![施工現(xiàn)場(chǎng)臨時(shí)用電設(shè)計(jì)計(jì)算書(shū)通用計(jì)算式_第1頁(yè)](http://file4.renrendoc.com/view/79f9d456b1080f63f09dec54f39af6a1/79f9d456b1080f63f09dec54f39af6a11.gif)
![施工現(xiàn)場(chǎng)臨時(shí)用電設(shè)計(jì)計(jì)算書(shū)通用計(jì)算式_第2頁(yè)](http://file4.renrendoc.com/view/79f9d456b1080f63f09dec54f39af6a1/79f9d456b1080f63f09dec54f39af6a12.gif)
![施工現(xiàn)場(chǎng)臨時(shí)用電設(shè)計(jì)計(jì)算書(shū)通用計(jì)算式_第3頁(yè)](http://file4.renrendoc.com/view/79f9d456b1080f63f09dec54f39af6a1/79f9d456b1080f63f09dec54f39af6a13.gif)
![施工現(xiàn)場(chǎng)臨時(shí)用電設(shè)計(jì)計(jì)算書(shū)通用計(jì)算式_第4頁(yè)](http://file4.renrendoc.com/view/79f9d456b1080f63f09dec54f39af6a1/79f9d456b1080f63f09dec54f39af6a14.gif)
![施工現(xiàn)場(chǎng)臨時(shí)用電設(shè)計(jì)計(jì)算書(shū)通用計(jì)算式_第5頁(yè)](http://file4.renrendoc.com/view/79f9d456b1080f63f09dec54f39af6a1/79f9d456b1080f63f09dec54f39af6a15.gif)
版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
施工現(xiàn)電計(jì)算書(shū)臨時(shí)用電的負(fù)荷及其分類各干線用電設(shè)備分配表序號(hào)干線文案大全151501A組鋼筋彎曲機(jī)412.01602A組插入式振動(dòng)機(jī)1319.51702A組平板式振動(dòng)器66.61803鋼筋對(duì)焊機(jī)125.01904鋼筋對(duì)焊機(jī)125.0負(fù)荷計(jì)算1.總電力負(fù)荷計(jì)算按總裝容量計(jì)算:ΣP=301.70kW,K=0.41 e xP=KΣP=0.41×301.70=123.70kWjs xS=1.25P=1.25×123.70=154.63kVAjs1 js按負(fù)荷分組計(jì)算:用電不均衡系數(shù)取1.05電動(dòng)機(jī)負(fù)荷P=247.70kW,數(shù)量40,K=0.45;電焊機(jī)負(fù)荷S=18.00kW,數(shù)量2,K=0.65;室內(nèi)照明用電P=20.00kW, s 1 2 s2數(shù)量2,K=0.70;室外照明用電P=16.00kW,數(shù)量4,K=0.70; 3 s3 4S=1.05×(1.38KP+KS+KP+KP)js2 1s 2 3s2 4s3=1.05×(1.38×0.45×247.7+0.65×18+0.70×20+0.70×16)=200.26kVA比較S、S,取S=S=200.26kVAjs1 js2 js js22.變壓器、發(fā)電機(jī)組容量的選擇變壓器的額定容量S≥S=200.26kVA,取值250kVA自備發(fā)電機(jī)組容量P≥0.8S=0.8×200.26=160.21kW,取值 e js e js200kW。四、總干線(Z)線路電流計(jì)算、電器選用、導(dǎo)線面積的選擇1.總干線(Z)線路電流計(jì)算總干線電力負(fù)荷的計(jì)算電流I=1.52S=1.52×200.26=304.40A js js總干線總?cè)垠w額定電流計(jì)算I≥1.52S+2.4P=1.52×200.26+2.4×0=304.40A er js 1max2.