版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
1、Power System Dynamics- Postgraduate Course of Tsinghua Univ. Graduate School at ShenzhenNI YixinAssociate ProfessorDept. of EEE, HKUIntroduction0.1 Requirements of modern power systems (P. S. )0.2 Recent trends of P. S.0.3 Complexity of modern P. S.0.4 Definitions of different types of P. S. stabili
2、ty0.5 Computer-aid P. S. stability analysis0.6 Contents of our courseIntroduction (1)0.1 Requirements of modern power systems (P. S. )Satisfying load demands (as a power source)Good quality: voltage magnitude, symmetric three phase voltages, low harmonics, standard frequency etc. (as a 3-phase ac vo
3、ltage source)Economic operationSecure and reliable operation with flexible controllability Loss of any one element will not cause any operation limit violations (voltage, current, power, frequency, etc. ) and all demands are still satisfied.For a set of specific large disturbances, the system will k
4、eep stable after disturbances.Good energy management systems (EMS)Introduction (2)0.2 Recent trends of P. S.Systems interconnection: to obtain more benefits. It may lead to new stability issues ( e.g. low-frequency power oscillation on the tie lines; SSR caused by series-compensated lines etc. ). Sy
5、stems are often heavily loaded and very stressed. System stability under disturbances is of great concern. New technology applications in power systems. (e.g. computer/ modern control theory/ optimization theory/ IT/ AI tech. etc. ) Power electronics applications: provides flexible controller in pow
6、er systems. ( e. g. HVDC transmission systems, STATCOM, UPFC, TCSC, etc.) Introduction (3)0.3 Complexity of modern P. S.Large scale, Hierarchical and distributed structure, Non-storable electric energy, Fluctuate and random loads, Highly nonlinear dynamic behavior, Unforeseen emergencies, Fast trans
7、ients which may lead to system collapse in seconds or minutes, Complicated control and their coordination requests. - Modern P. S. is much more complicated than ever and in the meantime it plays a significant role in modern society. Introduction (4)Some viewpoints of Dr. Kundur (author of the ref. b
8、ook ):- The complexity of power systems is continually increasing because of the growth in interconnections and use of new technologies. At the same time, financial and regulatory constrains have forced utilities to operate the systems nearly at stability limits.- Of all the complex phenomena on pow
9、er systems, power system stability is the most intricate to understand and challenging to analyze. Electric power systems of the 21 century will present an even more formidable challenge as they are forced to operate closer to their stability limit. Introduction (5)0.4 Definitions of different types
10、 of P. S. stabilityP. S. stability: the property of a P. S. that enable it to remain in a state of operating equilibrium under normal operating conditions and to return to an acceptable state of equilibrium after being disturbed. Classification of stabilityBased on size of disturbance: large disturb
11、ance stability ( transient stability, IEEE): nonlinear system models small disturbance/signal stability ( steady-state stability, IEEE): linearized system models The time span considered:transient stability: 0 to 10 secondsmid-term stability: 10 seconds to a few minuteslong-term stability(dynamics):
12、 a few minutes to 1 hour Introduction (6)0.4 Definitions of different types of P. S. stability (cont.)Classification of stability (cont.)Based on physical nature of stability:Synchronous operation (or angle) stability: insufficient synchronizing torque - non-oscillatory instabilityinsufficient dampi
13、ng torque - oscillatory instabilityVoltage stability:insufficient reactive power and voltage controllabilitySubsynchronous oscillation (SSO) stabilityinsufficient damping torque in SSOIntroduction (7)0.5 Computer-aid P. S. stability analysisIntroduction (8) 0.6 Contents of the courseIntroductionPart
