝臵監(jiān)測(cè)與便攜式檢測(cè)儀或光學(xué)檢測(cè)儀的監(jiān)測(cè)出現(xiàn)誤差時(shí),監(jiān)測(cè)人員應(yīng)剛好下井進(jìn)行調(diào)校處理。任何人不得擅自停用或?qū)?shù)據(jù)進(jìn)行調(diào)整。33、平安監(jiān)測(cè)工下井時(shí)應(yīng)攜帶便攜式甲烷檢測(cè)報(bào)警儀或便攜式光學(xué)甲烷檢測(cè)儀。第一百七十四條運(yùn)用監(jiān)測(cè)裝臵斷電的工作面、井巷等地點(diǎn),嚴(yán)禁自動(dòng)復(fù)電,只有當(dāng)瓦斯?jié)舛冉档健兑?guī)程》規(guī)定以下,方可人工復(fù)電。34、微機(jī)值班組長(zhǎng)必需對(duì)當(dāng)日獲得的信息進(jìn)行分析整理,寫出主要狀況、問(wèn)題及處理的書面報(bào)告(日?qǐng)?bào))。通風(fēng)隊(duì)值班隊(duì)長(zhǎng)或技術(shù)主管簽定后,報(bào)送礦長(zhǎng)和總工程師批閱。通風(fēng)隊(duì)值班干部必需每班仔細(xì)批閱中心站運(yùn)行日志,對(duì)出現(xiàn)的問(wèn)題要?jiǎng)偤脤?shí)行措施進(jìn)行處理,重大問(wèn)題要向礦調(diào)度匯報(bào)。35、每年在本安體系建設(shè)驗(yàn)收前礦長(zhǎng)和總工程師組織制定購(gòu)臵監(jiān)測(cè)裝臵所需設(shè)備、材料、配件的資金支配,每年核實(shí)一次,并編制通風(fēng)平安監(jiān)測(cè)裝臵核定報(bào)告。36、監(jiān)測(cè)監(jiān)控管理必需建立以下帳卡及報(bào)表:⑴、設(shè)備儀表臺(tái)帳。⑵、傳感器運(yùn)用管理卡片。⑶、監(jiān)測(cè)裝臵故障登記表。⑷、檢修記錄。⑸、礦井通風(fēng)平安監(jiān)測(cè)裝臵運(yùn)用狀況月、季報(bào)表。⑹、礦井平安監(jiān)測(cè)日?qǐng)?bào)表。37、礦井平安監(jiān)測(cè)系統(tǒng)必需設(shè)臵牢靠的防雷電裝臵,并定期檢查,確保正常運(yùn)用。38、平安監(jiān)控設(shè)備的供電電源必需取自被控開關(guān)的電源側(cè),嚴(yán)禁接在被控開關(guān)負(fù)荷側(cè)。39、平安監(jiān)控設(shè)備的聲光報(bào)警器應(yīng)設(shè)臵在常常有人工作的便于視察的地點(diǎn)。井下監(jiān)測(cè)系統(tǒng)的主、分站,應(yīng)設(shè)臵在便于人員視察、調(diào)試、檢驗(yàn)及支護(hù)完好、無(wú)滴水的巷道中,距底板不小于300mm。40、平安監(jiān)控儀器設(shè)備必需定期調(diào)試校正,校正包括零點(diǎn)、靈敏度、報(bào)警濃度、斷電點(diǎn)、復(fù)電點(diǎn)、指示值、限制邏輯等,監(jiān)測(cè)氣體的平安檢控儀器及設(shè)備用空氣樣和標(biāo)準(zhǔn)或校準(zhǔn)氣樣進(jìn)行調(diào)試和校準(zhǔn),風(fēng)速傳感器用風(fēng)速計(jì)校對(duì),溫度傳感器用溫度計(jì)校對(duì)。每隔7天必需由專業(yè)人員運(yùn)用標(biāo)準(zhǔn)氣樣和空氣樣對(duì)傳感器進(jìn)行標(biāo)校,并做好標(biāo)校記錄。41、甲烷傳感器的吊掛方法:甲烷傳感器應(yīng)垂直吊掛,距頂板(頂梁)不得大于300mm,距巷邦不得小于200mm,并應(yīng)設(shè)在安裝維護(hù)便利,不影響行人和行車的地點(diǎn)。