總配電箱的選用1)選擇帶總隔離開(kāi)關(guān)+總斷路器+總漏電保護(hù)器的配電箱總干線開(kāi)關(guān)額定電流計(jì)算I≥I=304.40A總隔離開(kāi)關(guān)和總斷路器的定流400A總干線漏電開(kāi)關(guān)額定電流計(jì)算I≥1.3I=1.3×304.40=395.72A總漏電保護(hù)器額定電流400A,定100mA,額定漏電動(dòng)作時(shí)間0.2s。3.導(dǎo)線截面積的選擇1)導(dǎo)線截面積的選擇按發(fā)熱條件導(dǎo)線的截面積I=I=304.40A穿管(4根)絕緣導(dǎo)線:BVV324+2×120>16mm2,導(dǎo)線載流量I=326.40AL2)導(dǎo)線校驗(yàn)總干線短路保護(hù):I=304.40A≤1.5I=1.5×326.40=489.60A,滿足要求。 er L總干線過(guò)載保護(hù):I、I=304.40A≤1.25I=1.25×326.40=408.00A,滿足要求。1號(hào)分對(duì)應(yīng)的總配電箱分路開(kāi)關(guān)電器選用、導(dǎo)線截面積的選擇1.電流計(jì)算按總裝容量計(jì)算:ΣP=68.50kWK=0.74P=KΣP=0.74×68.50=50.55kW e x js x eS=1.25P=1.25×50.55=63.19kVA分=1.52S=1.52×63.19=96.05A js js分干線總?cè)垠w額定電流計(jì)算I≥1.52S+2.4P=1.52×63.19+2.4×12.00=124.85A er js 1max2.分配電箱的選用選擇總隔離開(kāi)關(guān)+總斷路器的分配電箱分干線開(kāi)關(guān)額定電流計(jì)算I≥I=124.85A,總隔離開(kāi)關(guān)額定電流125A h er總斷路器額定電流125A??偱潆娤渲蟹致犯綦x開(kāi)關(guān)額定電流為160A,分路斷路器額定電流160A;3.分配電箱進(jìn)線的導(dǎo)線截面積選擇1)導(dǎo)線截面積的選擇按發(fā)熱條件選擇導(dǎo)線的截面積I≥I=96.05A L js總配電箱中分路開(kāi)關(guān)額定電流為160A穿管(4根)絕緣導(dǎo)線:BVV3×95+2×50>16mm2,導(dǎo)線載流量I=172.80AL導(dǎo)線校驗(yàn)1號(hào)分干線短路保護(hù):I=124.85A≤1.5I=1.5×172.80=259.20A,滿足要求。 er L1號(hào)分干線過(guò)載保護(hù):I、I=124.85A≤1.25I=1.25×172.80=216.00A,滿足要求。2號(hào)器選用及對(duì)應(yīng)的配電箱分路開(kāi)關(guān)電器選用、導(dǎo)線截面積的選擇1.電流計(jì)算按總裝容量計(jì)算:ΣP=117.10kWK=0.73P=KΣP=0.73×117.10=85.87kW e x js x eS=1.25P=1.25×85.87=107.34kVA分=1.52S=1.52×107.34=163.15A js js分干線總?cè)垠w額定電流計(jì)算I≥1.52S+2.4P=1.52×107.34+2.4×24.00=220.75A er js 1max2.分配電箱的選用選擇總隔離開(kāi)關(guān)+總斷路器的分配電箱分干線開(kāi)關(guān)額定電流計(jì)算I≥I=220.75A,總隔離開(kāi)關(guān)額定電流225A h er總斷路器額定電流225A。總配電箱中分路隔離開(kāi)關(guān)額定電流為250A,分路斷路器額定電流250A;3.分配電箱進(jìn)線的導(dǎo)線截面積選擇1)導(dǎo)線截面積的選擇按發(fā)熱條件選擇導(dǎo)線的截面積I≥I=163.15A L js總配電箱中分路開(kāi)關(guān)額定電流為250A穿管(4根)絕緣導(dǎo)線:BVV3×95+2×50>16mm2,導(dǎo)線載流量I=172.80AL導(dǎo)線校驗(yàn)2號(hào)分干線短路保護(hù):I=220.75A≤1.5I=1.5×172.80=259.20A,滿足要求。 