14、 I: Power system element models 1. Synchronous machine models 2. Excitation system models 3. Prime mover and speed governor models 4. Load models 5. Transmission line and transformer models Part II: Power system dynamics: theory and analysis 6. Transient stability and time simulation 7. Steady-state
15、 stability and eigenvalue analysis 8. Low-frequency oscillation and control 9. *Voltage stability 10. *Subsynchronous oscillation 11. Improvement of system stability SummaryPart I Power system element modelsChapter 1 Synchronous machine models(a)Chapter 1 Synchronous machine (S. M.) models1.1 Ideal
16、S. M. and its model in abc coordinates1.1.1 Ideal S. M. definitionNote: * S. M. is a rotating magnetic element with complex dynamic behavior. It is the heart of P. S. It * It provides active and reactive power to loads and has strong power, frequency and voltage regulation/control capability . * To
17、study S. M., mathematic models are developed for S. M. * Special assumptions are made to simplify the modeling.Chapter 1 Synchronous machine (S. M.) models1.1.1 Ideal S. M. definition (cont.):Assumptions for ideal S. M.Machine magnetic permeability (m) is a constant with magnetic saturation neglecte
18、d. Eddy current, hysteresis, and skin effects are neglected, so the machine is linear.Symmetric rotor structure in direct (d) and quadratic (q) axes. Symmetric stator winding structure: the three stator windings are 120 (electric) degrees apart in space with same structure. The stator and rotor have
19、 smooth surface with tooth and slot effects neglected. All windings generate sinusoidal distributed magnetic field.Chapter 1 Synchronous machine (S. M.) models1.1.2 Voltage equations in abc coordinatesPositive direction setting:dq and abc axes, speed directionAngle definition: Y directions for abcfD
20、Q windings i directions for abcfDQ u directions for abcfDQ (uD=uQ=0):(leading ahead )120 ,240240 ,120abaacaadaChapter 1 Synchronous machine (S. M.) models1.1.2 Voltage equations in abc coordinates (cont.)Voltage equations for abc windings:where p= d / dt, t in sec. rabc: stator winding resistance, i
21、n W. iabc : stator winding current, in A. uabc: stator winding phase voltage, in V. yabc: stator winding flux linkage, in Wb.Note: * pyabc: generate emf in abc windings * uabciabc: in generator conventional direction. * iabc yabc: positive iabc generates negative yabc respectivelyaaa abbb bccc cupr
22、iupr iupriChapter 1 Synchronous machine (S. M.) models1.1.2 Voltage equations in abc coordinates (cont.)Voltage equations for fDQ windings:rfDQ: rotor winding resistance, in W. f: field winding, D: damping winding in d-axis, Q: damping winding in q-axis.ifDG, ufDG, yfDG: rotor winding currents, volt
23、ages and flux linkages in A, V, Wb.Note: * uD=uQ=0 * ufDQifDQ: in load convention * ifDG yfDG: positive ifDG generates positive yfDG respectively * q-axis leads d-axis by 90 (electr.) deg. 00ffffDDD DQQQ Qupr iupr iupr iChapter 1 Synchronous machine (S. M.) models1.1.2 Voltage equations in abc coord
24、inates (cont.)Voltage equations in matrix format:where before iabc is caused by generator convention of stator windings.TTTT(,)(,)diag( ,)(,)abcfDQabcfDQaaafDQabcfDQpu u u uuu r r r r rriii iii iuriurChapter 1 Synchronous machine (S. M.) models1.1.3 Flux linkage equations in abc coordinatesaaaabacaf
25、aDaQabbabbbcbfbDbQbccacbcccfcDcQcffafbfcfffDfQfDDaDbDcDfDDDQDQQaQbQcQfQDQQQLLLLLLiLLLLLLiLLLLLLiLLLLLLiLLLLLLiLLLLLLi 11 3 312 3 3(6 1)(6 6) (6 1)21 3 322 3 3 or =;abcabcfDQfDQLLiLiiLLChapter 1 Synchronous machine (S. M.) models1.1.3 Flux linkage equations in abc coordinates (cont.)In Flux linkage e
26、qn.: Lij ( i, j = a, b, c, f, D, Q ): self and mutual inductances, L11 : stator winding self and mutual inductance, L22 : rotor winding self and mutual inductances, L12 , L21 : mutual inductances among stator and rotor windings , y, i : same definition as voltage eqn.Note: * Positive iabc generates