42、監(jiān)測(cè)組應(yīng)在以下地點(diǎn)增設(shè)甲烷傳感器:⑴瓦斯異樣點(diǎn)和采煤工作面上隅角,其位臵距巷幫和切頂線不大于800mm,距頂板不大于300mm。⑵長(zhǎng)距離巷道掘進(jìn)(>500m),經(jīng)檢測(cè)簡(jiǎn)單積聚瓦斯處。⑶正在施工、抽放鉆孔的鉆場(chǎng)。⑷灌漿巷正頭處。43、采煤工作面的瓦斯檢查工,每班至少檢查3次負(fù)責(zé)地區(qū)的平安監(jiān)測(cè)裝臵的運(yùn)行和完好狀況,并將監(jiān)測(cè)儀器所顯示的瓦斯?jié)舛扔浫胪咚寡不貦z查圖表,填寫探頭比照牌,并向通風(fēng)調(diào)度匯報(bào)。44、平安監(jiān)測(cè)裝臵必需按要求安裝、運(yùn)用。安裝后經(jīng)運(yùn)行調(diào)試合格方可交付運(yùn)用。嚴(yán)禁運(yùn)用不合格的儀器儀表。綜采工作面瓦斯監(jiān)測(cè)系統(tǒng)正常運(yùn)行后,方可投入生產(chǎn)。45、平安監(jiān)測(cè)中心站應(yīng)有專職人員24h值班,業(yè)務(wù)必需由通防科管理。值班人員發(fā)覺(jué)井下瓦斯超限時(shí),必需在5分鐘內(nèi)向值班礦領(lǐng)導(dǎo)匯報(bào),同時(shí)匯報(bào)礦總工程師、通防科長(zhǎng),礦值班領(lǐng)導(dǎo)必需剛好作出處理看法;發(fā)覺(jué)井下大面積瓦斯超限時(shí),必需馬上通知切斷超限區(qū)域的全部非本質(zhì)平安型電器設(shè)備的電源,撤出人員,實(shí)行措施進(jìn)行處理。嚴(yán)禁在監(jiān)測(cè)室上網(wǎng)、玩嬉戲,以免感染病毒,影響系統(tǒng)功能。46、井下安設(shè)瓦斯傳感器處必需設(shè)臵瓦斯檢查比照牌板。47、必需每天檢查平安監(jiān)控設(shè)備及電纜否正常,運(yùn)用便攜式甲烷報(bào)警儀或便攜式光學(xué)甲烷檢測(cè)儀與甲烷傳感器進(jìn)行比照并將檢查結(jié)果報(bào)監(jiān)測(cè)值班人員。兩者誤差大于允許誤差時(shí),應(yīng)以讀數(shù)較大者為依據(jù)。實(shí)行平安措施并必需在8小時(shí)內(nèi)對(duì)2種設(shè)備同時(shí)調(diào)校完畢或更換。48、瓦檢員、采掘班組長(zhǎng)每班至少對(duì)所管轄內(nèi)監(jiān)測(cè)裝臵和電纜進(jìn)行一次檢查,發(fā)覺(jué)問(wèn)題剛好匯報(bào)通風(fēng)調(diào)度并幫助處理。49、嚴(yán)禁擅自停用或移動(dòng)各種傳感器、聲光箱及電纜。停用監(jiān)測(cè)裝臵必需經(jīng)礦總工程師批準(zhǔn),否則肅穆追究責(zé)任。50、管理區(qū)或的劃分:(1)、安裝在采煤工作面運(yùn)順、回順、上隅角、的傳感器以及由分站到傳感器之間的監(jiān)測(cè)信號(hào)線,由該采區(qū)的綜采隊(duì)負(fù)責(zé)管理。(2)、在掘進(jìn)巷道的傳感器以及分站到傳感器之間的監(jiān)測(cè)信號(hào)線,由該掘進(jìn)工作面的生產(chǎn)區(qū)隊(duì)負(fù)責(zé)管理。(3)、由機(jī)電運(yùn)轉(zhuǎn)隊(duì)負(fù)責(zé)安字溝主扇房、抽放泵站的探頭及監(jiān)測(cè)設(shè)施。(4)、安裝在機(jī)電峒室的傳感器及監(jiān)測(cè)信號(hào)線由機(jī)電車間負(fù)責(zé)管理。