er L2號(hào)分干線過(guò)載保護(hù):I、I=220.75A>1.25I=1.25×172.80=216.00A,不滿足要求。3號(hào)器選用及對(duì)應(yīng)的配電箱分路開(kāi)關(guān)電器選用、導(dǎo)線截面積的選擇1.電流計(jì)算按總裝容量計(jì)算:ΣP=116.10kWK=0.57P=KΣP=0.57×116.10=65.93kW e x js x eS=1.25P=1.25×65.93=82.41kVA分=1.52S=1.52×82.41=125.27A js js分干線總?cè)垠w額定電流計(jì)算I≥1.52S+2.4P=1.52×82.41+2.4×25.00=185.27A er js 1max2.分配電箱的選用選擇總隔離開(kāi)關(guān)+總斷路器的分配電箱分干線開(kāi)關(guān)額定電流計(jì)算I≥I=185.27A,總隔離開(kāi)關(guān)額定電流200A h er總斷路器額定電流200A??偱潆娤渲蟹致犯綦x開(kāi)關(guān)額定電流為225A,分路斷路器額定電流225A;3.分配電箱進(jìn)線的導(dǎo)線截面積選擇1)導(dǎo)線截面積的選擇按發(fā)熱條件選擇導(dǎo)線的截面積I≥I=125.27A L js總配電箱中分路開(kāi)關(guān)額定電流為225A穿管(4根)絕緣導(dǎo)線:BVV3×95+2×50>16mm2,導(dǎo)線載流量I=172.80AL導(dǎo)線校驗(yàn)3號(hào)分干線短路保護(hù):I=185.27A≤1.5I=1.5×172.80=259.20A,滿足要求。 er L3號(hào)分干線過(guò)載保護(hù):I、I=185.27A≤1.25I=1.25×172.80=216.00A,滿足要求。設(shè)備組及最大功率設(shè)備開(kāi)箱進(jìn)線線路電流算、電器選用01干線01分路設(shè)備計(jì)算計(jì)算電流I=KP/(30.5Uηcosφ)=0.83×34.00/(30.5×0.38×1.0×1.0)=94.64A的用選用帶隔離開(kāi)關(guān)+斷路器+漏電保護(hù)器的開(kāi)關(guān)箱隔離開(kāi)關(guān)100A/4,斷路器100/4(100A),漏電保護(hù)器100/4(100A,30mA,0.1s)。對(duì)應(yīng)分配電箱的類型,選取分配電箱中的分路隔離開(kāi)關(guān)。分配電箱PF1中分路隔離開(kāi)關(guān)額定電流為125A,分路短路器額定電流125A。開(kāi)關(guān)箱進(jìn)線的導(dǎo)線截面積的選擇按發(fā)熱條件選擇導(dǎo)線的截面積I<I=94.64A L s分配電箱分路開(kāi)關(guān)的額定電流125A架空絕緣導(dǎo)線:BV3×16+2×16,導(dǎo)線載流量I=88.9A<125A。L01干線01分路單臺(tái)最大功率設(shè)備計(jì)算計(jì)算電流I=P/(30.5Ucosφ)=12.00/(30.5×0.38×1.0)=18.23A箱選用選用帶隔離開(kāi)關(guān)+斷路器+漏電保護(hù)器的開(kāi)關(guān)箱隔離開(kāi)關(guān)20A/4,斷路器20/4(20A),漏電保護(hù)器20/4(20A,30mA,0.1s)。開(kāi)關(guān)箱出線的導(dǎo)線截面積的選擇按照設(shè)備的說(shuō)明書(shū)要求采用匹配的電源線。01干線02分路設(shè)備計(jì)算1)計(jì)算電流I=KP/(30.5Uηcosφ)﹢Kε0.5P/U=0.80×16.50/(30.5×0.38×0.7×0.7)+0.50×0.500.5× S Xn n X1 n n1 n18.00/0.38=57.68A開(kāi)關(guān)箱的選用選用帶隔離開(kāi)關(guān)+斷路器+漏電保護(hù)器的開(kāi)關(guān)箱隔離開(kāi)關(guān)63A/4,斷路器63/4(63A),漏電保護(hù)器63/4(63A,30mA,0.1s)。