27、negative yabc respectively. * The negative signs of iabc make Laa, Lbb, Lcc 0.Chapter 1 Synchronous machine (S. M.) models1.1.3 Flux linkage equations in abc coordinates (cont.)Stator winding self/mutual inductance (L11)Stator winding self inductance (Laa, Lbb, Lcc) Laa: reach max d-a aligning (when
28、 qa=0, 180) reach min d-a perpendicular (when qa=90, 270) Laa qa: sin-curve, with period of 180 (LsLt0, for round rotor: Lt=0) (See appendix 1 of the text book for derivation)0 ( , ,0)aaabcfDQaLi i iiiicos2cos2cos2cos2(120 )cos2cos2(120 )aaStaStbbStbStccStcStLLLLLLLLLLLLLLLChapter 1 Synchronous mach
29、ine (S. M.) models1.1.3 Flux linkage equations in abc coordinates (cont.)Stator winding self/mutual inductance (L11)Stator winding mutual inductance Lab: reach max |.| when qa= -30, 150 reach min |.| when qa= 60, 240 Laa qa: sin-curve, with period of 180 (MsLt0, for round rotor: Lt=0)(See appendix 1
30、 of the text book for derivation), , ,0 (0);0 (0)ababa cfD Qbaabb cfD QbaLiLLiii= cos2(30 )(cos2(30 )= (cos2(90 )= (cos2(150 )abbastastbccbstcaacstLLMLMLLLMLLLML Chapter 1 Synchronous machine (S. M.) models1.1.3 Flux linkage equations in abc coordinates (cont.)Rotor winding self/mutual inductance (L
31、22)Rotor winding self inductance (constant: why?)Lff = Lf = const. 0LDD = LD = const. 0LQQ = LQ = const. 0Rotor winding mutual inductance LfQ = LfQ = 0, LDQ = LQD = 0 LfD = LDf = MR = const. 0Chapter 1 Synchronous machine (S. M.) models1.1.3 Flux linkage equations in abc coordinates (cont.)Stator an
32、d rotor winding mutual inductance (L12; L21 )abcf: (Mf=const.0, period: 360, max. when d-abc align)abcD: similar to abcf, MfMD0abcQ:(MQ=const.0, period: 360, max. when q-abc align)coscoscos(120 )cos(120 )affafafbffbfcffcfLLMMLLMLLMcos(90 )sinsin(120 )sin(120 )aQQaQaQbQQbQcQQcQLLMMLLMLLM Chapter 1 Sy
33、nchronous machine (S. M.) models1.1.3 Flux linkage equations in abc coordinates (summary)Time varying L-matrix : related to rotor position L11 (abcabc): 180 period; L12, L21(abcfDG): 360 period.Non-sparse L-matrix: most mutual inductances 0L-matrix: non-user friendly, lead to abc dq0 coordinates!000
34、0aaaabacafaDaQabbabbbcbfbDbQbccacbcccfcDcQcffafbfcfRfDDaDbDcRDDQQaQbQcQQLLLLLLiLLLLLLiLLLLLLiLLLLMiLLLMLiLLLLi Chapter 1 Synchronous machine (S. M.) models1.1.4 Generator power, torque and motion eqns.Instantaneous output power eqn. (Pe in W)Electromagnetic torque eqn. (Te in N-m, q in rad.)ccbbaaei
35、uiuiuPT T11()()()230111 1013110PePabcbcacabPabcabcdLTpiipiiiiiidpi (6 1): number of pole pairs, : (-, )PTTTabcfDQpiiiChapter 1 Synchronous machine (S. M.) models1.1.4 Generator power, torque and motion eqns. (cont.)Rotor motion eqns.According to Newtons law, we have: where Tm: input mechanical torqu
36、e of generator (in N-m) Te: output electromagnetic torque (in N-m) wm/qm: rotor mechanical speed/angle (in rad/s, rad.) we/qe: rotor electrical speed/angle (in rad/s, rad.), J: rotor moment of inertia (also called rotational inertia) J= Kg-m2 In the manufacturers handbook, J is given by GD2, in ton-m2. GD2 (ton-m2) 103/4 J (Kg-m2). dmmemmJTTdtddt/;/mePPmePPpppp2iiimrChapter 1 Synchronous
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 地皮訂金合同范例
- 企業(yè)商品訂購(gòu)供貨合同范例
- 購(gòu)買廠區(qū)護(hù)欄合同范例
- 商品代購(gòu)合同范例
- 機(jī)器預(yù)付合同范例
- 搬運(yùn)責(zé)任合同范例
- 最高額融資合同范例
- 警醫(yī)合作合同范例
- 勞務(wù)分包招投標(biāo)合同范例
- 2024年度藝術(shù)品收藏買賣合同樣本3篇
- 肛腸科常見(jiàn)疾病中醫(yī)診療規(guī)范診療指南2023版
- 水環(huán)境綜合治理服務(wù)方案(技術(shù)標(biāo))
- 2023《機(jī)械制造基礎(chǔ)》機(jī)考真題庫(kù)附答案
- 銀屑病教學(xué)查房課件
- 基于Java技術(shù)的酒店管理系統(tǒng)設(shè)計(jì)
- 全國(guó)職業(yè)院校技能大賽中職組法律實(shí)務(wù)比賽試題附答案
- 滑坡監(jiān)測(cè)方案
- 人工智能引論智慧樹(shù)知到課后章節(jié)答案2023年下浙江大學(xué)
- 歌曲演唱 萬(wàn)疆
- 消防工程竣工驗(yàn)收自評(píng)報(bào)告【精】
- 影像科與臨床科室定期溝通制度
評(píng)論
0/150
提交評(píng)論