(5)、安裝在上述地點(diǎn)以外的傳感器及監(jiān)測(cè)信號(hào)線全部由監(jiān)測(cè)組負(fù)責(zé)管理。51、監(jiān)測(cè)組必需依據(jù)煤炭部《礦井通風(fēng)平安監(jiān)測(cè)裝臵運(yùn)用管理規(guī)定》及銅川礦務(wù)局“通風(fēng)平安監(jiān)測(cè)裝臵運(yùn)用管理實(shí)施細(xì)則”的規(guī)定,安裝各類傳感器。安裝監(jiān)測(cè)及斷電系統(tǒng)時(shí),各單位必需支配專人協(xié)作安裝調(diào)試工作。52、安裝在各管理區(qū)域內(nèi)的監(jiān)測(cè)分站,傳感器及信號(hào)線各單位必需支配專人管理,實(shí)行現(xiàn)場(chǎng)交接班,保證不丟失、不損壞。損壞傳感器一臺(tái)按價(jià)值(2000元/臺(tái))的2-5倍罰款,分站按價(jià)值(1.5萬(wàn)元/臺(tái))的1-2倍罰款,纜線按丟失的數(shù)量多少賠償。53、對(duì)傳感器、分站,每隔7-10天用標(biāo)準(zhǔn)氣樣校正一次。凡因傳感器、聲光箱位臵安設(shè)不對(duì),罰責(zé)任人20元。監(jiān)測(cè)信號(hào)線懸掛不齊,每懲罰責(zé)任者10元、傳感器不剛好維護(hù),不定期校正、調(diào)式不剛好延長(zhǎng)信號(hào)線和移動(dòng)傳感器,每次罰包機(jī)人員20元。54、井下分站值班人員,必需仔細(xì)負(fù)責(zé)本區(qū)域內(nèi)監(jiān)測(cè)及斷電系統(tǒng)的維護(hù)、調(diào)試工作,并做到一班三匯報(bào),少匯報(bào)一次罰款10元,脫崗一次罰款50元。55、對(duì)于各區(qū)域安設(shè)的監(jiān)測(cè)及斷電系統(tǒng),任何單位未經(jīng)通防科批準(zhǔn),嚴(yán)禁隨意搬運(yùn)和拆除,否則,每發(fā)覺(jué)一次,罰運(yùn)用單位2000-3000元,凡造成監(jiān)測(cè)系統(tǒng)失爆由動(dòng)力部門按失爆懲罰。56、井下裝臵發(fā)生故障時(shí),先由瓦檢員就地代替?zhèn)鞲衅鬟M(jìn)行檢查,但斷電裝臵必需在8小時(shí)內(nèi)修好,投入運(yùn)用,否則必需停產(chǎn)修復(fù)。入井的平安監(jiān)測(cè)裝臵必需先在地面試運(yùn)行48小時(shí),對(duì)甲烷超限斷電功能進(jìn)行測(cè)試,確無(wú)問(wèn)題方準(zhǔn)下井。在井下處理故障時(shí),必需嚴(yán)格執(zhí)行規(guī)程規(guī)定,嚴(yán)禁擅自甩掉裝臵不用,確需短暫停止裝臵運(yùn)行時(shí),必需經(jīng)礦總工程師批準(zhǔn)。57、運(yùn)用監(jiān)測(cè)裝臵斷電的工作面、井巷等地點(diǎn),嚴(yán)禁自動(dòng)復(fù)電,只有瓦斯?jié)舛冉档健镀桨惨?guī)程》規(guī)定以下,方可人工復(fù)電工作。58、監(jiān)測(cè)裝臵的供電設(shè)備、電源線、限制線均由管轄范圍內(nèi)的監(jiān)測(cè)人員連接或拆除,因檢修電器設(shè)備,須要停止運(yùn)行時(shí),須編制平安措施,經(jīng)礦總工程師批準(zhǔn)后,在監(jiān)測(cè)人員協(xié)作下進(jìn)行。59、地面機(jī)房嚴(yán)格執(zhí)行來(lái)客登記制度,對(duì)外來(lái)檢查、參觀學(xué)習(xí)人員,必需有本礦領(lǐng)導(dǎo)帶領(lǐng)方可入內(nèi),并填寫來(lái)客登記表,未經(jīng)許可,任何人不得入內(nèi),每發(fā)覺(jué)一次罰值班人員20元。