對(duì)應(yīng)分配電箱的類型,選取分配電箱中的分路隔離開(kāi)關(guān)。分配電箱PF1中分路隔離開(kāi)關(guān)額定電流為80A,分路短路器額定電流80A。開(kāi)關(guān)箱進(jìn)線的導(dǎo)線截面積的選擇按發(fā)熱條件選擇導(dǎo)線的截面積I≥I=57.68A L s分配電箱分路開(kāi)關(guān)的額定電流80A架空絕緣導(dǎo)線:BV3×16+2×16,導(dǎo)線載流量I=88.9A>80A,滿足要求。L01干線02分路單臺(tái)最大功率設(shè)備計(jì)算1)計(jì)算電流I=ε0.5P/U=0.50.5×9.00/0.38=16.75A S n n n開(kāi)關(guān)箱的選用選用帶隔離開(kāi)關(guān)+斷路器+漏電保護(hù)器的開(kāi)關(guān)箱隔離開(kāi)關(guān)20A/4,斷路器20/4(20A),漏電保護(hù)器20/4(20A,30mA,0.1s)。開(kāi)關(guān)箱出線的導(dǎo)線截面積的選擇按照設(shè)備的說(shuō)明書(shū)要求采用匹配的電源線。02干線01分路設(shè)備計(jì)算1)計(jì)算電流I=KP/(30.5Uηcosφ)=0.75×41.70/(30.5×0.38×0.7×0.7)=84.43A S Xn n開(kāi)關(guān)箱的選用選用帶隔離開(kāi)關(guān)+斷路器+漏電保護(hù)器的開(kāi)關(guān)箱隔離開(kāi)關(guān)100A/4,斷路器100/4(100A),漏電保護(hù)器100/4(100A,30mA,0.1s)。分路干線開(kāi)關(guān)額定電流應(yīng)大于單臺(tái)設(shè)備開(kāi)關(guān)額定電流,已知單臺(tái)設(shè)備開(kāi)關(guān)額定電流最大值是125A;因此分路干線開(kāi)關(guān)額定電流調(diào)整到125A。對(duì)應(yīng)分配電箱的類型,選取分配電箱中的分路隔離開(kāi)關(guān)。分配電箱PF2中分路隔離開(kāi)關(guān)額定電流為125A,分路短路器額定電流125A。開(kāi)關(guān)箱進(jìn)線的導(dǎo)線截面積的選擇按發(fā)熱條件選擇導(dǎo)線的截面積I<I=84.43A L s分配電箱分路開(kāi)關(guān)的額定電流125A架空絕緣導(dǎo)線:YC3×16+2×10,導(dǎo)線載流量I=71.9A<125A。L02干線01分路單臺(tái)最大功率設(shè)備計(jì)算1)計(jì)算電流I=2ε0.5P/(30.5Uηcosφ)=2×0.250.5×34.70/(30.5×0.38×0.7×0.7)=107.59A S n n n開(kāi)關(guān)箱的選用選用帶隔離開(kāi)關(guān)+斷路器+漏電保護(hù)器的開(kāi)關(guān)箱隔離開(kāi)關(guān)125A/4,斷路器125/4(125A),漏電保護(hù)器125/4(125A,30mA,0.1s)。開(kāi)關(guān)箱出線的導(dǎo)線截面積的選擇按照設(shè)備的說(shuō)明書(shū)要求采用匹配的電源線。02干線02分路設(shè)備計(jì)算計(jì)算電流I=KP/(30.5Uηcosφ)=0.72×37.70/(30.5×0.38×0.7×0.7)=79.13A的用選用帶隔離開(kāi)關(guān)+斷路器+漏電保護(hù)器的開(kāi)關(guān)箱隔離開(kāi)關(guān)80A/4,斷路器80/4(80A),漏電保護(hù)器80/4(80A,30mA,0.1s)。分路干線開(kāi)關(guān)額定電流應(yīng)大于單臺(tái)設(shè)備開(kāi)關(guān)額定電流,已知單臺(tái)設(shè)備開(kāi)關(guān)額定電流最大值是125A;因此分路干線開(kāi)關(guān)額定電流調(diào)整到100A。對(duì)應(yīng)分配電箱的類型,選取分配電箱中的分路隔離開(kāi)關(guān)。分配電箱PF2中分路隔離開(kāi)關(guān)額定電流為100A,分路短路器額定電流100A。