




已閱讀5頁(yè),還剩7頁(yè)未讀, 繼續(xù)免費(fèi)閱讀
版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
ALU GSM網(wǎng)絡(luò)搬遷功率映射總結(jié)文檔密級(jí) 機(jī)密C國(guó)M項(xiàng)目ALU GSM網(wǎng)絡(luò)搬遷功率映射總結(jié)2010-6-20Document HistoryVersionDateEdited byModifications1.02010-6-20譚志偉Content1.項(xiàng)目背景信息42.ALU基站TOC分析42.1客戶提供的ALU基站功率信息分析42.2ALU基站TOC實(shí)測(cè)結(jié)果52.3ALU基站1TRX/2TRX TOC實(shí)測(cè)結(jié)果遠(yuǎn)低于客戶給的TOC原因分析53.功率匹配結(jié)果64.搬遷前后實(shí)際的覆蓋效果對(duì)比64.1 Rx_Lev Distribution before Swap74.2 Rx_Lev Distribution after Swap85.附錄:Alcatel基站功率配置和合路雙工器單元ANC81. 項(xiàng)目背景信息C國(guó)M項(xiàng)目,采用我司GBSS8.1全網(wǎng)搬遷Alcatel B9 MR4 eddition5 GSM設(shè)備。搬遷前后ALU和我司基站設(shè)備信息如下:n ALU: MBO1, MBO2, MBI5, 45W & 60W兩種射頻TRE模塊,全部采用ANC2雙工器;n Huawei:BTS3900(A), 射頻模塊配置為MRFU V1 和 MRFU V2??蛻艚o出原網(wǎng)TOC如下表,由于搬遷后大量基站從1-2TRX擴(kuò)容到3-4TRX,將有大量基站和小區(qū)搬遷后功率明顯下降,將嚴(yán)重影響網(wǎng)絡(luò)覆蓋指標(biāo),對(duì)KPI驗(yàn)收帶來(lái)極大風(fēng)險(xiǎn)。覆蓋下降涉及到的基站和小區(qū)統(tǒng)計(jì)結(jié)果如下: 覆蓋下降10%: 204基站/383小區(qū),分別占比45%和30%; 覆蓋下降5%:405基站/1022小區(qū),分別占比89%和79%;Table 1-1 ALU和Huawei基站TOC對(duì)比# TRXAlcatelHuawei MRFUNormal PowerHigh PowerETSI V1ETSI V2HPA(W)TOC(dBm)HPA(W)TOC(dBm)TOC(W)TOC(dBm)TOC(W)TOC(dBm)1TRX4545.736046.983144.914046.02 2TRX4545.736046.983144.914046.02 3TRX4542.336043.582043.982744.31 4TRX4542.336043.581643.012043.01 5TRX-1240.79 6TRX-1040.00 2. ALU基站TOC分析2.1 客戶提供的ALU基站功率信息分析客戶提供的ALU基站功率信息如表Table1-1所示,TOC計(jì)算結(jié)果客戶解釋如下:n 對(duì)于1 TRX 和2TRX,各TRX分路發(fā)射,ANC工作于Non-Combined模式(參見附錄),沒有合路,考慮0.8dB線纜接頭損耗,如下左圖所示;n 對(duì)于3 TRX 和4TRX,2路TRX合路發(fā)射,ANC工作于Combined模式(參見附錄),考慮約3.5dB的合路損耗和0.8dB線纜接頭損耗,如下右圖所示;據(jù)此計(jì)算出來(lái)的TOC確實(shí)如客戶給的結(jié)果一致(見Table1-1)。