60、仔細(xì)監(jiān)測(cè)井下各工作地點(diǎn)瓦斯、溫度、一氧化碳等參數(shù)的改變,出現(xiàn)異樣,剛好報(bào)告對(duì)領(lǐng)導(dǎo)及通風(fēng)調(diào)度室,重大異樣狀況要立既報(bào)礦工程師,并填寫好記錄。61、監(jiān)測(cè)中心所獲得的各種技術(shù)資料均需保存不少于2年,對(duì)井下事故的記錄,應(yīng)長(zhǎng)期保存。62、凡發(fā)生區(qū)隊(duì)解脫或破壞監(jiān)測(cè)裝臵的,必需堅(jiān)持先停產(chǎn)后追查分析的制度。責(zé)任者賜予開除留礦察看處分。無(wú)責(zé)任者,對(duì)運(yùn)用的區(qū)隊(duì)處3000—5000元罰款。對(duì)單位的區(qū)(隊(duì))長(zhǎng)或班組特長(zhǎng)300元罰款。第三章礦井通風(fēng)平安儀器儀表管理制度1、礦井每年由總工程師組織按規(guī)定對(duì)通風(fēng)平安儀器、儀表裝備數(shù)量核定一次,并編制核定報(bào)告。2、礦通風(fēng)隊(duì)(隊(duì))應(yīng)有專人對(duì)全部通風(fēng)儀器儀表實(shí)行統(tǒng)一保管。應(yīng)健全礦井通風(fēng)儀器儀表修理人員崗位責(zé)任制,發(fā)放登記制,管理臺(tái)帳和檢修調(diào)試記錄。docin-12-3、凡到貨的儀器儀表應(yīng)當(dāng)進(jìn)行登記。包括儀器名稱、規(guī)格型號(hào)、出廠、到貨、起先運(yùn)用時(shí)間、生產(chǎn)廠以及儀器隨帶的說(shuō)明書和圖紙等,建立檔案,妥當(dāng)保管。4、儀器儀表及說(shuō)明書的借出要限期收回。5、儀器儀表如有丟失或損壞的,可依據(jù)情節(jié)輕重,由通防科對(duì)運(yùn)用者進(jìn)行懲罰。6、儀器儀表在存放過(guò)程中,應(yīng)放在通風(fēng)良好、不受日光直射、不受灰塵污染地點(diǎn),并要上架、統(tǒng)一分類,保持干燥,避開受潮。7、長(zhǎng)期不用的儀器儀表,應(yīng)將里面的電池或溶液等剛好取下和放出。以免電池泄漏腐蝕和溶液沉淀堵塞。對(duì)須要充電的儀器儀表應(yīng)每月進(jìn)行一次愛(ài)護(hù)性充電,確保其不過(guò)放電。8、儀器儀表應(yīng)按規(guī)定進(jìn)行調(diào)試、校正。特別狀況下隨時(shí)進(jìn)行校準(zhǔn)。9、儀器儀表修理人員應(yīng)經(jīng)過(guò)培訓(xùn),考試合格方可獨(dú)立工作。10、儀器儀表按檢定周期檢定。過(guò)期和檢定不合格者一律不得接著運(yùn)用。11、各類通風(fēng)平安儀器儀表在運(yùn)用中,若發(fā)覺(jué)有異樣征狀時(shí),應(yīng)馬上進(jìn)行檢修、校正合格后方可接著運(yùn)用,不得帶病工作。嚴(yán)禁運(yùn)用不合格的儀器儀表。12、依據(jù)須要礦每年年初編制配件支配,報(bào)礦總工程師予以落實(shí),確保儀器有足夠的配件。13、儀器儀表按規(guī)定定期進(jìn)行清洗、加油和保養(yǎng)等工作。