開(kāi)關(guān)箱進(jìn)線的導(dǎo)線截面積的選擇按發(fā)熱條件選擇導(dǎo)線的截面積I<I=79.13A L s分配電箱分路開(kāi)關(guān)的額定電流100A架空絕緣導(dǎo)線:YC3×16+2×10,導(dǎo)線載流量I=71.9A<100A。L02干線02分路單臺(tái)最大功率設(shè)備計(jì)算1)計(jì)算電流I=2ε0.5P/(30.5Uηcosφ)=2×0.250.5×34.70/(30.5×0.38×0.7×0.7)=107.59A S n n n開(kāi)關(guān)箱的選用選用帶隔離開(kāi)關(guān)+斷路器+漏電保護(hù)器的開(kāi)關(guān)箱隔離開(kāi)關(guān)125A/4,斷路器125/4(125A),漏電保護(hù)器125/4(125A,30mA,0.1s)。開(kāi)關(guān)箱出線的導(dǎo)線截面積的選擇按照設(shè)備的說(shuō)明書(shū)要求采用匹配的電源線。02干線03分路設(shè)備計(jì)算計(jì)算電流I=KP/(30.5Uηcosφ)=0.72×37.70/(30.5×0.38×0.7×0.7)=79.13A的用選用帶隔離開(kāi)關(guān)+斷路器+漏電保護(hù)器的開(kāi)關(guān)箱隔離開(kāi)關(guān)80A/4,斷路器80/4(80A),漏電保護(hù)器80/4(80A,30mA,0.1s)。分路干線開(kāi)關(guān)額定電流應(yīng)大于單臺(tái)設(shè)備開(kāi)關(guān)額定電流,已知單臺(tái)設(shè)備開(kāi)關(guān)額定電流最大值是125A;因此分路干線開(kāi)關(guān)額定電流調(diào)整到100A。對(duì)應(yīng)分配電箱的類型,選取分配電箱中的分路隔離開(kāi)關(guān)。分配電箱PF2中分路隔離開(kāi)關(guān)額定電流為100A,分路短路器額定電流100A。開(kāi)關(guān)箱進(jìn)線的導(dǎo)線截面積的選擇按發(fā)熱條件選擇導(dǎo)線的截面積I<I=79.13A L s分配電箱分路開(kāi)關(guān)的額定電流100A架空絕緣導(dǎo)線:YC3×16+2×10,導(dǎo)線載流量I=71.9A<100A。L02干線03分路單臺(tái)最大功率設(shè)備計(jì)算1)計(jì)算電流I=2ε0.5P/(30.5Uηcosφ)=2×0.250.5×34.70/(30.5×0.38×0.7×0.7)=107.59A S n n n開(kāi)關(guān)箱的選用選用帶隔離開(kāi)關(guān)+斷路器+漏電保護(hù)器的開(kāi)關(guān)箱隔離開(kāi)關(guān)125A/4,斷路器125/4(125A),漏電保護(hù)器125/4(125A,30mA,0.1s)。開(kāi)關(guān)箱出線的導(dǎo)線截面積的選擇按照設(shè)備的說(shuō)明書(shū)要求采用匹配的電源線。03干線01分路設(shè)備計(jì)算計(jì)算電流I=KP/(30.5Uηcosφ)=0.61×40.00/(30.5×0.22×0.81×0.7)=106.53A的用選用帶隔離開(kāi)關(guān)+斷路器+漏電保護(hù)器的開(kāi)關(guān)箱隔離開(kāi)關(guān)125A/2,斷路器125/2(125A),漏電保護(hù)器125/2(125A,30mA,0.1s)。對(duì)應(yīng)分配電箱的類型,選取分配電箱中的分路隔離開(kāi)關(guān)。分配電箱PF3中分路隔離開(kāi)關(guān)額定電流為160A,分路短路器額定電流160A。開(kāi)關(guān)箱進(jìn)線的導(dǎo)線截面積的選擇按發(fā)熱條件選擇導(dǎo)線的截面積I≥I=106.53A L s分配電箱分路開(kāi)關(guān)的額定電流160A架空絕緣導(dǎo)線:BV3×70,導(dǎo)線載流量I=224.3A>160A,滿足要求。