2.2 ALU基站TOC實(shí)測(cè)結(jié)果根據(jù)現(xiàn)場(chǎng)測(cè)試和勘測(cè)結(jié)果:n 1TRX/2TRX Alcatel Normal Power配置下, 最大TOC只有不到20W(42.24dBm),比客戶給的TOC低約3.5dBn 1TRX/2TRX Alcatel High Power配置下, 最大TOC只有不到25W(43.87), 比客戶給的TOC低約3.1dBn 3TRX/4TRX, 實(shí)測(cè)TOC與客戶給的TOC基本一致.Table2-1 Alcatel TOC測(cè)試結(jié)果SiteNameSector ID# TRXSite Type TRX Power Config(W) TOC Provided by 客戶(dBm) TOC Test AVG (dBm) TOC Test MAX (dBm)TOC Test MAX (W) Site_A11MBI56046.9843.743.8724.4 Site_A22MBI56046.9843.6143.7823.9 Site_B12MBI54545.7340.2242.2416.7 Site_B34MBI54542.3341.2141.7214.9 Site_C22MBO24546.9838.5640.4711.1 Site_C33MBO24542.3338.5942.0816.1 2.3 ALU基站1TRX/2TRX TOC實(shí)測(cè)結(jié)果遠(yuǎn)低于客戶給的TOC原因分析如下圖Figure2-1所示是現(xiàn)場(chǎng)勘測(cè)結(jié)果,全部基站1TRX/2TRX扇區(qū)ANC全部采用橋連Combined模式(參見附錄),TOC比Non-Combined模式低約3.5dB。(客戶可能是為了方便今后擴(kuò)TRX, 1TRX/2TRX全部默認(rèn)安裝了橋連線,ANC全部工作在Combined模式下)Figure2-1 勘測(cè)站點(diǎn)ANC配置圖橋連線。1TRX/2TRX 均采用了橋連,即Combined模式S222S223S111S2343. 功率匹配結(jié)果根據(jù)以上ALU基站TOC分析,現(xiàn)場(chǎng)確定功率匹配結(jié)果如下:n Alcatel橋連Combined模式下,采用MRFU V1/V2版本功率均能匹配,V1版本MRFU建議開啟功率共享;n 原網(wǎng)大部分站點(diǎn)為Normal Power配置,雖然有大量站點(diǎn)從1-2TRX擴(kuò)容到3-4TRX,但根據(jù)功率映射結(jié)果,在搬遷后我司設(shè)備仍有1-2dB增益,覆蓋性能將提升;# TRXAlcatel-CombinedHW MRFU ETSI V1 HW MRFU ETSI V2Normal PowerHigh PowerWith power sharingWithout power sharingHPA(W)TOC(dBm)HPA(W)TOC(dBm)TOC(W)TOC(dBm)TOC(W)TOC(dBm)1TRX4542.33 6043.58 3144.91 40.00 46.02 2TRX4542.33 6043.58 3144.91 40.00 46.02 3TRX4542.33 6043.58 2543.98 27.00 44.31 4TRX4542.33 6043.58 2043.01 20.00 43.01 5TRX-12.00 40.79 6TRX-10.00 40.00 4. 搬遷前后實(shí)際的覆蓋效果對(duì)比某Cluster, 搬遷前全部站點(diǎn)扇區(qū)均為Normal Power 1TRX或2TRX配置,搬遷后60%的扇區(qū)擴(kuò)容到3-5 TRX。搬遷前后路測(cè)覆蓋Rx_Lev對(duì)比結(jié)果如下表,覆蓋提升了8.84%,與上面功率映射結(jié)果相符。Table Error! No text of specified style in document.1 Rx_Lev before Swap and after SwapRangeBeforeAfterDifferent-70.00dBm to -10.00dBm82.49%91.33%8.84%-80.00dBm to -70.00dBm14.87%8.21%-6.66%-90.00dBm to -80.00dBm2.54%0.44%-2.10%-100.00dBm to -90.00dBm0.10%0.03%-0.07%-120.00dBm to -100.00dBm0.00%0.00%0.00%Figure Error! No text of specified style in document.1 Rx_Lev before Swap and after Swap4.1 Rx_Lev Distribution before SwapFigure 41 Rx_Lev Distribution before Swap (Idle Mode) 4.2 Rx_Lev Distribution after SwapFigure 42 Rx_Lev Distribution after Swap (Idle Mode)5. 