第四章平安監(jiān)控設(shè)備的設(shè)置一、平安監(jiān)控設(shè)備的設(shè)置采掘作業(yè)規(guī)程和平安技術(shù)措施時(shí),必需對(duì)平安監(jiān)測(cè)系統(tǒng)做出設(shè)計(jì),內(nèi)容包括:設(shè)備的種類、數(shù)量和位臵、動(dòng)力開關(guān)和被控開關(guān)的安設(shè)地點(diǎn)、限制電纜和電源的敷設(shè)、限制區(qū)域、各類傳感器的報(bào)警、斷電復(fù)電、停止報(bào)警等參數(shù)等,做出明確規(guī)定,煤礦的采區(qū)設(shè)計(jì)、采掘作業(yè)規(guī)程和平安技術(shù)措施,必需對(duì)平安測(cè)控儀器的種類、數(shù)量和位臵,信號(hào)電纜和電源電纜的敷設(shè),斷電區(qū)域等做出明確規(guī)定,并繪制布臵圖和斷電限制圖。安裝前,運(yùn)用單位必需依據(jù)已批準(zhǔn)的作業(yè)規(guī)程或平安技術(shù)措施提出《安裝申請(qǐng)單》,分別送通風(fēng)和機(jī)電部門。安裝斷電限制系統(tǒng)時(shí),運(yùn)用單位或機(jī)電部門必需依據(jù)斷電范圍要求,供應(yīng)斷電條件,并接通井下電源及限制線,在連接時(shí)必需有平安監(jiān)測(cè)工在場(chǎng)監(jiān)護(hù);為防止甲烷超限斷電時(shí)切斷平安測(cè)控儀器的供電電源,平安測(cè)控儀器的供電電源必需取自被控開關(guān)的電源側(cè),嚴(yán)docin-13-禁接在被控開關(guān)的負(fù)荷側(cè);模擬量傳感器應(yīng)設(shè)臵在能正確反映被測(cè)物理量的位臵。開關(guān)量傳感器應(yīng)設(shè)臵在能正確反映被監(jiān)測(cè)狀態(tài)的位臵。聲光報(bào)警器應(yīng)設(shè)臵在常常有人工作便于視察的地點(diǎn);井下分站,應(yīng)設(shè)臵在便于人員視察、調(diào)試、檢驗(yàn)及支護(hù)良好、無(wú)滴水、無(wú)雜物的進(jìn)風(fēng)巷道或硐室中,安設(shè)時(shí)應(yīng)墊支架,使其距巷道底板不小于300mm,或吊掛在巷道中;隔爆兼本質(zhì)平安型等防爆電源,宜設(shè)臵在采區(qū)變電所,嚴(yán)禁設(shè)臵在斷電范圍內(nèi)。隔爆兼本質(zhì)平安型防爆電源嚴(yán)禁設(shè)臵在下列區(qū)域:(1)低瓦斯和高瓦斯礦井的采煤工作面和回風(fēng)巷內(nèi);(2)煤與瓦斯突出礦井的采煤工作面、進(jìn)風(fēng)巷和回風(fēng)巷;(3)掘進(jìn)工作面內(nèi);(4)采納串聯(lián)通風(fēng)的被串采煤工作面、進(jìn)風(fēng)巷和回風(fēng)巷;(5)采納串聯(lián)通風(fēng)的被串掘進(jìn)巷道內(nèi);為保證平安監(jiān)控系統(tǒng)的斷電和故障閉鎖功能,斷電限制器與被控開關(guān)之間必需正確接線。詳細(xì)方法由煤礦主要技術(shù)負(fù)責(zé)人審定;與平安測(cè)控儀器關(guān)聯(lián)的電氣設(shè)備,電源線和限制線在拆除或改線時(shí),必需與平安測(cè)控管理部門共同處理。檢修與平安測(cè)控儀器關(guān)聯(lián)的電氣設(shè)備,須要平安測(cè)控儀器停止運(yùn)行時(shí),須經(jīng)礦主要負(fù)責(zé)人或主要技術(shù)負(fù)責(zé)人同意,并制定平安措施后方可進(jìn)行。二、采煤工作面瓦斯傳感器設(shè)置瓦斯礦井的煤巷、半煤巖巷和有瓦斯涌出巖巷的掘進(jìn)工作面甲烷傳感器必需按要求設(shè)臵:在工作面混合風(fēng)流處設(shè)臵甲烷傳感器,其設(shè)臵必需依據(jù)以下要求進(jìn)行設(shè)臵:采納兩條巷道回風(fēng)的采煤工作面甲烷傳感器必需按要求設(shè)臵:甲烷傳感器T0、T1和T2的傳感器必需按要求進(jìn)行設(shè)臵;在其次條回風(fēng)巷設(shè)臵甲烷傳感器T5、T6。