L03干線01分路單臺(tái)最大功率設(shè)備計(jì)算計(jì)算電流I=P/(30.5Uηcosφ)=4.00/(30.5×0.22×0.81×0.7)=18.51A箱選用選用帶隔離開(kāi)關(guān)+斷路器+漏電保護(hù)器的開(kāi)關(guān)箱隔離開(kāi)關(guān)20A/2,斷路器20/2(20A),漏電保護(hù)器20/2(20A,30mA,0.1s)。開(kāi)關(guān)箱出線的導(dǎo)線截面積的選擇按照設(shè)備的說(shuō)明書(shū)要求采用匹配的電源線。03干線02分路設(shè)備計(jì)算計(jì)算電流I=KP/(30.5Uηcosφ)=0.45×26.10/(30.5×0.22×0.7×0.7)=62.82A的用選用帶隔離開(kāi)關(guān)+斷路器+漏電保護(hù)器的開(kāi)關(guān)箱隔離開(kāi)關(guān)63A/2,斷路器63/2(63A),漏電保護(hù)器63/2(63A,30mA,0.1s)。對(duì)應(yīng)分配電箱的類型,選取分配電箱中的分路隔離開(kāi)關(guān)。分配電箱PF3中分路隔離開(kāi)關(guān)額定電流為80A,分路短路器額定電流80A。開(kāi)關(guān)箱進(jìn)線的導(dǎo)線截面積的選擇按發(fā)熱條件選擇導(dǎo)線的截面積I≥I=62.82A L s分配電箱分路開(kāi)關(guān)的額定電流80A架空絕緣導(dǎo)線:BV3×16,導(dǎo)線載流量I=88.9A>80A,滿足要求。L03干線02分路單臺(tái)最大功率設(shè)備計(jì)算計(jì)算電流I=P/(30.5Uηcosφ)=1.50/(30.5×0.22×0.7×0.7)=8.03A箱選用選用帶隔離開(kāi)關(guān)+斷路器+漏電保護(hù)器的開(kāi)關(guān)箱隔離開(kāi)關(guān)16A/2,斷路器16/2(16A),漏電保護(hù)器16/2(16A,30mA,0.1s)。開(kāi)關(guān)箱出線的導(dǎo)線截面積的選擇按照設(shè)備的說(shuō)明書(shū)要求采用匹配的電源線。03干線03分路設(shè)備計(jì)算1)計(jì)算電流I=ε0.5P/U=0.50.5×25.00/0.38=46.52A S n n n開(kāi)關(guān)箱的選用選用帶隔離開(kāi)關(guān)+斷路器+漏電保護(hù)器的開(kāi)關(guān)箱隔離開(kāi)關(guān)50A/4,斷路器50/4(50A),漏電保護(hù)器50/4(50A,30mA,0.1s)。對(duì)應(yīng)分配電箱的類型,選取分配電箱中的分路隔離開(kāi)關(guān)。分配電箱PF3中分路隔離開(kāi)關(guān)額定電流為63A,分路短路器額定電流63A。開(kāi)關(guān)箱進(jìn)線的導(dǎo)線截面積的選擇按發(fā)熱條件選擇導(dǎo)線的截面積I≥I=46.52A L s分配電箱分路開(kāi)關(guān)的額定電流63A架空絕緣導(dǎo)線:BV3×16+2×16,導(dǎo)線載流量I=88.9A>63A,滿足要求。L03干線04分路設(shè)備計(jì)算1)計(jì)算電流I=ε0.5P/U=0.50.5×25.00/0.38=46.52A S n n n開(kāi)關(guān)箱的選用選用帶隔離開(kāi)關(guān)+斷路器+漏電保護(hù)器的開(kāi)關(guān)箱隔離開(kāi)關(guān)50A/4,斷路器50/4(50A),漏電保護(hù)器50/4(50A,30mA,0.1s)。對(duì)應(yīng)分配電箱的類型,選取分配電箱中的分路隔離開(kāi)關(guān)。分配電箱PF3中分路隔離開(kāi)關(guān)額定電流為63A,分路短路器額定電流63A。開(kāi)關(guān)箱進(jìn)線的導(dǎo)線截面積的選擇按發(fā)熱條件選擇導(dǎo)線的截面積I≥I=46.52A L s分配電箱分路開(kāi)關(guān)的額定電流63A架空絕緣導(dǎo)線:BV3×16+2×16,導(dǎo)線載流量I=88.9A>63A,滿足要求。