附錄:Alcatel基站功率配置和合路雙工器單元ANCn Alcatel基站功率配置# TRXAlcatel-CombinedAlcatel-Non CombinedNormal PowerHigh PowerNormal PowerHigh PowerHPA(W)TOC(dBm)HPA(W)TOC(dBm)HPA(W)TOC(dBm)HPA(W)TOC(dBm)1TRX4542.33 6043.58 4545.73 6046.98 2TRX4542.33 6043.58 4545.73 6046.98 3TRX4542.33 6043.58 -4TRX4542.33 6043.58 -5TRX-6TRX-n Alcatel基站ANCAlcatel基站每個(gè)扇區(qū)至少使用一個(gè)ANC模塊,用于連接射頻發(fā)射單元TRE和天饋系統(tǒng),每ANC最大配置載頻數(shù)4TRX。主要功能如下: 設(shè)置與不同的TRE 對(duì)應(yīng)的LNA 的增益。 耦合多路發(fā)射機(jī)的輸出信號(hào),并將它們連接到天線。 將從天線接收到的射頻信號(hào)饋入到射頻前置單元,以便對(duì)信號(hào)進(jìn)行放大并送到不同接收機(jī)進(jìn)行處理。 在同一付天線上可以實(shí)現(xiàn)收發(fā)雙工。 帶通濾波以分離Rx 和Tx 的路徑。 檢測(cè)天線的VSWR 并提供VSWR 告警。ANC邏輯結(jié)構(gòu)圖:ANC的兩種工作模式:ANC可以工作于兩種模式:低損耗模式(Non-Combined)和寬帶耦合模式(Combined)。低損耗模式(Non-Combined)的配置方法:1. 拆掉電橋,將TRE的TX直接連到TX IN口,RX直接連到每個(gè)天線對(duì)應(yīng)的第一組RX口;2. 在BTS Terminal中,取消對(duì)電橋的選中。在低損耗模式下,將載頻
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 【正版授權(quán)】 ISO/IEC 14496-32:2025 EN Information technology - Coding of audio-visual objects - Part 32: File format reference software and conformance
- 2025年信息技術(shù)課程考試題及答案
- 2025年心理學(xué)綜合能力考試試題及答案
- 2025年心理學(xué)與教育專業(yè)考試試題及答案
- 2025年數(shù)字媒體與動(dòng)畫專業(yè)研究生入學(xué)考試試題及答案
- 2025年物流與供應(yīng)鏈管理考試試卷及答案
- 2025年分析化學(xué)基礎(chǔ)知識(shí)測(cè)試試卷及答案
- 2025年環(huán)境科學(xué)專業(yè)考試卷及答案
- 2025年保定市中考二模數(shù)學(xué)試題及答案
- 三個(gè)合伙人的合同范本
- 2鍋爐水壓試驗(yàn)方案
- 10kV真空柱上負(fù)荷開關(guān)自動(dòng)化成套設(shè)備調(diào)試報(bào)告
- 建筑節(jié)能PPT 課件
- 中醫(yī)護(hù)理耳穴壓豆課件
- 平臺(tái)印刷機(jī)-機(jī)械原理課程設(shè)計(jì)報(bào)告
- GB/T 6680-2003液體化工產(chǎn)品采樣通則
- GB/T 3651-2008金屬高溫導(dǎo)熱系數(shù)測(cè)量方法
- GB/T 32879-2016電動(dòng)汽車更換用電池箱連接器通用技術(shù)要求
- GB/T 2790-1995膠粘劑180°剝離強(qiáng)度試驗(yàn)方法撓性材料對(duì)剛性材料
- 《常見疾病康復(fù)》第一章常見功能障礙康復(fù)-1~3節(jié)
- GB/T 26745-2021土木工程結(jié)構(gòu)用玄武巖纖維復(fù)合材料
評(píng)論
0/150
提交評(píng)論