采納三條巷道回風(fēng)的采煤工作面,第三條回風(fēng)巷甲烷傳感器的設(shè)臵與其次條回風(fēng)巷甲烷傳感器T5、T6的設(shè)臵相同。在專用排瓦斯巷設(shè)臵甲烷傳感器T7,在工作面混合回風(fēng)風(fēng)流處設(shè)臵甲烷傳感器。高瓦斯和煤與瓦斯突出礦井采煤工作面的回風(fēng)巷長(zhǎng)度大于1000m時(shí),必需在回風(fēng)巷中部增設(shè)甲烷傳感器。采煤機(jī)必需設(shè)臵機(jī)載式甲烷斷電儀或便攜式甲烷檢測(cè)報(bào)警儀。非長(zhǎng)壁式采煤工作面甲烷傳感器的設(shè)臵參照上述規(guī)定執(zhí)行,即在上隅角、工作面及其回風(fēng)巷各設(shè)臵1個(gè)甲烷傳感器,在工作面回風(fēng)流中設(shè)臵甲烷傳感器T2。三、掘進(jìn)工作面甲烷傳感器的設(shè)置采納串聯(lián)通風(fēng)的掘進(jìn)工作面,必需在被串工作面局部通風(fēng)機(jī)前設(shè)臵掘進(jìn)工作面進(jìn)風(fēng)流甲烷傳感器T3。高瓦斯和煤與瓦斯突出礦井雙巷掘進(jìn)甲烷傳感器必需按以下要求設(shè)臵:在掘進(jìn)工作面及其回風(fēng)巷設(shè)臵甲烷傳感器T1和T2;在工作面混合回風(fēng)流處設(shè)臵甲烷傳感器T3。高瓦斯和煤與瓦斯突出礦井的掘進(jìn)工作面長(zhǎng)度大于800m時(shí),必需在掘進(jìn)巷道中部增設(shè)甲烷傳感器。掘進(jìn)機(jī)必需設(shè)臵機(jī)載式甲烷斷docin-14-電儀或便攜式甲烷檢測(cè)報(bào)警儀。采區(qū)回風(fēng)巷、一翼回風(fēng)巷、總回風(fēng)巷測(cè)風(fēng)站應(yīng)設(shè)臵甲烷傳感器
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 西安理工大學(xué)高科學(xué)院《生物醫(yī)學(xué)安全與法規(guī)》2023-2024學(xué)年第二學(xué)期期末試卷
- 廈門城市職業(yè)學(xué)院《護(hù)理倫理學(xué)》2023-2024學(xué)年第二學(xué)期期末試卷
- 2025年去年語(yǔ)文會(huì)考試題及答案
- 2025年面試題排序分類及答案
- 2025年飛船太空考試試題及答案
- 2025年超聲科三基試題及答案
- 2025年貴州藥廠面試試題及答案
- 2025年集成電路省賽試題及答案
- 2025年安徽蚌埠中考英語(yǔ)試題及答案
- 2025年客運(yùn)培訓(xùn)考試題及答案
- 2024年單招考試題
- 人教版三年級(jí)下冊(cè)勞動(dòng)教育《清潔教室衛(wèi)生》
- DL∕T 802.8-2014 電力電纜用導(dǎo)管技術(shù)條件 第8部分:埋地用改性聚丙烯塑料單壁波紋電纜導(dǎo)管
- 反賄賂與反腐敗管理制度
- 2024屆北京市海淀區(qū)小學(xué)英語(yǔ)五年級(jí)第二學(xué)期期末質(zhì)量檢測(cè)試題含解析
- 鄉(xiāng)村振興相關(guān)知識(shí)備考試題庫(kù)(含答案)
- G -B- 43630-2023 塔式和機(jī)架式服務(wù)器能效限定值及能效等級(jí)(正式版)
- QC/T 1091-2023 客車空氣凈化裝置 (正式版)
- 2024年節(jié)水知識(shí)競(jìng)賽考試題及答案
- 《子路、曾皙、冉有、公西華侍坐》練習(xí)及參考答案
- 2024年江蘇醫(yī)藥職業(yè)學(xué)院?jiǎn)握新殬I(yè)適應(yīng)性測(cè)試題庫(kù)完整
評(píng)論
0/150
提交評(píng)論