L臨時(shí)用電總系統(tǒng)圖BVV3×240+2×120臨時(shí)用電總系統(tǒng)圖BVV3×240+2×120400/4400/4400/4mA,0.2s100180/4180/4250/4250/4225/4225/4PZ(301.7kW)VAWHBVV3×95+2×50160/4160/4125/4125/4/4804/80PF1(68.5kW)BV3×161號(hào)分干線分路1(P1-P4)BV3×16+2×161號(hào)分干線分路2(P5-P9)BVV3×95+2×50225/4225/4125/4125/4100/4100/4100/4100/4PF2(117.1kW)BV3×16+2×162號(hào)分干線分路1(P10-P11)YC3×16+2×102號(hào)分干線分路2(P12-P13)YC3×16+2×102號(hào)分干線分路3(P14-P15)BVV3×95+2×50200/4200/4160/2160/280/280/263/463/463/463/4PF3(116.1kW)BV3×703號(hào)分干線分路1(P16-P27)BV3×163號(hào)分干線分路2(P28-P46)BV3×16+2×1650/450/450/430mA,0.1sP47(25.0kW)BV3×16+2×1650/450/450/430mA,0.1s P48(25.0kW) BV3×16BV3×1663/463/463/430mA,0.1s卷?yè)P(yáng)機(jī)P1(11.0kW)A組BV3×2.516/216/2216/30mA,0.1s室外照明(道路照明)P2(3.0kW)BV3×2.516/416/416/4mA,0.1s30室內(nèi)照明(生活用電)P3(8.0kW)BV3×2.520/420/420/430mA,0.1s室內(nèi)照明(生活照明)P4(12.0kW)號(hào)分干線分路1用電系統(tǒng)圖11號(hào)分干線分路1BV3×2.5+2×2.5BV3×2.5+2×2.516/416/416/430mA,0.1s交流電焊機(jī)P5(9.0kW)BV3×2.5+2×2.5416/16/416/430mA,0.1s交流電焊機(jī)P6(9.0kW)BV3×2.5+2×2.520/4420/420/30mA,0.1s木工圓鋸P7(5.5kW)BV3×2.5+2×2.520/420/420/4mA,0.1s30木工圓鋸P8(5.5kW)BV3×2.5+2×2.520/420/420/430mA,0.1s木工圓鋸P9(5.5kW)號(hào)分干線分路2用電系統(tǒng)圖12號(hào)分干線分路1BV3×70+2×35BV3×70+2×35125/4125/4125/430mA,0.1s塔吊P10(34.7kW)BV3×2.5+2×2.5
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年二年級(jí)第一學(xué)期教研工作總結(jié)(三篇)
- 2025年二年級(jí)老師教育工作總結(jié)模版(三篇)
- 2025年臨時(shí)租車協(xié)議樣本(2篇)
- 創(chuàng)意園區(qū)裝修協(xié)議
- 國(guó)際學(xué)校裝修合作合同模板
- 家電銷售居間服務(wù)合同
- 教育培訓(xùn)招生私人居間合同
- 木材物流協(xié)議范本
- 賓館客房改造追加協(xié)議
- 親子莊園別墅裝修合同范本
- 2025年中國(guó)中煤能源股份有限公司招聘筆試參考題庫(kù)含答案解析
- 2024年度碳陶剎車盤分析報(bào)告
- 2025年1月 浙江首考英語(yǔ)試卷
- 2025年1月廣西2025屆高三調(diào)研考試英語(yǔ)試卷(含答案詳解)
- 2024年中考二輪專題復(fù)習(xí)道德與法治主觀題答題技巧(小論文)之演講稿
- 質(zhì)檢工作計(jì)劃書(shū)2025質(zhì)檢部工作計(jì)劃范文
- 《復(fù)旦大學(xué)》課件
- 《纏論的實(shí)戰(zhàn)技法》課件
- 承包魚(yú)塘維修施工合同范例
- 耶魯綜合抽動(dòng)嚴(yán)重程度量表正式版
- 政府采購(gòu)項(xiàng)目采購(gòu)需求調(diào)查指引文本
評(píng)論
0/150
提交評(píng)論